Michael Fenchel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael Fenchel has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Claus D. Claussen
Department of Diagnostic Radiology, University Hospital of Tübingen, Tübingen, Germany
3 shared publicationsUlrich Kramer
Department of Diagnostic Radiology, University Hospital of Tübingen, Tübingen, Germany
3 shared publicationsNorbert I. Stauder
Department of Diagnostic Radiology, Eberhard‐Karls‐University, Tuebingen, Germany
2 shared publicationsStephan Miller
Department of Diagnostic Radiology, Eberhard‐Karls‐University, Tuebingen, Germany
2 shared publicationsAndreas Greiser
Department of Magnetic Resonance, Siemens Medical Solutions, Erlangen, Germany
1 shared publicationCo‐Nghi Nguyen
Department of Nuclear Medicine, Eberhard‐Karls‐University, Tuebingen, Germany
1 shared publication
Latest Publications
- 30 November 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 57 (1) , 213-219
Optimization of blood–myocardial contrast in 3D true FISP cardiac imaging at 1.5 T
Three‐dimensional (3D) steady‐state free precession (SSFP) MRI sequences are often applied to visualize both intra‐ and extracardiac pathologies. In the present study the contrast behavior of 3D true fast imaging with steady precession (True‐FISP) sequences for cardiac imaging was optimized in numerical simulations and compared with measurements obtained in eight healthy volunteers on a 1.5 T whole‐body scanner. Two SS preparation schemes in combination with and without a T2 preparation were assessed to improve contrast between blood and myocardium using a navigator‐gated and ECG‐triggered 3D True‐FISP sequence. Numerical simulations and experimental studies in volunteers showed that an SS preparation using a constant flip angle (CFA) is preferable to a linear flip angle (LFA) preparation in terms of contrast between blood and myocardium. The optimized 3D True‐FISP sequence provides a reliable, accurate, and time‐efficient means of obtaining a morphological cardiac diagnosis. Magn Reson Med 57:213–219, 2007.
- 30 November 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 57 (1) , 213-219
Optimization of blood–myocardial contrast in 3D true FISP cardiac imaging at 1.5 T
Three‐dimensional (3D) steady‐state free precession (SSFP) MRI sequences are often applied to visualize both intra‐ and extracardiac pathologies. In the present study the contrast behavior of 3D true fast imaging with steady precession (True‐FISP) sequences for cardiac imaging was optimized in numerical simulations and compared with measurements obtained in eight healthy volunteers on a 1.5 T whole‐body scanner. Two SS preparation schemes in combination with and without a T2 preparation were assessed to improve contrast between blood and myocardium using a navigator‐gated and ECG‐triggered 3D True‐FISP sequence. Numerical simulations and experimental studies in volunteers showed that an SS preparation using a constant flip angle (CFA) is preferable to a linear flip angle (LFA) preparation in terms of contrast between blood and myocardium. The optimized 3D True‐FISP sequence provides a reliable, accurate, and time‐efficient means of obtaining a morphological cardiac diagnosis. Magn Reson Med 57:213–219, 2007.
- Open Access
- 15 April 2005
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 21 (5) , 596-603
Whole‐body MR angiography using a novel 32‐receiving‐channel MR system with surface coil technology: First clinical experience
Purpose: To demonstrate the feasibility of detecting atherosclerotic vascular disease using an innovative magnetic resonance angiography (MRA) protocol in combination with a dedicated whole‐body MR scanner with new surface coil technology.Materials and Methods: A total of 10 volunteers and eight patients with peripheral arterial occlusive disease (PAOD) were examined at 1.5 T. Conventional digital subtraction angiography (DSA) of the symptomatic region was available as a reference standard in all eight patients. Depending on subjects' size, four to five three‐dimensional data sets were acquired using an adapted injection protocol. Images were assessed independently by two readers for vascular pathology. Additionally, signal‐to‐noise ratios (SNRs) and contrast‐to‐noise ratios (CNRs) were measured.Results: Whole‐body MRA yielded excellent sensitivity and specificity of more than 95% for both readers with high interobserver agreement (k = 0.93). Surface coil signal reception rendered a high SNR (mean 151.28 ± 54.04) and CNR (mean 120.75 ± 46.47). Despite lower SNR and CNR of the cranial and cervical vessels, a two‐step injection protocol exhibited less venous superposition and therefore proved to be superior compared to single‐bolus injection.Conclusion: Our approach provides accurate noninvasive high‐resolution imaging of systemic atherosclerotic disease, covering the arterial vasculature from intracranial arteries to distal runoff vessels. The recently introduced MR scanner and coil technology is feasible to significantly increase the performance of whole‐body MRA. J. Magn. Reson. Imaging 2005;21:596–603.
- 15 April 2005
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 21 (5) , 596-603
Open AccessWhole‐body MR angiography using a novel 32‐receiving‐channel MR system with surface coil technology: First clinical experience
Purpose: To demonstrate the feasibility of detecting atherosclerotic vascular disease using an innovative magnetic resonance angiography (MRA) protocol in combination with a dedicated whole‐body MR scanner with new surface coil technology.Materials and Methods: A total of 10 volunteers and eight patients with peripheral arterial occlusive disease (PAOD) were examined at 1.5 T. Conventional digital subtraction angiography (DSA) of the symptomatic region was available as a reference standard in all eight patients. Depending on subjects' size, four to five three‐dimensional data sets were acquired using an adapted injection protocol. Images were assessed independently by two readers for vascular pathology. Additionally, signal‐to‐noise ratios (SNRs) and contrast‐to‐noise ratios (CNRs) were measured.Results: Whole‐body MRA yielded excellent sensitivity and specificity of more than 95% for both readers with high interobserver agreement (k = 0.93). Surface coil signal reception rendered a high SNR (mean 151.28 ± 54.04) and CNR (mean 120.75 ± 46.47). Despite lower SNR and CNR of the cranial and cervical vessels, a two‐step injection protocol exhibited less venous superposition and therefore proved to be superior compared to single‐bolus injection.Conclusion: Our approach provides accurate noninvasive high‐resolution imaging of systemic atherosclerotic disease, covering the arterial vasculature from intracranial arteries to distal runoff vessels. The recently introduced MR scanner and coil technology is feasible to significantly increase the performance of whole‐body MRA. J. Magn. Reson. Imaging 2005;21:596–603.
- Open Access
- 21 April 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (5) , 555-563
Multislice first‐pass myocardial perfusion imaging: Comparison of saturation recovery (SR)‐TrueFISP‐two‐dimensional (2D) and SR‐TurboFLASH‐2D pulse sequences
Purpose To compare signal‐to‐noise ratio (SNR), contrast‐to‐noise (CNR) ratio, and diagnostic accuracy of a newly developed saturation recovery (SR)‐TrueFISP‐two‐dimensional (2D) sequence with an SR‐TurboFLASH‐2D sequence. Materials and Methods In seven healthy subjects and nine patients with coronary artery disease (CAD), contrast‐enhanced perfusion imaging (with Gd‐DTPA) was performed with SR‐TrueFISP and SR‐TurboFLASH sequences. Hypoperfused areas were assessed qualitatively (scale = 0–4). Furthermore, SNR and CNR were calculated and semiquantitative perfusion parameters were determined from signal intensity (SI) time curves. Standard of reference for patient studies was single‐photon emission computer tomography (SPECT) and angiography. Results The perception of perfusion deficits was superior in TrueFISP images (2.6 ± 1.0) than in TurboFLASH (1.4 ± 0.6) (P < 0.001). Phantom measurements yielded increased SNR (143 ± 34%) and CNR (158 ± 64%) values for TrueFISP. In patient/volunteer studies SNR was 61% to 100% higher and signal enhancement was 110% to 115% higher with TrueFISP than with TurboFLASH. Qualitative and semiquantitative assessment of perfusion defects yielded higher sensitivities for detection of perfusion defects with TrueFISP (68% to 78%) than with TurboFLASH (44% to 59%). Conclusion SR‐TrueFISP‐2D perfusion imaging provides superior SNR and CNR than TurboFLASH imaging. Moreover, the dynamic range of SIs was found to be higher with TrueFISP, resulting in an increased sensitivity for detection of perfusion defects. J. Magn. Reson. Imaging 2004;19:555–563.
- 21 April 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (5) , 555-563
Open AccessMultislice first‐pass myocardial perfusion imaging: Comparison of saturation recovery (SR)‐TrueFISP‐two‐dimensional (2D) and SR‐TurboFLASH‐2D pulse sequences
Purpose To compare signal‐to‐noise ratio (SNR), contrast‐to‐noise (CNR) ratio, and diagnostic accuracy of a newly developed saturation recovery (SR)‐TrueFISP‐two‐dimensional (2D) sequence with an SR‐TurboFLASH‐2D sequence. Materials and Methods In seven healthy subjects and nine patients with coronary artery disease (CAD), contrast‐enhanced perfusion imaging (with Gd‐DTPA) was performed with SR‐TrueFISP and SR‐TurboFLASH sequences. Hypoperfused areas were assessed qualitatively (scale = 0–4). Furthermore, SNR and CNR were calculated and semiquantitative perfusion parameters were determined from signal intensity (SI) time curves. Standard of reference for patient studies was single‐photon emission computer tomography (SPECT) and angiography. Results The perception of perfusion deficits was superior in TrueFISP images (2.6 ± 1.0) than in TurboFLASH (1.4 ± 0.6) (P < 0.001). Phantom measurements yielded increased SNR (143 ± 34%) and CNR (158 ± 64%) values for TrueFISP. In patient/volunteer studies SNR was 61% to 100% higher and signal enhancement was 110% to 115% higher with TrueFISP than with TurboFLASH. Qualitative and semiquantitative assessment of perfusion defects yielded higher sensitivities for detection of perfusion defects with TrueFISP (68% to 78%) than with TurboFLASH (44% to 59%). Conclusion SR‐TrueFISP‐2D perfusion imaging provides superior SNR and CNR than TurboFLASH imaging. Moreover, the dynamic range of SIs was found to be higher with TrueFISP, resulting in an increased sensitivity for detection of perfusion defects. J. Magn. Reson. Imaging 2004;19:555–563.