Takashi Azuma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takashi Azuma has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Kenji Yamazaki
Department of Cardiovascular Surgery, Tokyo Women's Medical University, Tokyo, Japan
4 shared publicationsYoshihiko Yokoi
Department of Cardiovascular Surgery, Tokyo Women's Medical University, Tokyo, Japan
2 shared publications- Hideyuki Tomioka
The Department of Cardiovascular Surgery, Heart Institute of Japan, Tokyo Women's Medical University, Tokyo, Japan
1 shared publication Hikaru Ishii
1 shared publicationHiroaki Yusa
1 shared publicationHiromi Kurosawa
1 shared publication
Latest Publications
- Open Access
- 13 January 2014
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 45 (2) , 400
Corrigendum to 'The next generation of fenestrated endografts: results of a clinical trial to support an expanded indication for aortic arch aneurysm treatment' [Eur J Cardiothorac Surg 2013;44:e156-63]
The authors regret that an error has appeared in the original version of the article. In the reference list, the references 2 and 3 were interchanged. The correct order should be:
- 13 January 2014
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 45 (2) , 400
Open AccessCorrigendum to 'The next generation of fenestrated endografts: results of a clinical trial to support an expanded indication for aortic arch aneurysm treatment' [Eur J Cardiothorac Surg 2013;44:e156-63]
The authors regret that an error has appeared in the original version of the article. In the reference list, the references 2 and 3 were interchanged. The correct order should be:
- Open Access
- 5 May 2013
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 44 (2) , e156-e163
The next generation of fenestrated endografts: results of a clinical trial to support an expanded indication for aortic arch aneurysm treatment
Short- and mid-term data regarding the use of precurved, fenestrated endografts have shown that these devices are both safe and effective in carefully selected patients. The first generation of the product was limited to patients with proximal landing zones (LZs) of >20 mm. The next generation of these endografts has been refined to enable the treatment of patients with shorter proximal seal zones (P < 0.01), in the univariate analysis. In the discriminant analysis, the maximum length of the aneurysm was the only factor that was predictive of Type I endoleaks (73 ± 55 vs 97 ± 59 mm; P < 0.001). The next generation of precurved, fenestrated endografts shows promise as devices for aortic arch aneurysms with a <15-mm proximal sealing zone. These devices have a significant advantage in cases where the LZ has a short neck. However, more refinement is necessary to prevent Type I endoleaks, so that these devices can be used with aortic vessels with large proximal diameters and large aneurysms.
- 5 May 2013
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 44 (2) , e156-e163
Open AccessThe next generation of fenestrated endografts: results of a clinical trial to support an expanded indication for aortic arch aneurysm treatment
Short- and mid-term data regarding the use of precurved, fenestrated endografts have shown that these devices are both safe and effective in carefully selected patients. The first generation of the product was limited to patients with proximal landing zones (LZs) of >20 mm. The next generation of these endografts has been refined to enable the treatment of patients with shorter proximal seal zones (P < 0.01), in the univariate analysis. In the discriminant analysis, the maximum length of the aneurysm was the only factor that was predictive of Type I endoleaks (73 ± 55 vs 97 ± 59 mm; P < 0.001). The next generation of precurved, fenestrated endografts shows promise as devices for aortic arch aneurysms with a <15-mm proximal sealing zone. These devices have a significant advantage in cases where the LZ has a short neck. However, more refinement is necessary to prevent Type I endoleaks, so that these devices can be used with aortic vessels with large proximal diameters and large aneurysms.
- 1 October 2009
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 36 (4) , 771-772
Aortic valve replacement in Behcet's disease: surgical modification to prevent valve detachment
Aortic valve replacement (AVR) for aortic regurgitation due to Behcet's disease is often complicated with valve detachment. In our institute, between 1981 and 2006, five consecutive patients with aortic regurgitation secondary to Behcet's disease underwent valve detachment after initial surgery. A novel modification of AVR termed 'subannular ring reinforcement technique' was introduced to prevent valve detachment. We performed AVR with this new manoeuvre in three patients. No prosthetic valve detachment was noted after a mean period of 3+/-1.8 years (range: 1.5-5.1 years). In this technique, we put a ring-shaped prosthetic graft in subannular position and sandwiched the aortic valve annulus between the prosthetic valve and graft with vertical mattress sutures. We consider that the subannular ring may be effective in distributing the stress to the annulus and the vertical mattress suture may help in fixing the prosthesis to annulus tissue rigidly.
- 1 October 2009
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 36 (4) , 771-772
Aortic valve replacement in Behcet's disease: surgical modification to prevent valve detachment
Aortic valve replacement (AVR) for aortic regurgitation due to Behcet's disease is often complicated with valve detachment. In our institute, between 1981 and 2006, five consecutive patients with aortic regurgitation secondary to Behcet's disease underwent valve detachment after initial surgery. A novel modification of AVR termed 'subannular ring reinforcement technique' was introduced to prevent valve detachment. We performed AVR with this new manoeuvre in three patients. No prosthetic valve detachment was noted after a mean period of 3+/-1.8 years (range: 1.5-5.1 years). In this technique, we put a ring-shaped prosthetic graft in subannular position and sandwiched the aortic valve annulus between the prosthetic valve and graft with vertical mattress sutures. We consider that the subannular ring may be effective in distributing the stress to the annulus and the vertical mattress suture may help in fixing the prosthesis to annulus tissue rigidly.