AAAbid Assali

Abid Assali

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Abid Assali has a total of 100 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • THE ASSOCIATION OF CORONARY ARTERY DISEASE SEVERITY AND PRE PROCEDURAL COMPLETENESS OF REVASCLARIZATION ON MORTALITY IN PATIENTS UNDERGOING TRANSCATHETER AORTIC VALVE REPLACEMENT

    by Guy Witberg, Ehud Regev, Shmuel Chen, Abid Assali, Issi Barbash, David Planer, Hana Vaknin Assa, Victor Guetta, Vicky Zeniou, Katia Orvin, et al.

    • 1 February 2017
      • Vol. 29  (2) , 69-74

    Comparative Matched Outcome of Evolut-R vs CoreValve Transcatheter Aortic Valve Implantation.

    by Uri Landes, Tamir Bental, Alon Barsheshet, Abid Assali, Hana Vaknin Assa, Amos Levi, Katia Orvin, Ran Kornowski

    The Evolut-R (Medtronic, Inc) is a transcatheter aortic valve implantation (TAVI) system that was built on the well-established foundation of Medtronic's CoreValve device platform. Although already in extensive clinical utilization, it is unknown if the Evolut-R improves TAVI outcomes. Herein, we compared TAVI outcomes of the Evolut-R and CoreValve devices. A propensity score 1:1 matching was conducted on 358 Evolut-R patients (n = 75) and CoreValve patients (n = 283). Thirty-day outcomes were compared using Valve Academic Research Consortium (VARC)-2 criteria. A combined 30-day endpoint including all-cause death, stroke, major vascular complication, major bleeding, implantation failure, paravalvular leak (PVL) ≥ moderate, and new pacemaker implantation was also tested. The final study group included 146 patients (73 Evolut-R; 73 CoreValve). Post matching, baseline characteristics were similar between the two groups. Mean patient age was 82 ± 6 years, mean STS score was 5.2 ± 3.8, 72% were female, and 17% were deemed frail. Implantation success reached 99% with Evolut-R and 94% with CoreValve (P=.10). Both groups had low periprocedural stroke/myocardial infarction/mortality rates and there was also no difference in 30-day vascular complications (P=.18), bleeding (P=.37), PVL (P=.24), and new pacemaker (P=.14). The combined outcome rate was 24% with Evolut-R and 37% with CoreValve (P=.10). This study indicates that the efficacy and safety of the self-expandable second-generation Evolut-R transcatheter valve is at least comparable with the first-generation CoreValve. The observed improved performance in correct positioning of a single valve and the numerically lower chance to suffer a combined TAVI endpoint needs further investigation.


    • 1 July 2016
      • Vol. 18  (7) , 318-385

    Insights from 2D and 3D Quantitative Angiographic Assessment of Bioresorbable Everolimus-Eluting Vascular Scaffolds.

    by Guy Witberg, Ifat Lavi, Hana Vaknin Assa, Katia Orvin, Abid Assali, Ran Kornowski

    Bioresorbable vascular scaffold (BVS) is a promising technology that potentially offers several advantages over contemporary coronary drug-eluting stents (DES). Crucial to BVS implantation is the correct choice of scaffold size (diameter and length) in order to avoid "geographic miss" in length, provide the maximal support to the vessel wall, and avoid leaving "free-floating" foreign material in the coronary vasculature. To assess the optimal method for measuring coronary stenosis prior to BVS implantation. We compared the performance of two quantitative coronary angiography assessment (QCA) techniques: two dimensional real-time QCA (2D-QCA) and offline 3D QCA (3D-QCA) for the evaluation of coronary lesions in patients enrolled in a multicenter randomized controlled trial of BVS vs. metallic stents, by calculating the weighted kappa value for agreement regarding optimal BVS size with the reference method - CoreLab offline 2D-QCA measurements..In addition, we collected 2 year clinical outcomes (death/myocardial infarction/repeat revascularization/scaffold thrombosis) in BVS-implanted patients. In 17 patients with available CoreLab data, the weighted kappa for agreement for 3D-QCA was significantly better than for 2D-QCA (0.90, 95%CI 0.72-1.00 vs. 0.439, 95%CI 0.16-0.77). The rate of clinical events at 2 years was low (9.5%). Initial experience in a small group of carefully selected patients at our institution, suggests that the use of BVS for coronary revascularization is associated with a low rate of adverse events in suitable patients. 3D-QCA may be superior to 2D-QCA analysis in terms of reproducibility, and results in more patients receiving optimal size BVS.

  • AORTIC VALVE GRADIENT AND CLINICAL OUTCOME IN PATIENTS UNDERGOING TRANSCATHETER AORTIC VALVE REPLACEMENT FOR SEVERE AORTIC STENOSIS

    by Guy Witberg, Alon Barsheshet, Hana Vaknin-Assa, Abid Assali, Yaron Shapira, Tuvya Ben-Gal, Alik Sagie, Ran Kornowski

    • 1 March 2016
      • Vol. 28  (3) , 88-91

    Efficacy and Safety of Novel NovaCross Microcatheter for Chronic Total Occlusions: First-in-Human Study.

    by Simon Walsh, Dariusz Dudek, Leszek Bryniarski, Abid Assali, Haim Danenberg, Chaim Lotan, Colm Hanratty, Piotr Wilkołek, Ran Kornowski

    The aim of this first-in-human (FIH) study was to evaluate the efficacy and safety of the novel NovaCross microcatheter system in eligible consecutive patients with chronic total occlusion (CTO). CTOs remain the most challenging lesion subset in percutaneous coronary intervention (PCI). Failure to cross to the distal true lumen with the guidewire is one of the major causes of procedural failure in CTO-PCI. The NovaCross microcatheter (Nitiloop, Ltd) is designed to improve antegrade recanalization success. This study was a prospective, non-randomized, FIH investigational study. Patients with total occlusion of a coronary artery determined to be more than 3 months old and accepted for coronary CTO-PCI with an intended antegrade strategy were enrolled. Twenty-four patients were enrolled in this study. Despite the high complexity of the lesions (including 80% J-CTO score ≥3 and 50% of the cases having had a previous failed CTO-PCI attempt), technical success was 81.8%. No patients reported any major adverse cardiac event up to and including 30 days post procedure. In this FIH study, the NovaCross microcatheter exhibited the potential to stabilize guidewires and enhance crossing of coronary CTO lesions.

  • Effects of prasugrel pretreatment on angiographic myocardial perfusion parameters in patients with ST-elevation myocardial infarction undergoing primary percutaneous coronary intervention

    by Leor Perl, Liat Sasson, Adaya Weissler-Snir, Gabriel Greenberg, Hana Vaknin-Assa, Ran Kornowski, Abid Assali, Eli I. Lev

    Prasugrel is a third-generation thienopyridine, with significant pharmacodynamic and clinical advantages over clopidogrel. There are few data on the effects of prasugrel therapy, as compared with clopidogrel, in terms of perfusion during percutaneous coronary intervention (PCI), in patients with ST-elevation myocardial infarction (STEMI). A total of 128 patients with STEMI, pretreated with prasugrel 60 mg loading dose (mean age=55.9±9.1; 10.9% were women and 18.0% had diabetes), were compared with 128 propensity-matched patients pretreated with clopidogrel 600 mg (mean age=58.7±10.7; 10.2% were women and 19.5% had diabetes) for the primary endpoint of thrombolysis in myocardial infarction (TIMI) flow and myocardial blush grade at completion of the PCI. Secondary endpoints included the combined sum of major adverse events: death, reinfarction or target vessel revascularization at 1 year. Mean TIMI flow grade pre-PCI was similar between the two groups (1.31±1.3 in the prasugrel group and 1.30±1.2 in the clopidogrel group, P=0.96). However, after intervention, it was higher in the prasugrel group (2.94±0.24 vs. 2.84±0.37, respectively, P=0.016), as was myocardial blush (2.70±0.76 vs. 2.31±0.52, respectively, P<0.001). The percentage of TIMI 3 after intervention was also higher in the prasugrel group (97.70 vs. 90.60%, P=0.02). The combined rate of major adverse events at 1 year (8.7 vs. 11.6%, P=0.11), as well as total mortality (3.1±5.6 vs. 4.7±9.1%, P=0.52), did not differ between the two groups. In patients with STEMI undergoing primary PCI, pretreatment with prasugrel resulted in better angiographic perfusion results, as compared with pretreatment with clopidogrel.


    • 15 July 2015
      • Vol. 27  (10) , 475-80

    Efficacy and Safety of Transcatheter Aortic Valve Implantation in Aortic Stenosis Patients With Extreme Age.

    by Katia Orvin, Abid Assali, Hana Vaknin-Assa, Amos Levi, Gabi Greenberg, Pablo Codner, Yaron Shapira, Alex Sagie, Ran Kornowski

    To investigate the in-hospital and long-term outcomes of patients at extreme age with severe symptomatic aortic stenosis (AS) who underwent transcatheter aortic valve implantation (TAVI). A total of 276 consecutive patients with a mean age of 82.2 ± 5.0 years with severe symptomatic AS underwent TAVI at our institute. We evaluated periprocedural, in-hospital, and long-term outcomes in all patients aged ≥87 years (the highest 20th percentile of age distribution) and compared them with the less elderly patients. The extremely aged group included 58 patients (21%) ≥87 years (mean age, 89.0 ± 1.9 years; 67.2% women). Baseline EuroSCOREs and STS scores were 19.6 ± 11.2% and 9.4 ± 5.0%, respectively. Nineteen patients (34.5%) were considered frail. Following TAVI, all patients regained New York Heart Association class 1-2 functional capacity. The main periprocedural and in-hospital complications were minor vascular complications, bleeding requiring blood transfusions, and the need for permanent pacemaker. None of the patients suffered from clinical stroke. In comparison to the less elderly patients, there were no significant differences in the rates of periprocedural, in-hospital complications or long-term survival (log rank, 0.87). Meticulously selected patients at extreme age benefit from TAVI with a reasonable overall risk, which does not impact the overall survival or functional status.


    • 1 July 2015
      • Vol. 154  (7) , 423-5, 470

    [Re-implantation of a mitraclip device in a patient with recurrent mitral regurgitation].

    by Leor Perl, Abid Assali, Hana Vaknin-Assa, Yaron Shapira, Mordehay Vaturi, Alex Sagie, Ran Kornowski

    Mitral regurgitation is a common disease in patients with cardiomyopathies, constituting poor prognosis when present. In patients with an increased risk for surgery, a minimally-invasive, percutaneous procedure currently exists, in the form of an edge-to-edge repair technique using the MitraClip device. This approach allows for great flexibility in specific situations, such as in the addition of another clip when necessary, either during the procedure or after a follow-up period. The following case study depicts the course of therapy for a patient with ischemic cardiomyopathy and severe bi-ventricular failure. The patient was implanted with a MitraClip device five months before the current event, and now presents with clinical deterioration, and a renewed mitral valve insufficiency.

    • 1 July 2015
      • Vol. 24  (4) , 439-44

    The Impact of Transcatheter Aortic Valve Implantation on Mitral Regurgitation Regression in High-Risk Patients with Aortic Stenosis.

    by Leor Perl, Mordehay Vaturi, Abid Assali, Alexander Sagie, Adaya Weissler-Snir, Pablo Codner, Katia Orvin, Hana Vaknin-Assa, Yaron Shapira, Ran Kornowski

    In patients with aortic stenosis, mitral regurgitation (MR) is a common finding. Little is known regarding outcomes of MR in patients undergoing transcatheter aortic valve implantation (TAVI). The study aim was to characterize the short- and mid-term impact of the TAVI procedure on MR grade. A total of 261 patients (59% females; mean age 82.1 +/- 6.9 years) undergoing TAVI was assessed for rates of significant MR and the severity of MR at baseline, and at one month and six months after the procedure. In patients with moderate MR or above at baseline (n = 26, 10% of the cohort), there was a mean reduction in grade of 1.5 +/- 1.1 and 1.8 +/- 1.4 after one and six months, respectively (p < 0.01). Reduction in MR grade (1+) at six months was identified in 54.1% (40/74) of patients with mild-moderate MR or greater, and in 88.5% (23/26) of those with moderate MR or above, and was associated with an improved NYHA functional class (correlation coefficient r = -0.294, p < 0.001). Multivariate analysis identified low pulmonary pressure and tricuspid regurgitation as independent predictors of improvements in MR. Among the present cohort of patients undergoing TAVI, those with MR at baseline showed an improvement in the severity of their MR. Patients with moderate MR regurgitation or above demonstrated the greatest improvement.


    • 1 June 2015
      • Vol. 17  (6) , 360-4

    A Comparative Matched Analysis of Clinical Outcomes between Transradial versus Transfemoral Percutaneous Coronary Intervention.

    by Gabriel Greenberg, Tamir Bental, Eli I Lev, Abid Assali, Hanna Vaknin-Assa, Ran Kornowski

    Several trials support the transradial route of percutaneous coronary intervention (PCI) since it reduces access-site vascular complications and bleeding. To examine the effects of transradial interventions (TRI) on clinical outcomes in a 'real-world' cohort of patients undergoing PCI. We analyzed 4873 consecutive patients who underwent PCI at a tertiary center and identified 373 patients who underwent TRI. Patients (radial vs. femoral) were compared using a propensity score analysis to best match between groups. Outcome parameters included total mortality, myocardial infarction (MI), repeat target vessel revascularization (TVR) rates, length of hospitalization and AHt/Hb/creatinine values during hospitalization. These were evaluated at 6 months and 1 to 3 years after PCI. The rates of major adverse cardiovascular event (MACE) and its constituents were similar in the transradial vs. transfemoral groups at all time intervals: 6.7% vs. 5.5% at 6 months, 10.3% vs. 10% at 1 year, 15.7% vs. 15% at 2 years, 15.7% vs. 16% at 3 years, respectively (P = 0.6). The length of hospitalization was shorter in the TRI group (2.87 days ± 2.04 vs. 3.3 days ± 3.12, P = 0.023). We did not find significant differences between the groups in the mean AHt/Hb/creatinine values during the hospitalization course. In a real-world setting of PCI, the TRI route of PCI is as safe and efficient as the femoral approach. TRI is associated with shorter duration of hospitalization.