Shahid M. Hussain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shahid M. Hussain has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Jan N. M. Ijzermans
2 shared publicationsPieter E. Zondervan
2 shared publicationsRob A. de Man
2 shared publicationsWim C.J. Hop
Department of Epidemiology and Biostatistics, Erasmus MC, Rotterdam, The Netherlands
2 shared publicationsDavid D.E. Zimmerman
1 shared publicationDonald G Mitchell
1 shared publication
Latest Publications
- Open Access
- 18 February 2005
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 21 (3) , 219-229
Can a single‐shot black‐blood T2‐weighted spin‐echo echo‐planar imaging sequence with sensitivity encoding replace the respiratory‐triggered turbo spin‐echo sequence for the liver? an optimization and feasibility study
Purpose To optimize and assess the feasibility of a single‐shot black‐blood T2‐weighted spin‐echo echo‐planar imaging (SSBB‐EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2‐weighted turbo spin‐echo (TSE) sequence. Materials and Methods Six volunteers and 16 patients were scanned at 1.5T (Philips Intera). In the volunteer study, we optimized the SSBB‐EPI sequence by interactively changing the parameters (i.e., the resolution, echo time (TE), diffusion weighting with low b‐values, and polarity of the phase‐encoding gradient) with regard to distortion, suppression of the blood signal, and sensitivity to motion. The influence of each change was assessed. The optimized SSBB‐EPI sequence was applied in patients (N = 16). A number of items, including the overall image quality (on a scale of 1–5), were used for graded evaluation. In addition, the signal‐to‐noise ratio (SNR) of the liver was calculated. Statistical analysis was carried out with the use of Wilcoxon's signed rank test for comparison of the SSBB‐EPI and TSE sequences, with P = 0.05 considered the limit for significance. Results The SSBB‐EPI sequence was improved by the following steps: 1) less frequency points than phase‐encoding steps, 2) a b‐factor of 20, and 3) a reversed polarity of the phase‐encoding gradient. In patients, the mean overall image quality score for the optimized SSBB‐EPI (3.5 (range: 1–4)) and TSE (3.6 (range: 3–4)), and the SNR of the liver on SSBB‐EPI (mean ± SD = 7.6 ± 4.0) and TSE (8.9 ± 4.6) were not significantly different (P > .05). Conclusion Optimized SSBB‐EPI with SENSE proved to be feasible in patients, and the overall image quality and SNR of the liver were comparable to those achieved with the standard respiratory‐triggered T2‐weighted TSE sequence. J. Magn. Reson. Imaging 2005;21:219–229.
- 18 February 2005
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 21 (3) , 219-229
Open AccessCan a single‐shot black‐blood T2‐weighted spin‐echo echo‐planar imaging sequence with sensitivity encoding replace the respiratory‐triggered turbo spin‐echo sequence for the liver? an optimization and feasibility study
Purpose To optimize and assess the feasibility of a single‐shot black‐blood T2‐weighted spin‐echo echo‐planar imaging (SSBB‐EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2‐weighted turbo spin‐echo (TSE) sequence. Materials and Methods Six volunteers and 16 patients were scanned at 1.5T (Philips Intera). In the volunteer study, we optimized the SSBB‐EPI sequence by interactively changing the parameters (i.e., the resolution, echo time (TE), diffusion weighting with low b‐values, and polarity of the phase‐encoding gradient) with regard to distortion, suppression of the blood signal, and sensitivity to motion. The influence of each change was assessed. The optimized SSBB‐EPI sequence was applied in patients (N = 16). A number of items, including the overall image quality (on a scale of 1–5), were used for graded evaluation. In addition, the signal‐to‐noise ratio (SNR) of the liver was calculated. Statistical analysis was carried out with the use of Wilcoxon's signed rank test for comparison of the SSBB‐EPI and TSE sequences, with P = 0.05 considered the limit for significance. Results The SSBB‐EPI sequence was improved by the following steps: 1) less frequency points than phase‐encoding steps, 2) a b‐factor of 20, and 3) a reversed polarity of the phase‐encoding gradient. In patients, the mean overall image quality score for the optimized SSBB‐EPI (3.5 (range: 1–4)) and TSE (3.6 (range: 3–4)), and the SNR of the liver on SSBB‐EPI (mean ± SD = 7.6 ± 4.0) and TSE (8.9 ± 4.6) were not significantly different (P > .05). Conclusion Optimized SSBB‐EPI with SENSE proved to be feasible in patients, and the overall image quality and SNR of the liver were comparable to those achieved with the standard respiratory‐triggered T2‐weighted TSE sequence. J. Magn. Reson. Imaging 2005;21:219–229.
- 1 January 2004
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 24 (1) , 3-17
Focal Nodular Hyperplasia: Findings at State-of-the-Art MR Imaging, US, CT, and Pathologic Analysis
Focal nodular hyperplasia (FNH) is the second most common benign liver tumor after hemangioma. FNH is classified into two types: classic (80% of cases) and nonclassic (20%). Distinction between FNH and other hypervascular liver lesions such as hepatocellular adenoma, hepatocellular carcinoma, and hypervascular metastases is critical to ensure proper treatment. An asymptomatic patient with FNH does not require biopsy or surgery. Magnetic resonance (MR) imaging has higher sensitivity and specificity for FNH than does ultrasonography or computed tomography. Typically, FNH is iso- or hypointense on T1-weighted images, is slightly hyper- or isointense on T2-weighted images, and has a hyperintense central scar on T2-weighted images. FNH demonstrates intense homogeneous enhancement during the arterial phase of gadolinium-enhanced imaging and enhancement of the central scar during later phases. Familiarity with the proper MR imaging technique and the spectrum of MR imaging findings is essential for correct diagno...
- 1 January 2004
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 24 (1) , 3-17
Focal Nodular Hyperplasia: Findings at State-of-the-Art MR Imaging, US, CT, and Pathologic Analysis
Focal nodular hyperplasia (FNH) is the second most common benign liver tumor after hemangioma. FNH is classified into two types: classic (80% of cases) and nonclassic (20%). Distinction between FNH and other hypervascular liver lesions such as hepatocellular adenoma, hepatocellular carcinoma, and hypervascular metastases is critical to ensure proper treatment. An asymptomatic patient with FNH does not require biopsy or surgery. Magnetic resonance (MR) imaging has higher sensitivity and specificity for FNH than does ultrasonography or computed tomography. Typically, FNH is iso- or hypointense on T1-weighted images, is slightly hyper- or isointense on T2-weighted images, and has a hyperintense central scar on T2-weighted images. FNH demonstrates intense homogeneous enhancement during the arterial phase of gadolinium-enhanced imaging and enhancement of the central scar during later phases. Familiarity with the proper MR imaging technique and the spectrum of MR imaging findings is essential for correct diagno...
- 30 April 2003
- Published by Elsevier in Gastroenterology
- Vol. 124 (4) , A557-557
Prospective comparison of hydrogen peroxide-enhanced 3D endoanal ultrasonography and endoanal MR imaging for perianal fistulas
- 30 April 2003
- Published by Elsevier in Gastroenterology
- Vol. 124 (4) , A557-557
Prospective comparison of hydrogen peroxide-enhanced 3D endoanal ultrasonography and endoanal MR imaging for perianal fistulas
- Open Access
- 1 September 2002
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 22 (5) , 1023-1036
Benign versus Malignant Hepatic Nodules: MR Imaging Findings with Pathologic Correlation
According to the currently used nomenclature, there are only two types of hepatocellular nodular lesions: regenerative lesions and dysplastic or neoplastic lesions. Regenerative nodules include monoacinar regenerative nodules, multiacinar regenerative nodules, cirrhotic nodules, segmental or lobar hyperplasia, and focal nodular hyperplasia. Dysplastic or neoplastic nodules include hepatocellular adenoma, dysplastic foci, dysplastic nodules, and hepatocellular carcinoma (HCC). Many of these types of hepatic nodules play a role in the de novo and stepwise carcinogenesis of HCC, which comprises the following steps: regenerative nodule, low-grade dysplastic nodule, high-grade dysplastic nodule, small HCC, and large HCC. State-of-the-art magnetic resonance (MR) imaging facilitates detection and characterization in most cases of hepatic nodules. State-of-the-art MR imaging includes single-shot fast spin-echo imaging, in-phase and opposed-phase T1-weighted gradient-echo imaging, T2-weighted fast spin-echo imagin...
- 1 September 2002
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 22 (5) , 1023-1036
Open AccessBenign versus Malignant Hepatic Nodules: MR Imaging Findings with Pathologic Correlation
According to the currently used nomenclature, there are only two types of hepatocellular nodular lesions: regenerative lesions and dysplastic or neoplastic lesions. Regenerative nodules include monoacinar regenerative nodules, multiacinar regenerative nodules, cirrhotic nodules, segmental or lobar hyperplasia, and focal nodular hyperplasia. Dysplastic or neoplastic nodules include hepatocellular adenoma, dysplastic foci, dysplastic nodules, and hepatocellular carcinoma (HCC). Many of these types of hepatic nodules play a role in the de novo and stepwise carcinogenesis of HCC, which comprises the following steps: regenerative nodule, low-grade dysplastic nodule, high-grade dysplastic nodule, small HCC, and large HCC. State-of-the-art magnetic resonance (MR) imaging facilitates detection and characterization in most cases of hepatic nodules. State-of-the-art MR imaging includes single-shot fast spin-echo imaging, in-phase and opposed-phase T1-weighted gradient-echo imaging, T2-weighted fast spin-echo imagin...
- 1 February 2002
- Published by Elsevier in Magnetic Resonance Imaging Clinics of North America
- Vol. 10 (1) , 31-52
MR imaging of hepatocellular carcinoma
- 1 February 2002
- Published by Elsevier in Magnetic Resonance Imaging Clinics of North America
- Vol. 10 (1) , 31-52
MR imaging of hepatocellular carcinoma
- Open Access
- 29 July 1999
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 10 (2) , 196-201
Biliary hamartomas: Solitary and multiple lesions shown on current MR techniques including gadolinium enhancement
- 29 July 1999
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 10 (2) , 196-201
Open AccessBiliary hamartomas: Solitary and multiple lesions shown on current MR techniques including gadolinium enhancement