GBGérard Brunel

Gérard Brunel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gérard Brunel has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Absence of the lysophosphatidic acid receptor LPA1 results in abnormal bone development and decreased bone mass

    by Isabelle Gennero, Sara Laurencin-Dalicieux, Françoise Conte-Auriol, Fabienne Briand-Mésange, Danielle Laurencin, Jackie Rue, Nicolas Beton, Nicole Malet, Marianne Mus, Akira Tokumura, et al.


  • Radiographic and Histologic Evaluation of a Sinus Augmentation with Composite Bone Graft: A Clinical Case Report

    by Serge Armand, Axel Kirsch, Christophe Sergent, Philippe Kemoun, Gérard Brunel

    The purpose of the present study was to present a clinical case report of a sinus augmentation with a composite bone graft and delayed implant placement with a 5-year follow-up. A 40-year-old female in good health required replacement of her partial upper removable denture with a prosthesis supported by implants. Due to insufficient bone, she had to undergo a sinus lift. A block graft of autogenous chin bone, along with anorganic bovine bone covered by collagen, was utilized. Eight months postsurgery, a biopsy core was taken and 3 endosseous implants were placed. The sinus lift and implantation site are illustrated with clinical, radiological, and histological data. The discussion covers the problems raised by the choice of the surgical technique, grafting material, and immediate or delayed placement of the appropriate implant design. Our results show that a maxillary sinus augmentation with a composite bone graft is a possible method for creating adequate bone volume before implantation.


  • Bioabsorbable Materials for Guided Bone Regeneration Prior to Implant Placement and 7‐Year Follow‐Up: Report of 14 Cases

    by Gérard Brunel, Daniel Brocard, Jean François Duffort, Edmond Jacquet, Pierre Justumus, Thierry Simonet, Edmond Benqué

    Background: The purpose of the present study was to evaluate the efficacy of a guided bone regeneration (GBR) procedure prior to implant placement and the long‐term outcome of the inserted implants.Methods: Prior to dental implant placement, GBR procedure was performed on 14 patients (mean age 48 years) using a synthetic hydroxyapatite (HA) spacer under a collagen membrane. After a mean healing period of 8 months, bone biopsies were obtained during the placement of 14 implants. The specimens were processed for histology without demineralization in order to assess bone quality and quantity of the regenerated bone.Results: Both the bone density and the resorption degree of HA particles were relatively varied between samples. The different phenotypes of osteoclasts and multinucleated giant cells and the individual host response could partially explain the unpredictable results in terms of bone remodeling and biomaterial resorption. However, the presence of HA particles in the regenerated bone had no influence on the osseointegration of implants presenting a success rate of 86% after a 7‐year observation period.Conclusions: These results confirm the possibility of regenerating bone by means of bioabsorbable materials, assuring at the same time the long‐term success for implants inserted in regenerated sites. J Periodontol 2001;72:257‐264.


    • 1 October 2000
      • Vol. 20  (5) , 520-6

    Histologic analysis of a fractured implant: a case report.

    by G Brunel, S Armand, N Miller, J Rue

    This study presents the histologic analysis of an implant retrieved 14 months after loading because of a fracture in the collar region. The implant (Biovent) was removed with part of the periimplant tissues, and the block was prepared using cutting and grinding equipment to obtain 3 sections approximately 30 microns thick. The examination evidenced a high degree of osseointegration, with a bone-to-implant contact of 74% +/- 13%. The lamellar bone was dense and in close relation with the hydroxyapatite coating of the implant. The connection between the 0.4-mm hydroxyapatite coating and the metal was always very tight. The thickness of the metal at the break point was assessed to be 1.6 mm. Besides the relative weakness of the metal at the neck of the implant, other possible causes of failure are discussed.