RAR. B. Arnesen

R. B. Arnesen

*This is an algorithmically generated author record based on publicly available information.

R. B. Arnesen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • E. von Benzon

    Department of Surgery and Department of Radiology, Hillerød Hospital, Hillerød, Denmark; Department of Gastrointestinal Surgery, Copenhagen University Hospital Rigshospitalet, Copenhagen, Denmark; Department of Gastrointestinal Surgery, Copenhagen University Hospital Herlev, Herlev, Denmark

    3 shared publications
  • H. O. Raaschou

    Department of Surgery and Department of Radiology, Hillerød Hospital, Hillerød, Denmark; Department of Gastrointestinal Surgery, Copenhagen University Hospital Rigshospitalet, Copenhagen, Denmark; Department of Gastrointestinal Surgery, Copenhagen University Hospital Herlev, Herlev, Denmark

    2 shared publications
  • Lars Bo Svendsen

    Department of Surgery and Transplantation, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark

    2 shared publications
  • S. Adamsen

    Department of Surgery and Department of Radiology, Hillerød Hospital, Hillerød, Denmark; Department of Gastrointestinal Surgery, Copenhagen University Hospital Rigshospitalet, Copenhagen, Denmark; Department of Gastrointestinal Surgery, Copenhagen University Hospital Herlev, Herlev, Denmark

    2 shared publications
  • Bodil Ginnerup Pedersen

    Department of Radiology, Aarhus University Hospital, Aarhus, Denmark

    1 shared publication
  • E Von Benzon

    1 shared publication

Latest Publications

  • Diagnostic performance of computed tomography colonography and colonoscopy: a prospective and validated analysis of 231 paired examinations

    by R. B. Arnesen, E. von Benzon, S. Adamsen, L. B. Svendsen, H. O. Raaschou, O. Hart Hansen

    Background: Detection of colorectal tumors with computed tomography colonography (CTC) is an alternative to conventional colonoscopy (CC), and clarification of the diagnostic performance is essential for cost-effective use of both technologies. Purpose: To evaluate the diagnostic performance of CTC compared with CC. Material and Methods: 231 consecutive CTCs were performed prior to same-day scheduled CC. The radiologist and endoscopists were blinded to each other's findings. Patients underwent a polyethylene glycol bowel preparation, and were scanned in prone and supine positions using a single-detector helical CT scanner and commercially available software for image analysis. Findings were validated (matched) in an unblinded comparison with video-recordings of the CCs and re-CCs in cases of doubt. Results: For patients with polyps ⩾5 mm and ⩾10 mm, the sensitivity was 69% (95% CI 58–80%) and 81% (68–94%), and the specificity was 91% (84–98%) and 98% (93–100%), respectively. For detection of polyps ⩾5 mm and ⩾10 mm, the sensitivity was 66% (57–75%) and 77% (65–89%). A flat, elevated low-grade carcinoma was missed by CTC. One cancer relapse was missed by CC, and a cecal cancer was missed by an incomplete CC and follow-up double-contrast barium enema. Conclusion: CC was superior to CTC and should remain first choice for the diagnosis of colorectal polyps. However, for diagnosis of lesions ⩾10 mm, CTC and CC should be considered as complementary methods.


  • Cost-effectiveness of computed tomographic colonography: a prospective comparison with colonoscopy

    by R. B. Arnesen, B. Ginnerup-Pedersen, P. B. Poulsen, E. von Benzon, S. Adamsen, S. Laurberg, O. Hart-Hansen

    Purpose: To estimate the cost-effectiveness of detecting colorectal polyps with computed tomographic colonography (CTC) and subsequent polypectomy with primary colonoscopy (CC), using CC as the alternative strategy. Material and Methods: A marginal analysis was performed regarding 103 patients who had had CTC prior to same-day CC at two hospitals, H-I (n = 53) and H-II (n = 50). The patients were randomly chosen from surveillance and symptomatic study populations (148 at H-I and 231 at H-II). Populations, organizations, and procedures were compared. Cost data on time consumption, medication, and minor equipment were collected prospectively, while data on salaries and major equipment were collected retrospectively. The effect was the (previously published) sensitivities of CTC and CC for detection of colorectal polyps⩾6 mm (H-I, n = 148) or ⩾5 mm (H-II, n = 231). Results: Thirteen patients at each center had at least one colorectal polyp⩾6 mm or ⩾5 mm. CTC was the cost-effective alternative at H-I (€187 vs. €211), while CC was the cost-effective alternative at H-II (€239 vs. €192). The cost-effectiveness (costs per finding) mainly depended on the sensitivity of CTC and CC, but the depreciation of equipment and the staff's use of time were highly influential as well. Conclusion: Detection of colorectal polyps⩾6 mm or ⩾5 mm with CTC, followed by polypectomy by CC, can be performed cost-effectively at some institutions with the appropriate hardware and organization.


  • Missed Lesions and False-Positive Findings on Computed-Tomographic Colonography: a Controlled Prospective Analysis

    by R. B. Arnesen, S. Adamsen, L. B. Svendsen, H. O. Raaschou, E. von Benzon, O. H. Hansen

    Background and Study Aims: The aim of the present study was to analyze the reasons for false findings on computed-tomographic (CT) colonography. Patients and Methods: A total of 100 consecutive CT colonography examinations were carried out before conventional colonoscopies scheduled on the same day. Before the study, an experienced radiologist received training in analyzing CT colonographies. The radiologists and endoscopists were blinded to each others’ findings. The patients received standard polyethylene glycol bowel preparation and were scanned in the prone and supine positions using a helical CT scanner and commercially available software for image analysis. Each pair of examinations was later followed by an unblinded analysis, comparing the CT colonographies with video recordings of the conventional colonographies in order to determine the reasons for tumors being missed or false-positive diagnoses arising on CT colonography. Results: Ninety polyps were detected in 41 patients. For patients with tumors ≥ 5 mm and ≥ 10 mm, the sensitivity was 67 % and 75 %, respectively, and the specificity was 84 % and 95 %, respectively. The most important reasons for the 38 false findings of tumors ≥ 5 mm were perception errors (21 of 38) and misinterpretation of flat lesions in particular, including a high-grade dysplasia and a flat elevated Dukes A carcinoma. Residual stool was frequently the reason for misinterpreting lesions ≥ 10 mm (four of 10). Conclusions: Perception errors were the main reason for false findings of lesions ≥ 5 mm, including one flat malignant lesion. Residual stool caused four of 10 false findings for lesions ≥ 10 mm. Reading CT colonographies requires a high level of expertise, and conventional colonography is still regarded as the gold standard for detecting colorectal lesions.


    • 25 September 2000
      • Vol. 162  (39) , 5221

    [Picture of the month. Colonic adenoma].

    by R B Arnesen, S Adamsen, H O Raaschou, E Von Benzon, O H Hansen