Ki Hean Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ki Hean Kim has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Bumju Kim
Department of Mechanical Engineering, Pohang University of Science and Technology, 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 790-784, South Korea
4 shared publicationsSeunghun Lee
Department of Mechanical Engineering, Pohang University of Science and Technology, 77 Cheongam-ro, Nam-gu, Pohang, Gyeoungbuk 37673, Rep. of Korea
4 shared publicationsYeoreum Yoon
Department of Mechanical Engineering, Pohang University of Science and Technology, 77 Cheongam-ro, Nam-gu, Pohang, Gyeoungbuk 37673, Rep. of Korea
4 shared publicationsCalvin J. Yoon
Department of Integrative Biosciences and Biotechnology, Pohang University of Science and Technology, 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, South Korea
3 shared publicationsHungwon Tchah
Department of Ophthalmology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Rep. of Korea
3 shared publicationsJun Ho Lee
Department of Mechanical Engineering, Pohang University of Science and Technology, 77 Cheongam-ro, Nam-gu, Pohang, Gyeoungbuk 37673, Rep. of Korea
3 shared publications
Latest Publications
- Open Access
- 21 December 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13  (1) , 1-10
Deep learning framework for automated goblet cell density analysis in in-vivo rabbit conjunctiva
Goblet cells (GCs) in the conjunctiva are specialized epithelial cells secreting mucins for the mucus layer of protective tear film and playing immune tolerance functions for ocular surface health. Because GC loss is observed in various ocular surface diseases, GC examination is important for precision diagnosis. Moxifloxacin-based fluorescence microscopy (MBFM) was recently developed for non-invasive high-contrast GC visualization. MBFM showed promise for GC examination by high-speed large-area imaging and a robust analysis method is needed to provide GC information. In this study, we developed a deep learning framework for GC image analysis, named dual-channel attention U-Net (DCAU-Net). Dual-channel convolution was used both to extract the overall image texture and to acquire the GC morphological characteristics. A global channel attention module was adopted by combining attention algorithms and channel-wise pooling. DCAU-Net showed 93.1% GC segmentation accuracy and 94.3% GC density estimation accuracy. Further application to both normal and ocular surface damage rabbit models revealed the spatial variations of both GC density and size in normal rabbits and the decreases of both GC density and size in damage rabbit models during recovery after acute damage. The GC analysis results were consistent with histology. Together with the non-invasive high-contrast imaging method, DCAU-Net would provide GC information for the diagnosis of ocular surface diseases.
- 21 December 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13  (1) , 1-10
Open AccessDeep learning framework for automated goblet cell density analysis in in-vivo rabbit conjunctiva
Goblet cells (GCs) in the conjunctiva are specialized epithelial cells secreting mucins for the mucus layer of protective tear film and playing immune tolerance functions for ocular surface health. Because GC loss is observed in various ocular surface diseases, GC examination is important for precision diagnosis. Moxifloxacin-based fluorescence microscopy (MBFM) was recently developed for non-invasive high-contrast GC visualization. MBFM showed promise for GC examination by high-speed large-area imaging and a robust analysis method is needed to provide GC information. In this study, we developed a deep learning framework for GC image analysis, named dual-channel attention U-Net (DCAU-Net). Dual-channel convolution was used both to extract the overall image texture and to acquire the GC morphological characteristics. A global channel attention module was adopted by combining attention algorithms and channel-wise pooling. DCAU-Net showed 93.1% GC segmentation accuracy and 94.3% GC density estimation accuracy. Further application to both normal and ocular surface damage rabbit models revealed the spatial variations of both GC density and size in normal rabbits and the decreases of both GC density and size in damage rabbit models during recovery after acute damage. The GC analysis results were consistent with histology. Together with the non-invasive high-contrast imaging method, DCAU-Net would provide GC information for the diagnosis of ocular surface diseases.
- Open Access
- 14 July 2023
- Published by Springer Nature in Research Square
Deep Learning Framework for Automated Goblet Cell Density Analysis in In-Vivo Rabbit Conjunctiva
Goblet cells (GCs) in the conjunctiva are specialized epithelial cells secreting mucins on the ocular surface and play important roles for ocular surface health. Because GC loss is observed in various ocular surface diseases, GC examination is important. A non-invasive GC imaging method was recently developed, and a robust analysis is needed to make GC information available. In this study, we developed a deep learning framework for GC image analysis. Dual-channel convolution was used to extract the overall texture of image and to acquire the morphological characteristics of GCs. A global channel attention module was adopted by combining attention algorithms and channel-wise pooling. The module generated an adaptive attention map through matrix multiplication with channel-wise weights and propagated information to strengthen low-level features. DCAU-Net showed 93.1% GC segmentation accuracy and 94.3% GC density estimation accuracy. Further application, both normal and ocular surface damage rabbit models revealed the spatial variations of both GC density and size and the decreases of both GC density and size in damage rabbit models during recovery after acute damage. GC image analysis results were consistent with histology. Together with the non-invasive imaging method, DCAU-Net would provide GC information for the diagnosis of ocular surface diseases.
- 14 July 2023
- Published by Springer Nature in Research Square
Open AccessDeep Learning Framework for Automated Goblet Cell Density Analysis in In-Vivo Rabbit Conjunctiva
Goblet cells (GCs) in the conjunctiva are specialized epithelial cells secreting mucins on the ocular surface and play important roles for ocular surface health. Because GC loss is observed in various ocular surface diseases, GC examination is important. A non-invasive GC imaging method was recently developed, and a robust analysis is needed to make GC information available. In this study, we developed a deep learning framework for GC image analysis. Dual-channel convolution was used to extract the overall texture of image and to acquire the morphological characteristics of GCs. A global channel attention module was adopted by combining attention algorithms and channel-wise pooling. The module generated an adaptive attention map through matrix multiplication with channel-wise weights and propagated information to strengthen low-level features. DCAU-Net showed 93.1% GC segmentation accuracy and 94.3% GC density estimation accuracy. Further application, both normal and ocular surface damage rabbit models revealed the spatial variations of both GC density and size and the decreases of both GC density and size in damage rabbit models during recovery after acute damage. GC image analysis results were consistent with histology. Together with the non-invasive imaging method, DCAU-Net would provide GC information for the diagnosis of ocular surface diseases.
- Open Access
- 3 May 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6  (1) , 25339
In vivo 3D measurement of moxifloxacin and gatifloxacin distributions in the mouse cornea using multiphoton microscopy
Moxifloxacin and gatifloxacin are fourth-generation fluoroquinolone antibiotics used in the clinic to prevent or treat ocular infections. Their pharmacokinetics in the cornea is usually measured from extracted ocular fluids or tissues, and in vivo direct measurement is difficult. In this study multiphoton microscopy (MPM), which is a 3D optical microscopic technique based on multiphoton fluorescence, was applied to the measurement of moxifloxacin and gatifloxacin distribution in the cornea. Intrinsic multiphoton fluorescence properties of moxifloxacin and gatifloxacin were characterized, and their distributions in mouse cornea in vivo were measured by 3D MPM imaging. Both moxifloxacin and gatifloxacin had similar multiphoton spectra, while moxifloxacin had stronger fluorescence than gatifloxacin. MPM imaging of mouse cornea in vivo showed (1) moxifloxacin had good penetration through the superficial corneal epithelium, while gatifloxacin had relatively poor penetration, (2) both ophthalmic solutions had high intracellular distribution. In vivo MPM results were consistent with previous studies. This study demonstrates the feasibility of MPM as a method for in vivo direct measurement of moxifloxacin and gatifloxacin in the cornea.
- 3 May 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6  (1) , 25339
Open AccessIn vivo 3D measurement of moxifloxacin and gatifloxacin distributions in the mouse cornea using multiphoton microscopy
Moxifloxacin and gatifloxacin are fourth-generation fluoroquinolone antibiotics used in the clinic to prevent or treat ocular infections. Their pharmacokinetics in the cornea is usually measured from extracted ocular fluids or tissues, and in vivo direct measurement is difficult. In this study multiphoton microscopy (MPM), which is a 3D optical microscopic technique based on multiphoton fluorescence, was applied to the measurement of moxifloxacin and gatifloxacin distribution in the cornea. Intrinsic multiphoton fluorescence properties of moxifloxacin and gatifloxacin were characterized, and their distributions in mouse cornea in vivo were measured by 3D MPM imaging. Both moxifloxacin and gatifloxacin had similar multiphoton spectra, while moxifloxacin had stronger fluorescence than gatifloxacin. MPM imaging of mouse cornea in vivo showed (1) moxifloxacin had good penetration through the superficial corneal epithelium, while gatifloxacin had relatively poor penetration, (2) both ophthalmic solutions had high intracellular distribution. In vivo MPM results were consistent with previous studies. This study demonstrates the feasibility of MPM as a method for in vivo direct measurement of moxifloxacin and gatifloxacin in the cornea.
- Open Access
- 26 January 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 7  (2) , 677-687
Comparison of reflectance confocal microscopy and two-photon second harmonic generation microscopy in fungal keratitis rabbit model ex vivo
Fungal keratitis is an infection of the cornea by fungal pathogens. Diagnosis methods based on optical microscopy could be beneficial over the conventional microbiology method by allowing rapid and non-invasive examination. Reflectance confocal microscopy (RCM) and two-photon second harmonic generation microscopy (TPSHGM) have been applied to pre-clinical or clinical studies of fungal keratitis. In this report, RCM and TPSHGM were characterized and compared in the imaging of a fungal keratitis rabbit model ex vivo. Fungal infection was induced by using two strains of fungi: aspergillus fumigatus and candida albicans. The infected corneas were imaged in fresh condition by both modalities sequentially and their images were analyzed. Both RCM and TPSHGM could detect both fungal strains within the cornea based on morphology: aspergillus fumigatus had distinctive filamentous structures, and candida albicans had round structures superficially and elongated structures in the corneal stroma. These imaging results were confirmed by histology. Comparison between RCM and TPSHGM showed several characteristics. Although RCM and TPSHGM images had good correlation each other, their images were slightly different due to difference in contrast mechanism. RCM had relatively low image contrast with the infected turbid corneas due to high background signal. TPSHGM visualized cells and collagen in the cornea clearly compared to RCM, but used higher laser power to compensate low autofluorescence. Since these two modalities provide complementary information, combination of RCM and TPSHGM would be useful for fungal keratitis detection by compensating their weaknesses each other.
- 26 January 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 7  (2) , 677-687
Open AccessComparison of reflectance confocal microscopy and two-photon second harmonic generation microscopy in fungal keratitis rabbit model ex vivo
Fungal keratitis is an infection of the cornea by fungal pathogens. Diagnosis methods based on optical microscopy could be beneficial over the conventional microbiology method by allowing rapid and non-invasive examination. Reflectance confocal microscopy (RCM) and two-photon second harmonic generation microscopy (TPSHGM) have been applied to pre-clinical or clinical studies of fungal keratitis. In this report, RCM and TPSHGM were characterized and compared in the imaging of a fungal keratitis rabbit model ex vivo. Fungal infection was induced by using two strains of fungi: aspergillus fumigatus and candida albicans. The infected corneas were imaged in fresh condition by both modalities sequentially and their images were analyzed. Both RCM and TPSHGM could detect both fungal strains within the cornea based on morphology: aspergillus fumigatus had distinctive filamentous structures, and candida albicans had round structures superficially and elongated structures in the corneal stroma. These imaging results were confirmed by histology. Comparison between RCM and TPSHGM showed several characteristics. Although RCM and TPSHGM images had good correlation each other, their images were slightly different due to difference in contrast mechanism. RCM had relatively low image contrast with the infected turbid corneas due to high background signal. TPSHGM visualized cells and collagen in the cornea clearly compared to RCM, but used higher laser power to compensate low autofluorescence. Since these two modalities provide complementary information, combination of RCM and TPSHGM would be useful for fungal keratitis detection by compensating their weaknesses each other.
- Open Access
- 16 June 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6  (7) , 2542-2551
Correlation between polarization sensitive optical coherence tomography and second harmonic generation microscopy in skin
Both polarization sensitive optical coherence tomography (PS-OCT) and second harmonic generation (SHG) microscopy are 3D optical imaging methods providing information related to collagen in the skin. PS-OCT provides birefringence information which is due to the collagen composition of the skin. SHG microscopy visualizes collagen fibers in the skin based on their SHG property. These two modalities have been applied to the same skin pathologies associated with collagen changes, but their relationship has not been examined. In this study, we tried to find the relationship by imaging the same skin samples with both modalities. Various parts of the normal rat skin and burn damaged skin were imaged ex vivo, and their images were analyzed both qualitatively and quantitatively. PS-OCT images were analyzed to obtain tissue birefringence. SHG images were analyzed to obtain collagen orientation indices by applying 2D Fourier transform. The skin samples having higher birefringence values had higher collagen orientation indices, and a linear correlation was found between them. Burn damaged skin showed decreases in both parameters compared to the control skins. This relationship between the bulk and microscopic properties of skin may be useful for further skin studies.
- 16 June 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6  (7) , 2542-2551
Open AccessCorrelation between polarization sensitive optical coherence tomography and second harmonic generation microscopy in skin
Both polarization sensitive optical coherence tomography (PS-OCT) and second harmonic generation (SHG) microscopy are 3D optical imaging methods providing information related to collagen in the skin. PS-OCT provides birefringence information which is due to the collagen composition of the skin. SHG microscopy visualizes collagen fibers in the skin based on their SHG property. These two modalities have been applied to the same skin pathologies associated with collagen changes, but their relationship has not been examined. In this study, we tried to find the relationship by imaging the same skin samples with both modalities. Various parts of the normal rat skin and burn damaged skin were imaged ex vivo, and their images were analyzed both qualitatively and quantitatively. PS-OCT images were analyzed to obtain tissue birefringence. SHG images were analyzed to obtain collagen orientation indices by applying 2D Fourier transform. The skin samples having higher birefringence values had higher collagen orientation indices, and a linear correlation was found between them. Burn damaged skin showed decreases in both parameters compared to the control skins. This relationship between the bulk and microscopic properties of skin may be useful for further skin studies.
- Open Access
- 15 June 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6  (7) , 2512-2521
In vivo visualization of skin inflammation by optical coherence tomography and two-photon microscopy
Inflammation is a non-specific immune response to injury intended to protect biological tissue from harmful stimuli such as pathogens, irritants, and damaged cells. In vivo optical tissue imaging has been used to provide spatial and dynamic characteristics of inflammation within the tissue. In this paper, we report in vivo visualization of inflammation in the skin at both cellular and physiological levels by using a combination of label-free two-photon microscopy (TPM) and optical coherence tomography (OCT). Skin inflammation was induced by topically applying lipopolysaccharide (LPS) on the mouse ear. Temporal OCT imaging visualized tissue swelling, vasodilation, and increased capillary density 30 min and 1 hour after application. TPM imaging showed immune cell migration within the inflamed skin. Combined OCT and TPM was applied to obtain complementary information from each modality in the same region of interest. The information provided by each modality were consistent with previous reports about the characteristics of inflammation. Therefore, the combination of OCT and TPM holds potential for studying inflammation of the skin.
- 15 June 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6  (7) , 2512-2521
Open AccessIn vivo visualization of skin inflammation by optical coherence tomography and two-photon microscopy
Inflammation is a non-specific immune response to injury intended to protect biological tissue from harmful stimuli such as pathogens, irritants, and damaged cells. In vivo optical tissue imaging has been used to provide spatial and dynamic characteristics of inflammation within the tissue. In this paper, we report in vivo visualization of inflammation in the skin at both cellular and physiological levels by using a combination of label-free two-photon microscopy (TPM) and optical coherence tomography (OCT). Skin inflammation was induced by topically applying lipopolysaccharide (LPS) on the mouse ear. Temporal OCT imaging visualized tissue swelling, vasodilation, and increased capillary density 30 min and 1 hour after application. TPM imaging showed immune cell migration within the inflamed skin. Combined OCT and TPM was applied to obtain complementary information from each modality in the same region of interest. The information provided by each modality were consistent with previous reports about the characteristics of inflammation. Therefore, the combination of OCT and TPM holds potential for studying inflammation of the skin.
- Open Access
- 7 May 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23  (10) , 12874-12886
Dark-field polarization-sensitive optical coherence tomography
Polarization-sensitive optical coherence tomography (PS-OCT) is a functional OCT providing both structural and birefringent information of the sample, and it has been applied to the studies of various organs having polarization properties. Fiber-based PS-OCT is sensitive to specular reflection from the sample surface, because signal saturation due to the strong specular reflection can make the polarization measurement difficult. We developed a dark-field PS-OCT which can avoid the specular reflection problem. Dark-field PS-OCT was implemented by adapting a hybrid method of Bessel-beam illumination and Gaussian-beam detection, and a PS-OCT method based on passive delay unit (PDU). The new system was characterized in comparison with the conventional Gaussian-beam based method in both polarization components and various samples including the human skin. Dark-field PS-OCT performed as good as the conventional PS-OCT without the specular reflection artifact. Dark-field PS-OCT may be useful in practical situations where the specular reflection is unavoidable.
- 7 May 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23  (10) , 12874-12886
Open AccessDark-field polarization-sensitive optical coherence tomography
Polarization-sensitive optical coherence tomography (PS-OCT) is a functional OCT providing both structural and birefringent information of the sample, and it has been applied to the studies of various organs having polarization properties. Fiber-based PS-OCT is sensitive to specular reflection from the sample surface, because signal saturation due to the strong specular reflection can make the polarization measurement difficult. We developed a dark-field PS-OCT which can avoid the specular reflection problem. Dark-field PS-OCT was implemented by adapting a hybrid method of Bessel-beam illumination and Gaussian-beam detection, and a PS-OCT method based on passive delay unit (PDU). The new system was characterized in comparison with the conventional Gaussian-beam based method in both polarization components and various samples including the human skin. Dark-field PS-OCT performed as good as the conventional PS-OCT without the specular reflection artifact. Dark-field PS-OCT may be useful in practical situations where the specular reflection is unavoidable.
- 1 March 2015
- Published by Elsevier in Experimental Eye Research
- Vol. 132, 101-108
Comparison of confocal microscopy and two-photon microscopy in mouse cornea in vivo
- 1 March 2015
- Published by Elsevier in Experimental Eye Research
- Vol. 132, 101-108
Comparison of confocal microscopy and two-photon microscopy in mouse cornea in vivo
- Open Access
- 14 January 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6  (2) , 524-535
In vivo wide-field reflectance/fluorescence imaging and polarization-sensitive optical coherence tomography of human oral cavity with a forward-viewing probe
We report multimodal imaging of human oral cavity in vivo based on simultaneous wide-field reflectance/fluorescence imaging and polarization-sensitive optical coherence tomography (PS-OCT) with a forward-viewing imaging probe. Wide-field reflectance/fluorescence imaging and PS-OCT were to provide both morphological and fluorescence information on the surface, and structural and birefringent information below the surface respectively. The forward-viewing probe was designed to access the oral cavity through the mouth with dimensions of approximately 10 mm in diameter and 180 mm in length. The probe had field of view (FOV) of approximately 5.5 mm in diameter, and adjustable depth of field (DOF) from 2 mm to 10 mm by controlling numerical aperture (NA) in the detection path. This adjustable DOF was to accommodate both requirements for image-based guiding with high DOF and high-resolution, high-sensitivity imaging with low DOF. This multimodal imaging system was characterized by using a tissue phantom and a mouse model in vivo, and was applied to human oral cavity. Information of surface morphology and vasculature, and under-surface layered structure and birefringence of the oral cavity tissues was obtained. These results showed feasibility of this multimodal imaging system as a tool for studying oral cavity lesions in clinical applications.
- 14 January 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6  (2) , 524-535
Open AccessIn vivo wide-field reflectance/fluorescence imaging and polarization-sensitive optical coherence tomography of human oral cavity with a forward-viewing probe
We report multimodal imaging of human oral cavity in vivo based on simultaneous wide-field reflectance/fluorescence imaging and polarization-sensitive optical coherence tomography (PS-OCT) with a forward-viewing imaging probe. Wide-field reflectance/fluorescence imaging and PS-OCT were to provide both morphological and fluorescence information on the surface, and structural and birefringent information below the surface respectively. The forward-viewing probe was designed to access the oral cavity through the mouth with dimensions of approximately 10 mm in diameter and 180 mm in length. The probe had field of view (FOV) of approximately 5.5 mm in diameter, and adjustable depth of field (DOF) from 2 mm to 10 mm by controlling numerical aperture (NA) in the detection path. This adjustable DOF was to accommodate both requirements for image-based guiding with high DOF and high-resolution, high-sensitivity imaging with low DOF. This multimodal imaging system was characterized by using a tissue phantom and a mouse model in vivo, and was applied to human oral cavity. Information of surface morphology and vasculature, and under-surface layered structure and birefringence of the oral cavity tissues was obtained. These results showed feasibility of this multimodal imaging system as a tool for studying oral cavity lesions in clinical applications.
- 30 September 2013
- Published by The Korean Society of Visualization in Journal of the Korean Society of Visualization
- Vol. 11  (2) , 41-45
Development of line-scanning two-photon microscopy based on spatial and temporal focusing for tryptophan based auto fluorescence imaging
- 30 September 2013
- Published by The Korean Society of Visualization in Journal of the Korean Society of Visualization
- Vol. 11  (2) , 41-45
Development of line-scanning two-photon microscopy based on spatial and temporal focusing for tryptophan based auto fluorescence imaging