C. J. Moger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
C. J. Moger has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
P. Bleuet
European Synchrotron Radiation Facility (ESRF), BP 220, F-38043 Grenoble CEDEX, France
3 shared publicationsR. Barrett
European Synchrotron Radiation Facility (ESRF), BP 220, F-38043 Grenoble CEDEX, France
3 shared publicationsC.P. Winlove
2 shared publicationsC. P. Winlove
School of Physics, University of Exeter, Stocker Road, Exeter, Devon EX4 4QL, UK
1 shared publicationD.A. Bradley
1 shared publicationE. M. Green
School of Physics, University of Exeter, Stocker Road, Exeter, Devon EX4 4QL, UK
1 shared publication
Latest Publications
- 7 January 2009
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 131 (3) , 031008
Cartilage Collagen Matrix Reorientation and Displacement in Response to Surface Loading
An investigation of collagen fiber reorientation, as well as fluid and matrix movement of equine articular cartilage and subchondral bone under compressive mechanical loads, was undertaken using small angle X-ray scattering measurements and optical microscopy. Small angle X-ray scattering measurements were made on healthy and diseased samples of equine articular cartilage and subchondral bone mounted in a mechanical testing apparatus on station ID18F of ESRF, Grenoble, together with fiber orientation analysis using polarized light and displacement measurements of the cartilage matrix and fluid using tracers. At surface pressures of up to approximately 1.5 MPa, there was reversible compression of the tangential surface fibers and immediately subjacent zone. As load increased, deformation in these zones reached a maximum and then reorientation propagated to the radial deep zone. Between surface pressures of 4.8 MPa and 6.0 MPa, fiber orientation above the tide mark rotated 10 deg from the radial direction, with an overall loss of alignment. With further increase in load, the fibers “crimped” as shown by the appearance of subsidiary peaks approximately ±10 deg either side of the principal fiber orientation direction. Failure at higher loads was characterized by a radial split in the deep cartilage, which propagated along the tide mark while the surface zone remained intact. In lesions, the fiber organization was disrupted and the initial response to load was consistent with early rupture of fibers, but the matrix relaxed to an organization very similar to that of the unloaded tissue. Tracer measurements revealed anisotropic solid and fluid displacement, which depended strongly on depth within the tissue.
- 7 January 2009
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 131 (3) , 031008
Cartilage Collagen Matrix Reorientation and Displacement in Response to Surface Loading
An investigation of collagen fiber reorientation, as well as fluid and matrix movement of equine articular cartilage and subchondral bone under compressive mechanical loads, was undertaken using small angle X-ray scattering measurements and optical microscopy. Small angle X-ray scattering measurements were made on healthy and diseased samples of equine articular cartilage and subchondral bone mounted in a mechanical testing apparatus on station ID18F of ESRF, Grenoble, together with fiber orientation analysis using polarized light and displacement measurements of the cartilage matrix and fluid using tracers. At surface pressures of up to approximately 1.5 MPa, there was reversible compression of the tangential surface fibers and immediately subjacent zone. As load increased, deformation in these zones reached a maximum and then reorientation propagated to the radial deep zone. Between surface pressures of 4.8 MPa and 6.0 MPa, fiber orientation above the tide mark rotated 10 deg from the radial direction, with an overall loss of alignment. With further increase in load, the fibers “crimped” as shown by the appearance of subsidiary peaks approximately ±10 deg either side of the principal fiber orientation direction. Failure at higher loads was characterized by a radial split in the deep cartilage, which propagated along the tide mark while the surface zone remained intact. In lesions, the fiber organization was disrupted and the initial response to load was consistent with early rupture of fibers, but the matrix relaxed to an organization very similar to that of the unloaded tissue. Tracer measurements revealed anisotropic solid and fluid displacement, which depended strongly on depth within the tissue.
- 1 June 2007
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 15 (6) , 682-687
Regional variations of collagen orientation in normal and diseased articular cartilage and subchondral bone determined using small angle X-ray scattering (SAXS)
- 1 June 2007
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 15 (6) , 682-687
Regional variations of collagen orientation in normal and diseased articular cartilage and subchondral bone determined using small angle X-ray scattering (SAXS)
- 31 December 2006
- Published by Elsevier in Journal of Biomechanics
- Vol. 39, S452
Mechanical properties of cartilage under load determined using small angle X-ray diffraction (SAXS) and Raman micro-spectrometry
- 31 December 2006
- Published by Elsevier in Journal of Biomechanics
- Vol. 39, S452
Mechanical properties of cartilage under load determined using small angle X-ray diffraction (SAXS) and Raman micro-spectrometry