Hormoz Azizian
Research Subjects
Hormoz Azizian has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
John K. G. Kramer
Research and Development Center Agriculture and Agri‐Food Canada Guelph Ontario N1G 5C9 Canada
7 shared publications- John K. G. Kramer
Guelph Food Research Centre Agriculture & Agri‐Food Canada Guelph ON Canada
4 shared publications - Magdi M. Mossoba
U.S. Food and Drug Administration, Center for Food Safety and Applied Nutrition, Office of Regulatory Science
4 shared publications Ali Reza Fardin‐Kia
Food and Drug Administration, Center for Food Safety and Applied Nutrition, Office of Regulatory Science, College Park, MD, USA
2 shared publicationsJohn K.G. Kramer
Guelph Food Research Center, Agriculture and Agri-Food Canada, 93 Stone Road West, Guelph, Ontario, Canada, N1G 5C9
2 shared publicationsSanjeewa R. Karunathilaka
Food and Drug Administration, Center for Food Safety and Applied Nutrition, Office of Regulatory Science, College Park, MD, USA
2 shared publications
Latest Publications
- 18 March 2021
- Published by Wiley in European Journal of Lipid Science and Technology
- Vol. 123 (5) , 2000288
Clarifications of the Carbonyl and Water Absorptions in Fourier Transform Near Infrared Spectra from Extra Virgin Olive Oil
The Fourier transform near infrared (FT‐NIR) spectrum of extra virgin olive oils (EVOO) shows two minor carbonyl absorptions at 5280 and 5180 cm–1 that has been used to assess their authenticity. To establish components absorbing at 5280 cm–1, volatile aldehydes and ketones, triacylglycerol (TAG), diacylglycerols (DAG), free fatty acids (FFA), phenolics, and water are investigated and sometimes added to refined olive oil (ROO). Except TAG, the remaining carbonyls contribute to 5280 cm–1 by broadening peak. Water absorption is demonstrated by its removal using Na2SO4 or deuterium oxide addition; FT‐NIR spectral changes are reconstituted by water addition. Water absorption depends on being free or complexed with polar compounds in oil. The size of absorption is not related to abundance, but on unique absorption specificity of components; water shows the strongest absorption. Heat removes water and volatiles, leaving behind DAG, FFA, and phenolics, and makes it possible to differentiate absorption of water, volatile and non‐volatile carbonyls. Cloudy olive oils are analyzed using FT‐NIR methodology after warming for 3 min at 50 °C. FT‐NIR index values are replaced by a new calibration model based on correlating gravimetric mass loss of water plus volatiles with spectral changes. The FT‐NIR methodology is expanded to include EVOOs with 15.5% to 21% linoleic acid.Practical Applications: Testing for authenticity of EVOOs remains a challenge because adulterations continue to be a problem due to economic gains. Spectroscopy methods, specifically FT‐NIR, are much preferred to targeted chemical methods because they measure all constituents in products and are non‐destructive and fast. The current universal FT‐NIR methodology assesses 13 different parameters: five major FAs, and the DAG and FFA contents. The FT‐NIR index value measuring the content of moisture plus volatiles is now replaced by a gravimetric determination. The methodology identifies four major types of adulterants, high in oleic acid, linoleic acid, palm olein or ROO. The composition of olive oils makes it necessary to develop five oil‐specific groups, but cloudy samples still need to be clarified by slight warming before measuring. The value of this universal FT‐NIR methodology will increase after being adopted by commercial and in regulatory settings.
- 18 March 2021
- Published by Wiley in European Journal of Lipid Science and Technology
- Vol. 123 (5) , 2000288
Clarifications of the Carbonyl and Water Absorptions in Fourier Transform Near Infrared Spectra from Extra Virgin Olive Oil
The Fourier transform near infrared (FT‐NIR) spectrum of extra virgin olive oils (EVOO) shows two minor carbonyl absorptions at 5280 and 5180 cm–1 that has been used to assess their authenticity. To establish components absorbing at 5280 cm–1, volatile aldehydes and ketones, triacylglycerol (TAG), diacylglycerols (DAG), free fatty acids (FFA), phenolics, and water are investigated and sometimes added to refined olive oil (ROO). Except TAG, the remaining carbonyls contribute to 5280 cm–1 by broadening peak. Water absorption is demonstrated by its removal using Na2SO4 or deuterium oxide addition; FT‐NIR spectral changes are reconstituted by water addition. Water absorption depends on being free or complexed with polar compounds in oil. The size of absorption is not related to abundance, but on unique absorption specificity of components; water shows the strongest absorption. Heat removes water and volatiles, leaving behind DAG, FFA, and phenolics, and makes it possible to differentiate absorption of water, volatile and non‐volatile carbonyls. Cloudy olive oils are analyzed using FT‐NIR methodology after warming for 3 min at 50 °C. FT‐NIR index values are replaced by a new calibration model based on correlating gravimetric mass loss of water plus volatiles with spectral changes. The FT‐NIR methodology is expanded to include EVOOs with 15.5% to 21% linoleic acid.Practical Applications: Testing for authenticity of EVOOs remains a challenge because adulterations continue to be a problem due to economic gains. Spectroscopy methods, specifically FT‐NIR, are much preferred to targeted chemical methods because they measure all constituents in products and are non‐destructive and fast. The current universal FT‐NIR methodology assesses 13 different parameters: five major FAs, and the DAG and FFA contents. The FT‐NIR index value measuring the content of moisture plus volatiles is now replaced by a gravimetric determination. The methodology identifies four major types of adulterants, high in oleic acid, linoleic acid, palm olein or ROO. The composition of olive oils makes it necessary to develop five oil‐specific groups, but cloudy samples still need to be clarified by slight warming before measuring. The value of this universal FT‐NIR methodology will increase after being adopted by commercial and in regulatory settings.
Improvement of the Fourier Transform Near Infrared Method to Evaluate Extra Virgin Olive Oils by Analyzing 1,2‐Diacylglycerols and 1,3‐Diacylglycerols and Adding Unesterified Fatty Acids
Extra virgin olive oils (EVOO) command higher prices because they contain health‐promoting nutrients and desirable sensory characteristics. Many targeted methods have limited success in determining olive oil authenticity. Therefore, attention has been paid to rapid spectroscopic methods that provide the composition of multiple components. A Fourier transform near infrared (FT‐NIR) method was reported that identified five major fatty acids and volatiles in EVOO, plus four models that identify common adulterants and their content. However, it did not include diacylglycerol (DAG) and unesterified fatty acids (FFA) known to be associated with freshness of the oil. The newly improved FT‐NIR method now includes 1,2‐DAG and 1,3‐DAG models based on the DAG isomer content in freshly prepared EVOO, and a FFA model based on quantitative addition of oleic acid. The new FT‐NIR method was used to reassess previously used EVOO products to evaluate their freshness. Based on these results and review of the published data, we propose several revisions to the EVOO regulation: limit FFA to ≤0.5%, include 1,2‐DAG and 1,3‐DAG in standard, place no limit on 1,2‐DAG because it characterizes the oils, set the 1,3‐DAG content to ≤1.0%, and lower the content of 18:2n‐6 to 1.5%.
Improvement of the Fourier Transform Near Infrared Method to Evaluate Extra Virgin Olive Oils by Analyzing 1,2‐Diacylglycerols and 1,3‐Diacylglycerols and Adding Unesterified Fatty Acids
Extra virgin olive oils (EVOO) command higher prices because they contain health‐promoting nutrients and desirable sensory characteristics. Many targeted methods have limited success in determining olive oil authenticity. Therefore, attention has been paid to rapid spectroscopic methods that provide the composition of multiple components. A Fourier transform near infrared (FT‐NIR) method was reported that identified five major fatty acids and volatiles in EVOO, plus four models that identify common adulterants and their content. However, it did not include diacylglycerol (DAG) and unesterified fatty acids (FFA) known to be associated with freshness of the oil. The newly improved FT‐NIR method now includes 1,2‐DAG and 1,3‐DAG models based on the DAG isomer content in freshly prepared EVOO, and a FFA model based on quantitative addition of oleic acid. The new FT‐NIR method was used to reassess previously used EVOO products to evaluate their freshness. Based on these results and review of the published data, we propose several revisions to the EVOO regulation: limit FFA to ≤0.5%, include 1,2‐DAG and 1,3‐DAG in standard, place no limit on 1,2‐DAG because it characterizes the oils, set the 1,3‐DAG content to ≤1.0%, and lower the content of 18:2n‐6 to 1.5%.
- 25 May 2017
- Published by SAGE Publications in NIR News
- Vol. 28 (4) , 6-9
FT-NIR the method of choice to verify the authenticity of extra virgin olive oils
Fourier transform near infrared spectroscopy was recently demonstrated to be an excellent method to evaluate the authenticity and adulteration of extra virgin olive oil. Since this method is matrix dependent, it takes a chemical fingerprint of all the components which sets it apart from the targeted methods. Careful examinations of the Fourier transform near infrared spectra lead to the identification of a minor carbonyl overtone absorption at 5269 cm−1 associated with the volatile fraction in extra virgin olive oil that appears to be a reliable indicator of authenticity. The same spectra were used to identify the fatty acids present in the oil using models based on comparison to accurate GC data. Gravimetric mixtures of extra virgin olive oil with refined edible oils were then prepared to develop PLS1 calibration models to identify possible adulterants and by how much. The great varietal difference in olive oils made it necessary to develop four unique sets of PLS1 calibration models for each extra virgin olive oil variety. As a result, an extra virgin olive oil acceptance specification was established.
- 25 May 2017
- Published by SAGE Publications in NIR News
- Vol. 28 (4) , 6-9
FT-NIR the method of choice to verify the authenticity of extra virgin olive oils
Fourier transform near infrared spectroscopy was recently demonstrated to be an excellent method to evaluate the authenticity and adulteration of extra virgin olive oil. Since this method is matrix dependent, it takes a chemical fingerprint of all the components which sets it apart from the targeted methods. Careful examinations of the Fourier transform near infrared spectra lead to the identification of a minor carbonyl overtone absorption at 5269 cm−1 associated with the volatile fraction in extra virgin olive oil that appears to be a reliable indicator of authenticity. The same spectra were used to identify the fatty acids present in the oil using models based on comparison to accurate GC data. Gravimetric mixtures of extra virgin olive oil with refined edible oils were then prepared to develop PLS1 calibration models to identify possible adulterants and by how much. The great varietal difference in olive oils made it necessary to develop four unique sets of PLS1 calibration models for each extra virgin olive oil variety. As a result, an extra virgin olive oil acceptance specification was established.
Developing FT‐NIR and PLS1 Methodology for Predicting Adulteration in Representative Varieties/Blends of Extra Virgin Olive Oils
It was previously demonstrated that Fourier transform near infrared (FT-NIR) spectroscopy and partial least squares (PLS1) were successfully used to assess whether an olive oil was extra virgin, and if adulterated, with which type of vegetable oil and by how much using previously developed PLS1 calibration models. This last prediction required an initial set of four PLS1 calibration models that were based on gravimetrically prepared mixtures of a specific variety of extra virgin olive oil (EVOO) spiked with adulterants. The current study was undertaken after obtaining a range of EVOO varieties grown in different countries. It was found that all the different types of EVOO varieties investigated belonged to four distinct groups, and each required the development of additional sets of specific PLS1 calibration models to ensure that they can be used to predict low concentrations of vegetable oils high in linoleic, oleic, or palmitic acid, and/or refined olive oil. These four distinct sets of PLS1 calibration models were required to cover the range of EVOO varieties with a linoleic acid content from 1.3 to 15.5 % of total fatty acids. An FT-NIR library was established with 66 EVOO products obtained from California and Europe. The quality and/or purity of EVOO were assessed by determining the FT-NIR Index, a measure of the volatile content of EVOO. The use of these PLS1 calibration models made it possible to predict the authenticity of EVOO and the identity and quantity of potential adulterant oils in minutes.
Developing FT‐NIR and PLS1 Methodology for Predicting Adulteration in Representative Varieties/Blends of Extra Virgin Olive Oils
It was previously demonstrated that Fourier transform near infrared (FT-NIR) spectroscopy and partial least squares (PLS1) were successfully used to assess whether an olive oil was extra virgin, and if adulterated, with which type of vegetable oil and by how much using previously developed PLS1 calibration models. This last prediction required an initial set of four PLS1 calibration models that were based on gravimetrically prepared mixtures of a specific variety of extra virgin olive oil (EVOO) spiked with adulterants. The current study was undertaken after obtaining a range of EVOO varieties grown in different countries. It was found that all the different types of EVOO varieties investigated belonged to four distinct groups, and each required the development of additional sets of specific PLS1 calibration models to ensure that they can be used to predict low concentrations of vegetable oils high in linoleic, oleic, or palmitic acid, and/or refined olive oil. These four distinct sets of PLS1 calibration models were required to cover the range of EVOO varieties with a linoleic acid content from 1.3 to 15.5 % of total fatty acids. An FT-NIR library was established with 66 EVOO products obtained from California and Europe. The quality and/or purity of EVOO were assessed by determining the FT-NIR Index, a measure of the volatile content of EVOO. The use of these PLS1 calibration models made it possible to predict the authenticity of EVOO and the identity and quantity of potential adulterant oils in minutes.
Novel, Rapid Identification, and Quantification of Adulterants in Extra Virgin Olive Oil Using Near‐Infrared Spectroscopy and Chemometrics
A new, rapid Fourier transform near infrared (FT‐NIR) spectroscopic procedure is described to screen for the authenticity of extra virgin olive oils (EVOO) and to determine the kind and amount of an adulterant in EVOO. To screen EVOO, a partial least squares (PLS1) calibration model was developed to estimate a newly created FT‐NIR index based mainly on the relative intensities of two unique carbonyl overtone absorptions in the FT‐NIR spectra of EVOO and other mixtures attributed to volatile (5280 cm−1) and non‐volatile (5180 cm−1) components. Spectra were also used to predict the fatty acid (FA) composition of EVOO or samples spiked with an adulterant using previously developed PLS1 calibration models. Some adulterated mixtures could be identified provided the FA profile was sufficiently different from those of EVOO. To identify the type and determine the quantity of an adulterant, gravimetric mixtures were prepared by spiking EVOO with different concentrations of each adulterant. Based on FT‐NIR spectra, four PLS1 calibration models were developed for four specific groups of adulterants, each with a characteristic FA composition. Using these different PLS1 calibration models for prediction, plots of predicted vs. gravimetric concentrations of an adulterant in EVOO yielded linear regression functions with four unique sets of slopes, one for each group of adulterants. Four corresponding slope rules were defined that allowed for the determination of the nature and concentration of an adulterant in EVOO products by applying these four calibration models. The standard addition technique was used for confirmation.
Novel, Rapid Identification, and Quantification of Adulterants in Extra Virgin Olive Oil Using Near‐Infrared Spectroscopy and Chemometrics
A new, rapid Fourier transform near infrared (FT‐NIR) spectroscopic procedure is described to screen for the authenticity of extra virgin olive oils (EVOO) and to determine the kind and amount of an adulterant in EVOO. To screen EVOO, a partial least squares (PLS1) calibration model was developed to estimate a newly created FT‐NIR index based mainly on the relative intensities of two unique carbonyl overtone absorptions in the FT‐NIR spectra of EVOO and other mixtures attributed to volatile (5280 cm−1) and non‐volatile (5180 cm−1) components. Spectra were also used to predict the fatty acid (FA) composition of EVOO or samples spiked with an adulterant using previously developed PLS1 calibration models. Some adulterated mixtures could be identified provided the FA profile was sufficiently different from those of EVOO. To identify the type and determine the quantity of an adulterant, gravimetric mixtures were prepared by spiking EVOO with different concentrations of each adulterant. Based on FT‐NIR spectra, four PLS1 calibration models were developed for four specific groups of adulterants, each with a characteristic FA composition. Using these different PLS1 calibration models for prediction, plots of predicted vs. gravimetric concentrations of an adulterant in EVOO yielded linear regression functions with four unique sets of slopes, one for each group of adulterants. Four corresponding slope rules were defined that allowed for the determination of the nature and concentration of an adulterant in EVOO products by applying these four calibration models. The standard addition technique was used for confirmation.
- 1 February 2015
- Published by SAGE Publications in NIR News
- Vol. 26 (1) , 15-17
Near Infrared Spectroscopy, a Diverse Analytical Tool with Unlimited Potential for Discoveries!
- 1 February 2015
- Published by SAGE Publications in NIR News
- Vol. 26 (1) , 15-17
Near Infrared Spectroscopy, a Diverse Analytical Tool with Unlimited Potential for Discoveries!
- 9 April 2014
- Published by Wiley in Lipid Technology
- Vol. 26 (4) , 87-89
Application of the non-invasive FT-NIR spectroscopy method to determine the body fat content in humans
- 9 April 2014
- Published by Wiley in Lipid Technology
- Vol. 26 (4) , 87-89
Application of the non-invasive FT-NIR spectroscopy method to determine the body fat content in humans
- 1 March 2014
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 68 (3) , 379-382
First Direct Body Fat Content Measurement during Pregnancy Using Fourier Transform Near-Infrared Spectroscopy
Currently, there are no direct and reliable methods to measure the body fat content of women during pregnancy. Estimates of fat accretion can significantly affect calculations of energy requirements. We report here the first direct measurement of determining the body fat content of two women during pregnancy using the Fourier transform near-infrared spectroscopy (FT-NIR) method. Fourier transform near-infrared spectroscopy was shown to provide comparable results to dual-energy X-ray absorptiometry and magnetic resonance imaging. These latter methods, even though very reliable to measure body fat levels, cannot be used to measure the body fat of women during pregnancy because of health concerns, while FT-NIR poses no health risk. The FT-NIR results showed the percent body fat remained relatively constant throughout pregnancy, but fat mass and fat free mass increased. Fat mass followed an S curve with a maximum increase between 15 to 25 weeks of gestation that was only detected by repeated measurements using the FT-NIR technique. These results demonstrate the value of the FT-NIR method to directly measure the fat content of pregnant women in minutes instead of relying on indirect calculations or taking measurements before and after pregnancy to track gestational fat mass accretion.
- 1 March 2014
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 68 (3) , 379-382
First Direct Body Fat Content Measurement during Pregnancy Using Fourier Transform Near-Infrared Spectroscopy
Currently, there are no direct and reliable methods to measure the body fat content of women during pregnancy. Estimates of fat accretion can significantly affect calculations of energy requirements. We report here the first direct measurement of determining the body fat content of two women during pregnancy using the Fourier transform near-infrared spectroscopy (FT-NIR) method. Fourier transform near-infrared spectroscopy was shown to provide comparable results to dual-energy X-ray absorptiometry and magnetic resonance imaging. These latter methods, even though very reliable to measure body fat levels, cannot be used to measure the body fat of women during pregnancy because of health concerns, while FT-NIR poses no health risk. The FT-NIR results showed the percent body fat remained relatively constant throughout pregnancy, but fat mass and fat free mass increased. Fat mass followed an S curve with a maximum increase between 15 to 25 weeks of gestation that was only detected by repeated measurements using the FT-NIR technique. These results demonstrate the value of the FT-NIR method to directly measure the fat content of pregnant women in minutes instead of relying on indirect calculations or taking measurements before and after pregnancy to track gestational fat mass accretion.
- 1 January 2014
- Published by Elsevier
Contributors
- 7 August 2012
- Published by Wiley in Journal of the American Oil Chemists' Society
- Vol. 89 (12) , 2143-2154
Evaluating the Transferability of FT‐NIR Calibration Models for Fatty Acid Determination of Edible Fats and Oils Among Five Same‐make Spectrometers Using Transmission or Transflection Modes with Different Pathlengths
Fourier transform near‐infrared (FT‐NIR) spectroscopy in conjunction with partial least squares 1 (PLS1) calibration models was previously reported to be an alternative method to GC for the rapid determination of the fatty acid (FA) composition of fats and oils. These calibration models had been developed based on accurate GC data (primary reference method) and observed FT‐NIR spectra. In the present three‐laboratory limited collaborative study, the transferability of these pre‐developed calibration models to four other FT‐NIR spectrometers from the same manufacturer was evaluated. Six samples were selected that provided a wide range of FA contents. Our results indicate that these models were successfully transferable to spectrometers operating in the transflection mode with 2‐ or 4‐mm pathlength fiber optic probes or in the transmission mode using 5‐mm, but not 8‐mm, outer diameter tubes. The predicted FA composition fell within the statistically accepted limits of agreement between FT‐NIR and GC. The FT‐NIR precision data were consistent with those reported in a published GC collaborative study. The application of FT‐NIR to the determination of the total content of SFA, trans FA, MUFA, and PUFA is cost‐effective and potentially suitable for the rapid screening of commercial products for compliance verification with labeling regulations.
- 7 August 2012
- Published by Wiley in Journal of the American Oil Chemists' Society
- Vol. 89 (12) , 2143-2154
Evaluating the Transferability of FT‐NIR Calibration Models for Fatty Acid Determination of Edible Fats and Oils Among Five Same‐make Spectrometers Using Transmission or Transflection Modes with Different Pathlengths
Fourier transform near‐infrared (FT‐NIR) spectroscopy in conjunction with partial least squares 1 (PLS1) calibration models was previously reported to be an alternative method to GC for the rapid determination of the fatty acid (FA) composition of fats and oils. These calibration models had been developed based on accurate GC data (primary reference method) and observed FT‐NIR spectra. In the present three‐laboratory limited collaborative study, the transferability of these pre‐developed calibration models to four other FT‐NIR spectrometers from the same manufacturer was evaluated. Six samples were selected that provided a wide range of FA contents. Our results indicate that these models were successfully transferable to spectrometers operating in the transflection mode with 2‐ or 4‐mm pathlength fiber optic probes or in the transmission mode using 5‐mm, but not 8‐mm, outer diameter tubes. The predicted FA composition fell within the statistically accepted limits of agreement between FT‐NIR and GC. The FT‐NIR precision data were consistent with those reported in a published GC collaborative study. The application of FT‐NIR to the determination of the total content of SFA, trans FA, MUFA, and PUFA is cost‐effective and potentially suitable for the rapid screening of commercial products for compliance verification with labeling regulations.