Frank Niklaus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Frank Niklaus has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Göran Stemme
Department of Micro and Nanosystems, KTH Royal Institute of Technology, Stockholm, Sweden
3 shared publications - Niclas Roxhed
Department of Intelligent Systems, KTH Royal Institute of Technology, Stockholm, Sweden
2 shared publications A C Fischer
Royal Institute of Technology
1 shared publicationB Samel
1 shared publicationEdvard Kälvesten
Royal Institute of Technology
1 shared publicationF Forsberg
Royal Institute of Technology
1 shared publication
Latest Publications
- 12 July 2013
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 23 (8) , 085019
A comparative study of the bonding energy in adhesive wafer bonding
Adhesion energies are determined for three different polymers currently used in adhesive wafer bonding of silicon wafers. The adhesion energies of the polymer off-stoichiometry thiol-ene-epoxy OSTE+ and the nano-imprint resist mr-I 9150XP are determined. The results are compared to the adhesion energies of wafers bonded with benzocyclobutene, both with and without adhesion promoter. The adhesion energies of the bonds are studied by blister tests, consisting of delaminating silicon lids bonded to silicon dies with etched circular cavities, using compressed nitrogen gas. The critical pressure needed for delamination is converted into an estimate of the bond adhesion energy. The fabrication of test dies and the evaluation method are described in detail. The mean bond energies of OSTE+ were determined to be 2.1 and 20 J m−2 depending on the choice of the epoxy used. A mean bond energy of 1.5 J m−2 was measured for mr-I 9150XP.
- 12 July 2013
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 23 (8) , 085019
A comparative study of the bonding energy in adhesive wafer bonding
Adhesion energies are determined for three different polymers currently used in adhesive wafer bonding of silicon wafers. The adhesion energies of the polymer off-stoichiometry thiol-ene-epoxy OSTE+ and the nano-imprint resist mr-I 9150XP are determined. The results are compared to the adhesion energies of wafers bonded with benzocyclobutene, both with and without adhesion promoter. The adhesion energies of the bonds are studied by blister tests, consisting of delaminating silicon lids bonded to silicon dies with etched circular cavities, using compressed nitrogen gas. The critical pressure needed for delamination is converted into an estimate of the bond adhesion energy. The fabrication of test dies and the evaluation method are described in detail. The mean bond energies of OSTE+ were determined to be 2.1 and 20 J m−2 depending on the choice of the epoxy used. A mean bond energy of 1.5 J m−2 was measured for mr-I 9150XP.
- 1 January 2006
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 153 (4) , G291-G295
Adhesive Wafer Bonding Using Partially Cured Benzocyclobutene for Three-Dimensional Integration
Wafer-level three-dimensional integration (3D) is an emerging technology to increase the performance and functionality of integrated circuits (ICs), with adhesive wafer bonding a key step in one of the attractive technology platforms. In such an application, the dielectric adhesive layer needs to be very uniform, and precise wafer-to-wafer alignment accuracy (∼1μm)(∼1μm) of the bonded wafers is required. In this paper we present a new adhesive wafer bonding process that involves partially curing (cross-linking) of the benzocyclobutene (BCB) coatings prior to bonding. The partially cured BCB layer essentially does not reflow during bonding, minimizing the impact of inhomogeneities in BCB reflow under compression and/or any shear forces at the bonding interface. The resultant nonuniformity of the BCB layer thickness after wafer bonding is less than 1% of the average layer thickness, and the wafers shift relative to each other during the wafer bonding process less than 1μm1μm (average) for 200 mm diameter wafers. When bonding two silicon wafers using partially cured BCB, the critical adhesion energy is sufficiently high (⩾14J∕m2)(⩾14J∕m2) for subsequent IC processing.
- 1 January 2006
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 153 (4) , G291-G295
Adhesive Wafer Bonding Using Partially Cured Benzocyclobutene for Three-Dimensional Integration
Wafer-level three-dimensional integration (3D) is an emerging technology to increase the performance and functionality of integrated circuits (ICs), with adhesive wafer bonding a key step in one of the attractive technology platforms. In such an application, the dielectric adhesive layer needs to be very uniform, and precise wafer-to-wafer alignment accuracy (∼1μm)(∼1μm) of the bonded wafers is required. In this paper we present a new adhesive wafer bonding process that involves partially curing (cross-linking) of the benzocyclobutene (BCB) coatings prior to bonding. The partially cured BCB layer essentially does not reflow during bonding, minimizing the impact of inhomogeneities in BCB reflow under compression and/or any shear forces at the bonding interface. The resultant nonuniformity of the BCB layer thickness after wafer bonding is less than 1% of the average layer thickness, and the wafers shift relative to each other during the wafer bonding process less than 1μm1μm (average) for 200 mm diameter wafers. When bonding two silicon wafers using partially cured BCB, the critical adhesion energy is sufficiently high (⩾14J∕m2)(⩾14J∕m2) for subsequent IC processing.
- 24 July 2001
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 11 (5) , 509-513
Wafer-level membrane transfer bonding of polycrystalline silicon bolometers for use in infrared focal plane arrays
- 24 July 2001
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 11 (5) , 509-513
Wafer-level membrane transfer bonding of polycrystalline silicon bolometers for use in infrared focal plane arrays