Andrew W. Md Kirkpatrick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Andrew W. Md Kirkpatrick has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Alexander Ng
From the Departments of Critical Care Medicine and Surgery (A.W.K.) and Anesthesia (R.C.), Foothills Medical Centre, Calgary, Alberta, Canada, Section of Trauma Services (N.G., D.R., B.L., J.C., R.K.S.) and Perfusion Services (D.N.), Vancouver Hospital and Health Sciences Centre, Vancouver, British Columbia, Canada, and Trauma Services, Auckland Hospital (A.N.), Auckland, New Zealand
1 shared publicationAnna M. Ledgerwood
1 shared publicationBernard Md Lawless
From the Departments of Critical Care Medicine and Surgery (A.W.K.) and Anesthesia (R.C.), Foothills Medical Centre, Calgary, Alberta, Canada, Section of Trauma Services (N.G., D.R., B.L., J.C., R.K.S.) and Perfusion Services (D.N.), Vancouver Hospital and Health Sciences Centre, Vancouver, British Columbia, Canada, and Trauma Services, Auckland Hospital (A.N.), Auckland, New Zealand
1 shared publicationCharles E. Lucas
1 shared publicationDavid Cpc Nash
From the Departments of Critical Care Medicine and Surgery (A.W.K.) and Anesthesia (R.C.), Foothills Medical Centre, Calgary, Alberta, Canada, Section of Trauma Services (N.G., D.R., B.L., J.C., R.K.S.) and Perfusion Services (D.N.), Vancouver Hospital and Health Sciences Centre, Vancouver, British Columbia, Canada, and Trauma Services, Auckland Hospital (A.N.), Auckland, New Zealand
1 shared publicationDavid Ross Md Brown
From the Departments of Critical Care Medicine and Surgery (A.W.K.) and Anesthesia (R.C.), Foothills Medical Centre, Calgary, Alberta, Canada, Section of Trauma Services (N.G., D.R., B.L., J.C., R.K.S.) and Perfusion Services (D.N.), Vancouver Hospital and Health Sciences Centre, Vancouver, British Columbia, Canada, and Trauma Services, Auckland Hospital (A.N.), Auckland, New Zealand
1 shared publication
Latest Publications
- 1 September 2003
- Published by Wolters Kluwer Health
- Vol. 55 (3) , 399-406
Intra-abdominal Complications after Surgical Repair of Small Bowel Injuries: An International Review
The ideal method of repairing serious small bowel injuries remains unknown. Prior reports suggest a higher rate of enteric anastomotic-related complications (EACs) with stapled posttraumatic bowel anastomosis but did not specifically focus on the small bowel or clarify fully the actual anastomotic construction. This was a retrospective review of patients requiring surgical repair of small bowel perforations at a Level I urban American center (Detroit Receiving Hospital [DRH]) and a Canadian provincial trauma center (Vancouver Hospital and Health Sciences Center [VHHSC]). All patients requiring a primary repair and/or resection were included. Anastomoses were hand-sewn, stapled, or combined stapling and sewing with mucosal inversion. Leaks, anastomotic fistulae, and intra-abdominal abscesses were considered specific EACs. A sample size of 53 per group was obtained to detect a 17% difference at alpha = 0.05 (one-sided) and beta = 0.2. Full-thickness small bowel injuries were repaired in 232 patients (DRH, 165; VHHSC, 67). Injuries were penetrating at DRH (91.5%) and blunt at VHHSC (65.7%). Anastomotic repairs in 127 patients (158 anastomotic repairs [DRH, 113; VHHSC, 55]) were 64 (40.5%) stapled, 38 (24.1%) hand-sewn, and 56 (35.4%) combined. Also, 105 patients had 349 primary closures of an injury. Overall, there were 24 EACs. After anastomosis, there were 11 intra-abdominal abscesses: 6 after stapling, 3 after being sewn, and 2 after a combined construction. There were four small bowel anastomotic fistulae: three after stapled-only anastomosis and one after hand-sewing. After enteroenterostomy, the EAC rate was 10.2% per patient, or 8.4% per anastomosis. After primary repairs, one patient had an anastomotic fistula, which closed spontaneously, and 11 had intra-abdominal abscesses, yielding an EAC rate of 10.6% per patient or 3.4% per repair. A primary repair was significantly less likely to be associated with an EAC than any anastomosis (p = 0.035). No method of anastomosis was statistically safer in relation to EACs, whether analyzed by patient, by anastomosis, or by considering primarily either the use of a linear stapler or the principle of inverting the mucosal approximation. Only damage control procedures and associated pancreaticoduodenal injuries were identified as statistically significant predictors using multiple logistic regression analysis. Anastomotic complications after enteroenterostomy or primary repair for trauma are uncommon regardless of the technique, but surgeons must be especially cautious during or after damage control. Primary repairs are desirable, but when anastomosis is unavoidable, the method of repair should reflect that with which the surgeon is the most comfortable.
- 1 September 2003
- Published by Wolters Kluwer Health
- Vol. 55 (3) , 399-406
Intra-abdominal Complications after Surgical Repair of Small Bowel Injuries: An International Review
The ideal method of repairing serious small bowel injuries remains unknown. Prior reports suggest a higher rate of enteric anastomotic-related complications (EACs) with stapled posttraumatic bowel anastomosis but did not specifically focus on the small bowel or clarify fully the actual anastomotic construction. This was a retrospective review of patients requiring surgical repair of small bowel perforations at a Level I urban American center (Detroit Receiving Hospital [DRH]) and a Canadian provincial trauma center (Vancouver Hospital and Health Sciences Center [VHHSC]). All patients requiring a primary repair and/or resection were included. Anastomoses were hand-sewn, stapled, or combined stapling and sewing with mucosal inversion. Leaks, anastomotic fistulae, and intra-abdominal abscesses were considered specific EACs. A sample size of 53 per group was obtained to detect a 17% difference at alpha = 0.05 (one-sided) and beta = 0.2. Full-thickness small bowel injuries were repaired in 232 patients (DRH, 165; VHHSC, 67). Injuries were penetrating at DRH (91.5%) and blunt at VHHSC (65.7%). Anastomotic repairs in 127 patients (158 anastomotic repairs [DRH, 113; VHHSC, 55]) were 64 (40.5%) stapled, 38 (24.1%) hand-sewn, and 56 (35.4%) combined. Also, 105 patients had 349 primary closures of an injury. Overall, there were 24 EACs. After anastomosis, there were 11 intra-abdominal abscesses: 6 after stapling, 3 after being sewn, and 2 after a combined construction. There were four small bowel anastomotic fistulae: three after stapled-only anastomosis and one after hand-sewing. After enteroenterostomy, the EAC rate was 10.2% per patient, or 8.4% per anastomosis. After primary repairs, one patient had an anastomotic fistula, which closed spontaneously, and 11 had intra-abdominal abscesses, yielding an EAC rate of 10.6% per patient or 3.4% per repair. A primary repair was significantly less likely to be associated with an EAC than any anastomosis (p = 0.035). No method of anastomosis was statistically safer in relation to EACs, whether analyzed by patient, by anastomosis, or by considering primarily either the use of a linear stapler or the principle of inverting the mucosal approximation. Only damage control procedures and associated pancreaticoduodenal injuries were identified as statistically significant predictors using multiple logistic regression analysis. Anastomotic complications after enteroenterostomy or primary repair for trauma are uncommon regardless of the technique, but surgeons must be especially cautious during or after damage control. Primary repairs are desirable, but when anastomosis is unavoidable, the method of repair should reflect that with which the surgeon is the most comfortable.
- 1 September 2003
- Published by Wolters Kluwer Health
- Vol. 55 (3) , 407-412
Use of a Centrifugal Vortex Blood Pump and Heparin-Bonded Circuit for Extracorporeal Rewarming of Severe Hypothermia in Acutely Injured and Coagulopathic Patients
Background Standard rewarming methods for posttraumatic hypothermia are ineffective or require systemic heparinization. Centrifugal vortex blood pumps (CVBPs), heparin-bonded circuits, and, potentially, percutaneous access techniques, facilitate the institution of an extracorporeal circulation by noncardiac surgeons. Methods Seven severely hypothermic patients requiring emergent operative intervention were rewarmed intraoperatively using the CVBP with heparin-bonded circuitry. Results Patients were critically ill (average Injury Severity Score of 43.5 [SD, 13.6] for the traumatized patients). The mean temperature before rewarming was 31.5°C (SD, 1.6°C). The CVBP outflow site was the common femoral vein in all patients, with the inflow into the superficial femoral artery (n = 2), contralateral common femoral vein (n = 2), and internal jugular vein (n = 3). The mean time to rewarm to 37°C was 73.3 (SD, 30.5) minutes. All patients survived the initial operation, although the ultimate survival was 43%. Conclusion Noncardiac surgeons can effectively use an extracorporeal rewarming strategy incorporating a heparin-bonded CVBP to rapidly rewarm hypothermic coagulopathic patients undergoing surgery.
- 1 September 2003
- Published by Wolters Kluwer Health
- Vol. 55 (3) , 407-412
Use of a Centrifugal Vortex Blood Pump and Heparin-Bonded Circuit for Extracorporeal Rewarming of Severe Hypothermia in Acutely Injured and Coagulopathic Patients
Background Standard rewarming methods for posttraumatic hypothermia are ineffective or require systemic heparinization. Centrifugal vortex blood pumps (CVBPs), heparin-bonded circuits, and, potentially, percutaneous access techniques, facilitate the institution of an extracorporeal circulation by noncardiac surgeons. Methods Seven severely hypothermic patients requiring emergent operative intervention were rewarmed intraoperatively using the CVBP with heparin-bonded circuitry. Results Patients were critically ill (average Injury Severity Score of 43.5 [SD, 13.6] for the traumatized patients). The mean temperature before rewarming was 31.5°C (SD, 1.6°C). The CVBP outflow site was the common femoral vein in all patients, with the inflow into the superficial femoral artery (n = 2), contralateral common femoral vein (n = 2), and internal jugular vein (n = 3). The mean time to rewarm to 37°C was 73.3 (SD, 30.5) minutes. All patients survived the initial operation, although the ultimate survival was 43%. Conclusion Noncardiac surgeons can effectively use an extracorporeal rewarming strategy incorporating a heparin-bonded CVBP to rapidly rewarm hypothermic coagulopathic patients undergoing surgery.