Walter R. Buchwald
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Walter R. Buchwald has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Gautam Medhi
Department of physics, University of Central Florida, FL 32816
2 shared publications- Janardan Nath
Univ. of Central Florida (United States)
2 shared publications - Justin Cleary
University of Central Florida, Department of Physics, Orlando, Florida, United States
2 shared publications - Justin W. Cleary
Sensors Directorate, AFRL, Wright Patterson AFB, Dayton, OH 45433
2 shared publications - Robert E. Peale
Department of Physics, University of Central Florida, Orlando, USA
2 shared publications Andrew Davis
Solid State Scientific Corporation, 27-2 Wright Rd., Hollis, New Hampshire 03049
1 shared publication
Latest Publications
- 14 March 2013
- Published by Springer Nature in MRS Proceedings
- Vol. 1510
Planar integrated plasmonic mid-IR spectrometer
- 14 March 2013
- Published by Springer Nature in MRS Proceedings
- Vol. 1510
Planar integrated plasmonic mid-IR spectrometer
- 1 May 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8376
Cathodoluminescence of conducting gratings and implications for electron-beam investigations of nano-photonic devices
Cathodoluminescence (CL) spectroscopy is performed on conducting 1- and 2-dimensional gratings of metals, semimetals and semi-conductors of varying periods from 0.5 to 20 microns for a range of grating amplitudes from 0.1 to 4.6 microns. The overall emission spectrum consists of a 400 nm wide band centered at ~600 nm which depends little on the grating period, grating amplitude, material, e-beam energy, or temperature. CL intensity increases and the center wavelength blue shifts with increasing excitation beam current. For the larger amplitude 1-dimensional gratings fringes appear in the emission spectrum, which is due to interference between emission from grating bars and grooves. Surface corrugation is necessary to the emission as none is observed from smooth surfaces. The same band appears weakly in CL of a Cu sample with random ~1 micron surface roughness, but this emission is strongly reduced when the same sample is highly polished. The CL signal appears even when the ~10 nm electron-beam is at least 2 mm away from the grating edge, suggesting electron-beam induced currents are important to the emission, whose precise mechanism remains unclear. Previously suggested mechanisms--electron collision with image charge, transition radiation, surface contamination, and inverse photoemission effect--all fail to explain the observed spectrum and its lack of beam-energy dependence.
- 1 May 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8376
Cathodoluminescence of conducting gratings and implications for electron-beam investigations of nano-photonic devices
Cathodoluminescence (CL) spectroscopy is performed on conducting 1- and 2-dimensional gratings of metals, semimetals and semi-conductors of varying periods from 0.5 to 20 microns for a range of grating amplitudes from 0.1 to 4.6 microns. The overall emission spectrum consists of a 400 nm wide band centered at ~600 nm which depends little on the grating period, grating amplitude, material, e-beam energy, or temperature. CL intensity increases and the center wavelength blue shifts with increasing excitation beam current. For the larger amplitude 1-dimensional gratings fringes appear in the emission spectrum, which is due to interference between emission from grating bars and grooves. Surface corrugation is necessary to the emission as none is observed from smooth surfaces. The same band appears weakly in CL of a Cu sample with random ~1 micron surface roughness, but this emission is strongly reduced when the same sample is highly polished. The CL signal appears even when the ~10 nm electron-beam is at least 2 mm away from the grating edge, suggesting electron-beam induced currents are important to the emission, whose precise mechanism remains unclear. Previously suggested mechanisms--electron collision with image charge, transition radiation, surface contamination, and inverse photoemission effect--all fail to explain the observed spectrum and its lack of beam-energy dependence.
- 29 December 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8173, 81731N-81731
Infrared surface plasmon resonance hosts for sensors
A Surface Plasmon Resonance (SPR) biosensor that operates deep into the infrared (3-11 μm wavelengths) is potentially capable of biomolecule recognition based on both selective binding and characteristic vibrational modes. The goal is to operate such sensors at wavelengths where biological analytes are strongly differentiated by their IR absorption spectra and where the refractive index is increased by dispersion. This will provide enhanced selectivity and sensitivity, when biological analytes bind reversibly to biomolecular recognition elements attached to the sensor surface. This paper investigates potentially useful IR surface plasmon resonances hosts on lamellar gratings formed from various materials with plasma frequencies in the IR wavelength range. These materials include doped semiconductors, CuSnS, graphite and semimetal Bi and Sb. Theoretical results were compared with the experimental results. Penetration depth measurement from the experimental complex permeabilities values shows the tighter mode confinement than for usual Au giving better overlap with biological analytes.
- 29 December 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8173, 81731N-81731
Infrared surface plasmon resonance hosts for sensors
A Surface Plasmon Resonance (SPR) biosensor that operates deep into the infrared (3-11 μm wavelengths) is potentially capable of biomolecule recognition based on both selective binding and characteristic vibrational modes. The goal is to operate such sensors at wavelengths where biological analytes are strongly differentiated by their IR absorption spectra and where the refractive index is increased by dispersion. This will provide enhanced selectivity and sensitivity, when biological analytes bind reversibly to biomolecular recognition elements attached to the sensor surface. This paper investigates potentially useful IR surface plasmon resonances hosts on lamellar gratings formed from various materials with plasma frequencies in the IR wavelength range. These materials include doped semiconductors, CuSnS, graphite and semimetal Bi and Sb. Theoretical results were compared with the experimental results. Penetration depth measurement from the experimental complex permeabilities values shows the tighter mode confinement than for usual Au giving better overlap with biological analytes.
- 1 January 2008
- Published by Springer Nature in MRS Proceedings
- Vol. 1133
Silicides for Infrared Surface Plasmon Resonance Biosensors
- 1 January 2008
- Published by Springer Nature in MRS Proceedings
- Vol. 1133
Silicides for Infrared Surface Plasmon Resonance Biosensors
- 1 January 2008
- Published by Springer Nature in MRS Proceedings
- Vol. 1077
Propagation of high-frequency surface plasmons on gold
- 1 January 2008
- Published by Springer Nature in MRS Proceedings
- Vol. 1077
Propagation of high-frequency surface plasmons on gold