SKSeiji Kawamura

Seiji Kawamura

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Seiji Kawamura has a total of 268 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • DECIGO: the Japanese Space Gravitational Wave Antenna

    by Masaki Ando, Seiji Kawamura, Shuichi Sato, Takashi Nakamura, Kimio Tsubono, Akito Araya, Ikkoh Funaki, Kunihito Ioka, Nobuyuki Kanda, Shigenori Moriwaki, et al.

    A space gravitational wave antenna, DECIGO (DECI-hertz interferometer Gravitational wave Observatory) will provide fruitful insights into the universe, particularly on dark energy, the formation mechanism of supermassive black holes, and the inflation of the universe. In the current pre-conceptual design, DECIGO will be comprised of 4 interferometer units; each interferometer unit will be realized by formation flight of three drag-free spacecraft with 1000 km separation. Since DECIGO will be an extremely challenging mission with high-precision formation flight, it is important to increase the technical feasibility before its planned launch in 2024. Thus, we are planning two milestone missions. DECIGO pathfinder (DPF) is the first milestone mission for DECIGO, and key components for DPF are being tested on ground and in orbit. In this article, we review the conceptual design and current status of DECIGO and DPF.


  • Oscillation frequency stabilization of a semiconductor laser by an indirect modulation method using the Faraday effect

    by Akira Sato, Shinya Maehara, Tomoyuki Uehara, Hideaki Arai, Takashi Sato, Tadashi Tamura, Masashi Ohkawa, Seiji Kawamura

    Scientists throughout the world are seeking to enhance the capabilities of satellite-to-satellite tracking laser interferometer-based optical systems used to measure the alterations in earth's gravitational field that indicate critical changes in the environment. These systems must be able to measure infinitesimal fluctuations in the relative velocities of two satellites, using a light source that oscillates at a level of frequency stability rated better than 10-13 in the square root of the Allan variance. In our experiments, semiconductor laser frequency stabilization that typically requires a brief direct modulation of the laser injection current to obtain an error signal, was accomplished using the Faraday effect of Rb absorption lines. This effectively modulates the reference frequency of the stabilization system, i.e., the Rb absorption line, by modulating the magnetic field applied to the Rb absorption cell, instead of the oscillation frequency of the laser diode. Most recently, we used the Faraday method, in conjunction with a precision temperature controller. For present purposes, we also use the PEAK method, to obtain the most accurate signal possible, comparing it with saturated absorption spectroscopic readings, to determine the noise-source.

  • Open Access

    Optimal location of two laser-interferometric detectors for gravitational wave backgrounds at 100 MHz

    by Atsushi Nishizawa, Seiji Kawamura, Tomotada Akutsu, Koji Arai, Kazuhiro Yamamoto, Daisuke Tatsumi, Erina Nishida, Masa-Aki Sakagami, Takeshi Chiba, Ryuichi Takahashi, et al.


  • Open Access

    The Japanese space gravitational wave antenna; DECIGO

    by S Kawamura, M Ando, T Nakamura, K Tsubono, T Tanaka, I Funaki, N Seto, K Numata, S Sato, K Ioka, et al.


  • The Japanese space gravitational wave antenna - DECIGO

    by S Kawamura, M Ando, T Nakamura, K Tsubono, T Tanaka, I Funaki, N Seto, K Numata, S Sato, K Ioka, et al.


  • Quantum noise in differential-type gravitational-wave interferometer and signal recycling

    by Atsushi Nishizawa, Masa-Aki Sakagami, Seiji Kawamura

    There exists the standard quantum limit (SQL), derived from Heisenberg’s uncertainty relation, in the sensitivity of laser interferometer gravitational-wave (GW) detectors. However, in the context of a full quantum-mechanical approach, SQL can be overcome using the correlation of shot noise and radiation-pressure noise. So far, signal recycling, which is one of the methods to overcome SQL, is considered only in a recombined-type interferometer such as Advanced LIGO, LCGT, and GEO600. In this paper, we investigated quantum noise and the possibility of signal recycling in a differential-type interferometer. As a result, we found that signal recycling is possible and creates at most three dips in the sensitivity curve of the detector due to two coupled resonators. The additional third dip makes it possible to decrease quantum noise at low frequencies, keeping the moderate sensitivity at high frequencies. Then, taking advantage of the third dip and comparing the sensitivity of a differential-type interferometer with that of a next-generation Japanese GW interferometer, LCGT, we found that signal-to-noise ratio (SNR) of inspiral binary is improved by a factor of ≈1.43 for neutron star binary, ≈2.28 for 50M⊙ black hole binary, and ≈2.94 for 100M⊙ black hole binary. We also found that power recycling to increase laser power is possible in our signal-recycling configuration of a detector.


  • Open Access

    Quantum Noise in Differential-type Gravitational-wave Interferometer and Signal Recycling

    by Atsushi Nishizawa, Seiji Kawamura, Masa-Aki Sakagami

    There exists the standard quantum limit (SQL), derived from Heisenberg's uncertainty relation, in the sensitivity of laser interferometer gravitational-wave detectors. However, in the context of a full quantum-mechanical approach, SQL can be overcome using the correlation of shot noise and radiation-pressure noise. So far, signal recycling, which is one of the methods to overcome SQL, is considered only in a recombined-type interferometer such as Advanced-LIGO, LCGT, and GEO600. In this paper, we investigated quantum noise and the possibility of signal recycling in a differential-type interferometer. As a result, we found that signal recycling is possible and creates at most three dips in the sensitivity curve of the detector. Then, taking advantage of the third additional dip and comparing the sensitivity of a differential-type interferometer with that of a next-generation Japanese GW interferometer, LCGT, we found that SNR of inspiral binary is improved by a factor of 1.43 for neutron star binary, 2.28 for 50 M_sun black hole binary, and 2.94 for 100 M_sun black hole binary. We also found that power recycling to increase laser power is possible in our signal-recycling configuration of a detector.

  • Diagonalization of the length sensing matrix of a dual recycled laser interferometer gravitational wave antenna

    by Shuichi Sato, Seiji Kawamura, Keiko Kokeyama, Fumiko Kawazoe, Kentaro Somiya

    Next generation gravitational wave antennas employ resonant sideband extraction (RSE) interferometers with Fabry-Perot cavities in the arms as an optical configuration. In order to realize stable, robust control of the detector system, it is a key issue to extract appropriate control signals for longitudinal degrees of freedom of the complex coupled-cavity system. In this paper, a novel length sensing and control scheme is proposed for the tuned RSE interferometer that is both simple and efficient. The sensing matrix can be well diagonalized, owing to a simple allocation of two rf modulations and to a macroscopic displacement of the cavity mirrors, which cause a detuning of the rf modulation sidebands.


  • Oscillation frequency stabilization of a diode laser for the laser interferometer in a satellite-to-satellite tracking system

    by Shinya Maehara, Hiromichi Kobayashi, Takashi Sato, Masashi Ohkawa, Takeo Maruyama, Taizoh Yoshino, Hiroo Kunimori, Mizuhiko Hosokawa, Hiroyuki Ito, Ying Li, et al.

    Currently in the initial stages of development, the endeavor aims to use satellite-to-satellite tracking laser interferometer-based optical technique, to document fluctuations in earth's gravitational field indicating other critical changes in the environment. This system must be able to measure infinitesimal changes in the relative velocity of the two satellites, using a laser light source, which oscillates at frequency stability better than 10-13 in the square root of the Allan variance. The constraints placed upon the system will ultimately require that the interferometer's light-source be small, lightweight, extremely efficient, durable, and possess high frequency-stability. Present-day technology of a laser diode possesses all of these characteristics, except the last and most critical one; frequency stability. So, our ongoing efforts are all focused on the search for a method of stabilizing the oscillation frequency of the satellite-to-satellite laser-diode light source. We used a Rubidium absorption line as a frequency reference of the frequency stabilization system and the "double optical feedback" method to narrow the laser diode's oscillation linewidth, in order to improve its frequency stability. We have measured the frequency, to determine its degree of stability, by comparing the "femtosecond optical comb generator"- and laser diode-frequencies.