Andreas Hagendorff
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Andreas Hagendorff has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
B Lüderitz
8 shared publicationsD. Pfeiffer
7 shared publicationsD Pfeiffer
6 shared publications- Daniel Jurisch
Klinik und Poliklinik für Kardiologie, Universitätsklinikum Leipzig, Leipzig, Deutschland
6 shared publications L Pizzulli
Medizinische Universitätsklinik und Poliklinik, Bonn
6 shared publicationsS Stöbe
6 shared publications
Latest Publications
- 18 August 2016
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 37 (S 01) , SL10_5
Analysis of left atrial auricle morphology and function to detect considerable risk factors regarding the prevention of stroke
Atrial Fibrillation (AF) is one of the main risk factors for cardio-embolic stroke. The aim of the present study was to define morphological and functional parameters of the left atrium (LA) and the LAA to get a better risk stratification regarding the stroke risk estimation in the low risk group according to the CHA2DS2-VASc-Score. In 331 patients (pts) transesophageal and transthoracic echocardiography was performed to characterise LA and LAA morphology and function. The following parameters were determined: left ventricular ejection fraction (LVEF), left ventricular end-diastolic pressure (E/e'), biplane LA-volume, LAA morphology (3D-TEE), LAA filling and emptying velocities in the proximal and distal LAA. In pts with SR (n = 242) mean LVEF was 61%± 10, mean LA volume 57 ml ± 25, mean E/e'-ratio 13 ± 7, proximal mean LAA flow 82 cm/s ± 30, distal mean LAA flow 64 cm/s ± 24. In pts with SR 18pts (7%) showed a reduced LAA flow < 30 cm/s. The LAA morphology could be described by the chicken wing-LAA (37%), the windsock-LAA (56%), the cauliflower-LAA (6%) and the cactus-LAA (1%). A significant statistical correlation of the LAA morphology to the development of neurological events could not be observed in the present cohort. In pts with AF (n = 89; 27% of all pts) mean LVEF was 49%± 13, mean LA volume was 82 ml ± 32, mean E/e'-ratio 16 ± 8, proximal mean LAA flow 51 cm/s ± 35, distal mean LAA flow 41 cm/s ± 33. In pts with history of neurological event a higher coincidence of reduced LVEF, increased LA volume, increased E/e', and reduced proximal and distal mean LAA flow were observed. In patients with SR and without cardiovascular risk factors, e.g. hypertension and diabetes mellitus, increased LA volumes and reduced LAA flow velocities seem to be major risk factors for the development of cerebral ischemia despite of normal LVEF. Currently, these pts are not considered as risk pts by the CHA2DS2-VASc-Score.
- 18 August 2016
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 37 (S 01) , SL10_5
Analysis of left atrial auricle morphology and function to detect considerable risk factors regarding the prevention of stroke
Atrial Fibrillation (AF) is one of the main risk factors for cardio-embolic stroke. The aim of the present study was to define morphological and functional parameters of the left atrium (LA) and the LAA to get a better risk stratification regarding the stroke risk estimation in the low risk group according to the CHA2DS2-VASc-Score. In 331 patients (pts) transesophageal and transthoracic echocardiography was performed to characterise LA and LAA morphology and function. The following parameters were determined: left ventricular ejection fraction (LVEF), left ventricular end-diastolic pressure (E/e'), biplane LA-volume, LAA morphology (3D-TEE), LAA filling and emptying velocities in the proximal and distal LAA. In pts with SR (n = 242) mean LVEF was 61%± 10, mean LA volume 57 ml ± 25, mean E/e'-ratio 13 ± 7, proximal mean LAA flow 82 cm/s ± 30, distal mean LAA flow 64 cm/s ± 24. In pts with SR 18pts (7%) showed a reduced LAA flow < 30 cm/s. The LAA morphology could be described by the chicken wing-LAA (37%), the windsock-LAA (56%), the cauliflower-LAA (6%) and the cactus-LAA (1%). A significant statistical correlation of the LAA morphology to the development of neurological events could not be observed in the present cohort. In pts with AF (n = 89; 27% of all pts) mean LVEF was 49%± 13, mean LA volume was 82 ml ± 32, mean E/e'-ratio 16 ± 8, proximal mean LAA flow 51 cm/s ± 35, distal mean LAA flow 41 cm/s ± 33. In pts with history of neurological event a higher coincidence of reduced LVEF, increased LA volume, increased E/e', and reduced proximal and distal mean LAA flow were observed. In patients with SR and without cardiovascular risk factors, e.g. hypertension and diabetes mellitus, increased LA volumes and reduced LAA flow velocities seem to be major risk factors for the development of cerebral ischemia despite of normal LVEF. Currently, these pts are not considered as risk pts by the CHA2DS2-VASc-Score.
- 18 August 2016
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 37 (S 01) , PS2_06
Detection of cardiotoxicity in patients with breast cancer treated with chemotherapy
Purpose: The aim of the present study was to detect early cardiac changes in patients receiving chemotherapy with respect to the conventional and deformation parameters of 2D echocardiography. Material and methods: Thirty patients with breast cancer receiving cardiotoxic chemotherapy (taxane: paclitaxel/docetaxel) underwent 2D echocardiography (General Electric Norway). All patients were examined before and during cardiotoxic chemotherapy at a 6-month follow-up. Systolic function (left ventricular ejection fraction and global longitudinal strain) and diastolic function (septal E/E') were analyzed with 2D echocardiography. Results: For left ventricular ejection fraction and global longitudinal strain no significant differences were detected 6 month after the start of the chemotherapy. According to our results, myocardial dysfunction induced by cardiotoxic chemotherapy can be detected by early diastolic alterations. The E/E' was significantly higher after 6 month than before the chemotherapy as a marker of the diastolic dysfunction (E/E'start 9.24 ± 3.4 vs. E/E'6 month 11.32 ± 4.8, P: 0.026, paired sample t-test). Conclusion: To detect myocardial dysfunction by global longitudinal strain and left ventricular ejection fraction pontentially requires a longer follow-up. E/E' seems to be the one of the sensitive parameters to detect early myocardial damage during chemotherapy.
- 18 August 2016
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 37 (S 01) , PS2_06
Detection of cardiotoxicity in patients with breast cancer treated with chemotherapy
Purpose: The aim of the present study was to detect early cardiac changes in patients receiving chemotherapy with respect to the conventional and deformation parameters of 2D echocardiography. Material and methods: Thirty patients with breast cancer receiving cardiotoxic chemotherapy (taxane: paclitaxel/docetaxel) underwent 2D echocardiography (General Electric Norway). All patients were examined before and during cardiotoxic chemotherapy at a 6-month follow-up. Systolic function (left ventricular ejection fraction and global longitudinal strain) and diastolic function (septal E/E') were analyzed with 2D echocardiography. Results: For left ventricular ejection fraction and global longitudinal strain no significant differences were detected 6 month after the start of the chemotherapy. According to our results, myocardial dysfunction induced by cardiotoxic chemotherapy can be detected by early diastolic alterations. The E/E' was significantly higher after 6 month than before the chemotherapy as a marker of the diastolic dysfunction (E/E'start 9.24 ± 3.4 vs. E/E'6 month 11.32 ± 4.8, P: 0.026, paired sample t-test). Conclusion: To detect myocardial dysfunction by global longitudinal strain and left ventricular ejection fraction pontentially requires a longer follow-up. E/E' seems to be the one of the sensitive parameters to detect early myocardial damage during chemotherapy.
- 18 August 2016
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 37 (S 01) , PS2_08
Analysis of coronary sinus, coronary arteries and left ventricular function during carillon device implantation
Mitral valve annuloplasty via the coronary sinus (CS) is possible by the Carillon device which can create constricting force after insertion into the CS transmitted to the mitral valve and mitral annulus. To strategise this procedure the knowledge about the size and anatomy of the CS in relation to the mitral annulus is crucial. 30 consecutive patients with sinus rhythm were investigated by TEE to test the visualisation of CS and branches of the coronary arteries in the posterior region of the mitral annulus as well as the feasibility of speckle tracking of the left ventricle. An image acquisition protocol for sufficient analysis of these features should be worked out in these patients. The ostium region of the CS, the middle part of the CS in the posterior mitral annulus as well as the distal CS between anterolateral mitral commissure and left atrial appendage can be acquired in ZOOM multidimensional data sets with highest spatial resolution. The completion of this proposed protocol was possible in 80% of the patients' cohort with sinus rhythm and in 6 of 8 Carillon patients. The complete CS visualisation succeeds in 70%, the determination of the coronaries in 50% and the TEE adjustment of the LV standardised views in 80% of patients' cohort with sinus rhythm. During the intervention the speckle tracking analysis was interfered by artefacts induced by the Carillon device. CS mitral annulus analysis is feasible and helpful prior to the intervention to strategise these procedures in patients with severe mitral valve regurgitation. Thus, the importance of distinct TEE analysis of the CS and LV function is underlined prior and during Carillon interventions.
- 18 August 2016
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 37 (S 01) , PS2_08
Analysis of coronary sinus, coronary arteries and left ventricular function during carillon device implantation
Mitral valve annuloplasty via the coronary sinus (CS) is possible by the Carillon device which can create constricting force after insertion into the CS transmitted to the mitral valve and mitral annulus. To strategise this procedure the knowledge about the size and anatomy of the CS in relation to the mitral annulus is crucial. 30 consecutive patients with sinus rhythm were investigated by TEE to test the visualisation of CS and branches of the coronary arteries in the posterior region of the mitral annulus as well as the feasibility of speckle tracking of the left ventricle. An image acquisition protocol for sufficient analysis of these features should be worked out in these patients. The ostium region of the CS, the middle part of the CS in the posterior mitral annulus as well as the distal CS between anterolateral mitral commissure and left atrial appendage can be acquired in ZOOM multidimensional data sets with highest spatial resolution. The completion of this proposed protocol was possible in 80% of the patients' cohort with sinus rhythm and in 6 of 8 Carillon patients. The complete CS visualisation succeeds in 70%, the determination of the coronaries in 50% and the TEE adjustment of the LV standardised views in 80% of patients' cohort with sinus rhythm. During the intervention the speckle tracking analysis was interfered by artefacts induced by the Carillon device. CS mitral annulus analysis is feasible and helpful prior to the intervention to strategise these procedures in patients with severe mitral valve regurgitation. Thus, the importance of distinct TEE analysis of the CS and LV function is underlined prior and during Carillon interventions.
- 18 August 2016
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 37 (S 01) , P2_12
Strain analysis in patients with Barlow's disease
The aim of the present study was to detect characteristic patterns of longitudinal strain curves in patients with Barlow's disease. Standardised transthoracic echocardiography was performed in patients with Barlow's disease (group I; n = 20) and in patients with mitral regurgitation due to Carpentier's classification type I (group II; n = 20). Strain analysis by 2D speckle tracking was performed in all patients of both cohorts to obtain regional strain curve patterns and for determination of longitudinal strain values. The strain curves were compared to each other with respect to the segment which corresponds to the affected scallop of the mitral valve. The severity of mitral regurgitation was estimated by proximal isovelocity surface area, vena contracta and left ventricular systolic function. In 18 of 20 patients (90%) with Barlow's disease the segmental strain curve of the affected scallop shows a characteristic positive peak (3.92 ± 1.79) at the beginning of the systole (Fig. 1). However, reduced strain values in these segments were not necessarily determined. The most affected scallop was the P2-scallop. Thus, the characteristic positive peak could be seen most often in the posterior segment of the left ventricle (Fig. 1). In group II a minor positive peak was only present in 2 of 20 patients (10%). In contrast to patients with Barlow's disease (-21.39 ± 4.12) global peak systolic strain was reduced in these patients (-13.48 ± 6.15). In patients with Barlow's disease the positive peak at the beginning of the systole can be defined as a characteristic echocardiographic sign. This has to be distinguished from positive peaks due to hypokinesia or dyskinesia. Artifact tracking in the far field in the region of the mitral valve annulus can also produce similar strain curves. Thus, accurate tracking of the myocardium using standardized views is the prerequisite for a correct analysis.
- 18 August 2016
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 37 (S 01) , P2_12
Strain analysis in patients with Barlow's disease
The aim of the present study was to detect characteristic patterns of longitudinal strain curves in patients with Barlow's disease. Standardised transthoracic echocardiography was performed in patients with Barlow's disease (group I; n = 20) and in patients with mitral regurgitation due to Carpentier's classification type I (group II; n = 20). Strain analysis by 2D speckle tracking was performed in all patients of both cohorts to obtain regional strain curve patterns and for determination of longitudinal strain values. The strain curves were compared to each other with respect to the segment which corresponds to the affected scallop of the mitral valve. The severity of mitral regurgitation was estimated by proximal isovelocity surface area, vena contracta and left ventricular systolic function. In 18 of 20 patients (90%) with Barlow's disease the segmental strain curve of the affected scallop shows a characteristic positive peak (3.92 ± 1.79) at the beginning of the systole (Fig. 1). However, reduced strain values in these segments were not necessarily determined. The most affected scallop was the P2-scallop. Thus, the characteristic positive peak could be seen most often in the posterior segment of the left ventricle (Fig. 1). In group II a minor positive peak was only present in 2 of 20 patients (10%). In contrast to patients with Barlow's disease (-21.39 ± 4.12) global peak systolic strain was reduced in these patients (-13.48 ± 6.15). In patients with Barlow's disease the positive peak at the beginning of the systole can be defined as a characteristic echocardiographic sign. This has to be distinguished from positive peaks due to hypokinesia or dyskinesia. Artifact tracking in the far field in the region of the mitral valve annulus can also produce similar strain curves. Thus, accurate tracking of the myocardium using standardized views is the prerequisite for a correct analysis.
- 18 August 2016
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 37 (S 01) , P2_15
Analysis of echocardiographic parameters for the evaluation of Aortic Regurgitation
In the present study different approaches for the evaluation of aortic regurgitation (AR) in patients with chronic AR and in patient after TAVI were analysed. 55 patients with chronic AR and 15 patients with AR after TAVI were analysed by the conventional approach, semi-quantitative parameters and global left ventricular (LV) peak systolic strain (PSS). The conventional approach was performed by the assessment of the regurgitant fraction (RF), the regurgitant volume (RV), the effective and total stroke volume (SV). In TAVI patients AR was additionally analysed by the proportion of the valvular defect to the aortic valve ring. Total SV determinations by Doppler echocardiography and biplane planimetry showed good correlations. The assessment of the effective SV using the pulmonary valve (PV) diameter and the VTIPV or the mitral valve (MV) diameter and the VTIMV showed less good correlations. Higher or preserved global LV PSS values were observed in chronic AR patients. However, in extremely dilated left ventricles global PSS values seemed to be reduced. The Pressure-Half-Time (PHT) could be determined in 80%, the proximal isovelocity surface area (PISA) in 21% and the vena contracta (VC) in 56% of patients with chronic AR. The PHT could be determined in 40%, the PISA in 0% and the VC in 40% of patients with AR after TAVI. The conventional analysis of AR in patients with chronic AR and in patients with AR after TAVI is feasible and suitable. Semi-quantitative parameters were less suitable and will often lead to overestimation in patients with chronic AR and to underestimation of AR in patients after TAVI. Global LV PSS can be used as a descriptive parameter for the assessment of LV eccentric hypertrophy but cannot be used to characterise various stages of chronic AR. AR in patients after TAVI can be well analysed by the conventional approach.
- 18 August 2016
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 37 (S 01) , P2_15
Analysis of echocardiographic parameters for the evaluation of Aortic Regurgitation
In the present study different approaches for the evaluation of aortic regurgitation (AR) in patients with chronic AR and in patient after TAVI were analysed. 55 patients with chronic AR and 15 patients with AR after TAVI were analysed by the conventional approach, semi-quantitative parameters and global left ventricular (LV) peak systolic strain (PSS). The conventional approach was performed by the assessment of the regurgitant fraction (RF), the regurgitant volume (RV), the effective and total stroke volume (SV). In TAVI patients AR was additionally analysed by the proportion of the valvular defect to the aortic valve ring. Total SV determinations by Doppler echocardiography and biplane planimetry showed good correlations. The assessment of the effective SV using the pulmonary valve (PV) diameter and the VTIPV or the mitral valve (MV) diameter and the VTIMV showed less good correlations. Higher or preserved global LV PSS values were observed in chronic AR patients. However, in extremely dilated left ventricles global PSS values seemed to be reduced. The Pressure-Half-Time (PHT) could be determined in 80%, the proximal isovelocity surface area (PISA) in 21% and the vena contracta (VC) in 56% of patients with chronic AR. The PHT could be determined in 40%, the PISA in 0% and the VC in 40% of patients with AR after TAVI. The conventional analysis of AR in patients with chronic AR and in patients with AR after TAVI is feasible and suitable. Semi-quantitative parameters were less suitable and will often lead to overestimation in patients with chronic AR and to underestimation of AR in patients after TAVI. Global LV PSS can be used as a descriptive parameter for the assessment of LV eccentric hypertrophy but cannot be used to characterise various stages of chronic AR. AR in patients after TAVI can be well analysed by the conventional approach.
- 18 August 2016
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 37 (S 01) , P2_16
Echocardiographic analysis of left and right ventricular function in patients after mitral valve reconstruction
The aim of the present study was to analyse left (LV) and right ventricular (RV) function in patients after mitral valve reconstruction (MVR). Transthoracic echocardiography was performed in 31 patients with severe mitral valve regurgitation (MR) before and after MVR. Furthermore, patients were divided into several subgroups: firstly, asymptomatic (n = 7) and symptomatic (n = 24), secondly, isolated MVR (n = 18) and MVR with tricuspid valve reconstruction (TVR) (n = 7) or aortic valve implantation (AVI) (n = 6) and thirdly, paroxysmal atrial fibrillation (AF) (n = 23) and chronic AF (n = 8). LV dimensions and volumes were reduced after MVR. LV ejection fraction (EF) did not change after MVR. However, LV global longitudinal peak systolic strain (PSS) was reduced after MVR. In contrast to LV global longitudinal PSS values data of the free RV wall did not show reduced RV PSS values after MVR. However, TAPSE was significantly reduced after MVR. Parameters of diastolic function did not improve and systolic pulmonary pressure (sPAP) and pulmonary vascular resistance (PVR) were reduced after MVR. LV function after MVR was mostly improved in patients with asymptomatic MR, with SR or paroxysmal AF and after isolated MVR than in symptomatic patients with MR, with chronic AF and MVR with TVR or AVI. Despite of improvement of LV function the reduction of TAPSE indicates impairment of longitudinal RV deformation. However, RV strain analysis after MVR indicates unchanged RV contractility. Thus, RV function should be analysed more accurately by 3D volume changes and radial deformation analysis. In addition, a moderate MR quantified by Vena contracta-method was observed in 6 patients after MVR (20%).
- 18 August 2016
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 37 (S 01) , P2_16
Echocardiographic analysis of left and right ventricular function in patients after mitral valve reconstruction
The aim of the present study was to analyse left (LV) and right ventricular (RV) function in patients after mitral valve reconstruction (MVR). Transthoracic echocardiography was performed in 31 patients with severe mitral valve regurgitation (MR) before and after MVR. Furthermore, patients were divided into several subgroups: firstly, asymptomatic (n = 7) and symptomatic (n = 24), secondly, isolated MVR (n = 18) and MVR with tricuspid valve reconstruction (TVR) (n = 7) or aortic valve implantation (AVI) (n = 6) and thirdly, paroxysmal atrial fibrillation (AF) (n = 23) and chronic AF (n = 8). LV dimensions and volumes were reduced after MVR. LV ejection fraction (EF) did not change after MVR. However, LV global longitudinal peak systolic strain (PSS) was reduced after MVR. In contrast to LV global longitudinal PSS values data of the free RV wall did not show reduced RV PSS values after MVR. However, TAPSE was significantly reduced after MVR. Parameters of diastolic function did not improve and systolic pulmonary pressure (sPAP) and pulmonary vascular resistance (PVR) were reduced after MVR. LV function after MVR was mostly improved in patients with asymptomatic MR, with SR or paroxysmal AF and after isolated MVR than in symptomatic patients with MR, with chronic AF and MVR with TVR or AVI. Despite of improvement of LV function the reduction of TAPSE indicates impairment of longitudinal RV deformation. However, RV strain analysis after MVR indicates unchanged RV contractility. Thus, RV function should be analysed more accurately by 3D volume changes and radial deformation analysis. In addition, a moderate MR quantified by Vena contracta-method was observed in 6 patients after MVR (20%).
- 17 December 2014
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 36 (01) , 10-34
Standardized Transthoracic Echocardiography in Patients with Primary and Secondary Mitral Valve Regurgitation
Mitral valve regurgitation is the most common valve defect after aortic valve stenosis in the industrialized world. Since it is not possible to directly determine the regurgitant fraction, it is often difficult to evaluate regurgitation at the heart valves with echocardiography.
- 17 December 2014
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 36 (01) , 10-34
Standardized Transthoracic Echocardiography in Patients with Primary and Secondary Mitral Valve Regurgitation
Mitral valve regurgitation is the most common valve defect after aortic valve stenosis in the industrialized world. Since it is not possible to directly determine the regurgitant fraction, it is often difficult to evaluate regurgitation at the heart valves with echocardiography.
- 10 December 2012
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 34 (03) , 214-237
Spezielle echokardiografische Diagnostik und besondere Problemkonstellationen bei Patienten mit degenerativer Aortenklappenstenose
Trotz exakter Durchführung einer transthorakalen echokardiografischen Untersuchung bleiben häufig die Einschätzung des Schweregrads des Vitiums und die Entscheidungsfindung – von dem Befund abhängige therapeutische Konsequenzen zu treffen – schwierig. Durch den Inhalt der vorliegenden Arbeit sollen dem Leser zusätzliche, neben der konventionellen Echokardiografie bestehende, Möglichkeiten der echokardiografischen Diagnostik bei Patienten mit degenerativer Aortenstenose vorgestellt werden. Dazu gehören nicht nur die transösophageale Echokardiografie und die Stressechokardiografie, sondern auch die moderne Applikationen des Deformationsimagings. Zusätzlich werden Problemkonstellationen und Fehlermöglichkeiten bei der echokardiografischen Diagnostik der Aortenstenose erläutert.
- 10 December 2012
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 34 (03) , 214-237
Spezielle echokardiografische Diagnostik und besondere Problemkonstellationen bei Patienten mit degenerativer Aortenklappenstenose
Trotz exakter Durchführung einer transthorakalen echokardiografischen Untersuchung bleiben häufig die Einschätzung des Schweregrads des Vitiums und die Entscheidungsfindung – von dem Befund abhängige therapeutische Konsequenzen zu treffen – schwierig. Durch den Inhalt der vorliegenden Arbeit sollen dem Leser zusätzliche, neben der konventionellen Echokardiografie bestehende, Möglichkeiten der echokardiografischen Diagnostik bei Patienten mit degenerativer Aortenstenose vorgestellt werden. Dazu gehören nicht nur die transösophageale Echokardiografie und die Stressechokardiografie, sondern auch die moderne Applikationen des Deformationsimagings. Zusätzlich werden Problemkonstellationen und Fehlermöglichkeiten bei der echokardiografischen Diagnostik der Aortenstenose erläutert.
- 25 August 2006
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 30 (01) , 64-70
Beeinflussen Befunde der transösophagealen Echokardiographie bei katheterinterventionellem PFO-Verschluss die Therapie?
Ziel: Das Ziel der vorliegenden Studie war, durch eine standardisierte Dokumentation in der transösophagealen Echokardiographie (TEE) die Morphologie eines persistierenden Foramen ovale (PFO) zu charakterisieren und durch Auswertung echokardiographischer Parameter die endgültige Position nicht selbstzentrierender Verschlusssysteme (PFO-Star) und damit den Interventionserfolg abzuschätzen. Die präinterventionell ermittelten echokardiographischen Daten über die Größe des PFO sowie die ermittelten morphologischen Parameter für das interatriale Septum wurden im Hinblick auf das postinterventionelle Ergebnis nach PFO-Verschluss analysiert. Material und Methoden: Bei 31 Patienten wurden vor, während und nach dem PFO-Verschluss durch ein PFO-Star-Device TEE-Untersuchungen einschließlich Kontrast(KM)-Echokardiographie durchgeführt. Die ermittelten Parameter aus 2D-, farbcodierter Doppler- und Kontrastmittelechokardiographie vor der Katheterintervention wurden mit dem postinterventionellen Ergebnis verglichen. Ergebnisse: Zwischen der ermittelten PFO-Kanallänge, dem Microbubble-Übertritt bei KM-Gabe sowie der Vena contracta bestehen keine Korrelationen. Lange Kanäle in Verbindung mit deutlicher Abwinkelung des interatrialen Septums zur dorsalen Aortenwurzel gehen mit einer hohen Rate von klinisch überwiegend nicht relevanten Verlagerungen der implantierten Okkluder sowie persistierenden kleinen Restshunts einher. Schlussfolgerung: Ein standardisierter echokardiographischer Untersuchungsgang bei der TEE eignet sich zur klaren Charakterisierung der Morphologie des PFO. Die 2D-Darstellung des PFO und die ins linke Atrium übertretende Microbubble-Anzahl ermöglichen keine Aussage zur Größe des PFO. Die Messung der Kanallänge, der Abstände der Septumanteile zum PFO sowie der Winkel zwischen interatrialem Septum und angrenzenden kardialen Strukturen ist wichtig, da nach echokardiographischen Auswertungen Risikokonstellationen für Verlagerungen nicht selbstzentrierender Verschlusssysteme (PFO-Star) gezeigt werden können. Purpose: The aim of the present study was to characterise the morphology of patent foramen ovale (PFO) by a standardised protocol during transoesophageal echocardiography and to estimate the final and successful position of PFO-occluding devices (PFO-Star) by evaluation of parameters determined by echocardiography. The echoacardiographic parameters of septum- and PFO-morphology determined before the intervention were analysed with regard to choosing the optimal device-system for transcatheter PFO-closure. Materials and Methods: Transoesophageal echocardiography combined with application of contrast-media was performed in 31 patients before, during and after PFO-closure by using the PFO-Star-Device. The pre-interventional morphological parameters were compared with the result after PFO-closure. Results: Quantitative contrast-bubble-shunting, PFO-channel-length and Vena contracta detected by colour flow Doppler do not show any correlation. PFO-channel-length in cases with small angles between aorta and septum seems to be associated with higher risk of clinically irrelevant device-shift as well as residual shunt. Conclusion: A standardised procedure in transoesophageal echocardiography is suitable for characterising the morphology of PFO. Neither the morphology in 2D-imaging nor the amount of shunt microbubble seen in the left atrium allows a conclusive statement about the PFO size. For obtaining an optimal closure result, it is important to identify the channel-length and the distance between the interatrial septum and the PFO together with the angles between septum and the surrounding intracardiac structures.
- 25 August 2006
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 30 (01) , 64-70
Beeinflussen Befunde der transösophagealen Echokardiographie bei katheterinterventionellem PFO-Verschluss die Therapie?
Ziel: Das Ziel der vorliegenden Studie war, durch eine standardisierte Dokumentation in der transösophagealen Echokardiographie (TEE) die Morphologie eines persistierenden Foramen ovale (PFO) zu charakterisieren und durch Auswertung echokardiographischer Parameter die endgültige Position nicht selbstzentrierender Verschlusssysteme (PFO-Star) und damit den Interventionserfolg abzuschätzen. Die präinterventionell ermittelten echokardiographischen Daten über die Größe des PFO sowie die ermittelten morphologischen Parameter für das interatriale Septum wurden im Hinblick auf das postinterventionelle Ergebnis nach PFO-Verschluss analysiert. Material und Methoden: Bei 31 Patienten wurden vor, während und nach dem PFO-Verschluss durch ein PFO-Star-Device TEE-Untersuchungen einschließlich Kontrast(KM)-Echokardiographie durchgeführt. Die ermittelten Parameter aus 2D-, farbcodierter Doppler- und Kontrastmittelechokardiographie vor der Katheterintervention wurden mit dem postinterventionellen Ergebnis verglichen. Ergebnisse: Zwischen der ermittelten PFO-Kanallänge, dem Microbubble-Übertritt bei KM-Gabe sowie der Vena contracta bestehen keine Korrelationen. Lange Kanäle in Verbindung mit deutlicher Abwinkelung des interatrialen Septums zur dorsalen Aortenwurzel gehen mit einer hohen Rate von klinisch überwiegend nicht relevanten Verlagerungen der implantierten Okkluder sowie persistierenden kleinen Restshunts einher. Schlussfolgerung: Ein standardisierter echokardiographischer Untersuchungsgang bei der TEE eignet sich zur klaren Charakterisierung der Morphologie des PFO. Die 2D-Darstellung des PFO und die ins linke Atrium übertretende Microbubble-Anzahl ermöglichen keine Aussage zur Größe des PFO. Die Messung der Kanallänge, der Abstände der Septumanteile zum PFO sowie der Winkel zwischen interatrialem Septum und angrenzenden kardialen Strukturen ist wichtig, da nach echokardiographischen Auswertungen Risikokonstellationen für Verlagerungen nicht selbstzentrierender Verschlusssysteme (PFO-Star) gezeigt werden können. Purpose: The aim of the present study was to characterise the morphology of patent foramen ovale (PFO) by a standardised protocol during transoesophageal echocardiography and to estimate the final and successful position of PFO-occluding devices (PFO-Star) by evaluation of parameters determined by echocardiography. The echoacardiographic parameters of septum- and PFO-morphology determined before the intervention were analysed with regard to choosing the optimal device-system for transcatheter PFO-closure. Materials and Methods: Transoesophageal echocardiography combined with application of contrast-media was performed in 31 patients before, during and after PFO-closure by using the PFO-Star-Device. The pre-interventional morphological parameters were compared with the result after PFO-closure. Results: Quantitative contrast-bubble-shunting, PFO-channel-length and Vena contracta detected by colour flow Doppler do not show any correlation. PFO-channel-length in cases with small angles between aorta and septum seems to be associated with higher risk of clinically irrelevant device-shift as well as residual shunt. Conclusion: A standardised procedure in transoesophageal echocardiography is suitable for characterising the morphology of PFO. Neither the morphology in 2D-imaging nor the amount of shunt microbubble seen in the left atrium allows a conclusive statement about the PFO size. For obtaining an optimal closure result, it is important to identify the channel-length and the distance between the interatrial septum and the PFO together with the angles between septum and the surrounding intracardiac structures.
- Open Access
- 1 December 2003
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 4 (suppl_1) , S3
117 Tissue velocity imaging and myocardial contrast echocardiography with power Doppler harmonic imaging during adenosine stress
A. Hagendorff, M. Pearson, A. Werner, N. Al-Saadi, D. Pfeiffer, H. Bechjer; 117 Tissue velocity imaging and myocardial contrast echocardiography with power Dop
- 1 December 2003
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 4 (suppl_1) , S3
Open Access117 Tissue velocity imaging and myocardial contrast echocardiography with power Doppler harmonic imaging during adenosine stress
A. Hagendorff, M. Pearson, A. Werner, N. Al-Saadi, D. Pfeiffer, H. Bechjer; 117 Tissue velocity imaging and myocardial contrast echocardiography with power Dop