Graeme Young
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Graeme Young has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
C. Hunt
2 shared publicationsS. Coleman
2 shared publicationsSarah Coleman
Visioncare Research Ltd, Farnham, Surrey, and 2 Johnson & Johnson Vision Care, Bracknell, Berkshire, UK
2 shared publicationsY. Lewis
2 shared publicationsChris Hunt
1 shared publicationJane Veys
Visioncare Research Ltd, Farnham, Surrey, and 2 Johnson & Johnson Vision Care, Bracknell, Berkshire, UK
1 shared publication
Latest Publications
- 1 June 2004
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 27 (2) , 83-85
Why one million contact lens wearers dropped out
- 1 June 2004
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 27 (2) , 83-85
Why one million contact lens wearers dropped out
- 1 June 2004
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 27 (2) , 83-85
Why one million contact lens wearers dropped out*1
- 1 June 2004
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 27 (2) , 83-85
Why one million contact lens wearers dropped out*1
- 1 January 2003
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 29 (1) , S171-S173
Toric Contact Lens Designs in Hyper-Oxygen Materials
A high proportion of eyes show significant astigmatism, and therefore toric silicone hydrogel lenses are required to satisfy the demand for continuous wear. Two concerns arise from the inevitable, increased thickness associated with toric designs: reduced oxygen transmissibility and increased rigidity leading to possible mechanical trauma. An improved understanding of the mechanisms governing toric soft-lens orientation and fit will enable the development of thinner designs. Gravity has little effect on prism-ballasted soft lenses within approximately 30 degrees of the base-down position. Some correlations have been noted between lid position and orientation. Measurements from video recordings of toric soft lenses during reorientation indicate that lid-induced rotation takes place during rather than between blinks. However, high-speed video recordings indicate that the influence of the lower lid can override that of the upper lid depending on its position, tightness, and amount of lateral movement. This knowledge gives some pointers toward optimizing toric soft lens designs in hyper-oxygen materials.
- 1 January 2003
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 29 (1) , S171-S173
Toric Contact Lens Designs in Hyper-Oxygen Materials
A high proportion of eyes show significant astigmatism, and therefore toric silicone hydrogel lenses are required to satisfy the demand for continuous wear. Two concerns arise from the inevitable, increased thickness associated with toric designs: reduced oxygen transmissibility and increased rigidity leading to possible mechanical trauma. An improved understanding of the mechanisms governing toric soft-lens orientation and fit will enable the development of thinner designs. Gravity has little effect on prism-ballasted soft lenses within approximately 30 degrees of the base-down position. Some correlations have been noted between lid position and orientation. Measurements from video recordings of toric soft lenses during reorientation indicate that lid-induced rotation takes place during rather than between blinks. However, high-speed video recordings indicate that the influence of the lower lid can override that of the upper lid depending on its position, tightness, and amount of lateral movement. This knowledge gives some pointers toward optimizing toric soft lens designs in hyper-oxygen materials.
- 24 November 2002
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 22 (6) , 516-527
A multi‐centre study of lapsed contact lens wearers
Purpose: Discontinuation from contact lens wear has been identified as a contributing factor in the lack of growth of contact lens use in Europe. The purpose of this study was to determine the proportion of lapsed contact lens wearers that can be refitted successfully with contact lenses and to evaluate the reasons for discontinuation from contact lens wear. Methods: This was a multi‐site clinical study involving 15 UK investigators and 236 lapsed contact lens wearers who had previously tried contact lenses and discontinued. The reasons for discontinuation were assessed by subjects, who were then refitted with contact lenses. Investigators subsequently evaluated factors associated with their initial discontinuation. Short‐term success was defined as the successful completion of 1 month of contact lens wear with absence of complications that would prevent further wear. Subjects were interviewed by telephone 6 months after being refitted to determine whether they were still wearing contact lenses. Those who were not wearing lenses were questioned about the reasons for discontinuation and their likelihood of resuming lens wear. Results: A majority of subjects (51%) cited discomfort as the principal reason for having previously given up contact lens wear. Problems with vision were the second most common reason (13%), either with reading (6%) or general vision (7%). The most common type of discomfort was dryness (40%). In almost all cases (97%), the investigator's assessment of the reasons for discontinuation agreed with the subject's own assessment but investigators also cited product‐related and practitioner‐related factors as contributing to previous failure. The short‐term success rate for refitting lapsed wearers was found to be 77% (CI: 70–82%). The highest short‐term success rates were for 2‐weekly/monthly soft spherical lenses (91%) and daily disposable lenses (89%). Lower success rates were found for soft toric (69%) and soft bifocal (53%) lenses. At the 6‐month stage, 73% of those who continued in lenses after the 1‐month visit were still wearing contact lenses and a further 18% indicated that they were either ‘very likely’ or ‘likely’ to resume lens wear. Conclusions: A high proportion of lapsed contact lens wearers can be successfully refitted with contact lenses. The prime reason for previous discontinuation from contact lenses is discomfort and, in particular, dryness‐related discomfort. In many cases, previous contact lens failure is product or practitioner‐related rather than because of patient‐specific problems. Once refitted with contact lenses, lapsed wearers cite vision problems rather than discomfort as the most common reason for discontinuing. This finding suggests that recent advances in contact lens material, design, replacement frequencies and care systems have improved the prospects for avoiding lens‐related discomfort and for continuing contact lens wear.
- 24 November 2002
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 22 (6) , 516-527
A multi‐centre study of lapsed contact lens wearers
Purpose: Discontinuation from contact lens wear has been identified as a contributing factor in the lack of growth of contact lens use in Europe. The purpose of this study was to determine the proportion of lapsed contact lens wearers that can be refitted successfully with contact lenses and to evaluate the reasons for discontinuation from contact lens wear. Methods: This was a multi‐site clinical study involving 15 UK investigators and 236 lapsed contact lens wearers who had previously tried contact lenses and discontinued. The reasons for discontinuation were assessed by subjects, who were then refitted with contact lenses. Investigators subsequently evaluated factors associated with their initial discontinuation. Short‐term success was defined as the successful completion of 1 month of contact lens wear with absence of complications that would prevent further wear. Subjects were interviewed by telephone 6 months after being refitted to determine whether they were still wearing contact lenses. Those who were not wearing lenses were questioned about the reasons for discontinuation and their likelihood of resuming lens wear. Results: A majority of subjects (51%) cited discomfort as the principal reason for having previously given up contact lens wear. Problems with vision were the second most common reason (13%), either with reading (6%) or general vision (7%). The most common type of discomfort was dryness (40%). In almost all cases (97%), the investigator's assessment of the reasons for discontinuation agreed with the subject's own assessment but investigators also cited product‐related and practitioner‐related factors as contributing to previous failure. The short‐term success rate for refitting lapsed wearers was found to be 77% (CI: 70–82%). The highest short‐term success rates were for 2‐weekly/monthly soft spherical lenses (91%) and daily disposable lenses (89%). Lower success rates were found for soft toric (69%) and soft bifocal (53%) lenses. At the 6‐month stage, 73% of those who continued in lenses after the 1‐month visit were still wearing contact lenses and a further 18% indicated that they were either ‘very likely’ or ‘likely’ to resume lens wear. Conclusions: A high proportion of lapsed contact lens wearers can be successfully refitted with contact lenses. The prime reason for previous discontinuation from contact lenses is discomfort and, in particular, dryness‐related discomfort. In many cases, previous contact lens failure is product or practitioner‐related rather than because of patient‐specific problems. Once refitted with contact lenses, lapsed wearers cite vision problems rather than discomfort as the most common reason for discontinuing. This finding suggests that recent advances in contact lens material, design, replacement frequencies and care systems have improved the prospects for avoiding lens‐related discomfort and for continuing contact lens wear.
- 1 May 2002
- Published by Wiley in Optometry and Vision Science
- Vol. 79 (5) , 321-328
Clinical Evaluation of Toric Soft Lens Reproducibility
The manufacturing variability of frequent replacement toric soft lenses is such that some resulting variation in clinical performance can be expected. The purpose of this study was to evaluate the effect of manufacturing variability on the clinical performance of three frequent replacement toric soft contact lenses. This was a three-part study in which 12 to 14 subjects were enrolled for each part. In each part, subjects were preadapted to the lens type 1 month prior to the assessment visits. Subjects wore a total of 12 test lenses in one eye and, in each case, the clinical performance was compared with a control lens of the same type worn in the other eye that was removed between assessments but not replaced. The study lenses were Acuvue Toric (Vistakon), Focus Toric (Ciba Vision) and FreshLook Toric (Wesley Jessen). Two lens types (Focus Toric and FreshLook Toric) showed significantly greater variability with the test lenses compared with the nonreplaced control lenses with several variables: lens fit, visual acuity, and subjective vision quality. One lens (Focus Toric) also showed greater variability of orientation position, and another (Acuvue Toric) showed greater variability in subjective vision quality. The study demonstrated variability in aspects of clinical performance, which appear to be linked to variability of manufacturing output. With toric soft lenses used on a frequent replacement basis, better reproducibility is needed if consistent clinical performance is to be maintained.
- 1 May 2002
- Published by Wiley in Optometry and Vision Science
- Vol. 79 (5) , 321-328
Clinical Evaluation of Toric Soft Lens Reproducibility
The manufacturing variability of frequent replacement toric soft lenses is such that some resulting variation in clinical performance can be expected. The purpose of this study was to evaluate the effect of manufacturing variability on the clinical performance of three frequent replacement toric soft contact lenses. This was a three-part study in which 12 to 14 subjects were enrolled for each part. In each part, subjects were preadapted to the lens type 1 month prior to the assessment visits. Subjects wore a total of 12 test lenses in one eye and, in each case, the clinical performance was compared with a control lens of the same type worn in the other eye that was removed between assessments but not replaced. The study lenses were Acuvue Toric (Vistakon), Focus Toric (Ciba Vision) and FreshLook Toric (Wesley Jessen). Two lens types (Focus Toric and FreshLook Toric) showed significantly greater variability with the test lenses compared with the nonreplaced control lenses with several variables: lens fit, visual acuity, and subjective vision quality. One lens (Focus Toric) also showed greater variability of orientation position, and another (Acuvue Toric) showed greater variability in subjective vision quality. The study demonstrated variability in aspects of clinical performance, which appear to be linked to variability of manufacturing output. With toric soft lenses used on a frequent replacement basis, better reproducibility is needed if consistent clinical performance is to be maintained.
- 1 January 2002
- Published by Wiley in Optometry and Vision Science
- Vol. 79 (1) , 11-19
Clinical Evaluation of Factors Influencing Toric Soft Contact Lens Fit
Some knowledge of the orientation position of toric soft lenses is required as part of the fitting process. Although it is known that factors such as lid anatomy, lens design, and fit are important, there is little detailed understanding of how these relate to toric lens orientation. The purpose of this study was to evaluate various patient and lens factors that might influence toric soft lens fit and to determine the predictor variables for lens orientation. This was a clinical study in which 45 subjects were fitted with a prism-stabilized, mid-water, cast-molded, back surface toric soft lens. The lens was representative of commonly used designs for frequent replacement toric soft lenses. Patient and lens fit variables were assessed, including a range of lid topography features, which were measured using a digital photographic technique. The main patient factors associated with lens orientation and stability were degree of myopia, palpebral aperture, and several angles relating to lid anatomy. Greater upward incline of the temporal lids was associated with increasing inferior-temporal lens orientation; lower myopia and smaller palpebral aperture size were associated with more stable lens orientation. The principal lens fit characteristics affecting lens orientation were postblink movement and lens tightness. Less movement was associated with more stable lens orientation, and increased tightness was associated with slower reorientation speed. Weaker but significant correlations were also shown between a number of other patient and lens variables. A number of patient factors and lens fit characteristics influencing toric soft lens orientation were identified. The findings fall short of allowing practitioners to accurately predict toric lens orientation; however, they do provide some factors to consider when fitting toric soft lenses.
- 1 January 2002
- Published by Wiley in Optometry and Vision Science
- Vol. 79 (1) , 11-19
Clinical Evaluation of Factors Influencing Toric Soft Contact Lens Fit
Some knowledge of the orientation position of toric soft lenses is required as part of the fitting process. Although it is known that factors such as lid anatomy, lens design, and fit are important, there is little detailed understanding of how these relate to toric lens orientation. The purpose of this study was to evaluate various patient and lens factors that might influence toric soft lens fit and to determine the predictor variables for lens orientation. This was a clinical study in which 45 subjects were fitted with a prism-stabilized, mid-water, cast-molded, back surface toric soft lens. The lens was representative of commonly used designs for frequent replacement toric soft lenses. Patient and lens fit variables were assessed, including a range of lid topography features, which were measured using a digital photographic technique. The main patient factors associated with lens orientation and stability were degree of myopia, palpebral aperture, and several angles relating to lid anatomy. Greater upward incline of the temporal lids was associated with increasing inferior-temporal lens orientation; lower myopia and smaller palpebral aperture size were associated with more stable lens orientation. The principal lens fit characteristics affecting lens orientation were postblink movement and lens tightness. Less movement was associated with more stable lens orientation, and increased tightness was associated with slower reorientation speed. Weaker but significant correlations were also shown between a number of other patient and lens variables. A number of patient factors and lens fit characteristics influencing toric soft lens orientation were identified. The findings fall short of allowing practitioners to accurately predict toric lens orientation; however, they do provide some factors to consider when fitting toric soft lenses.
- 31 December 2001
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 24 (1) , 25-33
Process capability measurement of frequent replacement toric soft contact lenses
- 31 December 2001
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 24 (1) , 25-33
Process capability measurement of frequent replacement toric soft contact lenses
- 1 January 1999
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 22 (4) , 127-135
Process capability measurement of frequent replacement spherical soft contact lenses
- 1 January 1999
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 22 (4) , 127-135
Process capability measurement of frequent replacement spherical soft contact lenses