Djenane Cordeiro Pamplona
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Djenane Cordeiro Pamplona has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Batista Goncalves
Pontifical Catholic University of Rio de Janeiro
3 shared publications Adolfo A. Leirner
Center of Biomedical Technology, Heart Institute (InCor), University of São Paulo Medical School, São Paulo, Brazil
1 shared publicationCristina de Abreu Alvim
Civil Engineering Department, Pontifícia Universidade Católica do Rio de Janeiro (PUC‐Rio), Rio de Janeiro, Brazil
1 shared publicationH.I. Weber
Mechanical Engineering Department, Catholic University, PUC-Rio 22453-900, Rio de Janeiro, Brazil
1 shared publicationIdágene A. Cestari
Center of Biomedical Technology, Heart Institute (InCor), University of São Paulo Medical School, São Paulo, Brazil
1 shared publicationM. Davidovich
Civil Engineering Department, Catholic University, PUC-Rio 33452-900, Rio de Janeiro, Brazil
1 shared publication
Latest Publications
- 19 September 2006
- Published by Wiley in Communications in Numerical Methods in Engineering
- Vol. 23 (6) , 577-597
Influence of initial geometric imperfections on the stability of thick cylindrical shells under internal pressure
This paper investigates numerically and experimentally the influence of initial geometric imperfections on the critical loads of initially stretched thick hyperelastic cylindrical shells under increasing uniform internal pressure. Imperfections in shells can have a global or local character. First, two types of local imperfections are considered: (1) a local axially symmetric imperfection in the form of a ring and (2) a small rectangular imperfection. The influence of the imperfection thickness, position and size are analysed in detail. Results show that the critical load decreases as the imperfections increase in size or thickness and as they move from the boundaries to the centre of the shell. The influence of multiple local imperfections is also studied in the present paper. Finally, the influence of global imperfections is considered with the imperfections described as a variation of the shell curvature in the axial direction. The results show that thick hyperelastic shells may be sensitive to local and global imperfections. In all cases the experimental results are in good agreement with the numerical ones, corroborating the conclusions. Copyright © 2006 John Wiley & Sons, Ltd.
- 19 September 2006
- Published by Wiley in Communications in Numerical Methods in Engineering
- Vol. 23 (6) , 577-597
Influence of initial geometric imperfections on the stability of thick cylindrical shells under internal pressure
This paper investigates numerically and experimentally the influence of initial geometric imperfections on the critical loads of initially stretched thick hyperelastic cylindrical shells under increasing uniform internal pressure. Imperfections in shells can have a global or local character. First, two types of local imperfections are considered: (1) a local axially symmetric imperfection in the form of a ring and (2) a small rectangular imperfection. The influence of the imperfection thickness, position and size are analysed in detail. Results show that the critical load decreases as the imperfections increase in size or thickness and as they move from the boundaries to the centre of the shell. The influence of multiple local imperfections is also studied in the present paper. Finally, the influence of global imperfections is considered with the imperfections described as a variation of the shell curvature in the axial direction. The results show that thick hyperelastic shells may be sensitive to local and global imperfections. In all cases the experimental results are in good agreement with the numerical ones, corroborating the conclusions. Copyright © 2006 John Wiley & Sons, Ltd.
- 1 April 2004
- Published by Wiley in Artificial Organs
- Vol. 28 (4) , 353-356
Breast Reconstruction with Expanders and Implants: A Numerical Analysis
In the last few decades, breast reconstruction has evolved significantly due to improvement in surgical techniques and development of new materials. Although most authors consider that breast reconstruction using autologous tissue offers the best aesthetic results, excellent outcomes have been obtained employing silicone implants. However there is a lack of good understanding of the implications of using each type of adjustable implant on tissue dynamics and the influence on final breast shape. The aim of this research is to analyze the stresses and strains that occur in skin immediately after breast reconstruction. This simulation is performed using the finite element package ABAQUS/Explicit.
- 1 April 2004
- Published by Wiley in Artificial Organs
- Vol. 28 (4) , 353-356
Breast Reconstruction with Expanders and Implants: A Numerical Analysis
In the last few decades, breast reconstruction has evolved significantly due to improvement in surgical techniques and development of new materials. Although most authors consider that breast reconstruction using autologous tissue offers the best aesthetic results, excellent outcomes have been obtained employing silicone implants. However there is a lack of good understanding of the implications of using each type of adjustable implant on tissue dynamics and the influence on final breast shape. The aim of this research is to analyze the stresses and strains that occur in skin immediately after breast reconstruction. This simulation is performed using the finite element package ABAQUS/Explicit.
- 1 November 2001
- Published by Wiley in Artificial Organs
- Vol. 25 (11) , 912-921
Mechanical Behavior and Stability of the Internal Membrane of the InCor Ventricular Assist Device
This paper describes and analyzes the mechanical behavior of the internal membrane of the InCor VAD (Heart Institute [InCor], University of São Paulo, Brazil), applying the knowledge and tools of structural engineering analysis. This membrane plays an important role in the operation of the ventricular assist device (VAD) because it separates the blood chamber from the pneumatic one, transmitting the pneumatic load to the blood, thus making the desired blood flow possible. The loading repeats itself every time the VAD beats. Therefore the performance, reliability, and durability of the membrane are critical for the performance of the VAD. The mathematical model is based on the large deflection theory of thin shells and on the finite element method. The snap‐through instability phenomenon, which is responsible for transmission of the pneumatic load to the blood, was observed in the membrane both when modeled mathematically and experimentally. Principal stresses and strain distributions were obtained with this model at certain load levels along the pre‐ and postbuckling paths.
- 1 November 2001
- Published by Wiley in Artificial Organs
- Vol. 25 (11) , 912-921
Mechanical Behavior and Stability of the Internal Membrane of the InCor Ventricular Assist Device
This paper describes and analyzes the mechanical behavior of the internal membrane of the InCor VAD (Heart Institute [InCor], University of São Paulo, Brazil), applying the knowledge and tools of structural engineering analysis. This membrane plays an important role in the operation of the ventricular assist device (VAD) because it separates the blood chamber from the pneumatic one, transmitting the pneumatic load to the blood, thus making the desired blood flow possible. The loading repeats itself every time the VAD beats. Therefore the performance, reliability, and durability of the membrane are critical for the performance of the VAD. The mathematical model is based on the large deflection theory of thin shells and on the finite element method. The snap‐through instability phenomenon, which is responsible for transmission of the pneumatic load to the blood, was observed in the membrane both when modeled mathematically and experimentally. Principal stresses and strain distributions were obtained with this model at certain load levels along the pre‐ and postbuckling paths.
- 10 January 2001
- Published by Elsevier in International Journal of Solids and Structures
- Vol. 38 (10-13) , 2033-2047
Finite axisymmetric deformations of an initially stressed fluid-filled cylindrical membrane
- 10 January 2001
- Published by Elsevier in International Journal of Solids and Structures
- Vol. 38 (10-13) , 2033-2047
Finite axisymmetric deformations of an initially stressed fluid-filled cylindrical membrane