ATAdalberto Torres

Adalberto Torres

*This is an algorithmically generated author record based on publicly available information.

Adalberto Torres has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Dale M. Geiss

    From the Departments of Pediatrics (FSY, AT, RF) and Surgery (RF, DMG), University of Illinois College of Medicine at Peoria, and the Children’s Hospital of Illinois at OSF St. Francis Medical Center, Peoria, IL

    2 shared publications
  • Girish G. Deshpande

    Children’s Hospital of Illinois

    2 shared publications
  • David L. Buchanan

    University of Illinois College of Medicine, Peoria, Illinois

    1 shared publication
  • Farshad Sedaghat-Yazdi

    Department of Pediatrics, University of Illinois College of Medicine, Children's Hospital of Illinois at OSF St. Francis Medical Center, Peoria, IL, USA

    1 shared publication
  • G. Kris Bysani

    University of Illinois College of Medicine at Peoria

    1 shared publication
  • Gary W. Raff

    University of California

    1 shared publication

Latest Publications

  • Resident and Nurse Education in Pediatric Intensive Care Unit

    by Girish G. Deshpande, Gwen J. Lombard, Adalberto Torres

  • Open Access

    Computerized Pharmaceutical Algorithm Reduces Medication Administration Errors During Simulated Resuscitations

    by Girish G. Deshpande, Adalberto Torres, David L. Buchanan, Susan C. Shane Gray, Suzanne C. Brown, Theresa Hoadley, Patricia L. Ruppel, Joseph D. Tobias

    OBJECTIVE: Medication errors involving intravenous medications continue to be a significant problem, particularly in the pediatric population due to the high rate of point-of-care and weight-adjusted dosing. The pharmaceutical algorithm computerized calculator (pac2) assists in converting physician medication orders to correct volumes and rates of administration for intravenous medications. This study was designed to assess the efficacy of the pac2 in simulated clinical scenarios of point-of-care dosing. Methods: The study design was a within-subject controlled study in which 33 nurses from pediatrics, pediatric critical care, or critical care (mean nursing experience of 10.9 years) carried out various point-of-care medication-dosing scenarios with and without the aid of the pac2. RESULTS: Use of the pac2 resulted in a significantly higher percentage (mean [95% CI]) of medication volumes calculated and drawn accurately (91% [87–95%] versus 61% [52–70%], p<0.0001), a higher percentage of correct recall of essential medication information (97% [95–99%] versus 45% [36–53%], p<0.0001), and better recognition of unsafe doses (93% [87–99%] versus 19% [12–27%], p<0.0001) as compared to usual practice. The pac2 also significantly reduced average medication calculation times (1.5 minutes [1.3–1.7 minutes] versus 1.9 minutes [1.6–2.2 minutes], p=0.0028) as compared to usual practice. CONCLUSIONS: The pac2 significantly improved the performance of drug calculations by pediatric and critical care nurses during simulated clinical scenarios designed to mimic point-of-care dosing. These results suggest that the pac2 addresses an area of safety vulnerability for point-of-care dosing practices and could be a useful addition to a hospital's overall program to minimize medication errors.


  • Pulse oximeter accuracy and precision affected by sensor location in cyanotic children

    by Farshad Sedaghat-Yazdi, Adalberto Jr Md Torres, Randall Fortuna, Dale M. Geiss

    Objective: Children’s digits are often too small for proper attachment of oximeter sensors, necessitating sensor placement on the sole of the foot or palm of the hand. No study has determined what effect these sensor locations have on the accuracy and precision of this technology. The objective of this study was to assess the effect of sensor location on pulse oximeter accuracy (i.e., bias) and precision in critically ill children. Design: Prospective, observational study with consecutive sampling. Setting: Tertiary care, pediatric intensive care unit. Patients: Fifty critically ill children, newborn to 2 yrs of age, with an indwelling arterial catheter. Forty-seven of 50 (94%) patients were postcardiac surgery. Interventions: None. Measurements and Main Results: Co-oximeter-measured arterial oxygen saturation (Sao2) was compared with simultaneously obtained pulse oximetry saturations (Spo2). A total of 98 measurements were obtained, 48 measurements in the upper extremities (finger and palm) and 50 measurements in the lower extremities (toe and sole). The median Sao2 was 92% (66% to 100%). There was a significant difference in bias (i.e., average Spo2 − Sao2) and precision (±1 sd) when the sole and toe were compared (sole, 2.9 ± 3.9 vs. toe, 1.6 ± 2.2, p = .02) but no significant difference in bias and precision between the palm and the finger (palm, 1.4 ± 3.2 vs. finger, 1.2 ± 2.3, p = .99). There was a significant difference in bias ± precision when the Sao2 was 2 was ≥90% in the sole (6.0 ± 5.7 vs. 1.8 ± 2.1, p = .002) and palm (4.5 ± 4.5 vs. 0.7 ± 2.4, p = .006) but no significant difference in the finger (1.8 ± 3.8 vs. 1.1 ± 1.8, p = .95) or toe (1.9 ± 2.9 vs. 1.6 ± 1.9, p = .65). Conclusions: The Philips M1020A pulse oximeter and Nellcor MAX-N sensors were less accurate and precise when used on the sole of the foot or palm of the hand of a child with an Sao2 <90%.


  • Pulse Oximetry in Children with Congenital Heart Disease: Effects of Cardiopulmonary Bypass and Cyanosis

    by Adalberto Torres, Kelly M. Skender, Julie D. Wohrley, Jean C. Aldag, Gary W. Raff, G. Kris Bysani, Dale M. Geiss

    The objective of this prospective, observational study with consecutive sampling was to assess the reliability, bias, and precision of Nellcor N-395 (N) and Masimo SET Radical (M) pulse oximeters in children with cyanotic congenital heart disease and children with congenital heart disease recovering from cardiopulmonary bypass-assisted surgery admitted to a cardiovascular operating suite and pediatric intensive care unit at a tertiary care community hospital. Forty-six children with congenital heart disease were studied in 1 of 2 groups: (1) those recovering from cardiopulmonary bypass with a serum lactic acid > 2 mmol/L, and (2) those with co-oximetry measured saturations (SaO 2) < 90% and no evidence of shock. Measurements of SaO 2 of whole blood were compared to simultaneous pulse oximetry saturations (SpO 2). Data were analyzed to detect significant differences in SpO 2 readout failures between oximeters and average SpO 2 - SaO 2 ± 1 SD for each oximeter. A total of 122 SaO 2 measurements were recorded; the median SaO 2 was 83% (57 - 100%). SpO 2 failures after cardiopulmonary bypass were 41% (25/61) for N versus 10% (6/61) for M ( P < .001). There was a significant difference in bias (ie, average SpO 2 - SaO 2) and precision (± 1 SD) between oximeters (N, 1.1 ± 3.3 vs M, -0.2 ± 4.1; P < .001) in the postcardiopulmonary bypass group but no significant difference in bias and precision between oximeters in the cyanotic congenital heart disease group (N, 2.9 ± 4.6 vs M, 2.8 ± 6.2; P = .848). The Nellcor N-395 pulse oximeter failed more often immediately after cardiopulmonary bypass than did the Masimo SET Radical pulse oximeter. SpO2 measured with both oximeters overestimated SaO2 in the presence of persistent hypoxemia.


  • An in vitro validation of a commercially available metabolic cart using pediatric ventilator volumes

    by Patricia A. Webster, Sandra E. King, Adalberto Torres

    Our objective was to determine the validity of the SensorMedics 2900 Metabolic Measurement Cart® (SensorMedics Corp., Yorba Linda, CA) for use at pediatric ventilator volumes by designing an in vitro validation study. The study was performed using a previously described nitrogen dilution, carbon dioxide infusion technique in which known amounts of nitrogen (N2) and carbon dioxide (CO2) are infused while a test lung is ventilated. Metabolic measurements were made at tidal volumes (Vt) varying from 50–500 mL at a peak end‐expiratory pressure (PEEP) of 0 and 12 cm H2O and at inspiratory oxygen fractions (Fs) ranging from 0.21–0.60. Each study was repeated six times to assess reproducibility of measurements. At a PEEP of 0 cm H2O, the measurement of oxygen consumption (V′), carbon dioxide production (V′), and minute ventilation (V′E) were all within ±10% of predicted values at all Fs except when Vtt was 50 mL. When PEEP was increased to 12 cm H2O, error in measurement of V′ increased and became unacceptably large as F was increased. Each study consisted of six trials, and results showed acceptable reproducibility as demonstrated by narrow 95% confidence intervals. For Vts of 100–500 mL, the metabolic monitor provided accurate and reproducible results under in vitro testing conditions when PEEP was low. Accurate results could not be obtained with a Vt of 50 mL or at elevated PEEP. Pediatr Pulmonol. 1998; 26:405–411.