Pradeep Patanwar
Department of M echanical Engineering Institute of Technology Banaras Hindu University 221005 Varanasi India
2 shared publications- A. A. F. Al-Hamadani
Department of Mechanical Engineering I.T. B.H.U Varanasi UP India
1 shared publication - Ajeet Kumar Rai
Department of Mech Engg, SSET SHIATS DU Allahabad
1 shared publication Ali Abdulruda Farhan Al-Hamadani
Department of Mechanical Engineer- ing Wasit University, Iraq
1 shared publicationAmit Jhalani
Dr. K. N. Modi University
1 shared publicationArjun Sharma
1 shared publication
Latest Publications
- Open Access
- 31 May 2023
- Published by Universitas Tarumanagara in International Journal of Application on Sciences, Technology and Engineering
- Vol. 1 (2) , 373-378
Comparison Emission and Fuel Consumption of Engine of 6000 Watts Electric Generator Fuelled with Biogas and Gasoline
The electric generator with a capacity 6000 watts was prepared in this research to be able to be fuelled with flexible fuel. The engine in this generator was 4 strokes engine, single cylinder of 4 stroke spark ignition engine with cylinder volume of 420 cc that can be operated fully with biogas and if biogas is not available, the engine can also be run by using gasoline with an easy switch mechanism. The method developed in this research was different from the idea of dual-fuel which was the fuel was mixed. Two types of Biogas are prepared in this research, type 1 biogas was purified from H2S and H2O, and type 2 of biogas was purified from CO2, H2S, and H2O. The gasoline type that was used in this work was the pertalite with a research octane number (RON) was 90. The engine was run with no load (idle position) and with a load 250 watts and the effect on emission and fuel consumption were recorded and analyzed. The result indicates that the average fuel consumption of using biogas type 1 is about 44.24 L/Minute in idle position and increases to become 45.35 L/minute with load 250 watts. For biogas type 2 the fuel consumption is found about lower, that is 43.76 L/Minute in idling position and increase to reach 45.04 L/minute for with load 250 watts.It is noted here that by using gasoline the fuel consumption is 0,023 L/ Minutes in idle position and a little bit increase to become 0.024 L/minute for 250-watt load. The CO emission is found at 3.91 % vol. for gasoline engine in idle position and reduce a little bit to become 3.5 % vol. with load 250 watts. The emission is found excellent if biogas is used as a fuel comparing gasoline. For biogas type 1, the CO emission is found 0.06 % vol. in idle position and just a bit increase to become 0.07 % vol. if loaded at 250 watts. The best performance is found for biogas type 2 that the CO emission is found 0.04% vol. and still in this value at loading 250 watts.
- 31 May 2023
- Published by Universitas Tarumanagara in International Journal of Application on Sciences, Technology and Engineering
- Vol. 1 (2) , 373-378
Open AccessComparison Emission and Fuel Consumption of Engine of 6000 Watts Electric Generator Fuelled with Biogas and Gasoline
The electric generator with a capacity 6000 watts was prepared in this research to be able to be fuelled with flexible fuel. The engine in this generator was 4 strokes engine, single cylinder of 4 stroke spark ignition engine with cylinder volume of 420 cc that can be operated fully with biogas and if biogas is not available, the engine can also be run by using gasoline with an easy switch mechanism. The method developed in this research was different from the idea of dual-fuel which was the fuel was mixed. Two types of Biogas are prepared in this research, type 1 biogas was purified from H2S and H2O, and type 2 of biogas was purified from CO2, H2S, and H2O. The gasoline type that was used in this work was the pertalite with a research octane number (RON) was 90. The engine was run with no load (idle position) and with a load 250 watts and the effect on emission and fuel consumption were recorded and analyzed. The result indicates that the average fuel consumption of using biogas type 1 is about 44.24 L/Minute in idle position and increases to become 45.35 L/minute with load 250 watts. For biogas type 2 the fuel consumption is found about lower, that is 43.76 L/Minute in idling position and increase to reach 45.04 L/minute for with load 250 watts.It is noted here that by using gasoline the fuel consumption is 0,023 L/ Minutes in idle position and a little bit increase to become 0.024 L/minute for 250-watt load. The CO emission is found at 3.91 % vol. for gasoline engine in idle position and reduce a little bit to become 3.5 % vol. with load 250 watts. The emission is found excellent if biogas is used as a fuel comparing gasoline. For biogas type 1, the CO emission is found 0.06 % vol. in idle position and just a bit increase to become 0.07 % vol. if loaded at 250 watts. The best performance is found for biogas type 2 that the CO emission is found 0.04% vol. and still in this value at loading 250 watts.
- 30 August 2021
- Published by Wiley in International Journal of Energy Research
- Vol. 46 (2) , 937-951
Experimental and numerical analysis of solar still using Pyrex glass quantum dot in tropical climate
- 30 August 2021
- Published by Wiley in International Journal of Energy Research
- Vol. 46 (2) , 937-951
Experimental and numerical analysis of solar still using Pyrex glass quantum dot in tropical climate
- 6 April 2016
- Published by Taylor & Francis in Biofuels
- Vol. 7 (5) , 471-477
Experimental analysis of combustion characteristics on a variable compression ratio engine fuelled with biodiesel (castor oil) and diesel blends
Castor biodiesel was used to investigate the combustion characteristics of a variable compression ratio engine with blending ratio of B00 to B50 and compression ratio from 15 to 18. After extensive experimental work and observation, the effect on various parameter like mean gas temperature, cylinder pressure variation, net heat release, and mass fraction burned are compared with compression ratio and blending ratio. Observations have been drawn on the effects of the above parameters with various inputs. Mean gas temperature increases with compression ratio for all blending ratios and gives maximum value for B00. Cylinder pressure increases with compression ratio and maximum value is obtained at compression ratio 18 for B50. Net heat release decreases with compression ratio and maximum value is obtained for B00 at compression ratio 15. Mass fraction burned is better for B20 and poor for B50 for compression ratio 15 and 18.
- 6 April 2016
- Published by Taylor & Francis in Biofuels
- Vol. 7 (5) , 471-477
Experimental analysis of combustion characteristics on a variable compression ratio engine fuelled with biodiesel (castor oil) and diesel blends
Castor biodiesel was used to investigate the combustion characteristics of a variable compression ratio engine with blending ratio of B00 to B50 and compression ratio from 15 to 18. After extensive experimental work and observation, the effect on various parameter like mean gas temperature, cylinder pressure variation, net heat release, and mass fraction burned are compared with compression ratio and blending ratio. Observations have been drawn on the effects of the above parameters with various inputs. Mean gas temperature increases with compression ratio for all blending ratios and gives maximum value for B00. Cylinder pressure increases with compression ratio and maximum value is obtained at compression ratio 18 for B50. Net heat release decreases with compression ratio and maximum value is obtained for B00 at compression ratio 15. Mass fraction burned is better for B20 and poor for B50 for compression ratio 15 and 18.
- 8 March 2013
- Published by River Publishers in Distributed Generation & Alternative Energy Journal
- p. 6-28
Performance of Single Slope Solar Still with Solar Protected Condenser
To improve the performance of the single slope solar still, an ab-sorber plate with block shaped fins and a Phase Change Material cham-ber (PCM) with slender shaped fins are used. Experimental investiga-tions have been carried out on two solar stills, namely conventional solarstill and a modified solar still with PCM. The influence of the depth ofwater and the mass of PCM on the performance of the modified solar stillwith PCM has been investigated. The fins were equipped in the basin ofthe solar still to augment evaporation of the basin water. To enhance theheat transfer between the phase change material and the absorber plate,slender shaped fins were welded on the upper of PCM’s chamber. Thecondensation of solar still was increased by using a secondary condenseron the shaded side of single slope solar still. The added secondary con-denser was shielded to keep the surface of the condenser cool. It wasfound that the productivity of the modified solar still in comparisonwith conventional solar still was enhanced during day and night.
- 8 March 2013
- Published by River Publishers in Distributed Generation & Alternative Energy Journal
- p. 6-28
Performance of Single Slope Solar Still with Solar Protected Condenser
To improve the performance of the single slope solar still, an ab-sorber plate with block shaped fins and a Phase Change Material cham-ber (PCM) with slender shaped fins are used. Experimental investiga-tions have been carried out on two solar stills, namely conventional solarstill and a modified solar still with PCM. The influence of the depth ofwater and the mass of PCM on the performance of the modified solar stillwith PCM has been investigated. The fins were equipped in the basin ofthe solar still to augment evaporation of the basin water. To enhance theheat transfer between the phase change material and the absorber plate,slender shaped fins were welded on the upper of PCM’s chamber. Thecondensation of solar still was increased by using a secondary condenseron the shaded side of single slope solar still. The added secondary con-denser was shielded to keep the surface of the condenser cool. It wasfound that the productivity of the modified solar still in comparisonwith conventional solar still was enhanced during day and night.
- Open Access
- 1 January 2013
- Published by National Library of Serbia in Thermal Science
- Vol. 17 (2) , 365-375
Effect of roughness geometry on heat transfer and friction characteristics of PCM storage unit for night coolness storage in summer season
This paper presents a theoretical analysis of thermal storage unit using phase change material (PCM) as storage medium. Storage unit consists of parallel rectangular channels for the air flow which are separated by phase change storage material. The purpose of storage unit is to absorb the night coolness and to provide cooled air at comfort temperature during day time in summer season. MATLsimulation tool has been used to compute the air temperature variation with location as well as time, charging and discharging time of storage unit. Phase change material used for analysis is selected in such a way that it?s Melting point lies between comfort temperature and minimum night ambient temperatures. The air flow rate needed for charging of PCM is approximately four times greater than the flow rate required during day time to achieve comfort temperature for approximately eight hours, due to limited summer night time (only eight hours). The length of storage unit for which NTU value is greater than or equal to five will give the exit air temperature equal to PCM temperature for the case of latent heat utilization. It is found that artificial roughness on the duct surface effectively reduces the length of storage unit in the cost of some extra pressure drop across the duct.
- 1 January 2013
- Published by National Library of Serbia in Thermal Science
- Vol. 17 (2) , 365-375
Open AccessEffect of roughness geometry on heat transfer and friction characteristics of PCM storage unit for night coolness storage in summer season
This paper presents a theoretical analysis of thermal storage unit using phase change material (PCM) as storage medium. Storage unit consists of parallel rectangular channels for the air flow which are separated by phase change storage material. The purpose of storage unit is to absorb the night coolness and to provide cooled air at comfort temperature during day time in summer season. MATLsimulation tool has been used to compute the air temperature variation with location as well as time, charging and discharging time of storage unit. Phase change material used for analysis is selected in such a way that it?s Melting point lies between comfort temperature and minimum night ambient temperatures. The air flow rate needed for charging of PCM is approximately four times greater than the flow rate required during day time to achieve comfort temperature for approximately eight hours, due to limited summer night time (only eight hours). The length of storage unit for which NTU value is greater than or equal to five will give the exit air temperature equal to PCM temperature for the case of latent heat utilization. It is found that artificial roughness on the duct surface effectively reduces the length of storage unit in the cost of some extra pressure drop across the duct.
- Open Access
- 1 September 2012
- Published by Scientific and Academic Publishing in International Journal of Energy Engineering
- Vol. 2 (5) , 253-258
Parametric Studies of a Hybrid Desiccant Cooling System
With the drastically change in climatic conditions in recent years, demand for air conditioning is spreading all over the world. This causes a primary consumption of energy in high quantity. In order to provide the best indoor air quality and thermal comfort with minimum consumption of energy, the hybrid desiccant cooling system is one of the options in our daily life. In this paper, an experimental performance study has been done on the hybrid desiccant cooling system. The effects of various parameters on performance of the system have also been observed. It is found that the influence of the parameters studied on the dehumidification rate is similar to those reported earlier.
- 1 September 2012
- Published by Scientific and Academic Publishing in International Journal of Energy Engineering
- Vol. 2 (5) , 253-258
Open AccessParametric Studies of a Hybrid Desiccant Cooling System
With the drastically change in climatic conditions in recent years, demand for air conditioning is spreading all over the world. This causes a primary consumption of energy in high quantity. In order to provide the best indoor air quality and thermal comfort with minimum consumption of energy, the hybrid desiccant cooling system is one of the options in our daily life. In this paper, an experimental performance study has been done on the hybrid desiccant cooling system. The effects of various parameters on performance of the system have also been observed. It is found that the influence of the parameters studied on the dehumidification rate is similar to those reported earlier.
- 1 August 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 138 (8) , 786-787
Discussion of “Iterative Formulas and EstimationFormulas for Computing Normal Depth of Horseshoe Cross-Section Tunnel”by Jiliang Liu, Zhengzhong Wang, and Xing Fang
- 1 August 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 138 (8) , 786-787
Discussion of “Iterative Formulas and EstimationFormulas for Computing Normal Depth of Horseshoe Cross-Section Tunnel”by Jiliang Liu, Zhengzhong Wang, and Xing Fang
- 19 December 2011
- Published by Taylor & Francis in International Journal of Sustainable Energy
- Vol. 33 (1) , 103-111
Mathematical modelling and experimental investigation of the hybrid desiccant cooling system
In this paper, an experimental study has been conducted on the hybrid desiccant cooling system by removing the latent heat and sensible heat of air separately by mixing it with the desiccant solution in a counter flow manner. This makes air totally dry and thus saves the energy to cool the air in the refrigeration system. The desiccant chosen here is the aqueous solution of calcium chloride. The packed bed inside the absorber as well as the regenerator consists of a polypropylene cascade ring for the efficient mixing of air and desiccant solution. The effects of various parameters such as desiccant inlet temperature, air inlet temperature, mass flow rate of air and desiccant solution have been studied to investigate the performance of the system. Comparing the results with previous studies, a fair agreement has been reported.
- 19 December 2011
- Published by Taylor & Francis in International Journal of Sustainable Energy
- Vol. 33 (1) , 103-111
Mathematical modelling and experimental investigation of the hybrid desiccant cooling system
In this paper, an experimental study has been conducted on the hybrid desiccant cooling system by removing the latent heat and sensible heat of air separately by mixing it with the desiccant solution in a counter flow manner. This makes air totally dry and thus saves the energy to cool the air in the refrigeration system. The desiccant chosen here is the aqueous solution of calcium chloride. The packed bed inside the absorber as well as the regenerator consists of a polypropylene cascade ring for the efficient mixing of air and desiccant solution. The effects of various parameters such as desiccant inlet temperature, air inlet temperature, mass flow rate of air and desiccant solution have been studied to investigate the performance of the system. Comparing the results with previous studies, a fair agreement has been reported.
- Open Access
- 1 November 2011
- Published by Scientific and Academic Publishing in International Journal of Energy Engineering
- Vol. 1 (1) , 1-8
Water Distillation Using Solar Energy System with Lauric Acid as Storage Medium
An experimental investigation on a solar still with lauric acid as phase change material (PCM) is carried out to examine the effect of both the mass of PCM and basin water on the daily distillate productivity and efficiency of the system under outdoor condition. Basic energy balance equations are written to predict the water and glass temperatures, daily distillate productivity and instantaneous efficiency of the single slope solar distillation system with PCM. It is found that the higher mass of PCM with lower mass of water in solar still basin significantly increases the daily productivity and the efficiency. Therefore, the distillate productivity at night and on day for solar still with PCM increased by 127% and 30-35% respectively than without PCM one. Shukla et al. approach of the use of inner glass cover temperature for productivity prediction which has also been investigated, and the prediction shows relatively better agreement with the experimental data than outer glass cover temperature.
- 1 November 2011
- Published by Scientific and Academic Publishing in International Journal of Energy Engineering
- Vol. 1 (1) , 1-8
Open AccessWater Distillation Using Solar Energy System with Lauric Acid as Storage Medium
An experimental investigation on a solar still with lauric acid as phase change material (PCM) is carried out to examine the effect of both the mass of PCM and basin water on the daily distillate productivity and efficiency of the system under outdoor condition. Basic energy balance equations are written to predict the water and glass temperatures, daily distillate productivity and instantaneous efficiency of the single slope solar distillation system with PCM. It is found that the higher mass of PCM with lower mass of water in solar still basin significantly increases the daily productivity and the efficiency. Therefore, the distillate productivity at night and on day for solar still with PCM increased by 127% and 30-35% respectively than without PCM one. Shukla et al. approach of the use of inner glass cover temperature for productivity prediction which has also been investigated, and the prediction shows relatively better agreement with the experimental data than outer glass cover temperature.
- Open Access
- 1 January 2011
- Published by National Library of Serbia in Thermal Science
- Vol. 15 (4) , 995-1009
Finite time thermodynamic analysis and optimization of solar-dish Stirling heat engine with regenerative losses
The present study investigates the performance of the solar-driven Stirling engine system to maximize the power output and thermal efficiency using the non-linearized heat loss model of the solar dish collector and the irreversible cycle model of the Stirling engine. Finite time thermodynamic analysis has been done for combined system to calculate the finite-rate heat transfer, internal heat losses in the regenerator, conductive thermal bridging losses and finite regeneration process time. The results indicate that exergy efficiency of dish system increases as the effectiveness of regenerator increases but decreases with increase in regenerative time coefficient. It is also found that optimal range of collector temperature and corresponding concentrating ratio are 1000 K~1400 K and 1100~1400, respectively in order to get maximum value of exergy efficiency. It is reported that the exergy efficiency of this dish system can reach the maximum value when operating temperature and concentrating ratio are 1150 K and 1300, respectively.
- 1 January 2011
- Published by National Library of Serbia in Thermal Science
- Vol. 15 (4) , 995-1009
Open AccessFinite time thermodynamic analysis and optimization of solar-dish Stirling heat engine with regenerative losses
The present study investigates the performance of the solar-driven Stirling engine system to maximize the power output and thermal efficiency using the non-linearized heat loss model of the solar dish collector and the irreversible cycle model of the Stirling engine. Finite time thermodynamic analysis has been done for combined system to calculate the finite-rate heat transfer, internal heat losses in the regenerator, conductive thermal bridging losses and finite regeneration process time. The results indicate that exergy efficiency of dish system increases as the effectiveness of regenerator increases but decreases with increase in regenerative time coefficient. It is also found that optimal range of collector temperature and corresponding concentrating ratio are 1000 K~1400 K and 1100~1400, respectively in order to get maximum value of exergy efficiency. It is reported that the exergy efficiency of this dish system can reach the maximum value when operating temperature and concentrating ratio are 1150 K and 1300, respectively.