Shiro Miyake
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shiro Miyake has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Narita
Department of Food and Nutrition, Kyoto Women's University , Higashiyama-ku, Kyoto 605-8501, Japan
3 shared publicationsMasahiro Nakajima
Nagoya City Public Health Research Institute, 1-11 Hagiyama-cho, Mizuho-ku, Nagoya 467-8615, Japan
2 shared publicationsMikiko Uchigashima
Research and Development Division, HORIBA, Ltd., Minami-ku, Kyoto 601-8510, Japan
2 shared publicationsYukie Yamaguchi (Murakami)
Kyoto Women’s University, 35 Kitahiyoshi-cho, Imakumano, Higashiyama-ku, Kyoto 605-8501, Japan
2 shared publicationsEiki Watanabe
National Institute for Agro-Environmental Sciences, Tsukuba, Ibaraki 305-8604, Japan
1 shared publicationHiroshi Hamada
Department of Materials Science, Toyohashi University of Technology, Toyohashi, Aichi 441-8580, Japan
1 shared publication
Latest Publications
- 16 June 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (13) , 6711-6717
Development of a Surface Plasmon Resonance-Based Immunosensor for Detection of 10 Major O-Antigens on Shiga Toxin-Producing Escherichia coli, with a Gel Displacement Technique To Remove Bound Bacteria
A surface plasmon resonance-based immunosensor (SPR-immunosensor) was developed for the detection of Shiga toxin-producing Escherichia coli (STEC) belonging to the O-antigen groups O26, O91, O103, O111, O115, O121, O128, O145, O157, and O159. The polyclonal antibodies (PoAbs) generated against each of the STEC O-antigen types in rabbits were purified and were immobilized on the sensor chip at 0.5 mg/mL. The limit of detection for STEC O157 by the SPR-immunosensor was found to be 6.3 × 104 cells for 75 s. Each of the examined 10 O-antigens on the STECs was detected by the corresponding PoAb with almost no reaction to the other PoAbs. The detected STECs were sufficiently removed from the PoAbs using gelatin or agarose gel without deactivation of the PoAbs, enabling repeatable use of the sensor chip. The developed SPR-immunosensor can be applied for the detection of multiple STEC O-antigens. Furthermore, the new antigen removal technique using the gel displacement approach can be utilized with various immunosensors to improve the detection of pathogens in clinical and public health settings.
- 16 June 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (13) , 6711-6717
Development of a Surface Plasmon Resonance-Based Immunosensor for Detection of 10 Major O-Antigens on Shiga Toxin-Producing Escherichia coli, with a Gel Displacement Technique To Remove Bound Bacteria
A surface plasmon resonance-based immunosensor (SPR-immunosensor) was developed for the detection of Shiga toxin-producing Escherichia coli (STEC) belonging to the O-antigen groups O26, O91, O103, O111, O115, O121, O128, O145, O157, and O159. The polyclonal antibodies (PoAbs) generated against each of the STEC O-antigen types in rabbits were purified and were immobilized on the sensor chip at 0.5 mg/mL. The limit of detection for STEC O157 by the SPR-immunosensor was found to be 6.3 × 104 cells for 75 s. Each of the examined 10 O-antigens on the STECs was detected by the corresponding PoAb with almost no reaction to the other PoAbs. The detected STECs were sufficiently removed from the PoAbs using gelatin or agarose gel without deactivation of the PoAbs, enabling repeatable use of the sensor chip. The developed SPR-immunosensor can be applied for the detection of multiple STEC O-antigens. Furthermore, the new antigen removal technique using the gel displacement approach can be utilized with various immunosensors to improve the detection of pathogens in clinical and public health settings.
- 18 January 2012
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 60 (4) , 904-911
Development of an Enzyme-Linked Immunosorbent Assay (ELISA) for Residue Analysis of the Fungicide Azoxystrobin in Agricultural Products
A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) was developed for residue analysis of azoxystrobin in garden crops, for which the maximum residue limits (MRLs) are 0.5–50 mg/kg in Japan. For hapten synthesis, an ethyl carboxyl group was introduced to the 4-position of the 2-cyanophenoxy group in azoxystrobin, and its cyano group was changed to a methyl group. An anti-azoxystrobin monoclonal antibody was prepared from mice immunized with hapten–keyhole limpet hemocyanin conjugate. The dc-ELISA using prepared antibody showed 50–250-fold higher sensitivity compared to the MRLs. The working range of the dc-ELISA was 10–200 ng/mL. The dc-ELISA showed high specificity to azoxystrobin. When methanol extracts from nine kinds of garden crops spiked with azoxystrobin ranging near the MRLs were analyzed, the determined results by the dc-ELISA agreed well with the results of their controls. In addition, azoxystrobin spiked in garden crops homogenates was satisfactorily extracted by methanol solution and easily analyzed. The recovery rate of dc-ELISA was 96–109% and correlated well with the results obtained by HPLC analysis.
- 18 January 2012
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 60 (4) , 904-911
Development of an Enzyme-Linked Immunosorbent Assay (ELISA) for Residue Analysis of the Fungicide Azoxystrobin in Agricultural Products
A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) was developed for residue analysis of azoxystrobin in garden crops, for which the maximum residue limits (MRLs) are 0.5–50 mg/kg in Japan. For hapten synthesis, an ethyl carboxyl group was introduced to the 4-position of the 2-cyanophenoxy group in azoxystrobin, and its cyano group was changed to a methyl group. An anti-azoxystrobin monoclonal antibody was prepared from mice immunized with hapten–keyhole limpet hemocyanin conjugate. The dc-ELISA using prepared antibody showed 50–250-fold higher sensitivity compared to the MRLs. The working range of the dc-ELISA was 10–200 ng/mL. The dc-ELISA showed high specificity to azoxystrobin. When methanol extracts from nine kinds of garden crops spiked with azoxystrobin ranging near the MRLs were analyzed, the determined results by the dc-ELISA agreed well with the results of their controls. In addition, azoxystrobin spiked in garden crops homogenates was satisfactorily extracted by methanol solution and easily analyzed. The recovery rate of dc-ELISA was 96–109% and correlated well with the results obtained by HPLC analysis.
- 14 October 2009
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 57 (19) , 8728-8734
Development of a Novel Immunoaffinity Column for Aflatoxin Analysis Using an Organic Solvent-Tolerant Monoclonal Antibody
An organic solvent-tolerant monoclonal antibody specific to aflatoxins B1, B2, G1, G2, and M1 (AFB1, AFB2, AFG1, AFG2, and AFM1) was prepared. In an indirect competitive enzyme-linked immunosorbent assay, the half maximal inhibitory concentration (IC50) values were 1.9, 2.1, 2.1, 2.4, and 2.8 ng/mL for AFB1, AFB2, AFG1, AFG2, and AFM1, respectively. Antibody reactivity was retained at 40% methanol concentration or at acetonitrile concentrations up to 40%. An immunoaffinity column (IAC) was prepared using agarose gel beads with bound antibody. The IAC retained the tested AFs that were 89, 90, 95, 90, and 89% for AFB1, AFB2, AFG1, AFG2, and AFM1 at 20% acetonitrile concentrations or that were 81, 87, 79, and 83% for AFB1, AFB2, AFG1, and AFG2 at 60% methanol concentrations. Roasted peanuts and seven kinds of spices were spiked with 8.0, 1.0, 6.0, and 1.0 ng for AFB1, AFB2, AFG1, and AFG2 per 1 g sample and extracted with 90% acetonitrile. The roasted peanuts and cayenne pepper out of the spices were also extracted with 70% methanol. The extracts were diluted 5-fold with phosphate-buffered saline and applied to the IAC. The spiked aflatoxins were recovered with satisfactory rates: 78 (RSD, 2.1%) to 127% (RSD, 1.7%). The developed IAC was used for the analysis of aflatoxins in naturally contaminated samples of roasted peanuts and cayenne pepper. The newly developed IAC showed substantially organic solvent tolerance at the concentration that could not be used for existing IACs, and the column showed good ability to clean up samples for food analysis.
- 14 October 2009
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 57 (19) , 8728-8734
Development of a Novel Immunoaffinity Column for Aflatoxin Analysis Using an Organic Solvent-Tolerant Monoclonal Antibody
An organic solvent-tolerant monoclonal antibody specific to aflatoxins B1, B2, G1, G2, and M1 (AFB1, AFB2, AFG1, AFG2, and AFM1) was prepared. In an indirect competitive enzyme-linked immunosorbent assay, the half maximal inhibitory concentration (IC50) values were 1.9, 2.1, 2.1, 2.4, and 2.8 ng/mL for AFB1, AFB2, AFG1, AFG2, and AFM1, respectively. Antibody reactivity was retained at 40% methanol concentration or at acetonitrile concentrations up to 40%. An immunoaffinity column (IAC) was prepared using agarose gel beads with bound antibody. The IAC retained the tested AFs that were 89, 90, 95, 90, and 89% for AFB1, AFB2, AFG1, AFG2, and AFM1 at 20% acetonitrile concentrations or that were 81, 87, 79, and 83% for AFB1, AFB2, AFG1, and AFG2 at 60% methanol concentrations. Roasted peanuts and seven kinds of spices were spiked with 8.0, 1.0, 6.0, and 1.0 ng for AFB1, AFB2, AFG1, and AFG2 per 1 g sample and extracted with 90% acetonitrile. The roasted peanuts and cayenne pepper out of the spices were also extracted with 70% methanol. The extracts were diluted 5-fold with phosphate-buffered saline and applied to the IAC. The spiked aflatoxins were recovered with satisfactory rates: 78 (RSD, 2.1%) to 127% (RSD, 1.7%). The developed IAC was used for the analysis of aflatoxins in naturally contaminated samples of roasted peanuts and cayenne pepper. The newly developed IAC showed substantially organic solvent tolerance at the concentration that could not be used for existing IACs, and the column showed good ability to clean up samples for food analysis.