SBSteven J. Barker

Steven J. Barker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steven J. Barker has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Pro-Con Debate: Should Code Sharing Be Mandatory for Publication?

    by Ryan L. Melvin, Steven J. Barker, Joe Kiani, Dan E. Berkowitz

    In this Pro-Con commentary article, we discuss whether or not code sharing should be mandatory for scientific publications. Scientific programming is an increasingly prevalent tool in research. However, there are not unified guidelines for code availability requirements. Some journals require code sharing. Others require code descriptions. Yet others have no policies around code sharing. The Pro side presented here argues that code sharing should be mandatory for all scientific publications involving code. This Pro argument comes in 2 parts. First, any defensible reason for not sharing code is an equally valid a reason for the manuscript itself not being published. Second, lack of code sharing requirements creates 2 tiers of science: one where reproducibility is required and one where it is not. Additionally, the Pro authors suggest that a debate over code sharing is itself a decade out-of-date due to the emerging availability of containerization and virtual environment sharing software. The Pro argument concludes with an appeal that authors release code to make their work more understandable by other researchers. The Con side presented here argues that computer source codes of medical technology equipment should not be subject to mandatory public disclosure. The source code is a crucial part of what makes a particular device unique and allows that device to outperform its competition. The Con authors believe that public disclosure of this proprietary information would destroy all incentives for businesses to develop new and improved technologies. Competition in the free marketplace is what drives companies to constantly improve their products, to develop new and better medical devices. The open disclosure of these “trade secret” details would effectively end that competitive drive. Why invest time, money, and energy developing a “better mousetrap” if your competitors can copy it and produce it the next day?


  • Open Access

    Continuous Noninvasive Hemoglobin Monitoring

    by Steven J. Barker, Aryeh Shander, Michael A. Ramsay

    Supplemental Digital Content is available in the text.


  • The measurement of dyshemoglobins and total hemoglobin by pulse oximetry

    by Steven J Barker, John J Badal

    Recent advances in pulse oximetry have made it possible to noninvasively measure total hemoglobin, as well as the two most common dyshemoglobins. This review will trace the development and clinical application of multiwavelength pulse oximetry. Until now, commercially produced pulse oximeters have utilized two wavelengths of light and could measure only the ratio of oxyhemoglobin to total hemoglobin, displayed as SpO2. Pulse oximeters using up to 12 light wavelengths have recently been developed by Masimo Corp. (Irvine, California, USA). These new 'Rainbow Pulse CO-oximeter' instruments can estimate blood levels of carboxyhemoglobin, methemoglobin, and total hemoglobin (SpHb), as well as the conventional SpO2 value. The accuracy of these new measurements has been studied in human volunteers and clinical trials. Some interesting case reports have documented the use of this new technology in diagnosis and treatment. The development of multiwavelength pulse oximeters, which can measure total hemoglobin as well as dyshemoglobins, should result in improved patient care.


  • Measurement of Carboxyhemoglobin and Methemoglobin by Pulse Oximetry

    by Steven J. Barker, Jeremy Curry, Daniel Redford, Scott Morgan

    Background: A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. Methods: Ten volunteers breathed 500 ppm carbon monoxide until their carboxyhemoglobin levels reached 15%, and 10 different volunteers received intravenous sodium nitrite, 300 mg, to induce methemoglobin. All were instrumented with arterial cannulas and six Masimo Rad-57 (Masimo Inc., Irvine, CA) pulse oximeter sensors. Arterial blood was analyzed by three laboratory CO-oximeters, and the resulting carboxyhemoglobin and methemoglobin measurements were compared with the corresponding pulse oximeter readings. Results: The Rad-57 measured carboxyhemoglobin with an uncertainty of +/-2% within the range of 0-15%, and it measured methemoglobin with an uncertainty of 0.5% within the range of 0-12%. Conclusion: The Masimo Rad-57 is the first commercially available pulse oximeter that can measure methemoglobin and carboxyhemoglobin, and it therefore represents an expansion of our oxygenation monitoring capability.


  • “Motion-Resistant” Pulse Oximetry: A Comparison of New and Old Models

    by Steven J. Barker

    Several pulse oximeter manufacturers have recently developed instruments that are claimed to be resistant to the effects of patient motion. We performed a laboratory volunteer experiment to compare the performances of several of these instruments, as well as some older models, during combinations of motion and hypoxemia. Twenty oximeters were studied. A motorized table produced different hand motions, and each motion was studied during both room air breathing and hypoxemia. Pulse oximeters on the nonmoving hand were used to provide control measurements for comparison. The Masimo SET((R)) pulse oximeter exhibited the best overall performance, with a performance index (percentage of time in which the SpO(2) reading is within 7% of control value) of 94%. The Agilent Viridia 24C was next, with an 84% index, followed by the Agilent CMS (80%), the Datex-Ohmeda 3740 (80%), and the Nellcor N-395 (69%). For comparison with older oximeter technology, the Criticare 5040 had an index of 28%. Recent technology changes have significantly improved pulse oximeter performance during motion artifact, with the Masimo oximeter leading the way. IMPLICATIONS. New improvements in pulse oximeter technology have resulted in significantly better accuracy and reliability during patient motion. The Masimo pulse oximeter demonstrated the best performance of the 20 instruments tested.


    • 1 January 2002
      • Vol. 94, S17-20

    Standardization of the testing of pulse oximeter performance.

    by Steven J Barker

  • Fire in the Operating Room: A Case Report and Laboratory Study

    by Steven J. Barker, J. Scott Polson

    In July, 1998 a fire occurred in an operating room (OR) at the University Medical Center in Tucson, AZ. A patient was burned on the face, neck, and shoulders by the fire, which started during cranial burr-hole placement under monitored anesthesia care. This paper describes the actual case in some detail. The incident was simulated as accurately as possible in a laboratory experiment, in an attempt to determine specific risk factors for this event. The experiment found that a specific combination of factors was required to produce a fire similar in appearance to the one in the OR. The risk factors determined in these experiments are discussed in the context of previous reports of OR fires. Although other reports demonstrate some common characteristics of these events, the fire at the University Medical Center appears to be unique within the literature regarding the specific chain of events that led up to it.


  • Lord or Vassal? Academic Anesthesiology Finances in 2000

    by Steven J. Barker

    This article examines recent trends in the management of academic physician practice groups, and in particular the allocation of revenues and expenses to anesthesiology departments. The history of academic group practice is traced, beginning with the “corporate model,” in which each department functioned in financial independence from the others. This evolved gradually into the “feudal system,” in which departments were ostensibly independent, but paid variable and often large “assessments” to the central group. The final stage in this evolution is the “big bag,” in which all clinical revenue is pooled by the central practice group, and then distributed by the group to departments or individuals according to some compensation plan formula. The advantages and disadvantages of each of these systems are discussed as they apply to anesthesiology departments. A productivity-based compensation plan formula under the big bag system is calculated for a typical anesthesiology department. This calculation shows that if the compensation formula is truly based on measured clinical productivity, anesthesiology departments may actually fare better under the big bag than under the feudal system. Finally, options for survival in the academic practice groups of the future are discussed. Implications The history, current status, and trends of finances in academic anesthesiology departments are reviewed. Knowledge of these issues will help departments develop funds allocation methods to ensure that they receive an appropriate share of their faculty practice group’s clinical income.


  • Open Access

    Blood Volume Measurement

    by Steven J. Barker