CCClaudine Caron

Claudine Caron

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Claudine Caron has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Measurement of von Willebrand factor binding to a recombinant fragment of glycoprotein Ibα in an enzyme‐linked immunosorbent assay‐based method: performances in patients with type 2B von Willebrand disease

    by Claudine Caron, Lysiane Hilbert, Karen Vanhoorelbeke, Hans Deckmyn, Jenny Goudemand, Claudine Mazurier

    Type 2B von Willebrand disease (VWD) is characterised by an increased affinity of von Willebrand factor (VWF) for its platelet receptor glycoprotein Ib (GPIb). This feature is usually studied in vitro by a ristocetin-dependent VWF platelet-binding assay, which has some limitations as it requires [e.g. (radio)-labelled anti-VWF antibodies and normal formaldehyde-fixed platelets]. We, here, extended the applicability of an enzyme-linked immunosorbent assay-based method previously described for the measurement of ristocetin co-factor activity that used a recombinant fragment of GPIb (rfGPIb alpha) and horseradish peroxidase-labelled rabbit anti-human VWF antibodies for measuring the captured ristocetin-VWF complexes on the rfGPIb alpha. Thirty-one type 2B VWD patients from 15 families with eight different known mutations were studied. VWF in plasma from 28 of these patients bound better than normal VWF at 0.2 mg/ml ristocetin, with the ratio, optical density (OD) patient/OD normal pool plasma, higher than 1.8. For two of the three other patients with no enhanced response of plasma VWF, the platelet lysate VWF showed an enhanced binding capacity; for the last patient, the results in other members of the family are unequivocal. We conclude that, this new method for measurement of plasma or platelet VWF-binding capacity offers great advantages for correct type 2B VWD diagnosis.


  • Content and functional activity of von Willebrand factor in apheresis plasma

    by T. Burnouf, C. Caron, T. Burkhardt, J. Goudemand

    Von Willebrand Factor (VWF) is a complex high-molecular-weight (HMW) plasma glycoprotein playing a critical role in primary and secondary haemostasis. Owing to its multimeric structure and sensitivity to proteolysis, VWF can be used as a marker of the impact of collection procedures on the characteristics of plasma for transfusion and for fractionation. We studied VWF content, functional activity and HMW multimers in plasmas collected by five different automated apheresis collection procedures. Five series of 30 plasma units were obtained from volunteer donors at two collection sites using Haemonetics PCS2 machines with Revision (Rev) F, Rev G, high-separation core (HSC), or filter core (FC) procedures, or Baxter-Fenwall Autopheresis-C (Auto-C). VWF antigen (VWF:Ag), ristocetin cofactor (VWF:RCo) activity and HMW multimers were first determined in 10 randomly selected plasma donations collected with Rev G, HSC, FC and Auto-C procedures. Then, the same analyses and the collagen binding (VWF:CB) activity were determined in the pools of 30 donations from each of the five procedures and compared with two normal plasma pools (NPP1 and NPP2). A reference plasma (RP) was used to calibrate each assay. There were a greater number of group O individuals in the Rev F, Rev G and FC donors than in the HSC and Auto-C donors. The mean VWF:Ag level was > 100 IU/dl, VWF:RCo activity was > 90 U/dl, the VWF:RCo/Ag ratio was close to 1, and the percentage of 11-15 mers was above 100% of RP in the 10 individual plasma units from Rev G, HSC, FC, and Auto-C and in their respective pools. The mean percentage of multimers > 15 mers, relative to RP, was significantly less in Rev G plasmas (48 +/- 17%; range 32-91%), compared with Auto-C, HSC and FC plasmas (P = 0.0211; 0.0257; and 0.0376, respectively). The VWF:CB activity of the 30-donation pools was 61 and 60 U/dl in Auto C and HSC, 50 U/dl in Rev F and FC, and 43 U/dl in the Rev G pool. The VWF:CB/Ag ratio was 0.54 (Auto-C), 0.49 (HSC), 0.46 (Rev F), 0.45 (FC) and 0.37 (Rev G), compared with 0.81and 0.92 in NPPs. The percentage of VWF multimers of 11-15 mers in apheresis plasma and NPP was normal. VWF multimers > 15 mers ranged from 38 to 64% of that of RP plasma, and was 111 and 112% in NPPs. The VWF:Ag, VWF:RCo activity and 11-15 mer VWF multimers were well preserved in all plasma units from each of the five apheresis procedures. The VWF:CB activity and the percentage of multimers > 15 mers in apheresis plasma was less than in normal plasma pools and differed slightly among procedures.


  • A blinded in vitro study with Refacto® mock plasma samples: similar FVIII results between the chromogenic assay and a one‐stage assay when using a higher cephalin dilution

    by C. Caron, M‐D. Dautzenberg, B. Delahousse, C. Droulle, P. Pouzol, A. Dubanchet, C. Rothschild

    Summary.  Assay of factor VIII (FVIII) in patient samples is routinely carried out using the one‐stage assay rather than the chromogenic substrate assay. The introduction of new FVIII preparations for the treatment of haemophilia A, including immunopurified FVIII and particularly, recombinant FVIII (rFVIII) concentrates, has led to discrepancies between the results obtained with the two assays. In patients treated with rFVIII concentrates, FVIII levels measured with the one‐stage assay can be 20–50% lower than those measured with the chromogenic assay. In this study, the one‐stage assay was performed with cephalin dilutions higher than those recommended by the manufacturer. B‐domain‐deleted recombinant FVIII, Refacto®, was diluted to eight different concentrations, ranging from 1–100 IU dL−1, in FVIII‐deficient plasma and the FVIII activity of the eight solutions was determined by the chromogenic method in a central laboratory. Aliquots were then assayed by the one‐stage method in the four participating laboratories, using different dilutions of CK‐Prest®. When CK‐Prest® was reconstituted according to the manufacturer's recommendations (dilution 1 : 1), the difference between the one‐stage and chromogenic methods was close to 30%. CK‐Prest® cephalin dilutions of 1 : 5 and 1 : 8 gave very similar results with the two methods, without increasing the interlaboratory coefficient of variation. These findings confirm the influence of phospholipids on the one‐stage assay, particularly the importance of using a phospholipid concentration close to the physiological value in platelets. Thismodified one‐stage method may therefore offer an alternative to the use of a concentrate‐specific standard.


    • 1 August 2001
      • Vol. 86  (2) , 584-9

    Quantification of lupus anticoagulants in clinical samples using anti-beta2GP1 and anti-prothrombin monoclonal antibodies.

    by A Le Querrec, J Arnout, D Arnoux, J Y Borg, C Caron, L Darnige, B Delahousse, G Reber, P Sié

    Quantification of lupus anticoagulant (LA) in clinical samples is hampered by the lack of a suitable standard of activity. We evaluated the use of mAbs displaying LA activity for this purpose. As most patient samples contain both beta2Glycoprotein I (beta2GP1) and prothrombin dependent LA, a combination of two mAbs, one of each specificity, was added to normal plasma in a concentration from 0 to 60 microg/ml. Eight assay systems using different reagents and instruments were used. The calibration curves were linear for all but one, with marked differences between the responsiveness to each mAb. A panel of plasmas from 69 patients with persistent LA diagnosed using the SSC-ISTH criteria was tested. An antiphospholipid syndrome (APS) was present in 40, whereas 29 were asymptomatic. LA activities of individual plasmas varied between assays (p < 10(-4)), but homogeneous subgroups were identified. In a majority of samples, LA activity displayed a prothrombin-dependent profile, with a variable contribution of beta2GP1-dependent activity. The latter was associated to beta2GP1 antibodies detected by solid-phase immunoassay. By using 3 dilute Russell viper venom time assays, higher LA titers were found in APS, compared to asymptomatic patients (p <0.05).


    • 15 December 2000
      • Vol. 96  (13) , 4373-5

    Unbalanced X-chromosome inactivation with a novel FVIII gene mutation resulting in severe hemophilia A in a female.

    by R Favier, J M Lavergne, J M Costa, C Caron, C Mazurier, M Viémont, M Delpech, S Valleix

    This report is of a 14-month-old girl affected with severe hemophilia A. Both her parents had normal values for factor VIII activity, and von Willebrand disease type 2N was excluded. Karyotype analysis demonstrated no obvious alteration, and BclI Southern blot did not reveal F8 gene inversions. Direct sequencing of F8 gene exons revealed a frameshift-stop mutation (Q565delC/ter566) in the heterozygous state in the proposita only. F8 gene polymorphism analysis indicated that the mutation must have occurred de novo in the paternal germline. Furthermore, analysis of the pattern of X chromosome methylation at the human androgen receptor gene locus demonstrated a skewed inactivation of the derived maternal X chromosome from the lymphocytes of the proband's DNA. Thus, the severe hemophilia A in the proposita results from a de novo F8 gene frameshift-stop mutation on the paternally derived X chromosome, associated with a nonrandom pattern of inactivation of the maternally derived X chromosome. (Blood. 2000;96:4373-4375)


    • 1 December 1998
      • Vol. 80  (6) , 919-24

    A cross-over pharmacokinetic study of a double viral inactivated factor IX concentrate (15 nm filtration and SD) compared to a SD factor IX concentrate.

    by J Goudemand, J Peynet, H Chambost, C Négrier, M E Briquel, S Claeyssens, A Derlon-Borel, C Guérois, C Caron, J M Scherrmann, et al.

    A double blind randomized cross-over multi-center study has been conducted to compare the pharmacokinetic and coagulation activation markers of high-purity factor IX concentrate subjected to both solvent/ detergent (SD) treatment and 15 nm-filtration (FIX-SD-15) with the licensed product subjected only to solvent-detergent (FIX-SD). This filtration process allows the elimination of small particles, such as non-enveloped viruses (i.e., hepatitis A and parvovirus B19). Eleven severe hemophilia B patients (FIX coagulant activity <2 IU/dl) received one infusion of 60 IU/kg of FIX-SD and one infusion of 60 IU/kg of FIX-SD-15 at least at 10 days interval. Blood samples were obtained before and at various time up to 72 h after infusion. The decay curves of factor IX (FIX:C and FIX:Ag) were evaluated by a model independent method. Bioequivalence was found between the two concentrates using the Schuirmann test. The mean FIX:C and FIX:Ag recovery of FIX-SD-15 was 1.08 and 0.89 IU/dl/IU/kg respectively with a mean half-life of 33.3 h for FIX:C and 25.6 h for FIX:Ag. Six months after initial enrollment, pharmacokinetic parameters were similar in the 7 patients tested. There was no significant variation of prothrombin fragment 1+2 and thrombin-antithrombin complexes measured up to 6 h after infusion, indicating that there was no activation process after administration of FIX. In conclusion, these data demonstrate that the introduction of a 15 nm filtration does not alter the pharmacokinetic profile of a well characterized SD FIX concentrate while providing additional viral safety.


    • 1 July 1998
      • Vol. 80  (1) , 99-103

    Control of oral anticoagulation in patients with the antiphospholipid syndrome--influence of the lupus anticoagulant on International Normalized Ratio. Groupe Méthodologie en Hémostase du Groupe d'Etudes sur l'Hémostases et la Thrombose.

    by A Robert, A Le Querrec, B Delahousse, C Caron, L Houbouyan, B Boutière, M H Horellou, G Reber, P Sié

    The recommended therapeutic range of International Normalized Ratio (INR) for oral anticoagulant treatment in patients with the antiphospholipid syndrome remains controversial. As a part of this controversy, it has been suggested that lupus anticoagulants (LA) could interfere with the determination of prothrombin time, thus questioning the validity of monitoring the treatment of these patients using INR. To clarify this point, we compared the values of INR obtained in the plasmas of two groups of patients, one without LA (n = 47), and the other with LA (n = 43). INR were determined using 8 different thromboplastin reagents on the same automated coagulation instrument. Chromogenic factor X, which is supposed to be insensitive to the presence of LA, was also measured. The results are the following: provided INR was calculated using calibrated reference plasmas, there was no significant difference between INR values obtained with the 8 reagents, both in the non-LA and in the LA groups (CV: 5.9 and 6.7%. respectively). Closer examination revealed that INR results obtained with one reagent (the recombinant thromboplastin Innovin) diverged from those of the 7 others, leading to an overestimation of INR, to a very large extent in some instances. However this effect was restricted to a subset of the patient population with LA (6 out of 43). Finally, the relationship between INR (average value obtained using the 8 reagents) and factor X was identical in non-LA and in LA patient groups. We conclude that, provided the reagents which display the LA interference are identified and excluded for this purpose, the INR system is valid for monitoring oral anticoagulant treatment in patients with LA.


    • 1 January 1991
      • Vol. 33  (2)

    Haemostatic and proteolytic markers in acute non lymphoid leukemia: a source of multiple informations.

    by J Goudemand, C Caron, B Quesnel

  • MODERATE DECREASE OF FACTOR VII AND PROTEIN C WITHOUT OCCURRENCE OF HEPATIC VENO-OCCLUSIVE DISEASE AFTER ALLOGENEIC BONE MARROW TRANSPLANTATION IN 18 PATIENTS TREATED WITH LOW DOSE HEPARIN

    by C Caron, J P Jouet, J Himpens, P Hives, H Gruson, J Goudemand

    Decrease of factor VII (F VII) and protein C (PC) has been said to allow an early detection of hepatic veno-occlusive disease (VOD) (VILMER, Path. Biol. 1986, 34 : 79), that represents a serious complication of bone marrow transplantation (BMT). In this purpose, F VII (activity) and PC (antigen) have been measured in 18 patients (aged 9 to 45 yr- m : 26 yr) who underwent allogeneic bone marrow graft for chronic myelogenous leukemia (9 cases), acute lymphocytic leukemia (7 cases) acute myelogenous leukemia (2 cases). All patients received as preparation for BMT total body irradiation (mean dose = 10 Gy) along with cyclophosphamide (120 mg/Kg). All were given low dose heparin (100 UI/Kg/24 hr) from days -7 to +30. None of the patients developed VOD but graft-versus-host disease occurred in 13 out of them between days 18 and 52. Moreover, coagulation studies performed from days 1 to 28 detected a moderate decrease of F VII and PC (maximum on day 11). These parameters were normalized on day 28. The level of the other vitamin K-dependent factors was not significantly changed.So the moderate decrease of F VII and PC found in the post-graft period was not associated with hepatic VOD. However, as none of the patients developed this complication, these results do not exclude that a major decrease of these parameters could serve as an early diagnosis of VOD. On the other hand, a prophylactic effect of low dose heparin cannot be ruled out.

    • 22 September 1984
      • Vol. 13  (32) , 1964

    [Appearance and disappearance of an antifactor VIII antibody in Horton's disease].

    by J P Rouget, J Goudemand, C Caron, A Destee, P Dewailly, A Cosson