E. Viguier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
E. Viguier has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
P. Maitre
CHEV, Vet Agro Sup , Campus Vétérinaire de Lyon, Lyon, France
8 shared publicationsT. Lequang
Université Vétérinaire de Hoshimine Ville , Ho Chi Minh City, Viet Nam
5 shared publicationsA. Colin
Université de Lyon, Ecole Nationale Vétérinaire de Lyon
4 shared publications- P. Maitre
Unité de chirurgie, École Nationale vétérinaire de Lyon (ENVL), 69280 Marcy-l’Étoile, France
4 shared publications - Thierry Roger
Université de Lyon, Ecole Nationale Vétérinaire de Lyon
4 shared publications T. Cachon
CHEV, Vet Agro Sup , Campus Vétérinaire de Lyon, Lyon, France ; RTI2B, Laboratoire , «Réparation Tissulaire, Interaction Biologique et Biomatériaux», Vet Agro Sup , Campus Vétérinaire de Lyon, Lyon, France
3 shared publications
Latest Publications
- 30 July 2014
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (sup1) , 66-67
Influence of age and localisation on pedicle fixation in immature porcine spines
- 30 July 2014
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (sup1) , 66-67
Influence of age and localisation on pedicle fixation in immature porcine spines
- 1 April 2011
- Published by Elsevier in Pratique Médicale et Chirurgicale de l'Animal de Compagnie
- Vol. 46 (2) , 55-56
Anomalies laryngées entraînant une dyspnée majeure chez trois Bull-Terriers miniatures : une nouvelle entité ?
- 1 April 2011
- Published by Elsevier in Pratique Médicale et Chirurgicale de l'Animal de Compagnie
- Vol. 46 (2) , 55-56
Anomalies laryngées entraînant une dyspnée majeure chez trois Bull-Terriers miniatures : une nouvelle entité ?
- 31 August 2010
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 13 (sup1) , 41-42
Morphometric analysis of vertebral deformities in a porcine scoliosis model
- 31 August 2010
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 13 (sup1) , 41-42
Morphometric analysis of vertebral deformities in a porcine scoliosis model
- 31 August 2010
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 13 (sup1) , 61-62
Sensitivity and specificity to determine lameness in dogs with a pressure walkway system
(2010). Sensitivity and specificity to determine lameness in dogs with a pressure walkway system. Computer Methods in Biomechanics and Biomedical Engineering: Vol. 13, 35th Congress of the Société de Bioméchanique, pp. 61-62.
- 31 August 2010
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 13 (sup1) , 61-62
Sensitivity and specificity to determine lameness in dogs with a pressure walkway system
(2010). Sensitivity and specificity to determine lameness in dogs with a pressure walkway system. Computer Methods in Biomechanics and Biomedical Engineering: Vol. 13, 35th Congress of the Société de Bioméchanique, pp. 61-62.
- Open Access
- 20 January 2010
- Published by Springer Nature in BMC Medical Imaging
- Vol. 10 (1) , 3
Radiographic assessment of the femorotibial joint of the CCLT rabbit experimental model of osteoarthritis
Background: The purposes of the study were to determine the relevance and validity of in vivo non-invasive radiographic assessment of the CCLT (Cranial Cruciate Ligament Transection) rabbit model of osteoarthritis (OA) and to estimate the pertinence, reliability and reproducibility of a radiographic OA (ROA) grading scale and associated radiographic atlas. Methods: In vivo non-invasive extended non weight-bearing radiography of the rabbit femorotibial joint was standardized. Two hundred and fifty radiographs from control and CCLT rabbits up to five months after surgery were reviewed by three readers. They subsequently constructed an original semi-quantitative grading scale as well as an illustrative atlas of individual ROA feature for the medial compartment. To measure agreements, five readers independently scored the same radiographic sample using this atlas and three of them performed a second reading. To evaluate the pertinence of the ROA grading scale, ROA results were compared with gross examination in forty operated and ten control rabbits. Results: Radiographic osteophytes of medial femoral condyles and medial tibial condyles were scored on a four point scale and dichotomously for osteophytes of medial fabella. Medial joint space width was scored as normal, reduced or absent. Each ROA features was well correlated with gross examination (p < 0.001). ICCs of each ROA features demonstrated excellent agreement between readers and within reading. Global ROA score gave the highest ICCs value for between (ICC 0.93; CI 0.90-0.96) and within (ICC ranged from 0.94 to 0.96) observer agreements. Among all individual ROA features, medial joint space width scoring gave the highest overall reliability and reproducibility and was correlated with both meniscal and cartilage macroscopic lesions (rs = 0.68 and rs = 0.58, p < 0.001 respectively). Radiographic osteophytes of the medial femoral condyle gave the lowest agreements while being well correlated with the macroscopic osteophytes (rs = 0.64, p < 0.001). Conclusion: Non-invasive in vivo radiography of the rabbit femorotibial joint is feasible, relevant and allows a reproducible grading of experimentally induced OA lesion. The radiographic grading scale and atlas presented could be used as a template for in vivo non invasive grading of ROA in preclinical studies and could allow future comparisons between studies.
- 20 January 2010
- Published by Springer Nature in BMC Medical Imaging
- Vol. 10 (1) , 3
Open AccessRadiographic assessment of the femorotibial joint of the CCLT rabbit experimental model of osteoarthritis
Background: The purposes of the study were to determine the relevance and validity of in vivo non-invasive radiographic assessment of the CCLT (Cranial Cruciate Ligament Transection) rabbit model of osteoarthritis (OA) and to estimate the pertinence, reliability and reproducibility of a radiographic OA (ROA) grading scale and associated radiographic atlas. Methods: In vivo non-invasive extended non weight-bearing radiography of the rabbit femorotibial joint was standardized. Two hundred and fifty radiographs from control and CCLT rabbits up to five months after surgery were reviewed by three readers. They subsequently constructed an original semi-quantitative grading scale as well as an illustrative atlas of individual ROA feature for the medial compartment. To measure agreements, five readers independently scored the same radiographic sample using this atlas and three of them performed a second reading. To evaluate the pertinence of the ROA grading scale, ROA results were compared with gross examination in forty operated and ten control rabbits. Results: Radiographic osteophytes of medial femoral condyles and medial tibial condyles were scored on a four point scale and dichotomously for osteophytes of medial fabella. Medial joint space width was scored as normal, reduced or absent. Each ROA features was well correlated with gross examination (p < 0.001). ICCs of each ROA features demonstrated excellent agreement between readers and within reading. Global ROA score gave the highest ICCs value for between (ICC 0.93; CI 0.90-0.96) and within (ICC ranged from 0.94 to 0.96) observer agreements. Among all individual ROA features, medial joint space width scoring gave the highest overall reliability and reproducibility and was correlated with both meniscal and cartilage macroscopic lesions (rs = 0.68 and rs = 0.58, p < 0.001 respectively). Radiographic osteophytes of the medial femoral condyle gave the lowest agreements while being well correlated with the macroscopic osteophytes (rs = 0.64, p < 0.001). Conclusion: Non-invasive in vivo radiography of the rabbit femorotibial joint is feasible, relevant and allows a reproducible grading of experimentally induced OA lesion. The radiographic grading scale and atlas presented could be used as a template for in vivo non invasive grading of ROA in preclinical studies and could allow future comparisons between studies.
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 62-66
Gait Analysis for Sound Dogs at a Walk by Using a Pressure Walkway
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 62-66
Gait Analysis for Sound Dogs at a Walk by Using a Pressure Walkway
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 830-832
Porcine Scoliosis Model Based on Animal Growth Created with Non Invasive Off-Set Tethering
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 830-832
Porcine Scoliosis Model Based on Animal Growth Created with Non Invasive Off-Set Tethering
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 827-829
Morphometric Analysis of Vertebral Deformities in a Porcine Scoliosis Model
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 827-829
Morphometric Analysis of Vertebral Deformities in a Porcine Scoliosis Model
- 12 August 2009
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 12 (sup1) , 199-200
Porcine scoliosis model based on animal growth created with non-invasive off-set tethering
- 12 August 2009
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 12 (sup1) , 199-200
Porcine scoliosis model based on animal growth created with non-invasive off-set tethering
- 1 January 2008
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 11 (sup001) , 137-138
Spatial, temporal and kinetic evaluation of normal cats at walk, using a pressure walkway
- 1 January 2008
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 11 (sup001) , 137-138
Spatial, temporal and kinetic evaluation of normal cats at walk, using a pressure walkway