Theodore Velissaris
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Theodore Velissaris has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Sunil K Ohri
2 shared publicationsAlison Calver
1 shared publication- Amit Modi
Sussex Cardiac Centre, Brighton, UK
1 shared publication Augustine T.M. Tang
Department of Cardiac Surgery, Wessex Cardiothoracic Centre, Southampton General Hospital, Tremona Road, Southampton SO16 6YD, United Kingdom
1 shared publicationClifford Barlow
1 shared publicationDavid A. Hett
Department of Anaesthesia, Southampton General Hospital, Southampton, United Kingdom
1 shared publication
Latest Publications
- 1 May 2014
- Vol. 23 (3) , 325-32
Early in-vivo hemodynamic comparison of supra-annular aortic bioprostheses: Trifecta versus Perimount Magna Ease.
The study aim was to compare early postoperative hemodynamic gradients after supra-annular implantation of the Trifecta and Perimount Magna Ease aortic bioprostheses. Between January 2010 and December 2011, a total of 235 patients (105 males, 130 females; mean age at surgery 73.8 +/- 10.2 years) underwent supra-annular aortic valve replacement (AVR), with or without concomitant procedures. The patients were divided into 2 groups receiving either the Perimount Magna Ease (n = 117) or Trifecta (n = 118). Concomitant procedures were performed in 133 patients (56.6%), and 25 procedures (10.6%) were redos. Patients with postoperative severe left ventricular dysfunction and moderate to severe mitral regurgitation were excluded. Gradients were calculated pre-discharge using transthoracic echocardiography. Effective orifice area calculations were not performed. Data were collected retrospectively from hospital databases and analyzed using SPSS 17. Both groups compared well for 14 variables. Group A had a higher number of redo operations and the patients were younger. Postoperative peak and mean gradients (in mmHg) for the Magna Ease group versus Trifecta group were: 19 mm valves, 33.5 +/- 16 versus 24.7 +/- 10 (p = 0.11) and 17.4 +/- 6.5 versus 12.7 +/- 4.4 (p = 0.05); 21 mm, 27.2 +/- 9.1 versus 21.8 +/- 7.2 (p = 0.001) and 13.8 +/- 4.7 versus 10.7 +/- 3.4 (p = 0.001); 23 mm, 25.6 +/- 7.8 versus 20.1 +/- 7.9 (p = 0.005) and 13 +/- 4 versus 10.1 +/- 4.3 (p = 0.002); 25 mm, 22.3 +/- 7.8 versus 15.6 +/- 5.1 (p = 0.01) and 12.8 +/- 4.1 versus 8 +/- 2.8 (p = 0.02). The overall mortality was 3.4%. The median hospital stay was nine days in both groups (p = 0.13). Mortality (p = 0.5), and incidences of perioperative stroke (p = 0.45), postoperative new-onset atrial fibrillation (p = 0.26) and permanent pacemaker implantation (p = 0.8) were similar in both groups. Early postoperative gradients were significantly lower in patients receiving Trifecta valves, although the long-term clinical outcome and durability of the valve will require further evaluation.
- 1 May 2014
- Vol. 23 (3) , 325-32
Early in-vivo hemodynamic comparison of supra-annular aortic bioprostheses: Trifecta versus Perimount Magna Ease.
The study aim was to compare early postoperative hemodynamic gradients after supra-annular implantation of the Trifecta and Perimount Magna Ease aortic bioprostheses. Between January 2010 and December 2011, a total of 235 patients (105 males, 130 females; mean age at surgery 73.8 +/- 10.2 years) underwent supra-annular aortic valve replacement (AVR), with or without concomitant procedures. The patients were divided into 2 groups receiving either the Perimount Magna Ease (n = 117) or Trifecta (n = 118). Concomitant procedures were performed in 133 patients (56.6%), and 25 procedures (10.6%) were redos. Patients with postoperative severe left ventricular dysfunction and moderate to severe mitral regurgitation were excluded. Gradients were calculated pre-discharge using transthoracic echocardiography. Effective orifice area calculations were not performed. Data were collected retrospectively from hospital databases and analyzed using SPSS 17. Both groups compared well for 14 variables. Group A had a higher number of redo operations and the patients were younger. Postoperative peak and mean gradients (in mmHg) for the Magna Ease group versus Trifecta group were: 19 mm valves, 33.5 +/- 16 versus 24.7 +/- 10 (p = 0.11) and 17.4 +/- 6.5 versus 12.7 +/- 4.4 (p = 0.05); 21 mm, 27.2 +/- 9.1 versus 21.8 +/- 7.2 (p = 0.001) and 13.8 +/- 4.7 versus 10.7 +/- 3.4 (p = 0.001); 23 mm, 25.6 +/- 7.8 versus 20.1 +/- 7.9 (p = 0.005) and 13 +/- 4 versus 10.1 +/- 4.3 (p = 0.002); 25 mm, 22.3 +/- 7.8 versus 15.6 +/- 5.1 (p = 0.01) and 12.8 +/- 4.1 versus 8 +/- 2.8 (p = 0.02). The overall mortality was 3.4%. The median hospital stay was nine days in both groups (p = 0.13). Mortality (p = 0.5), and incidences of perioperative stroke (p = 0.45), postoperative new-onset atrial fibrillation (p = 0.26) and permanent pacemaker implantation (p = 0.8) were similar in both groups. Early postoperative gradients were significantly lower in patients receiving Trifecta valves, although the long-term clinical outcome and durability of the valve will require further evaluation.
- 1 February 2010
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 18 (1) , 17-21
Hemodynamic Advantages of Right Heart Decompression during Off-Pump Surgery
Cardiac maneuvering during off-pump coronary artery bypass surgery can compress the right ventricle, causing temporary dysfunction and hemodynamic instability. The hemodynamic impact of a decompression technique comprising right pleurotomy and pericardial release was investigated during cardiac elevation. Intraoperative continuous real-time monitoring of cardiac index and stroke volume index was carried out using the PulseCO system in 12 consecutive patients with normal ventricular function who underwent off-pump coronary artery bypass by a single surgeon. A pulmonary artery catheter was used to monitor pulmonary artery pressure and systemic venous O2 saturation. Hemodynamic changes during vertical displacement of the heart were measured before and after performing a right pleurotomy and pericardial release. Following right heart decompression, stroke volume index, cardiac index, mean arterial pressure, and systemic venous O2 saturation were significantly better preserved during cardiac elevation. This demonstrates that right heart decompression via pleurotomy and pericardial release significantly improves hemodynamic stability during cardiac manipulation. We recommend the use of this procedure in off-pump coronary artery bypass when cardiac tilting is required.
- 1 February 2010
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 18 (1) , 17-21
Hemodynamic Advantages of Right Heart Decompression during Off-Pump Surgery
Cardiac maneuvering during off-pump coronary artery bypass surgery can compress the right ventricle, causing temporary dysfunction and hemodynamic instability. The hemodynamic impact of a decompression technique comprising right pleurotomy and pericardial release was investigated during cardiac elevation. Intraoperative continuous real-time monitoring of cardiac index and stroke volume index was carried out using the PulseCO system in 12 consecutive patients with normal ventricular function who underwent off-pump coronary artery bypass by a single surgeon. A pulmonary artery catheter was used to monitor pulmonary artery pressure and systemic venous O2 saturation. Hemodynamic changes during vertical displacement of the heart were measured before and after performing a right pleurotomy and pericardial release. Following right heart decompression, stroke volume index, cardiac index, mean arterial pressure, and systemic venous O2 saturation were significantly better preserved during cardiac elevation. This demonstrates that right heart decompression via pleurotomy and pericardial release significantly improves hemodynamic stability during cardiac manipulation. We recommend the use of this procedure in off-pump coronary artery bypass when cardiac tilting is required.
- 1 January 2010
- Vol. 37 (1) , 75-8
Myocardial protection during reoperative cardiac surgery: early experience with a new technique.
We recently introduced a new adjunct to myocardial preservation in patients with a patent left internal mammary artery graft who were undergoing reoperative cardiac surgery. The purpose of this study was to review our early experience with this technique.The technique consists of preoperative insertion of a suitably sized angioplasty balloon catheter into the proximal part of the graft under fluoroscopic guidance. Intraoperative inflation of the balloon results in occlusion of the graft during aortic cross-clamping. We have used this technique in 9 patients. The case records of these patients were retrospectively reviewed. There were 5 men and 4 women with a mean age of 71 +/- 11 years and a mean Euro-SCORE of 10 +/- 3. The median time interval from previous cardiac operation to reoperation was 6 years (interquartile range, 2-11 yr). After the balloon catheter was inserted successfully into the left internal mammary artery graft, the balloon was inflated intraoperatively for successful occlusion of the graft in all patients. There was no in-hospital death, and no significant complications were observed.The early results of this technique seem favorable. A prospective randomized study is needed in order to evaluate the potential advantages of this method over other techniques of myocardial protection during cardiac reoperations.
- 1 January 2010
- Vol. 37 (1) , 75-8
Myocardial protection during reoperative cardiac surgery: early experience with a new technique.
We recently introduced a new adjunct to myocardial preservation in patients with a patent left internal mammary artery graft who were undergoing reoperative cardiac surgery. The purpose of this study was to review our early experience with this technique.The technique consists of preoperative insertion of a suitably sized angioplasty balloon catheter into the proximal part of the graft under fluoroscopic guidance. Intraoperative inflation of the balloon results in occlusion of the graft during aortic cross-clamping. We have used this technique in 9 patients. The case records of these patients were retrospectively reviewed. There were 5 men and 4 women with a mean age of 71 +/- 11 years and a mean Euro-SCORE of 10 +/- 3. The median time interval from previous cardiac operation to reoperation was 6 years (interquartile range, 2-11 yr). After the balloon catheter was inserted successfully into the left internal mammary artery graft, the balloon was inflated intraoperatively for successful occlusion of the graft in all patients. There was no in-hospital death, and no significant complications were observed.The early results of this technique seem favorable. A prospective randomized study is needed in order to evaluate the potential advantages of this method over other techniques of myocardial protection during cardiac reoperations.
- Open Access
- 1 July 2009
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 36 (1) , 148-154
Thyroid function during coronary surgery with and without cardiopulmonary bypass☆
Objective: Cardiopulmonary bypass (CPB) is associated with thyroid hormone changes consistent with euthyroid sick syndrome. Similar changes have been observed after general surgical operations. Thyroid hormone changes and their association with global oxygen consumption were studied in low-risk patients undergoing coronary artery bypass grafting (CABG) with and without CPB. Methods: Fifty-two patients undergoing primary CABG by the same surgeon were randomised into either on-pump (ONCAB, n = 26) or off-pump (OPCAB, n = 26) groups. Thyroid-stimulating hormone (TSH), free thyroxine (fT4) and free triiodothyronine (fT3) levels were measured at sequential time-points using chemiluminescence assays. Global oxygen consumption was measured at sequential time-points using a continuous cardiac output Swan-Ganz catheter. Results: In both groups TSH and fT4 remained within normal range throughout the study. There was a similar and progressive decline in fT3 levels with no significant difference between the groups over time (p = 0.42). Mean fT3 levels at 24 h were below the normal range and significantly lower than baseline values (ONCAB, 3.3 ± 0.69 pmol/L vs 5.1 ± 0.41 pmol/L, p ≪ 0.001; OPCAB, 3.3 ± 0.51 pmol/L vs 5.0 ± 0.46 pmol/L, p ≪ 0.001). There was a significant inverse relationship between fT3 levels and global oxygen consumption. Conclusions: Off-pump surgery is associated with thyroid hormone changes similar to conventional surgical revascularisation. The data suggest that further studies into T3 administration during OPCAB may be warranted.
- 1 July 2009
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 36 (1) , 148-154
Open AccessThyroid function during coronary surgery with and without cardiopulmonary bypass☆
Objective: Cardiopulmonary bypass (CPB) is associated with thyroid hormone changes consistent with euthyroid sick syndrome. Similar changes have been observed after general surgical operations. Thyroid hormone changes and their association with global oxygen consumption were studied in low-risk patients undergoing coronary artery bypass grafting (CABG) with and without CPB. Methods: Fifty-two patients undergoing primary CABG by the same surgeon were randomised into either on-pump (ONCAB, n = 26) or off-pump (OPCAB, n = 26) groups. Thyroid-stimulating hormone (TSH), free thyroxine (fT4) and free triiodothyronine (fT3) levels were measured at sequential time-points using chemiluminescence assays. Global oxygen consumption was measured at sequential time-points using a continuous cardiac output Swan-Ganz catheter. Results: In both groups TSH and fT4 remained within normal range throughout the study. There was a similar and progressive decline in fT3 levels with no significant difference between the groups over time (p = 0.42). Mean fT3 levels at 24 h were below the normal range and significantly lower than baseline values (ONCAB, 3.3 ± 0.69 pmol/L vs 5.1 ± 0.41 pmol/L, p ≪ 0.001; OPCAB, 3.3 ± 0.51 pmol/L vs 5.0 ± 0.46 pmol/L, p ≪ 0.001). There was a significant inverse relationship between fT3 levels and global oxygen consumption. Conclusions: Off-pump surgery is associated with thyroid hormone changes similar to conventional surgical revascularisation. The data suggest that further studies into T3 administration during OPCAB may be warranted.