PAPierre-Jean Arnoux

Pierre-Jean Arnoux

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pierre-Jean Arnoux has a total of 20 co-authors. Here are the top co-authors by number of shared publications:

  • A. Garo

    Laboratoire de Biomécanique Appliquée – UMRT 24 , INRETS/Université de la Méditerranée , Marseille, France ; Département de Génie Mécanique , École Polytechnique , Montréal, Canada

    2 shared publications
  • Anaïs Garo

    Laboratoire de Biomécanique Appliquée-UMRT 24, INRETS/Université de la Méditerranée, Marseille, 13916, France

    2 shared publications
  • C. Brunet

    Laboratoire de Biomécanique Appliquée , UMRT 24 Faculté de Médecine-INRETS, Université de la Méditerranée , Marseille, France

    2 shared publications
  • C.E. Aubin

    Département de Génie Mécanique , École Polytechnique , Montréal, Canada

    2 shared publications
  • L. Thollon

    Laboratoire de Biomécanique Appliquée , UMRT 24 Faculté de Médecine-INRETS, Université de la Méditerranée , Marseille, France

    2 shared publications
  • M. Behr

    Laboratoire de Biomécanique Appliquée , UMRT 24 Faculté de Médecine-INRETS, Université de la Méditerranée , Marseille, France

    2 shared publications

Latest Publications

  • Petrous Bone Fracture

    by Marion Montava, Arnaud Deveze, Pierre-Jean Arnoux, Samuel Bidal, Christian Brunet, Jean-Pierre Lavieille

    Objective The temporal bone shields sensorineural, nervous, and vascular structures explaining the potential severity and complications of trauma related to road and sport accidents. So far, no clear data are available on the exact mechanisms involved for fracture processes. Modelization of structures helps to answer these concerns. Our objective was to design a finite element model of the petrous bone structure to modelize temporal bone fracture propagation in a scenario of lateral impact. Materials and Methods A finite element model of the petrous bone structure was designed based on computed tomography data. A 7-m/s lateral impact was simulated to reproduce a typical lateral trauma. Results of model analysis was based on force recorded, stress level on bone structure up to induce a solution of continuity of the bony structure. Results Model simulation showed that bone fractures follow the main axes of the petrous bone and occured in a 2-step process: first, a crush, and second, a massive fissuration of the petrous bone. The lines of fracture obtained by simulation of a lateral impact converge toward the middle ear region. This longitudinal fracture is located at the mastoid–petrous pyramid junction. Discussion Using this model, it was possible to map petrous bone fractures including fracture chronology and areas of fusion of the middle ear region. This technique may represent a first step to investigate the pathophysiology of the petrous bone fractures, aiming to define prognostic criteria for patients’ care.


  • Calibration of the mechanical properties in a finite element model of a lumbar vertebra under dynamic compression up to failure

    by Anaïs Garo, Pierre Jean Arnoux, Eric Wagnac, Carl Eric Aubin

    Finite element models (FEM) dedicated to vertebral fracture simulations rarely take into account the rate dependency of the bone material properties due to limited available data. This study aims to calibrate the mechanical properties of a vertebral body FEM using an inverse method based on experiments performed at slow and fast dynamic loading conditions. A detailed FEM of a human lumbar vertebral body (23,394 elements) was developed and tested under compression at 2,500 and 10 mm s−1. A central composite design was used to adjust the mechanical properties (Young modulus, yield stress, and yield strain) while optimizing four criteria (ultimate strain and stress of cortical and trabecular bone) until the failure load and energy at failure reached experimental results from the literature. At 2,500 mm s−1, results from the calibrated simulation were in good agreement with the average experimental data (1.5% difference for the failure load and 0.1% for the energy). At 10 mm s−1, they were in good agreement with the average experimental failure load (0.6% difference), and within one standard deviation of the reported range of energy to failure. The proposed method provides a relevant mean to identify the mechanical properties of the vertebral body in dynamic loadings.


    • 1 January 2010
      • Vol. 158, 167-71

    Biomechanical analysis of pedicle screw placement: a feasibility study.

    by Eric Wagnac, Denis Michardière, Anaïs Garo, Pierre-Jean Arnoux, Jean-Marc Mac-Thiong, Carl-Eric Aubin

    In spinal instrumentation surgery, the optimal placement of pedicle screws that takes into account the cortical/cancellous bone quality, geometry and property distribution, and screw design is still undetermined despite several in vitro experiments. The objective of this study was to evaluate the feasibility of using a detailed finite element model (FEM) of an instrumented vertebra to simulate screw axial pull-out and to analyze the bone-screw mechanical interaction. The FEM was built using CT-scan images of the L3 vertebra (0.6mm thick contiguous slices) of a 50th percentile human male volunteer, in order to virtually implant a fully customizable pedicle screw in a straight-forward position. The 753,000 elements model takes into account local cortical bone thickness and integrates advanced material behavior (elasto-plastic) laws that simulate bone failure. Screw axial pull-out was simulated and compared to in vitro experimental data, and the stress distribution at the screw thread-bone interface was analyzed. The simulated screw pull-out force (non-linear response with a failure at 640N) was within the range of experimental data (500-660N). Von Mises stresses in the bony structures were concentrated around the root of each internal thread, with the maximum stress located near the first proximal thread, in the cortical bone of the posterior wall of the pars. This study shows the feasibility and relevance of using a detailed FEM to simulate screw pull-out and to analyze the bone-screw mechanical interaction.


  • Estimation of bone material properties using an inverse finite element method

    by A. Garo, P.J. Arnoux, C.E. Aubin

    (2009). Estimation of bone material properties using an inverse finite element method. Computer Methods in Biomechanics and Biomedical Engineering: Vol. 12, 34th Congress of the Société de Bioméchanique, pp. 121-122.


  • Liver injuries in frontal crash situations a coupled numerical—experimental approach

    by P. J. Arnoux, T. Serre, N. Cheynel, L. Thollon, M. Behr, P. Baque, C. Brunet

    From clinical knowledge, it has been established that hepatic traumas frequently lead to lethal injuries. In frontal or lateral crash situations, these injuries can be induced by pure deceleration effects or blunt trauma due to belt or steering wheel impact. Concerning the liver under frontal decelerations, how could one investigate organ behaviour leading to the injury mechanisms? This work couples experimental organ decelerations measurements (with 19 tests on cadaver trunks) and finite element simulation, provides a first analysis of the liver behaviour within the abdomen. It shows the influence of the liver attachment system that leads to liver trauma and also torsion effects between the two lobes of the liver. Injury mechanisms were evaluated through the four phases of the liver kinematics under frontal impact: (1) postero-anterior translation, (2) compression and sagittal rotation, (3) rotation in the transverse plane and (4) relaxation.


  • Pedestrian Lower Limb Injury Criteria Evaluation: A Finite Element Approach

    by P. J. Arnoux, D. Cesari, M. Behr, L. Thollon, C. Brunet

    Objective. In pedestrian traumas, lower limb injuries occur under lateral shearing and bending at the knee joint level. One way to improve injury mechanisms description and consequently knee joint safety is to evaluate the ultimate shearing and bending levels at which ligaments start being injured. Methods. As such data cannot easily and accurately be recorded clinically or during experiments, we show in this article how numerical simulation can be used to estimate such thresholds. This work was performed with the Lower Limb Model for Safety (LLMS) in pure lateral bending and shearing conditions, with an extended range of impact velocities. Results. One result concerns the ultimate knee lateral bending angle and shearing displacement measurements for potential failure of ligaments (posterior cruciate, medial collateral, anterior cruciates and tibial collateral). They were evaluated to be close to 16° and 15 mm, respectively. Conclusion. The lower leg model used in this study is an advanced FE model of the lower limb, validated under various situations. Its accurate anatomical description allows a wide range of applications. According to the validity domain of the model, it offered a valuable tool for the numerical evaluation of potential injuries and the definition of injury risk criterion for knee joint.