Güzin Alpdoğan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Güzin Alpdoğan has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Şule Dinç Zor
Yildiz Technical University, Department of Chemistry , Davutpasa Campus , Istanbul 34220, Türkiye
3 shared publications - Aysegul Peksel
Department of Chemistry, Faculty of Arts and Science Yildiz Technical University Istanbul Türkiye
2 shared publications - Erdal Ertas
Climate and Life Sciences TUBITAK Marmara Research Center Kocaeli 41470 Turkey
2 shared publications - Oznur Karaoglu
The Scientific and Technological Research Council of Turkey - TUBITAK. - Yildiz Technical University, Chemistry Department
2 shared publications Sidika Sungur
Department of Chemistry , Yıldız Technical University, Davutpaşa Campus , İstanbul, Turkey
2 shared publicationsŞule Dinç Zor
Yildiz Technical University, Faculty of Arts and Sciences, Department of Chemistry, Davutpasa Campus, 34220 Esenler, Istanbul, Turkey
2 shared publications
Latest Publications
- Open Access
- 15 September 2020
- Published by Editorial CSIC in Grasas y Aceites
- Vol. 71 (3) , e370
Solid phase extraction of β-sitosterol and α-tocopherol from sunflower oil deodorizer distillate using desilicated zeolite
In this study, the efficiency of using zeolite-based adsorbents in a solid phase extraction (SPE) procedure of α-tocopherol and β-sitosterol isolation from Sunflower Oil Deodorizer Distillate (SuDOD) without pre-treatment was investigated. The results showed that 99.2% α-tocopherol and 97.3% β-sitosterol were successfully isolated as pure fractions from SuDOD, when desilicated ZSM-5-type zeolite (DSiZSM-5) was used as adsorbent on a SPE. A simple and rapid HPLC method for simultaneous α-tocopherol and β-sitosterol analysis was developed and validated according to AOAC guidelines. It was found that the inclusion of a DSiZSM-5 SPE step increased the precision of the α-tocopherol and β-sitosterol analysis. In conclusion, DSiZSM-5 zeolite was proven to be an efficient adsorbent which can be used not only for the recovery of α-tocopherol and β-sitosterol from SuDOD in industrial scale, but also in a laboratory scale clean-up method prior to the analysis of α-tocopherol and β-sitosterol.
- 15 September 2020
- Published by Editorial CSIC in Grasas y Aceites
- Vol. 71 (3) , e370
Open AccessSolid phase extraction of β-sitosterol and α-tocopherol from sunflower oil deodorizer distillate using desilicated zeolite
In this study, the efficiency of using zeolite-based adsorbents in a solid phase extraction (SPE) procedure of α-tocopherol and β-sitosterol isolation from Sunflower Oil Deodorizer Distillate (SuDOD) without pre-treatment was investigated. The results showed that 99.2% α-tocopherol and 97.3% β-sitosterol were successfully isolated as pure fractions from SuDOD, when desilicated ZSM-5-type zeolite (DSiZSM-5) was used as adsorbent on a SPE. A simple and rapid HPLC method for simultaneous α-tocopherol and β-sitosterol analysis was developed and validated according to AOAC guidelines. It was found that the inclusion of a DSiZSM-5 SPE step increased the precision of the α-tocopherol and β-sitosterol analysis. In conclusion, DSiZSM-5 zeolite was proven to be an efficient adsorbent which can be used not only for the recovery of α-tocopherol and β-sitosterol from SuDOD in industrial scale, but also in a laboratory scale clean-up method prior to the analysis of α-tocopherol and β-sitosterol.
- 1 June 2020
- Published by Wiley in Journal of the Science of Food and Agriculture
- Vol. 100 (13) , 4808-4817
Multivariate optimization of a new LC–MS/MS method for the determination of 156 pesticide residues in milk and dairy products
BACKGROUND: Pesticides are widely utilized worldwide to control undesirable life forms during the planting procedure in agriculture. But they can pollute the nature and jeopardize human wellbeing. Additionally, on account of high resistance and biological activity; pesticides are able to accumulate in living organs and lead to acute and long‐term negative effects along with toxicity. Milk and dairy products constitute an important part of a humans’ diet since they contain fundamental supplements and nutrients, however they may also be the source of unhealthy components including pesticides. Therefore efficient, accurate and sensitive determination methods must be improved to quantify pesticide residues in these food samples.RESULTS: Multivariate optimization strategy was employed to optimize an efficient and robust liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) method for the determination of 156 pesticide residues in milk and dairy products. Three independent variables considered and their levels in the Box–Behnken design were as follows: initial percentage of eluent A in mobile phase (30, 40, 50%), flow rate of the mobile phase (0.1, 0.2, 0.3 mL min−1), and ammonium formate concentration in mobile phase (0.0, 0.5, 1.0 mmol L−1). Under optimized conditions, average recoveries of target analytes were obtained in the range of 70.38% to 119.04%. Detection and quantification limits ranged from 0.06 to 2.70 μg kg−1 and from 0.22 to 8.10 μg kg−1, respectively.CONCLUSION: The validated method was successfully implemented to the analysis of 20 milk and dairy products including cream, cheese and yogurt. This method could be applied in many laboratories to reduce analysis time and cost. © 2020 Society of Chemical Industry
- 1 June 2020
- Published by Wiley in Journal of the Science of Food and Agriculture
- Vol. 100 (13) , 4808-4817
Multivariate optimization of a new LC–MS/MS method for the determination of 156 pesticide residues in milk and dairy products
BACKGROUND: Pesticides are widely utilized worldwide to control undesirable life forms during the planting procedure in agriculture. But they can pollute the nature and jeopardize human wellbeing. Additionally, on account of high resistance and biological activity; pesticides are able to accumulate in living organs and lead to acute and long‐term negative effects along with toxicity. Milk and dairy products constitute an important part of a humans’ diet since they contain fundamental supplements and nutrients, however they may also be the source of unhealthy components including pesticides. Therefore efficient, accurate and sensitive determination methods must be improved to quantify pesticide residues in these food samples.RESULTS: Multivariate optimization strategy was employed to optimize an efficient and robust liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) method for the determination of 156 pesticide residues in milk and dairy products. Three independent variables considered and their levels in the Box–Behnken design were as follows: initial percentage of eluent A in mobile phase (30, 40, 50%), flow rate of the mobile phase (0.1, 0.2, 0.3 mL min−1), and ammonium formate concentration in mobile phase (0.0, 0.5, 1.0 mmol L−1). Under optimized conditions, average recoveries of target analytes were obtained in the range of 70.38% to 119.04%. Detection and quantification limits ranged from 0.06 to 2.70 μg kg−1 and from 0.22 to 8.10 μg kg−1, respectively.CONCLUSION: The validated method was successfully implemented to the analysis of 20 milk and dairy products including cream, cheese and yogurt. This method could be applied in many laboratories to reduce analysis time and cost. © 2020 Society of Chemical Industry
- 1 May 2020
- Published by Elsevier in Food Chemistry
- Vol. 311, 125890
Efficient solid phase extraction of α-tocopherol and β-sitosterol from sunflower oil waste by improving the mesoporosity of the zeolitic adsorbent
- 1 May 2020
- Published by Elsevier in Food Chemistry
- Vol. 311, 125890
Efficient solid phase extraction of α-tocopherol and β-sitosterol from sunflower oil waste by improving the mesoporosity of the zeolitic adsorbent
- Open Access
- 11 September 2017
- Published by The Turkish Chemical Society in Journal of the Turkish Chemical Society Section A: Chemistry
- Vol. 4 (3) , 915-930
Optimization of Ultrasound-Assisted Extraction of Antioxidants from Apium graveolens L. Seeds using Response Surface Methodology
In this study, optimum conditions for ultrasound-assisted extraction (UAE) of antioxidants from Apium graveolens L. seeds were investigated by Response Surface Methodology (RSM). A Box-Behnken Design (BBD) was used to evaluate the effect of sonication time (5, 10, 15 min), ultrasound power (60, 120, 180 W) and the ratio of extraction solvent in terms of methanol (0, 50, 100%) on antioxidant capacity. The optimal UAE conditions for the parameters investigated were 11 min of sonication time, ultrasound power of 131 W and 100% methanol as an extraction solvent. Under these conditions, UAE of antioxidants from the seeds achieved a maximum of 95.08% in respect to 1,1-diphenyl-2-picryl hydrazyl (DPPH) radical scavenging activity. Additionally, the high value of the adjusted coefficient of determination (R2adj = 0.9192) and the non-significant difference between experimental and predicted values confirmed the validity of the quadratic polynomial model. Hence, UAE is a suitable, fast, economical and practical technique for the extraction of antioxidants from Apium graveolens L. seeds.
- 11 September 2017
- Published by The Turkish Chemical Society in Journal of the Turkish Chemical Society Section A: Chemistry
- Vol. 4 (3) , 915-930
Open AccessOptimization of Ultrasound-Assisted Extraction of Antioxidants from Apium graveolens L. Seeds using Response Surface Methodology
In this study, optimum conditions for ultrasound-assisted extraction (UAE) of antioxidants from Apium graveolens L. seeds were investigated by Response Surface Methodology (RSM). A Box-Behnken Design (BBD) was used to evaluate the effect of sonication time (5, 10, 15 min), ultrasound power (60, 120, 180 W) and the ratio of extraction solvent in terms of methanol (0, 50, 100%) on antioxidant capacity. The optimal UAE conditions for the parameters investigated were 11 min of sonication time, ultrasound power of 131 W and 100% methanol as an extraction solvent. Under these conditions, UAE of antioxidants from the seeds achieved a maximum of 95.08% in respect to 1,1-diphenyl-2-picryl hydrazyl (DPPH) radical scavenging activity. Additionally, the high value of the adjusted coefficient of determination (R2adj = 0.9192) and the non-significant difference between experimental and predicted values confirmed the validity of the quadratic polynomial model. Hence, UAE is a suitable, fast, economical and practical technique for the extraction of antioxidants from Apium graveolens L. seeds.
- 1 September 2017
- Published by Oxford University Press (OUP)
- Vol. 100 (5) , 1524-1530
A New Dispersive Liquid–Liquid Microextraction Method for Preconcentration and Determination of Aluminum, Iron, Copper, and Lead in Real Water Samples by HPLC
In this study, dispersive liquid–liquid microextraction coupled with HPLC with variable-wavelength detection was applied for the simultaneous determination of Al, Fe, Cu, and Pb in various water samples at trace levels. In the proposed method, all the system parameters in both the extraction and separation/determination steps, such as extraction and disperser solvent type and their volumes, complexing reagent concentration, salt addition, extraction and centrifugation times, and pH, were optimized to get not only high extraction efficiency but also lower LODs for the analytes. Hematoxylin was used as a complexing reagent, and carbon tetrachloride and methanol were chosen as the extraction and disperser solvents, respectively. Metal complexes were separated with a reversed-phase C18 column by isocratic elution, with methanol–tetrahydrofuran–water (20 + 12 + 68, v/v/v) as the mobile phase at a flow rate of 1.0 mL/min and detection at 575 nm. The accuracy of the method was checked by a Standard ReferenceMaterial of water (SRM 1643e), and the recovery values for the analytes were found in the range of 95.6–101.3%. Under the optimum conditions, the developed method was applied to tap water, bottled mineral water, lake water, and seawater for the accurateand sensitive determination of the analytes of interest.
- 1 September 2017
- Published by Oxford University Press (OUP)
- Vol. 100 (5) , 1524-1530
A New Dispersive Liquid–Liquid Microextraction Method for Preconcentration and Determination of Aluminum, Iron, Copper, and Lead in Real Water Samples by HPLC
In this study, dispersive liquid–liquid microextraction coupled with HPLC with variable-wavelength detection was applied for the simultaneous determination of Al, Fe, Cu, and Pb in various water samples at trace levels. In the proposed method, all the system parameters in both the extraction and separation/determination steps, such as extraction and disperser solvent type and their volumes, complexing reagent concentration, salt addition, extraction and centrifugation times, and pH, were optimized to get not only high extraction efficiency but also lower LODs for the analytes. Hematoxylin was used as a complexing reagent, and carbon tetrachloride and methanol were chosen as the extraction and disperser solvents, respectively. Metal complexes were separated with a reversed-phase C18 column by isocratic elution, with methanol–tetrahydrofuran–water (20 + 12 + 68, v/v/v) as the mobile phase at a flow rate of 1.0 mL/min and detection at 575 nm. The accuracy of the method was checked by a Standard ReferenceMaterial of water (SRM 1643e), and the recovery values for the analytes were found in the range of 95.6–101.3%. Under the optimum conditions, the developed method was applied to tap water, bottled mineral water, lake water, and seawater for the accurateand sensitive determination of the analytes of interest.
- Open Access
- 23 November 2016
- Published by Wiley in Journal of Chemistry
- Vol. 2016, 1-8
Analysis of Some Trace Metals in Fish Species after Preconcentration with Congo Red on Amberlite XAD-7 Resin by Flame Atomic Absorption Spectrometry
A new procedure for separation and preconcentration of trace amounts of Cu(II), Ni(II), Fe(III), Zn(II), Cr(III), Cd(II), and Pb(II) in fish samples was proposed. The procedure is based on the adsorption of these metal ions on the column of Amberlite XAD-7 as congo red complexes prior to their determination by flame atomic absorption spectrometry (FAAS). Several factors that can affect the sorption and elution efficiency of the metal ions were investigated and optimized. The sorption was quantitative in the pH range of 6.0–9.0 for Cu(II) and Ni(II), 5.5–8.0 for Fe(III), 6.0–8.5 for Zn(II) and Cd(II), and 7.0–8.5 for Cr(III) and Pb(II). The optimum pH for simultaneous retention was 7.5. The sorption capacity of the resin was found to be 0.89, 0.72, 0.82, 0.61, 0.53, 0.84, and 0.78 mg/g for Cu(II), Ni(II), Fe(III), Zn(II), Cr(III), Cd(II), and Pb(II), respectively. The precision of the method was evaluated as the relative standard deviation obtained by analyzing a series of six replicates and below 6% for all seven elements. The validation of the method was performed by the analysis of certified reference materials. The proposed method was successfully applied to separation/preconcentration and determination of these metals in fish samples.
- 23 November 2016
- Published by Wiley in Journal of Chemistry
- Vol. 2016, 1-8
Open AccessAnalysis of Some Trace Metals in Fish Species after Preconcentration with Congo Red on Amberlite XAD-7 Resin by Flame Atomic Absorption Spectrometry
A new procedure for separation and preconcentration of trace amounts of Cu(II), Ni(II), Fe(III), Zn(II), Cr(III), Cd(II), and Pb(II) in fish samples was proposed. The procedure is based on the adsorption of these metal ions on the column of Amberlite XAD-7 as congo red complexes prior to their determination by flame atomic absorption spectrometry (FAAS). Several factors that can affect the sorption and elution efficiency of the metal ions were investigated and optimized. The sorption was quantitative in the pH range of 6.0–9.0 for Cu(II) and Ni(II), 5.5–8.0 for Fe(III), 6.0–8.5 for Zn(II) and Cd(II), and 7.0–8.5 for Cr(III) and Pb(II). The optimum pH for simultaneous retention was 7.5. The sorption capacity of the resin was found to be 0.89, 0.72, 0.82, 0.61, 0.53, 0.84, and 0.78 mg/g for Cu(II), Ni(II), Fe(III), Zn(II), Cr(III), Cd(II), and Pb(II), respectively. The precision of the method was evaluated as the relative standard deviation obtained by analyzing a series of six replicates and below 6% for all seven elements. The validation of the method was performed by the analysis of certified reference materials. The proposed method was successfully applied to separation/preconcentration and determination of these metals in fish samples.
- 27 October 2016
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 12 (6) , 642-650
Analysis of Some Trace Metals in Milk Samples by FAAS After Preconcentration by Aspergillus niger Loaded on TiO2 Nanoparticles
A sensitive, accurate and simple method for the simultaneous preconcentration of Cu(II), Ni(II), Cd(II), Mn(II), Cr(III) and Pb(II) in milk samples has been reported in this study. Target metal ions were determined by flame atomic absorption spectrometry (FAAS) after preconcentration on Aspergillus niger (A. niger) loaded on TiO2 nanoparticles. The dead biomass of A. niger was first loaded on TiO2 nanoparticles and bioadsorbent obtained was characterized by SEM. The effect of pH, amount of bioadsorbent, elution conditions, maximum sample volume and flow rate on the recovery of trace metal ions studied were investigated. Trace metals were quantitatively sorbed on the bioadsorbent at pH 6.0, at a flow rate of 3.0 mL min-1 and subsequently eluted from the mini column with 2.0 mL of 0.5 mol L-1 HNO3. The preconcentration factor of the proposed method was 600. Detection limits (3s) of the method were 0.21 µg L-1 for Cu(II), 0.34 µg L-1 for Ni(II), 0.18 µg L-1 for Cd(II), 0.08 µg L-1 for Mn(II), 0.53 g L-1 for Cr(III) and for 0.61 µg L-1 Pb(II). Relative standard deviations (RSDs) of the method are lower than 3% indicating that the precision of method is very good. The accuracy was evaluated by means of the analysis of the standard reference material (NIST SRM 8435, whole milk powder). Finally, the developed preconcentration method was applied to the quantification of Cu(II), Ni(II), Cd(II), Mn(II), Cr(III) and Pb(II) in different milk samples by FAAS.
- 27 October 2016
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 12 (6) , 642-650
Analysis of Some Trace Metals in Milk Samples by FAAS After Preconcentration by Aspergillus niger Loaded on TiO2 Nanoparticles
A sensitive, accurate and simple method for the simultaneous preconcentration of Cu(II), Ni(II), Cd(II), Mn(II), Cr(III) and Pb(II) in milk samples has been reported in this study. Target metal ions were determined by flame atomic absorption spectrometry (FAAS) after preconcentration on Aspergillus niger (A. niger) loaded on TiO2 nanoparticles. The dead biomass of A. niger was first loaded on TiO2 nanoparticles and bioadsorbent obtained was characterized by SEM. The effect of pH, amount of bioadsorbent, elution conditions, maximum sample volume and flow rate on the recovery of trace metal ions studied were investigated. Trace metals were quantitatively sorbed on the bioadsorbent at pH 6.0, at a flow rate of 3.0 mL min-1 and subsequently eluted from the mini column with 2.0 mL of 0.5 mol L-1 HNO3. The preconcentration factor of the proposed method was 600. Detection limits (3s) of the method were 0.21 µg L-1 for Cu(II), 0.34 µg L-1 for Ni(II), 0.18 µg L-1 for Cd(II), 0.08 µg L-1 for Mn(II), 0.53 g L-1 for Cr(III) and for 0.61 µg L-1 Pb(II). Relative standard deviations (RSDs) of the method are lower than 3% indicating that the precision of method is very good. The accuracy was evaluated by means of the analysis of the standard reference material (NIST SRM 8435, whole milk powder). Finally, the developed preconcentration method was applied to the quantification of Cu(II), Ni(II), Cd(II), Mn(II), Cr(III) and Pb(II) in different milk samples by FAAS.
- 27 November 2015
- Published by Taylor & Francis in Toxicological & Environmental Chemistry
- Vol. 98 (2) , 179-188
Solid phase extraction of Cu (II), Ni (II), Co (II), and Fe (III) ions in water samples using salicylaldehyde benzoylhydrazone on Amberlite XAD-4 and their determinations by flame atomic absorption spectrometry
A multi element preconcentration procedure for solid phase extraction on Amberlite XAD-4 as their salicylaldehyde benzoylhydrazone chelates and flame atomic absorption spectrometric determination of some trace metal ions in water samples are proposed in this work. The influences of some analytical parameters, including pH of aqueous solution, amounts of reagent, flow rates of sample and eluent solutions, and sample volume on the quantitative recoveries of copper, nickel, cobalt, and iron were investigated. The effects of concomitant ions on the retentions of the analytes were also examined. The developed method has been successfully applied to the determination of metal ions in some real samples, including, tap water, river water, spring water, and waste water.
- 27 November 2015
- Published by Taylor & Francis in Toxicological & Environmental Chemistry
- Vol. 98 (2) , 179-188
Solid phase extraction of Cu (II), Ni (II), Co (II), and Fe (III) ions in water samples using salicylaldehyde benzoylhydrazone on Amberlite XAD-4 and their determinations by flame atomic absorption spectrometry
A multi element preconcentration procedure for solid phase extraction on Amberlite XAD-4 as their salicylaldehyde benzoylhydrazone chelates and flame atomic absorption spectrometric determination of some trace metal ions in water samples are proposed in this work. The influences of some analytical parameters, including pH of aqueous solution, amounts of reagent, flow rates of sample and eluent solutions, and sample volume on the quantitative recoveries of copper, nickel, cobalt, and iron were investigated. The effects of concomitant ions on the retentions of the analytes were also examined. The developed method has been successfully applied to the determination of metal ions in some real samples, including, tap water, river water, spring water, and waste water.
- 28 September 2010
- Published by Taylor & Francis in Analytical Letters
- Vol. 43 (15) , 2331-2339
Preparation and Metal Sorption Properties of GMA-MMA-DVB Microspheres Functionalized with 2-Aminothiazole
Crosslinked glycidylmethacrylate-methylmethacrylate-divinylbenzen (GMA-MMA-DVB) microspheres were prepared by suspension polymerization. The GMA-MMA-DVB microspheres with an average size of 150–300 μm and surface area of 1.51 m2g−1 were functionalized with 2-aminothiazole (ATAL). The affinity of the functionalized microspheres for copper, iron, aluminum, lead, cobalt, and nickel ions was examined. The effects of pH, resin amount, shaking time, type, and volume of the elution solution on the sorption and desorption properties of functionalized microspheres for these metal ions were investigated using the batch method. Sorption capacities (0.97–1.12 mmolg−1), quantitation limits (2.6–3.0 ppb) and recoveries (90–99%) were calculated.
- 28 September 2010
- Published by Taylor & Francis in Analytical Letters
- Vol. 43 (15) , 2331-2339
Preparation and Metal Sorption Properties of GMA-MMA-DVB Microspheres Functionalized with 2-Aminothiazole
Crosslinked glycidylmethacrylate-methylmethacrylate-divinylbenzen (GMA-MMA-DVB) microspheres were prepared by suspension polymerization. The GMA-MMA-DVB microspheres with an average size of 150–300 μm and surface area of 1.51 m2g−1 were functionalized with 2-aminothiazole (ATAL). The affinity of the functionalized microspheres for copper, iron, aluminum, lead, cobalt, and nickel ions was examined. The effects of pH, resin amount, shaking time, type, and volume of the elution solution on the sorption and desorption properties of functionalized microspheres for these metal ions were investigated using the batch method. Sorption capacities (0.97–1.12 mmolg−1), quantitation limits (2.6–3.0 ppb) and recoveries (90–99%) were calculated.