MPMaria Cristina Porciani

Maria Cristina Porciani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Maria Cristina Porciani has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 December 2006
      • Vol. 54  (6) , 735-41

    Is implantable defibrillator indicated in all patients on cardiac resynchronization therapy?

    by P Pieragnoli, G Ricciardi, A Colella, N Musilli, M C Porciani, M Giaccardi, L Padeletti, A Michelucci

    Implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) have been introduced during the recent years to improve survival, decrease hospital readmissions and mortality, and to improve functional status and quality of life for patients with heart failure and left ventricular systolic dysfunction (LVSD). Studies which evaluated the use of CRT or ICD alone or compared CRT with CRT-ICD in patients with heart failure and LVSD are listed in this article. The results obtained are already influencing clinical practice in the US, where it has been estimated that 90% of patients receiving a CRT device now are being implanted with an ICD component. However, it is still today debated whether patients with LVSD and heart failure should be routinely offered a CRT-ICD. In fact, there are some issues that still should be solved before to establish indication for CRT-D in all heart failure patients with an indication for CRT: 1) a non complete agreement among the different societies which wrote recommendations for guidelines (a comparative table is reported); 2) a better identification of implantable patients and an amelioration of utilized devices; 3) economic and ethical ramifications of this therapy. Anyway still now the crucial question is: ''Can resynchronization be done in isolation or must be accompanied by an ICD device?''. To answer to this question we can only express which is, in our opinion, the actual position of many physicians who work in the field of pacing and electrophysiology: ''The lesson to be learned is that we still can not predict surely which patient will die of sudden death. Until a method of identifying the high risk patients can be developed, the safest strategy should be to advise a combined ICD-CRT device for patients with indication for CRT''.

  • A Perspective on Atrioventricular Delay Optimization in Patients with a Dual Chamber Pacemaker

    by Maria Cristina Porciani, Giorgio Corbucci, Fabio Fantini, Nicola Musilli, Alessandra Sabini, Antionio Michelucci, Andrea Colella, Paolo Pieragnoli, Gabriele Demarchi, Luigi Padeletti


  • Diastolic subclinical primary alterations in marfan syndrome and marfan‐related disorders

    by Maria Cristina Porciani, Letizia Giurlani, Andrea Chelucci, Guglielmina Pepe, Betti Giusti, Tamara Brunelli, Monica Attanasio, Pietro Martinucci, Rossella Fattori, Rosanna Abbatea, et al.

    Background: The extracellular matrix tissue of the myocardium importantly contributes to left ventricular (LV) performance. Inherited connective tissue disorders related to the FBN1 gene could involve cardiac interstitium resulting in functional abnormalities.Hypothesis: To disclose a primary involvement of myocardium, LV function was studied in 28 patients affected by Marfan syndrome or Marfan‐related disorders: 20 Marfan and 8 MASS (Mitral valve prolapse, Myopia, Aortic dilatation, Skeletal involvement, Skin striae) and in 28 healthy, age and gender‐matched controls. No valvular regurgitation or any other cardiac alterations were present.Methods: Echocardiographic study was performed to investigate LV systolic and diastolic function.Results: No statistically significant differences were observed between patients and the control group in LV dimensions, systolic function parameters (ejection and shortening fraction), and some diastolic function parameters (E peak, A peak, E/A), while statistically significant differences were found between patients and the control group in LV mass (128.7 ± 46.6 vs. 83.7 ± 14.5 g/m2, p < 0.008), in isovolumic relaxation time (102.0 ± 24.0 vs. 80.1 ± 11.2 ms, pConclusions: These data show an unusual pattern of transmitral diastolic flow in which a decreased ventricular compliance and reduced myocardial relaxation coexist. Thus, in Marfan syndrome and in Marfan‐related disorders, subclinical diastolic alterations are present independent of valvular disease and might represent an early marker of primary myocardial involvement.


  • Open Access

    Interatrial septum pacing avoids the adverse effect of interatrial delay in biventricular pacing: an echo-Doppler evaluation

    by Maria Cristina Porciani, Alessandra Sabini, Andrea Colella, Antonio Michelucci, Nicola Musilli, Paolo Pieragnoli, Luigi Padeletti

    Aims. Biventricular pacing (BVP) can improve haemodynamics in patients with dilated cardiomyopathy (DCM) and left bundle branch block by reducing inter


  • Open Access

    Activities of day-life (ADL) protocol: Evaluation of dual sensor pacemaker and optimization by simulation

    by P. Pieragnoli, M.C. Porciani, A. Colella, A. Michelucci, F. Ferri, L. Pavia, G. Ranaldi, A. Stephan, L. Padeletti

    P. Pieragnoli, M.C. Porciani, A. Colella, A. Michelucci, F. Ferri, L. Pavia, G. Ranaldi, A. Stephan, L. Padeletti; Activities of day-life (ADL) protocol: Evalu

  • Open Access

    Dual chamber pacing: Optimization of AV delay with indexes of myocardial performance

    by M.C. Porciani, L. Padeletti, A. Colella, P. Pieragnoli, A. Michelucci, E. Manfredini, G. Corbucci

    M.C. Porciani, L. Padeletti, A. Colella, P. Pieragnoli, A. Michelucci, E. Manfredini, G. Corbucci; Dual chamber pacing: Optimization of AV delay with indexes o

  • Open Access

    Mode-switch testing in pacemakers implanted in patients

    by M. Mantica, M. Gasparini, A. Proclemer, S. Tognarini, F. Coltorti, G. Corbucci, R. Sutton, M.C. Porciani, P. Pieragnoli, A. Colella, et al.

    M. Mantica, M. Gasparini, A. Proclemer, S. Tognarini, F. Coltorti, G. Corbucci, R. Sutton, M.C. Porciani, P. Pieragnoli, A. Colella, A. Michelucci, L. Padeletti

  • Prevention of Short Term Reversible Chronic Atrial Fibrillation by Permanent Pacing at the Triangle of Koch

    by Luigi Padeletti, Maria Cristina Porciani, Antonio Michelucci, Andrea Colella, Alessandro Costoli, Cristina Ciapetti, Paolo Pieragnoli, Nicola Musilli, Gian Franco Gensini

    Objectives:The purpose of this study was to investigate if single lead interatrial septum pacing could be effective in maintaining sinus rhythm in patients in whom restoration of sinus rhythm was...


  • Atrioventricular Interval Optimization in the Right Atrial Appendage and Interatrial Septum Pacing: A Comparison Between Echo and Peak Endocardial Acceleration Measurements

    by Luigi Padeletti, Maria Cristina Porciani, Philippe Ritter, Antonio Michelucci, Andrea Colella, Paolo Pieragnoli, Alessandro Costoli, Cristina Ciapetti, Alessandra Sabini, Gabriele Demarchi, et al.

    PADELETTI, et al.: Atrioventricular Interval Optimization in the Right Atrial Appendage and Interatrial Septum Pacing: A Comparison Between ECHC and Peak Endocardial Acceleration. Interatrial septum pacing (IASP) reduces interatrial conduction time and consequently may interfere with atrioventricular delay (AVD) optimization. We studied 14 patients with an implanted BEST Living system device able to measure peak endocardial acceleration (PEA) signal. The aims of our study were to compare the (1) optimal AVD (OAVD) in right atrial appendage pacing (RAAP) and IASP, and (2) OAVD derived by the PEA signal versus OAVD derived by Echo/Doppler evaluation of the left ventricular filling time (LVFT) and cardiac output (CO). Measurements were performed in DDD VDD modes Eight patients (group A) had RAAP and six patients (group B) had IASP. In group A, OAVD measured by LVFT, CO, and PEA was 185 ± 23 ms, 177 ± 19 ms, and 192 ± 23 ms in DDD and 147 ± 19 ms, 135 ± 27 ms, and 146 ± 20 ms in VDD, respectively. OAVD measured by LVFT, CO, and PEA was significantly longer in DDD mode than in VDD (P < 0.01, P < 0.01, P < 0.001). In group B, OAVD measured by LVFT, CO, and PEA was 116 ± 19 ms, 113 ± 10 ms, and 130 ± 30ms in DDD and 106 ± 16 ms, 96 ± 15 ms, and 108 ± 26 ms in VDD, respectively. No statistical differences were observed between DDD and VDD. Significant correlations between OAVDs PEA derived and OAVDs LVFT and CO derived were observed (r = 0.71, r = 0.69, respectively). When new techniques of atrial stimulation, as IASP, are used an OAVD shorter and similar in VDD and DDD has to be considered. The BEST Living system could provide a valid method to ensure, in every moment, the exact required OAVD to maximize atrial contribution to CO.


    • 1 December 1999
      • Vol. 47  (12) , 544

    [Marfan's syndrome. Clinical and molecular characterization of 51 Italian patients].

    by L Giurlani, G Pepe, B Giusti, M Attanasio, P Comeglio, M C Porciani, L Evangelisti, T Brunelli, L Lucarini, R Abbate