Kyung Ki Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kyung Ki Kim has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Amrita Rana
5 shared publicationsAkshay Kumar Sharma
2 shared publications- Jeong-Tak Ryu
Daegu University
2 shared publications - Amrita Rana
Department of Electronic Engineering, Daegu University, Daegudaero 201, Gyeongsan 38543, Republic of Korea
1 shared publication H.C. Kim
1 shared publication- HeungJun Jeon
Samsung Electronics Co., Ltd., Gyeonggi-do 16677, Korea
1 shared publication
Latest Publications
- Open Access
Electrocardiography Classification with Leaky Integrate-and-Fire Neurons in an Artificial Neural Network-Inspired Spiking Neural Network Framework
Monitoring heart conditions through electrocardiography (ECG) has been the cornerstone of identifying cardiac irregularities. Cardiologists often rely on a detailed analysis of ECG recordings to pinpoint deviations that are indicative of heart anomalies. This traditional method, while effective, demands significant expertise and is susceptible to inaccuracies due to its manual nature. In the realm of computational analysis, Artificial Neural Networks (ANNs) have gained prominence across various domains, which can be attributed to their superior analytical capabilities. Conversely, Spiking Neural Networks (SNNs), which mimic the neural activity of the brain more closely through impulse-based processing, have not seen widespread adoption. The challenge lies primarily in the complexity of their training methodologies. Despite this, SNNs offer a promising avenue for energy-efficient computational models capable of displaying a high-level performance. This paper introduces an innovative approach employing SNNs augmented with an attention mechanism to enhance feature recognition in ECG signals. By leveraging the inherent efficiency of SNNs, coupled with the precision of attention modules, this model aims to refine the analysis of cardiac signals. The novel aspect of our methodology involves adapting the learned parameters from ANNs to SNNs using leaky integrate-and-fire (LIF) neurons. This transfer learning strategy not only capitalizes on the strengths of both neural network models but also addresses the training challenges associated with SNNs. The proposed method is evaluated through extensive experiments on two publicly available benchmark ECG datasets. The results show that our model achieves an overall accuracy of 93.8% on the MIT-BIH Arrhythmia dataset and 85.8% on the 2017 PhysioNet Challenge dataset. This advancement underscores the potential of SNNs in the field of medical diagnostics, offering a path towards more accurate, efficient, and less resource-intensive analyses of heart diseases.
Open AccessElectrocardiography Classification with Leaky Integrate-and-Fire Neurons in an Artificial Neural Network-Inspired Spiking Neural Network Framework
Monitoring heart conditions through electrocardiography (ECG) has been the cornerstone of identifying cardiac irregularities. Cardiologists often rely on a detailed analysis of ECG recordings to pinpoint deviations that are indicative of heart anomalies. This traditional method, while effective, demands significant expertise and is susceptible to inaccuracies due to its manual nature. In the realm of computational analysis, Artificial Neural Networks (ANNs) have gained prominence across various domains, which can be attributed to their superior analytical capabilities. Conversely, Spiking Neural Networks (SNNs), which mimic the neural activity of the brain more closely through impulse-based processing, have not seen widespread adoption. The challenge lies primarily in the complexity of their training methodologies. Despite this, SNNs offer a promising avenue for energy-efficient computational models capable of displaying a high-level performance. This paper introduces an innovative approach employing SNNs augmented with an attention mechanism to enhance feature recognition in ECG signals. By leveraging the inherent efficiency of SNNs, coupled with the precision of attention modules, this model aims to refine the analysis of cardiac signals. The novel aspect of our methodology involves adapting the learned parameters from ANNs to SNNs using leaky integrate-and-fire (LIF) neurons. This transfer learning strategy not only capitalizes on the strengths of both neural network models but also addresses the training challenges associated with SNNs. The proposed method is evaluated through extensive experiments on two publicly available benchmark ECG datasets. The results show that our model achieves an overall accuracy of 93.8% on the MIT-BIH Arrhythmia dataset and 85.8% on the 2017 PhysioNet Challenge dataset. This advancement underscores the potential of SNNs in the field of medical diagnostics, offering a path towards more accurate, efficient, and less resource-intensive analyses of heart diseases.
- Open Access
- 31 May 2023
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 32 (3) , 164-168
Development of a Weather Prediction Device Using Transformer Models and IoT Techniques
- 31 May 2023
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 32 (3) , 164-168
Open AccessDevelopment of a Weather Prediction Device Using Transformer Models and IoT Techniques
- Open Access
- 31 January 2022
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 31 (1) , 16-23
FPGA Implementation of an Artificial Intelligence Signal Recognition System
- 31 January 2022
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 31 (1) , 16-23
Open AccessFPGA Implementation of an Artificial Intelligence Signal Recognition System
- Open Access
- 30 September 2021
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 30 (5) , 286-289
Lightweight image classifier for CIFAR-10
- 30 September 2021
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 30 (5) , 286-289
Open AccessLightweight image classifier for CIFAR-10
- Open Access
- 30 September 2021
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 30 (5) , 290-294
Robust architecture search using network adaptation
- 30 September 2021
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 30 (5) , 290-294
Open AccessRobust architecture search using network adaptation
- Open Access
- 31 January 2021
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 30 (1) , 15-19
Lightweight CNN based Meter Digit Recognition
- 31 January 2021
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 30 (1) , 15-19
Open AccessLightweight CNN based Meter Digit Recognition
- Open Access
- 31 January 2021
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 30 (1) , 20-24
A Novel Spiking Neural Network for ECG signal Classification
- 31 January 2021
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 30 (1) , 20-24
Open AccessA Novel Spiking Neural Network for ECG signal Classification
- Open Access
- 31 January 2020
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 29 (1) , 68-73
Low Power Neuromorphic Hardware Design and Implementation Based on Asynchronous Design Methodology
- 31 January 2020
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 29 (1) , 68-73
Open AccessLow Power Neuromorphic Hardware Design and Implementation Based on Asynchronous Design Methodology
- Open Access
- 31 January 2020
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 29 (1) , 19-26
Comparison of Artificial Neural Networks for Low-Power ECG-Classification System
- 31 January 2020
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 29 (1) , 19-26
Open AccessComparison of Artificial Neural Networks for Low-Power ECG-Classification System
- Open Access
Fully Integrated on-Chip Switched DC–DC Converter for Battery-Powered Mixed-Signal SoCs
This paper presents a fully integrated on-chip switched-capacitor (SC) DC–DC converter that supports a programmable regulated power supply ranging from 2.6 to 3.2 V out of a 5 V input supply. The proposed 4-to-3 step-down topology utilizes two conventional 2-to-1 step-down topologies; each of them (2-to-1_up and 2-to-1_dw) has a different flying capacitance to maximize the load current driving capability while minimizing the bottom-plate capacitance loss. The control circuits use a low power supply provided by a small internal low-drop output (LDO) connected to the internal load voltage (VL_dw) from the 2-to-1_dw, and low swing level-shifted gate-driving signals are generated using the internal load voltage (VL_dw). Therefore, the proposed implementation reduces control circuit and switching power consumptions. The programmable power supply voltage is regulated by means of a pulse frequency modulation (PFM) technique with the compensated two-stage operational transconductance amplifier (OTA) and the current-starved voltage controlled oscillator (VCO) to maintain high efficiency over a wide range of load currents. The proposed on-chip SC DC–DC converter is designed and simulated using high-voltage 0.35 μm bipolar, complementary metal-oxide-semiconductor (CMOS) and DMOS (BCDMOS) technology. It achieves a peak efficiency of 74% when delivering an 8 mA load current at a 3.2 V supply voltage level, and it provides a maximum output power of 48 mW (IL = 15 mA at VL_up = 3.2 V) at 70.5% efficiency. The proposed on-chip SC voltage regulator shows better efficiency than the ideal linear regulator over a wide range of output power, from 2.6 mW to 48 mW. The 18-phase interleaving technique enables the worst-case output voltage ripple to be less than 5.77% of the load voltage.
Open AccessFully Integrated on-Chip Switched DC–DC Converter for Battery-Powered Mixed-Signal SoCs
This paper presents a fully integrated on-chip switched-capacitor (SC) DC–DC converter that supports a programmable regulated power supply ranging from 2.6 to 3.2 V out of a 5 V input supply. The proposed 4-to-3 step-down topology utilizes two conventional 2-to-1 step-down topologies; each of them (2-to-1_up and 2-to-1_dw) has a different flying capacitance to maximize the load current driving capability while minimizing the bottom-plate capacitance loss. The control circuits use a low power supply provided by a small internal low-drop output (LDO) connected to the internal load voltage (VL_dw) from the 2-to-1_dw, and low swing level-shifted gate-driving signals are generated using the internal load voltage (VL_dw). Therefore, the proposed implementation reduces control circuit and switching power consumptions. The programmable power supply voltage is regulated by means of a pulse frequency modulation (PFM) technique with the compensated two-stage operational transconductance amplifier (OTA) and the current-starved voltage controlled oscillator (VCO) to maintain high efficiency over a wide range of load currents. The proposed on-chip SC DC–DC converter is designed and simulated using high-voltage 0.35 μm bipolar, complementary metal-oxide-semiconductor (CMOS) and DMOS (BCDMOS) technology. It achieves a peak efficiency of 74% when delivering an 8 mA load current at a 3.2 V supply voltage level, and it provides a maximum output power of 48 mW (IL = 15 mA at VL_up = 3.2 V) at 70.5% efficiency. The proposed on-chip SC voltage regulator shows better efficiency than the ideal linear regulator over a wide range of output power, from 2.6 mW to 48 mW. The 18-phase interleaving technique enables the worst-case output voltage ripple to be less than 5.77% of the load voltage.