AGAmanda L. Gordon

Amanda L. Gordon

*This is an algorithmically generated author record based on publicly available information.

Amanda L. Gordon has a total of 2 co-authors. Here are the top co-authors by number of shared publications:

  • Gareth P. Campbell

    The Department of Chemistry, The University of Auckland, Private Bag 92019, Auckland, New Zealand

    1 shared publication
  • S Coulson

    ESR 1 , Private Bag 92021, Auckland, New Zealand

    1 shared publication

Latest Publications

  • Analysis of Condom Lubricants for Forensic Casework*

    by Gareth P. Campbell, Amanda L. Gordon

    The detection of DNA is inhibited in cases of sexual assault involving condom use. Trace evidence, including condom lubricant residues, provides crucial associative evidence in such cases. The existing Fourier transform infrared spectroscopy (FTIR) methods for lubricant analysis and detection are limited with regard to sensitivity and discrimination. The aim of this research was to establish a new method as an alternative to FTIR for the analysis of condom lubricant residues. Pyrolysis gas chromatography‐mass spectrometry (PyGC‐MS) and GC‐MS are highly sensitive methods of analysis for a wide range of chemical substances. PyGC‐MS and GC‐MS were used to analyze condom lubricants in standard solution, from clean swabs and from postcoital swabs. Pyrolysis of polydimethylsiloxane (PDMS) lubricant forms cyclic products known as cyclic dimethyl siloxanes (DMS), which are separated and detected by the GC‐MS. The polyethylene glycol (PEG) lubricant can be analyzed by GC‐MS directly from solution. The methods of extraction and analysis presented in this paper were shown to be significantly more sensitive than FTIR for the analysis of PDMS and PEG condom lubricants. PDMS was detected as low as 1 μg in standard solution and from clean swabs using the PyGC‐MS method. PEG was detected as low as 0.5 μg from standard solution and 50 μg from clean swabs using the GC‐MS method. Unfortunately, we were unable to provide further discrimination between condom brands and subbrands. The methods established throughout the research were used successfully to detect condom lubricants from donated postcoital swabs. Lubricants were detected in abundance on swabs 12 h postcoitus. Recommendations are made regarding implementation of new methods for routine analysis of casework samples along with strict pyrolysis interpretation criteria to minimize the possibility of misinterpretation of false positives.


  • The Evidential Value of Cosmetic Foundation Smears in Forensic Casework

    by A Gordon, S Coulson

    Cosmetic foundation products are easily transferred to clothing and other surfaces asa result ofcontact with such objects. Examination of past cases involving cosmetics in New Zealand has shown cosmetic foundation to be one of the more common cosmetic products encountered. The aim of this research was to determine the most discriminating method for the comparison of transferred foundation with samples obtained from a known source in forensic casework. Fifty-three foundation samples were analyzed by Fourier transform infrared spectroscopy (FTIR), gas chromatography with a flame ionization detector (GC-FID) and scanning electron microscopy-energy dispersive X-Ray analysis (SEM-EDX). It was found that a 5 mm2 section of a light smearing was enough to provide detectable results. The discriminating powers for FTIR, SEM-EDX and GC-FID were 98.3, 93.8, and 82.0% respectively. A combination of all three techniques provided a discriminating power of 99.7%, meaning that almost complete discrimination was achieved between the foundation samples.