Yuji Shimogonya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yuji Shimogonya has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Kazuhiro Itoh
University of Hyogo
8 shared publications Hiroshige Kumamaru
University of Hyogo
7 shared publications- Takuji Ishikawa
Tohoku University
4 shared publications - Takami Yamaguchi
Graduate School of Biomedical Engineering, Tohoku University
3 shared publications - Yohsuke Imai
Graduate School of Engineering, Kobe University , Kobe 657-8501
2 shared publications Fuma Sakata
University of Hyougo
1 shared publication
Latest Publications
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Kansai Branch
- Vol. 2013.88
123 Decompression Experiments of Sewage Sludge using a Steam Ejector
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Kansai Branch
- Vol. 2013.88
123 Decompression Experiments of Sewage Sludge using a Steam Ejector
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Kansai Branch
- Vol. 2013.88
111 Study on Micropump by using Reciprocating Motion of Magnetic Substance
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Kansai Branch
- Vol. 2013.88
111 Study on Micropump by using Reciprocating Motion of Magnetic Substance
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Kansai Branch
- Vol. 2013.88
112 Study on Rotary Micropump using Magnetic Body
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Kansai Branch
- Vol. 2013.88
112 Study on Rotary Micropump using Magnetic Body
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2013.25, 397-398
2E07 Hemodynamic Analysis of Cerebral Aneurysms : Influence of Inflow Conditions
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2013.25, 397-398
2E07 Hemodynamic Analysis of Cerebral Aneurysms : Influence of Inflow Conditions
- 28 September 2012
- Published by IGI Global Scientific Publishing
- p. 267-277
Computational Study of the Hemodynamics of Cerebral Aneurysm Initiation
This chapter aims to present the authors’ recent findings from studies on the computational biomechanics of blood flow in human arteries and its application to the hemodynamics of cerebral aneurysm initiation. They first briefly outline the techniques of computational fluid dynamics used in blood flow simulations of anatomically realistic artery models reconstructed from medical images acquired with CT or MRI. Then, the time course of the blood flow velocity field in the medical image-based model of a human internal carotid artery (ICA) is shown as a result of a pulsatile blood flow simulation with CFD techniques. Finally, the chapter presents an overview of the concept of a novel hemodynamic indicator for cerebral aneurysm initiation, the gradient oscillatory number (GON). The distribution of the GON for the medical image-based ICA model is also demonstrated.
- 28 September 2012
- Published by IGI Global Scientific Publishing
- p. 267-277
Computational Study of the Hemodynamics of Cerebral Aneurysm Initiation
This chapter aims to present the authors’ recent findings from studies on the computational biomechanics of blood flow in human arteries and its application to the hemodynamics of cerebral aneurysm initiation. They first briefly outline the techniques of computational fluid dynamics used in blood flow simulations of anatomically realistic artery models reconstructed from medical images acquired with CT or MRI. Then, the time course of the blood flow velocity field in the medical image-based model of a human internal carotid artery (ICA) is shown as a result of a pulsatile blood flow simulation with CFD techniques. Finally, the chapter presents an overview of the concept of a novel hemodynamic indicator for cerebral aneurysm initiation, the gradient oscillatory number (GON). The distribution of the GON for the medical image-based ICA model is also demonstrated.
- 1 April 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45 (6) , 985-989
Sensitivity of the gradient oscillatory number to flow input waveform shapes
- 1 April 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45 (6) , 985-989
Sensitivity of the gradient oscillatory number to flow input waveform shapes
- 1 January 2010
- Published by Japan Society of Mechanical Engineers in The Proceedings of the National Symposium on Power and Energy Systems
- Vol. 2010.15, 145-146
D109 Optical Measurements of Two-Dimensional Waveform on a High Speed Water Jet
- 1 January 2010
- Published by Japan Society of Mechanical Engineers in The Proceedings of the National Symposium on Power and Energy Systems
- Vol. 2010.15, 145-146
D109 Optical Measurements of Two-Dimensional Waveform on a High Speed Water Jet
- 1 September 2009
- Published by Taylor & Francis in International Journal of Computational Fluid Dynamics
- Vol. 23 (8) , 583-593
A realistic simulation of saccular cerebral aneurysm formation: focussing on a novel haemodynamic index, the gradient oscillatory number
Although how cerebral aneurysms initiate and grow is still unclear, haemodynamics is thought to play an important role. In order to better understand the aneurysm formation mechanism, we performed a computational analysis of aneurysm formation for a patient-specific arterial geometry. First, CFD was used to perform a pulsatile blood flow analysis and calculate a novel haemodynamic index, the gradient oscillatory number (GON). Then, using aneurysm growth model in which the proliferation of the wall was hypothesised, we performed an aneurysm formation analysis based on the GON index distribution. The result showed that a saccular cerebral aneurysm could appear based on our hypothesis for a patient-specific arterial geometry. On the other hand, a saccular aneurysm was not observed when assuming only strength degradation of the wall. Our findings have suggested that an arterial biological process, such as the proliferation of the wall, may play a vital role in saccular aneurysm formation.
- 1 September 2009
- Published by Taylor & Francis in International Journal of Computational Fluid Dynamics
- Vol. 23 (8) , 583-593
A realistic simulation of saccular cerebral aneurysm formation: focussing on a novel haemodynamic index, the gradient oscillatory number
Although how cerebral aneurysms initiate and grow is still unclear, haemodynamics is thought to play an important role. In order to better understand the aneurysm formation mechanism, we performed a computational analysis of aneurysm formation for a patient-specific arterial geometry. First, CFD was used to perform a pulsatile blood flow analysis and calculate a novel haemodynamic index, the gradient oscillatory number (GON). Then, using aneurysm growth model in which the proliferation of the wall was hypothesised, we performed an aneurysm formation analysis based on the GON index distribution. The result showed that a saccular cerebral aneurysm could appear based on our hypothesis for a patient-specific arterial geometry. On the other hand, a saccular aneurysm was not observed when assuming only strength degradation of the wall. Our findings have suggested that an arterial biological process, such as the proliferation of the wall, may play a vital role in saccular aneurysm formation.
- 1 January 2009
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Tohoku Branch
- Vol. 2009.44, 188-189
198 Flow analysis of digested material in the small intestine
- 1 January 2009
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Tohoku Branch
- Vol. 2009.44, 188-189
198 Flow analysis of digested material in the small intestine