MMMichael S. Morgan

Michael S. Morgan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael S. Morgan has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ethanol-Induced Increase in the Metabolic Clearance of 1,1,1-Trichloroethane in Human Volunteers

    by Douglas O. Johns, William E. Daniell, Danny D. Shen, David A. Kalman, Russell L. Dills, Michael S. Morgan

    This study evaluated the effect of moderate doses of ethanol over a short period of time on the toxicokinetics of an organic solvent, 1,1,1-trichloroethane. A group of 10 moderate drinkers were recruited and exposed via inhalation for 2 h to a low concentration of 1,1,1-trichloroethane (175 ppm) on two separate occasions. Subjects were administered ethanol (0.35 g/kg body weight) on each of the 7 days preceding one of the exposures. Blood and urine samples were collected during and following each exposure, with blood analyzed for 1,1,1-trichloroethane and urine analyzed for the metabolites of 1,1,1-trichloroethane: trichloroethanol and trichloroacetic acid. Prior ethanol consumption resulted in a significant increase in apparent metabolic clearance of 1,1,1-trichloroethane (mean increase = 25.4%). The results of this study demonstrate that ethanol consumption over time can affect the rate at which an organic solvent is cleared through metabolism in humans. For chemicals with toxic metabolic products, this inductive effect of ethanol consumption on the rate of biotransformation could be potentially harmful to exposed individuals. Metabolic clearance of compounds with high hepatic extraction may not be affected by enzyme induction as it is likely that these compounds are essentially completely metabolized while passing through the liver.


  • The biological exposure indices: a key component in protecting workers from toxic chemicals.

    by M S Morgan

    Biological monitoring of exposure to chemicals in the workplace is an important component of exposure assessment and prevention of adverse health effects. It should be employed in conjunction with ambient air monitoring to provide information on the absorbed dose of a chemical agent and the effect of all routes of exposure. Judgments regarding the acceptable level of a chemical or its metabolite in biological samples are facilitated by comparison to a reference value. The American Conference of Governmental Industrial Hygienists has established a series of recommended reference values called the Biological Exposure Indices (BEI). The history and characteristics of the BEI are reviewed, and their suitability for use by occupational health specialists is examined. A number of challenges and stimuli to the continued development and improvement of these reference values are described, and the impact of recent advances in macromolecular biology is assessed.


    • 1 April 1994
      • Vol. 4  (2) , 229-45

    Inter-individual variability in blood/air partitioning of volatile organic compounds and correlation with blood chemistry.

    by R L Dills, W S Ackerlund, D A Kalman, M S Morgan

    In vitro blood/air partition coefficients (KB/A) for acetone, 1,1,1-trichloroethane, toluene, and styrene were measured in blood samples from 73 human subjects and correlated with blood chemistry parameters (hematocrit, total cholesterol, serum triglycerides, serum albumin, total plasma proteins, Na+, K+, Cl-, and HCO3-). Statistically significant inter-individual variation existed in KB/A between some subjects. Substitution of group or generic in vitro KB/A values for values determined in some individuals could introduce errors of up to 50%. However, most subjects could be well represented by group averages (mean +/- SD; acetone, 301 +/- 22; 1,1,1-trichloroethane, 6.0 +/- 0.8; toluene, 19 +/- 3; styrene, 62 +/- 10). The KB/A values for acetone, 1,1,1-trichloroethane and toluene were normally distributed. The data for styrene appeared to deviate from a normal distribution and may have been bimodal. The KB/A values for the two structurally related compounds, toluene and styrene, were strongly correlated within individuals, while the KB/A values for compounds with less structural similarity, such as acetone and styrene, were poorly correlated. At most, 15% of the variation in KB/A among individuals could be explained by variation in the measured blood chemistry parameters. When the entire sample group was considered, blood chemistry parameters were not significantly correlated with KB/A for any compound. The KB/A of 1,1,1-trichloroethane was significantly correlated with the concentration of cholesterol and triglycerides in females. Sex was a significant grouping variable for the correlation of albumin concentration with the KB/A of styrene. Age was not a significant correlation variable. Blood chemistry parameters which previously have been correlated with KB/A in small sample groups do not appear to be significantly correlated in our larger sample group.


    • 1 October 1993
      • Vol. 3  (4) , 471-89

    Blood/air partition coefficient determinations: automation and improvement of the equilibrium partitioning in closed systems method.

    by R L Dills, W S Ackerlund, D A Kalman, M S Morgan

    The equilibrium partitioning in closed systems method has been frequently used for determining partition coefficients between liquid and gas phases. We developed several improvements in this method: preparation of test atmospheres with a dynamic solvent vapor generator, automation of gas phase analysis, and estimation of the precision of the partition coefficients using a statistical procedure that did not require pairing of test and reference measurements. Blood/air partition coefficients measured in a blood-bank blood sample for acetone, 1,1,1-trichloroethane, toluene, and styrene were: 309 +/- 2, 5.6 +/- 0.1, 16.2 +/- 0.5 and 49 +/- 2 (geometric mean +/- estimated SE, respectively). Water/air partition coefficients were: 361 +/- 7, 2.9 +/- 0.3, 4.6 +/- 0.5, and 6.9 +/- 0.9 for acetone, 1,1,1-trichloroethane, toluene, and styrene.

  • Evaluation of stable isotope-labeled probes in the study of solvent pharmacokinetics in human subjects

    by Michael S. Morgan, Russell L. Dills, David A. Kalman

    Summary The relationship between biomarkers of exposure (such as concentrations of toxicants in blood or breath, or metabolites in urine) and toxicant dose for individuals is influenced by many person- and episode-specific factors which contribute to overall variability in biomarker level for a given dose. This variability results in imprecise biological marker-based estimates of dose for individuals. We hypothesize that pharmacokinetic data from stable-isotope (deuterated) analogs can be used with a pharmacokinetic model to account for individual-related sources of variation, leading to more precise methods of dose estimation for individuals. To establish the degree of similarity in the pharmacokinetics of unlabeled (d0-) and fully deuterated (d8-) toluene, 21 men (ages 20–45) inhaled an equal molar mixture for 2 h. Washout kinetics for both compounds were followed for 4 d in alveolar air and blood. Both compounds exhibited three-phase elimination kinetics in both fluids. The third phase was not always definable for d0- toluene because of concurrent uncontrolled environmental exposures. Considering data from only the first two phases, concentrations of d0- and d8-toluene in alveolar air and blood were well correlated for all subjects, even though pharmacokinetic parameters varied among individuals by 5–9 folds. Further experiments are needed to discern whether correlations between d0- and d8-toluene for the third phase are influenced by an isotope effect; present data support use of d8-toluene as a suitable probe for d0-kinetics.