Kenneth A. Egol
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kenneth A. Egol has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Nirmal C. Tejwani
Department of Orthopaedic Surgery, Grossman School of Medicine, NYU Langone Health, New York, New York
5 shared publications Kenneth J. Koval
2 shared publications- Michael G. Walsh
Sydney School of Public Health, Faculty of Medicine and Health, The University of Sydney, Camperdown, Australia
2 shared publications - Nader Paksima
Department of Orthopaedic Surgery, New York University Hospital for Joint Diseases, New York, NY 10016, USA
2 shared publications C. Wynn
Department of Orthopaedic Surgery The New York University Hospital for Joint Diseases, 301 East 17th Street, New York, New York 10003, USA
1 shared publicationCraig M. Capeci
Department of Orthopaedic Surgery, New York University Hospital for Joint Diseases, 301 East 17th Street, New York, NY 10003. address for D.E. Ruchelsman:. address for C.M. Capeci:. address for J.D. Zuckerman:. address for K.A. Egol
1 shared publication
Latest Publications
- 15 April 2009
- Published by Taylor & Francis in Journal of Hospital Librarianship
- Vol. 9 (2) , 123-138
Building Orthopedic Journal Collections: Analyzing Use and Bibliometrics in a Teaching Hospital Library
This article presents a collection development tool that identifies a list of key orthopedic journals to retain in print or license electronically in an academic or teaching hospital library. The authors developed an assessment tool comparing five measures of importance and use, including journal impact factor, cited half-life, interlibrary loan lending, electronic archival access, and library usage. This study assists medical librarians and orthopedic surgeons by identifying the titles in this subject area that may be of most enduring value for professional reading and for hospital library collections.
- 15 April 2009
- Published by Taylor & Francis in Journal of Hospital Librarianship
- Vol. 9 (2) , 123-138
Building Orthopedic Journal Collections: Analyzing Use and Bibliometrics in a Teaching Hospital Library
This article presents a collection development tool that identifies a list of key orthopedic journals to retain in print or license electronically in an academic or teaching hospital library. The authors developed an assessment tool comparing five measures of importance and use, including journal impact factor, cited half-life, interlibrary loan lending, electronic archival access, and library usage. This study assists medical librarians and orthopedic surgeons by identifying the titles in this subject area that may be of most enduring value for professional reading and for hospital library collections.
- 1 September 2008
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 90-B (9) , 1214-1221
Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius
We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-locked plating with screws. Both groups were similar in terms of age, gender, hand dominance, fracture pattern, socio-economic status and medical co-morbidities. Although the patients treated by volar plating had a statistically significant early improvement in the range of movement of the wrist, this advantage diminished with time and in absolute terms the difference in range of movement was clinically unimportant. Radiologically, there were no clinically significant differences in the reductions, although more patients with AO/OTA (Orthopaedic Trauma Association) type C fractures were allocated to the external fixation group. The function at one year was similar in the two groups. No clear advantage could be demonstrated with either treatment but fewer re-operations were required in the external fixation group.
- 1 September 2008
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 90-B (9) , 1214-1221
Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius
We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-locked plating with screws. Both groups were similar in terms of age, gender, hand dominance, fracture pattern, socio-economic status and medical co-morbidities. Although the patients treated by volar plating had a statistically significant early improvement in the range of movement of the wrist, this advantage diminished with time and in absolute terms the difference in range of movement was clinically unimportant. Radiologically, there were no clinically significant differences in the reductions, although more patients with AO/OTA (Orthopaedic Trauma Association) type C fractures were allocated to the external fixation group. The function at one year was similar in the two groups. No clear advantage could be demonstrated with either treatment but fewer re-operations were required in the external fixation group.
- 1 June 2008
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 90 (6) , 1321-1329
Open Reduction and Internal Fixation of Capitellar Fractures with Headless Screws
Background: The outcome of operatively treated capitellar fractures has not been reported frequently. The purpose of the present study was to evaluate the clinical, radiographic, and functional outcomes following open reduction and internal fixation of capitellar fractures that were treated with a uniform surgical approach in order to further define the impact on the outcome of fracture type and concomitant lateral column osseous and/or ligamentous injuries. Methods: A retrospective evaluation of the upper extremity database at our institution identified sixteen skeletally mature patients (mean age, 40 ± 17 years) with a closed capitellar fracture. In all cases, an extensile lateral exposure and articular fixation with buried cannulated variable-pitch headless compression screws was performed at a mean of ten days after the injury. Clinical, radiographic, and elbow-specific outcomes, including the Mayo Elbow Performance Index, were evaluated at a mean of 27 ± 19 months postoperatively. Results: Six Type-I, two Type-III, and eight Type-IV fractures were identified with use of the Bryan and Morrey classification system. Four of five ipsilateral radial head fractures occurred in association with a Type-IV fracture. The lateral collateral ligament was intact in fifteen of the sixteen elbows. Metaphyseal comminution was observed in association with five fractures (including four Type-IV fractures and one Type-III fracture). Supplemental mini-fragment screws were used for four of eight Type-IV fractures and one of two Type-III fractures. All fractures healed, and no elbow had instability or weakness. Overall, the mean ulnohumeral motion was 123° (range, 70° to 150°). Fourteen of the sixteen patients achieved a functional arc of elbow motion, and all patients had full forearm rotation. The mean Mayo Elbow Performance Index score was 92 ± 10 points, with nine excellent results, six good results, and one fair result. Patients with a Type-IV fracture had a greater magnitude of flexion contracture (p = 0.04), reduced terminal flexion (p = 0.02), and a reduced net ulnohumeral arc (p = 0.01). An ipsilateral radial head fracture did not appear to affect ulnohumeral motion or the functional outcome. Conclusions: Despite the presence of greater flexion contractures at the time of follow-up in elbows with Type-IV fractures or fractures with an ipsilateral radial head fracture, good to excellent outcomes with functional ulnohumeral motion can be achieved following internal fixation of these complex fractures. Type-IV injuries may be more common than previously thought; such fractures often are associated with metaphyseal comminution or a radial head fracture and may require supplemental fixation. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
- 1 June 2008
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 90 (6) , 1321-1329
Open Reduction and Internal Fixation of Capitellar Fractures with Headless Screws
Background: The outcome of operatively treated capitellar fractures has not been reported frequently. The purpose of the present study was to evaluate the clinical, radiographic, and functional outcomes following open reduction and internal fixation of capitellar fractures that were treated with a uniform surgical approach in order to further define the impact on the outcome of fracture type and concomitant lateral column osseous and/or ligamentous injuries. Methods: A retrospective evaluation of the upper extremity database at our institution identified sixteen skeletally mature patients (mean age, 40 ± 17 years) with a closed capitellar fracture. In all cases, an extensile lateral exposure and articular fixation with buried cannulated variable-pitch headless compression screws was performed at a mean of ten days after the injury. Clinical, radiographic, and elbow-specific outcomes, including the Mayo Elbow Performance Index, were evaluated at a mean of 27 ± 19 months postoperatively. Results: Six Type-I, two Type-III, and eight Type-IV fractures were identified with use of the Bryan and Morrey classification system. Four of five ipsilateral radial head fractures occurred in association with a Type-IV fracture. The lateral collateral ligament was intact in fifteen of the sixteen elbows. Metaphyseal comminution was observed in association with five fractures (including four Type-IV fractures and one Type-III fracture). Supplemental mini-fragment screws were used for four of eight Type-IV fractures and one of two Type-III fractures. All fractures healed, and no elbow had instability or weakness. Overall, the mean ulnohumeral motion was 123° (range, 70° to 150°). Fourteen of the sixteen patients achieved a functional arc of elbow motion, and all patients had full forearm rotation. The mean Mayo Elbow Performance Index score was 92 ± 10 points, with nine excellent results, six good results, and one fair result. Patients with a Type-IV fracture had a greater magnitude of flexion contracture (p = 0.04), reduced terminal flexion (p = 0.02), and a reduced net ulnohumeral arc (p = 0.01). An ipsilateral radial head fracture did not appear to affect ulnohumeral motion or the functional outcome. Conclusions: Despite the presence of greater flexion contractures at the time of follow-up in elbows with Type-IV fractures or fractures with an ipsilateral radial head fracture, good to excellent outcomes with functional ulnohumeral motion can be achieved following internal fixation of these complex fractures. Type-IV injuries may be more common than previously thought; such fractures often are associated with metaphyseal comminution or a radial head fracture and may require supplemental fixation. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
- 1 April 2008
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 90 (4) , 924-927
Operative Experience in an Orthopaedic Surgery Residency Program: The Effect of Work-Hour Restrictions
Background: The implementation of Section 405 of the New York State Public Health Code and the adoption of similar policies by the Accreditation Council for Graduate Medical Education in 2002 restricted resident work hours to eighty hours per week. The effect of these policies on operative volume in an orthopaedic surgery residency training program is a topic of concern. The purpose of this study was to evaluate the effect of the work-hour restrictions on the operative experiences of residents in a large university-based orthopaedic surgery residency training program in an urban setting. Methods: We analyzed the operative logs of 109 consecutive orthopaedic surgery residents (postgraduate years 2 through 5) from 2000 through 2006, representing a consecutive interval of years before and after the adoption of the work-hour restrictions. Results: Following the implementation of the new work-hour policies, there was no significant difference in the operative volume for postgraduate year-2, 3, or 4 residents. However, the average operative volume for a postgraduate year-5 resident increased from 274.8 to 348.4 cases (p = 0.001). In addition, on analysis of all residents as two cohorts (before 2002 and after 2002), the operative volume for residents increased by an average of 46.6 cases per year (p = 0.02). Conclusions: On the basis of the findings of this study, concerns over the potential adverse effects of the resident work-hour polices on operative volume for orthopaedic surgery residents appear to be unfounded.
- 1 April 2008
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 90 (4) , 924-927
Operative Experience in an Orthopaedic Surgery Residency Program: The Effect of Work-Hour Restrictions
Background: The implementation of Section 405 of the New York State Public Health Code and the adoption of similar policies by the Accreditation Council for Graduate Medical Education in 2002 restricted resident work hours to eighty hours per week. The effect of these policies on operative volume in an orthopaedic surgery residency training program is a topic of concern. The purpose of this study was to evaluate the effect of the work-hour restrictions on the operative experiences of residents in a large university-based orthopaedic surgery residency training program in an urban setting. Methods: We analyzed the operative logs of 109 consecutive orthopaedic surgery residents (postgraduate years 2 through 5) from 2000 through 2006, representing a consecutive interval of years before and after the adoption of the work-hour restrictions. Results: Following the implementation of the new work-hour policies, there was no significant difference in the operative volume for postgraduate year-2, 3, or 4 residents. However, the average operative volume for a postgraduate year-5 resident increased from 274.8 to 348.4 cases (p = 0.001). In addition, on analysis of all residents as two cohorts (before 2002 and after 2002), the operative volume for residents increased by an average of 46.6 cases per year (p = 0.02). Conclusions: On the basis of the findings of this study, concerns over the potential adverse effects of the resident work-hour polices on operative volume for orthopaedic surgery residents appear to be unfounded.
- 1 March 2008
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 22 (3) , 159-164
Early Complications in Proximal Humerus Fractures (OTA Types 11) Treated With Locked Plates
To examine our incidence of early complications that occur using the Proximal Humeral Internal Locking System (PHILOS) and to determine the contributing factors. Academic medical center. Fifty-one consecutive patients treated with a proximal humerus locking plate. Development of an intraoperative, acute postoperative, or delayed postoperative complication. A retrospective analysis was undertaken of a consecutive series of proximal humerus fractures treated with a locking plate between February 2003 and January 2006 at our institution. Fifty-one fractures or fracture nonunions were identified in 18 male and 33 female patients with an average age of 61. All acute injuries were treated with a similar protocol of open reduction internal fixation with the PHILOS plate followed by early range of shoulder motion. Nonunions were treated in a similar manner with the addition of iliac crest bone graft placement. Patients were objectively assessed on their outcome by physical as well as radiological examination. All complications were recorded. Statistical analyses were performed to determine if patient age, fracture type, or number of screws placed in the humeral head contributed to complications. Fifty-one patients were available for minimum 6-month follow-up (mean, 16 months; range, 6 to 45 months). Radiographically, 92% of the cases united at 3 months after surgery, and 2 fractures had signs of osteonecrosis at latest follow-up. Sixteen complications were seen in 12 patients (24%). Eight shoulders in eight patients (16%) had screws that penetrated the humeral head. Two patients developed osteonecrosis at latest follow-up. One acute fracture and one nonunion failed to unite after index surgery. Significant heterotopic bone developed in 1 patient. Early implant failure occurred in 2 patients; one was revised to a longer plate, and one underwent resection arthroplasty. There was one acute postoperative infection. The major complication reported in this study was screw penetration, suggesting that exceptional vigilance must be taken in estimating the appropriate number and length of screws used to prevent articular penetration; although the device provides exceptional fixation stability, its indication must be scrutinized for each individual patient, taking the extent of trauma/fracture and age into consideration and carefully weighing it against other forms of treatment.
- 1 March 2008
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 22 (3) , 159-164
Early Complications in Proximal Humerus Fractures (OTA Types 11) Treated With Locked Plates
To examine our incidence of early complications that occur using the Proximal Humeral Internal Locking System (PHILOS) and to determine the contributing factors. Academic medical center. Fifty-one consecutive patients treated with a proximal humerus locking plate. Development of an intraoperative, acute postoperative, or delayed postoperative complication. A retrospective analysis was undertaken of a consecutive series of proximal humerus fractures treated with a locking plate between February 2003 and January 2006 at our institution. Fifty-one fractures or fracture nonunions were identified in 18 male and 33 female patients with an average age of 61. All acute injuries were treated with a similar protocol of open reduction internal fixation with the PHILOS plate followed by early range of shoulder motion. Nonunions were treated in a similar manner with the addition of iliac crest bone graft placement. Patients were objectively assessed on their outcome by physical as well as radiological examination. All complications were recorded. Statistical analyses were performed to determine if patient age, fracture type, or number of screws placed in the humeral head contributed to complications. Fifty-one patients were available for minimum 6-month follow-up (mean, 16 months; range, 6 to 45 months). Radiographically, 92% of the cases united at 3 months after surgery, and 2 fractures had signs of osteonecrosis at latest follow-up. Sixteen complications were seen in 12 patients (24%). Eight shoulders in eight patients (16%) had screws that penetrated the humeral head. Two patients developed osteonecrosis at latest follow-up. One acute fracture and one nonunion failed to unite after index surgery. Significant heterotopic bone developed in 1 patient. Early implant failure occurred in 2 patients; one was revised to a longer plate, and one underwent resection arthroplasty. There was one acute postoperative infection. The major complication reported in this study was screw penetration, suggesting that exceptional vigilance must be taken in estimating the appropriate number and length of screws used to prevent articular penetration; although the device provides exceptional fixation stability, its indication must be scrutinized for each individual patient, taking the extent of trauma/fracture and age into consideration and carefully weighing it against other forms of treatment.
- 1 January 2007
- Vol. 65 (4) , 263-70
Fracture-dislocation of the elbow functional outcome following treatment with a standardized protocol.
Fracture-dislocation of the elbow is a signiicant injury with mixed outcomes. The purpose of the study was to evaluate patient perceived outcome following surgical stabilization of these complex injuries. Twenty-nine available patients (76%) from 37 identiied with "terrible triad" injury patterns, in- cluding ulnohumeral dislocation, radial head fracture, and coronoid fracture, were available for a minimum 1-year follow-up (mean, 27 months). All patients were evaluated by their treating physician. Radiographic outcome was evaluated at latest follow-up. Functional outcome was based upon DASH, Mayo elbow performance, and Broberg-Mor- rey scores. Complications were recorded. Results included that the average lexion-extension arc of elbow motion was 109 degrees +/- 27 degrees , and the average pronation-supination arc was 128 degrees +/- 44 degrees . Grip strength averaged 72% of the contralateral extremity. The Mayo score was a mean of 81 (range, 45 to 100), the Broberg-Morrey mean was 77 (range, 33 to 100) The mean DASH was 28 (range, 0 to 72). When compared to the age-based normal values, the mean patient's DASH score was 1.4 SD worse than an average person of the same age None of the injury characteristics, patient demographics or treatment modalities was signiicantly associated with a poor outcome at the 95% conidence interval. Conclusions are that the results with terrible triad injuries are often unsatisfactory, but surgical management with the use of a systematic approach may be beneicial. Our approach led to the restoration of elbow joint stability in all patients.
- 1 January 2007
- Vol. 65 (4) , 263-70
Fracture-dislocation of the elbow functional outcome following treatment with a standardized protocol.
Fracture-dislocation of the elbow is a signiicant injury with mixed outcomes. The purpose of the study was to evaluate patient perceived outcome following surgical stabilization of these complex injuries. Twenty-nine available patients (76%) from 37 identiied with "terrible triad" injury patterns, in- cluding ulnohumeral dislocation, radial head fracture, and coronoid fracture, were available for a minimum 1-year follow-up (mean, 27 months). All patients were evaluated by their treating physician. Radiographic outcome was evaluated at latest follow-up. Functional outcome was based upon DASH, Mayo elbow performance, and Broberg-Mor- rey scores. Complications were recorded. Results included that the average lexion-extension arc of elbow motion was 109 degrees +/- 27 degrees , and the average pronation-supination arc was 128 degrees +/- 44 degrees . Grip strength averaged 72% of the contralateral extremity. The Mayo score was a mean of 81 (range, 45 to 100), the Broberg-Morrey mean was 77 (range, 33 to 100) The mean DASH was 28 (range, 0 to 72). When compared to the age-based normal values, the mean patient's DASH score was 1.4 SD worse than an average person of the same age None of the injury characteristics, patient demographics or treatment modalities was signiicantly associated with a poor outcome at the 95% conidence interval. Conclusions are that the results with terrible triad injuries are often unsatisfactory, but surgical management with the use of a systematic approach may be beneicial. Our approach led to the restoration of elbow joint stability in all patients.
- 1 November 2006
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 88 (11) , 2535
Erratum
- 1 November 2006
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 88 (11) , 2535
Erratum
- 1 May 2006
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 88 (5) , 974-979
Predictors of Short-Term Functional Outcome Following Ankle Fracture Surgery
Udy, we evaluated predictors of short-term functional outcome following surgical stabilization of ankle fractures....
- 1 May 2006
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 88 (5) , 974-979
Predictors of Short-Term Functional Outcome Following Ankle Fracture Surgery
Udy, we evaluated predictors of short-term functional outcome following surgical stabilization of ankle fractures....
- 1 January 2006
- Vol. 26, 112-8
Concomitant ipsilateral femoral neck and femoral shaft fracture nonunions: a report of three cases and a review of the literature.
Ipsilateral femoral neck and femoral shaft fractures are rarely reported in the literature and represent a diagnostic and treatment challenge. Due to the possibility of missing a nonunion at either site, we recommend a high clinical suspicion and careful radiographic examination of both fracture sites. Because the development of nonunion at both sites is exceedingly rare, we report three cases of concomitant ipsilateral femoral neck and shaft nonunions that were treated by the senior author (KAE). Two patients were treated with a Pauwels osteotomy and a blade plate for the femoral neck nonunion and a reamed retrograde intramedullary nail for the shaft. One patient was treated with an antegrade reamed cephalomedullary intramedullary nail. All three patients' fractures united at a mean of 4.6 months and they are currently pain free and without physical limitations.
- 1 January 2006
- Vol. 26, 112-8
Concomitant ipsilateral femoral neck and femoral shaft fracture nonunions: a report of three cases and a review of the literature.
Ipsilateral femoral neck and femoral shaft fractures are rarely reported in the literature and represent a diagnostic and treatment challenge. Due to the possibility of missing a nonunion at either site, we recommend a high clinical suspicion and careful radiographic examination of both fracture sites. Because the development of nonunion at both sites is exceedingly rare, we report three cases of concomitant ipsilateral femoral neck and shaft nonunions that were treated by the senior author (KAE). Two patients were treated with a Pauwels osteotomy and a blade plate for the femoral neck nonunion and a reamed retrograde intramedullary nail for the shaft. One patient was treated with an antegrade reamed cephalomedullary intramedullary nail. All three patients' fractures united at a mean of 4.6 months and they are currently pain free and without physical limitations.