Robert W. Collins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Robert W. Collins has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Andre Santarosa Ferlauto
Center for Engineering, Modeling and Applied Social Sciences, Federal University of ABC
3 shared publications Joungchel Lee
Materials Research Laboratory, The Pennsylvania State University, University Park 16802, USA
3 shared publicationsIlsin An
Department of Physics and Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
2 shared publicationsA.S. Lawrence
Department of Physics and Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
1 shared publicationC. R. Wronskii
Departments of Electrical Engineering and The Pennsylvania State University, University Park, PA 16802
1 shared publicationC.R Wronski
Department of Physics, Materials Research Laboratory and Center for Thin Film Devices, The Pennsylvania State University, University Park, PA 16802, USA
1 shared publication
Latest Publications
- 15 September 2007
- Published by Wiley
Ellipsometry
- 15 July 2004
- Published by Wiley
Ellipsometry
- 24 April 2004
- Published by Elsevier in Thin Solid Films
- Vol. 455-456, 132-137
Calibration and data reduction for a UV-extended rotating-compensator multichannel ellipsometer
- 24 April 2004
- Published by Elsevier in Thin Solid Films
- Vol. 455-456, 132-137
Calibration and data reduction for a UV-extended rotating-compensator multichannel ellipsometer
- 17 January 2002
- Published by Elsevier in Journal of Non-Crystalline Solids
- Vol. 299-302, 1136-1141
Mobility gap profiles in Si:H intrinsic layers prepared by H2-dilution of SiH4: effects on the performance of p–i–n solar cells
- 17 January 2002
- Published by Elsevier in Journal of Non-Crystalline Solids
- Vol. 299-302, 1136-1141
Mobility gap profiles in Si:H intrinsic layers prepared by H2-dilution of SiH4: effects on the performance of p–i–n solar cells
- 24 December 2001
- Published by Elsevier in Journal of Non-Crystalline Solids
- Vol. 299-302, 68-73
Phase diagrams for Si:H film growth by plasma-enhanced chemical vapor deposition
- 24 December 2001
- Published by Elsevier in Journal of Non-Crystalline Solids
- Vol. 299-302, 68-73
Phase diagrams for Si:H film growth by plasma-enhanced chemical vapor deposition
- 1 August 2001
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 18 (8) , 1980-1985
Alignment and calibration of the MgF_2 biplate compensator for applications in rotating-compensator multichannel ellipsometry
Biplate compensators made from are being used increasingly in rotating-element single-channel and multichannel ellipsometers. For the measurement of accurate ellipsometric spectra, the compensator must be carefully (i) aligned internally to ensure that the fast axes of the two plates are perpendicular and (ii) calibrated to determine the phase retardance δ versus photon energy E. We present alignment and calibration procedures for multichannel ellipsometer configurations with special attention directed to the precision, accuracy, and reproducibility in the determination of Run-to-run variations in external compensator alignment, i.e., alignment with respect to the incident beam, can lead to irreproducibilities in δ of ∼0.2°. Errors in the ellipsometric measurement of a sample can be minimized by calibrating with an external compensator alignment that matches as closely as possible that used in the measurement.- 1 August 2001
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 18 (8) , 1980-1985
Alignment and calibration of the MgF_2 biplate compensator for applications in rotating-compensator multichannel ellipsometry
Biplate compensators made from are being used increasingly in rotating-element single-channel and multichannel ellipsometers. For the measurement of accurate ellipsometric spectra, the compensator must be carefully (i) aligned internally to ensure that the fast axes of the two plates are perpendicular and (ii) calibrated to determine the phase retardance δ versus photon energy E. We present alignment and calibration procedures for multichannel ellipsometer configurations with special attention directed to the precision, accuracy, and reproducibility in the determination of Run-to-run variations in external compensator alignment, i.e., alignment with respect to the incident beam, can lead to irreproducibilities in δ of ∼0.2°. Errors in the ellipsometric measurement of a sample can be minimized by calibrating with an external compensator alignment that matches as closely as possible that used in the measurement.- 31 July 1998
- Published by Elsevier in Diamond and Related Materials
- Vol. 7 (7) , 999-1009
Analysis of the ellipsometric spectra of amorphous carbon thin films for evaluation of the sp3-bonded carbon content
- 31 July 1998
- Published by Elsevier in Diamond and Related Materials
- Vol. 7 (7) , 999-1009
Analysis of the ellipsometric spectra of amorphous carbon thin films for evaluation of the sp3-bonded carbon content
- 24 March 1997
- Published by AIP Publishing in Applied Physics Letters
- Vol. 70 (12) , 1527-1529
Low temperature plasma process based on CO-rich CO/H2 mixtures for high rate diamond film deposition
A low temperature process (350 °C<T<500 °C) for nanocrystalline diamond film growth by microwave plasma-enhanced chemical vapor deposition has been developed that yields high rates (up to 2.5 μm/h) at relatively low plasma powers (0.5 kW). In contrast to the widely used H2-rich mixtures of CH4 or CO and H2 that exhibit monotonic decreases in the diamond growth rate as T is reduced from 800 to 400 °C, CO-rich mixtures of CO and H2 exhibit an increase and sharp maximum as T is reduced. The results suggest a different diamond growth mechanism from the CO-rich mixtures.
- 24 March 1997
- Published by AIP Publishing in Applied Physics Letters
- Vol. 70 (12) , 1527-1529
Low temperature plasma process based on CO-rich CO/H2 mixtures for high rate diamond film deposition
A low temperature process (350 °C<T<500 °C) for nanocrystalline diamond film growth by microwave plasma-enhanced chemical vapor deposition has been developed that yields high rates (up to 2.5 μm/h) at relatively low plasma powers (0.5 kW). In contrast to the widely used H2-rich mixtures of CH4 or CO and H2 that exhibit monotonic decreases in the diamond growth rate as T is reduced from 800 to 400 °C, CO-rich mixtures of CO and H2 exhibit an increase and sharp maximum as T is reduced. The results suggest a different diamond growth mechanism from the CO-rich mixtures.
- 1 January 1996
- Published by Springer Nature in MRS Proceedings
- Vol. 452
Nucleation and Growth of μc-Si:H n- and p-Type Layers in a-Si:H p-i-n AND n-i-p Solar Cells: Real Time Spectroellpsometry Studies
- 1 January 1996
- Published by Springer Nature in MRS Proceedings
- Vol. 452
Nucleation and Growth of μc-Si:H n- and p-Type Layers in a-Si:H p-i-n AND n-i-p Solar Cells: Real Time Spectroellpsometry Studies