CMC. Cameron Miller

C. Cameron Miller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


C. Cameron Miller has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Models for an Ultraviolet-C Research and Development Consortium

    by Dianne L. Poster, Michael T. Postek, Yaw S. Obeng, John J. Kasianowicz, Troy E. Cowan, Norman R. Horn, C. Cameron Miller, Richard A. Martinello

    The development of an international, precompetitive, collaborative, ultraviolet (UV) research consortium is discussed as an opportunity to lay the groundwork for a new UV commercial industry and the supply chain to support this industry. History has demonstrated that consortia can offer promising approaches to solve many common, current industry challenges, such as the paucity of data regarding the doses of ultraviolet-C (UV-C, 200 nm to 280 nm) radiation necessary to achieve the desired reductions in healthcare pathogens and the ability of mobile disinfection devices to deliver adequate doses to the different types of surfaces in a whole-room environment. Standard methods for testing are only in the initial stages of development, making it difficult to choose a specific UV-C device for a healthcare application. Currently, the public interest in UV-C disinfection applications is elevated due to the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that causes the respiratory coronavirus disease 19 (COVID-19). By channeling the expertise of different UV industry stakeholder sectors into a unified international consortium, innovation in UV measurements and data could be developed to support test methods and standards development for UV healthcare equipment. As discussed in this paper, several successful examples of consortia are applicable to the UV industry to help solve these types of common problems. It is anticipated that a consortium for the industry could lead to UV applications for disinfection becoming globally prolific and commonplace in residential, work, business, and school settings as well as in transportation (bus, rail, air, ship) environments. Aggressive elimination of infectious agents by UV-C technologies would also help to reduce the evolution of antibiotic-resistant bacteria.


  • Open Access

    Mean Differential Continuous Pulse Method for Accurate Optical Measurements of Light-Emitting Diodes and Laser Diodes

    by Yuqin Zong, Jeff Hulett, Naomasa Koide, Yoshiki Yamaji, C. Cameron Miller

    Limited sources exist for the application of germicidal ultraviolet (GUV) radiation. Ultraviolet light-emitting diodes (UV-LEDs) have significantly improved in efficiency and are becoming another viable source for GUV. We have developed a mean differential continuous pulse method (M-DCP method) for optical measurements of light-emitting diodes (LEDs) and laser diodes (LDs). The new M-DCP method provides an improvement on measurement uncertainty by one order of magnitude compared to the unpublished differential continuous pulse method (DCP method). The DCP method was already a significant improvement of the continuous pulse method (CP method) commonly used in the LED industry. The new M-DCP method also makes it possible to measure UV-LEDs with high accuracy. Here, we present the DCP method, discuss the potential systematic error sources in it, and present the M-DCP method along with its reduced systematic errors. This paper also presents the results of validation measurement of LEDs using the M-DCP method and common test instruments.


  • Open Access

    Ultraviolet Radiation Technologies and Healthcare Associated Infections: Standards and Metrology Needs

    by Dianne L. Poster, C. Cameron Miller, Richard A. Martinello, Norman R. Horn, Michael T. Postek, Troy E. Cowan, Yaw S. Obeng, John J. Kasianowicz

    The National Institute of Standards and Technology (NIST) hosted an international workshop on ultraviolet-C (UV-C) disinfection technologies on January 14–15, 2020, in Gaithersburg, Maryland, in collaboration with the International Ultraviolet Association (IUVA). This successful public event, as evidenced by the participation of more than 150 attendees, with 65% from the ultraviolet technology industry, was part of an ongoing collaborative effort between NIST and the IUVA and its affiliates to examine the measurement and standards needs for pathogen abatement with UV-C in the healthcare whole-room environment. Prior to and since this event, stakeholders from industry, academia, government, and public health services have been collaboratively engaged with NIST to accelerate the development and use of accurate measurements and models for UV-C disinfection technologies and facilitate technology transfer. The workshop served as an open forum to continue this discussion with a technical focus centered on the effective design, use, and implementation of UV-C technologies for the prevention and treatment of healthcare-associated infections (HAIs) in complex hospital settings. These settings include patient rooms, operating rooms, common staging areas, ventilation systems, personal protective equipment, and tools for the reprocessing and disinfecting of instruments or devices used in medical procedures, such as catheters and ventilators. The critical need for UV-C technologies for disinfection has been amplified by the outbreak of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that causes coronavirus disease 2019 (COVID-19), stimulating an even greater emphasis on identifying testing and performance metrology needs. This paper discusses these topics based on the international workshop and community activities since the workshop, including a public World-Wide-Web–based seminar with more than 500 registered attendees on September 30, 2020; an international conference on UV-C technologies for air and surface disinfection, December 8–9, 2020; and a webinar on returning to normalcy with the use of UV-C technologies, April 27 and 29, 2021. This article also serves as an introduction to a special section of the Journal of Research of the National Institute of Standards and Technology, where full papers address recent technical, noncommercial, UV-C technology and pathogen-abatement investigations. The set of papers provides keen insights from the vantage points of medicine and industry. Recent technical developments, successes, and needs in optics and photonics, radiation physics, biological efficacy, and the needs of future markets in UV-C technologies are described to provide a concise compilation of the community’s efforts and the state of the field. Standards needs are identified and discussed throughout this special section. This article provides a summary of the essential role of standards for innovation and implementation of UV-C technology for improved patient care and public health.


  • A Snapshot of 118 Solid State Lighting Testing Laboratories’ Capabilities

    by C. Cameron Miller, Hannah Hastings, María E. Nadal

    The National Institute of Standards and Technology (NIST) began to offer proficiency testing for solid state lighting (SSL) products through a Measurement Assurance Program (MAP) in 2010. The MAP program provided proficiency testing complimenting laboratory accreditation to ensure that as SSL products became more prevalent, capable testing laboratories would be available to handle the volume of measurement work. This article communicates the results of the first version of the MAP in which 118 worldwide laboratories participated. The results of the comparison provide a snapshot of the capabilities of accredited laboratories worldwide. Statistical analysis of how the laboratories’ measurements compared to NIST’s measurements for photometric, colorimetric, and electrical quantities and fit parameters for each measurement are presented. In general, all of the laboratory results are within ±4% for total luminous flux and luminous efficacy measurements. The discussion provides reasons for any discrepancies or large uncertainty intervals found in the data. For example, a major finding was that measured differences of Root Mean Square (RMS) current had a larger standard deviation and number of outliers than expected. Two possible explanations are (1) the discrepancies are due to issues with using four-pole sockets and (2) the large deviation is caused by some solid state lamps being sensitive to impedance and slew rate of AC power supplies. Further research in this area is being conducted by NIST to help the testing community reach more consistent measurement results.

  • Fractional retroreflection and observation angularity measurements using imaging technology

    by C. Cameron Miller

    NIST has developed a photometric imaging based method for the measurement of the coefficient of retroreflected luminance. The imaging technology based system simultaneously collects a complete dataset of coefficients of retroreflected luminance (−4° < α < 4°, −π < ρ < π) for a given entrance angle and orientation angle. The advantages include the time required to collect a large number of data points. Over a million data points can be collected in one minute compared to the collection of a thousand data points, which are an incomplete sampling of the retroreflected rho angle and observation angle space, in over 3 hours. The fast measurement of the large number of points allows for a smaller uncertainty for the determination of parameters such as fractional retroreflectance and observation angularity. The direct comparison of the two methods revealed that a larger point-by-point set is required to validate the imaging method.