Robert P. Lucht
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert P. Lucht has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Waruna D. Kulatilaka
Texas A&M University
3 shared publications - James R. Gord
Air Force Research Laboratory
2 shared publications Rodolfo Barron-Jimenez
2 shared publicationsSukesh Roy
Texas A&M University, College Station, TX 77843-3123, USA
2 shared publications- Sukesh Roy
Spectral Energies, LLC
2 shared publications - Thomas N. Anderson
T. N. Andersonand R. P. Lucht are with the School of Mechanical Engineering, 585 Purdue Hall, West Lafayette, Indiana 47907
2 shared publications
Latest Publications
- 1 April 2009
- Published by American Institute of Aeronautics and Astronautics (AIAA) in AIAA Journal
- Vol. 47 (4) , 839-849
Pressure, Temperature and Velocity Measurements in Underexpanded Free Jets using Laser-Induced Fluorescence Imaging
- 1 April 2009
- Published by American Institute of Aeronautics and Astronautics (AIAA) in AIAA Journal
- Vol. 47 (4) , 839-849
Pressure, Temperature and Velocity Measurements in Underexpanded Free Jets using Laser-Induced Fluorescence Imaging
- 1 January 2006
- Published by Optica Publishing Group
- p. ThC3
Diode-Laser-Based Sum and Difference Frequency Generation for High-Speed UV and MIR Absorption Spectroscopy
Sum- and difference-frequency mixing are used to extend the range of high-speed diode-laser-based absorption sensors to ultraviolet and mid-infrared wavelengths. Measurement bandwidths up to 20 kHz are demonstrated in laboratory flames and model combustors.
- 1 January 2006
- Published by Optica Publishing Group
- p. ThC3
Diode-Laser-Based Sum and Difference Frequency Generation for High-Speed UV and MIR Absorption Spectroscopy
Sum- and difference-frequency mixing are used to extend the range of high-speed diode-laser-based absorption sensors to ultraviolet and mid-infrared wavelengths. Measurement bandwidths up to 20 kHz are demonstrated in laboratory flames and model combustors.
- 1 January 2006
- Published by Optica Publishing Group
- p. ThC5
Investigation of Two-Color Laser-Induced Fluorescence (TC-LIF) and Two-Color Six-Wave Mixing Spectroscopy (TC-SWM) for Detection of Atomic Hydrogen
We report picosecond two-color laser-induced fluorescence and six-wave mixing spectroscopy of atomic hydrogen in flames. Effects of the pump-beam polarization on the signals and collisional dynamics of H(2l) level were studied.
- 1 January 2006
- Published by Optica Publishing Group
- p. ThC5
Investigation of Two-Color Laser-Induced Fluorescence (TC-LIF) and Two-Color Six-Wave Mixing Spectroscopy (TC-SWM) for Detection of Atomic Hydrogen
We report picosecond two-color laser-induced fluorescence and six-wave mixing spectroscopy of atomic hydrogen in flames. Effects of the pump-beam polarization on the signals and collisional dynamics of H(2l) level were studied.
- 1 January 2003
- Published by ASME International
- p. 185-190
Diode-Laser-Based Sensor Measurements of Nitric Oxide and Carbon Monoxide in Combustion Exhaust Streams
All-solid-state continuous-wave (cw) laser systems for ultraviolet (UV) absorption measurements of the nitric oxide (NO) molecule and mid-infrared (IR) absorption measurements of carbon monoxide (CO) were developed and demonstrated. For the NO sensor, 250 nW of tunable cw UV radiation at 226.8 nm is produced by sum-frequency-mixing in a beta-barium borate crystal. For the CO sensor, 2μW of tunable cw IR radiation at 4.5 μm is produced by difference-frequency mixing in a periodically-poled lithium niobate crystal. A tunable external-cavity diode laser (ECDL) provides one of the fundamental beams for both processes so that the wavelength of the generated UV/IR can be tuned over NO/CO absorption lines to produce a fully resolved absorption spectrum. The sensors were used for measurements in the exhaust stream of an operating auxiliary power unit (APU) gas turbine engine and a well-stirred reactor (WSR). During these tests, NO was measured in the exhaust at levels below 10 ppm. For measurements at levels above 20 ppm, the NO emission levels obtained using the new sensor agreed with the results of probe sampling chemiluminescent analyzer results to within 10%. A detection limit of 0.8 ppm of per meter path length at 1000 K is estimated for the NO sensor. Measurements with the CO sensor demonstrated an agreement with extractive probe sampling to within 15%. The estimated detection limit of the CO sensor is a few ppm per meter path length at 1000 K.
- 1 January 2003
- Published by ASME International
- p. 185-190
Diode-Laser-Based Sensor Measurements of Nitric Oxide and Carbon Monoxide in Combustion Exhaust Streams
All-solid-state continuous-wave (cw) laser systems for ultraviolet (UV) absorption measurements of the nitric oxide (NO) molecule and mid-infrared (IR) absorption measurements of carbon monoxide (CO) were developed and demonstrated. For the NO sensor, 250 nW of tunable cw UV radiation at 226.8 nm is produced by sum-frequency-mixing in a beta-barium borate crystal. For the CO sensor, 2μW of tunable cw IR radiation at 4.5 μm is produced by difference-frequency mixing in a periodically-poled lithium niobate crystal. A tunable external-cavity diode laser (ECDL) provides one of the fundamental beams for both processes so that the wavelength of the generated UV/IR can be tuned over NO/CO absorption lines to produce a fully resolved absorption spectrum. The sensors were used for measurements in the exhaust stream of an operating auxiliary power unit (APU) gas turbine engine and a well-stirred reactor (WSR). During these tests, NO was measured in the exhaust at levels below 10 ppm. For measurements at levels above 20 ppm, the NO emission levels obtained using the new sensor agreed with the results of probe sampling chemiluminescent analyzer results to within 10%. A detection limit of 0.8 ppm of per meter path length at 1000 K is estimated for the NO sensor. Measurements with the CO sensor demonstrated an agreement with extractive probe sampling to within 15%. The estimated detection limit of the CO sensor is a few ppm per meter path length at 1000 K.
- 31 August 2002
- Published by Elsevier in Combustion and Flame
- Vol. 130 (3) , 261-276
Temperature profile measurements in the near-substrate region of low-pressure diamond-forming flames
- 31 August 2002
- Published by Elsevier in Combustion and Flame
- Vol. 130 (3) , 261-276
Temperature profile measurements in the near-substrate region of low-pressure diamond-forming flames
- 20 November 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (33) , 6005-6011
Interline Transfer CCD Camera for Gated Broadband Coherent Anti-Stokes Raman-Scattering Measurements.
Use of an interline transfer CCD camera for the acquisition of broadband coherent anti-Stokes Raman-scattering (CARS) spectra is demonstrated. The interline transfer CCD has alternating columns of imaging and storage pixels that allow one to acquire two successive images by shifting the first image in the storage pixels and immediately acquiring the second image. We have used this dual-image mode for gated CARS measurements by acquiring a CARS spectral image and shifting it rapidly from the imaging pixel columns to the storage pixel columns. We have demonstrated the use of this dual-image mode for gated single-laser-shot measurement of hydrogen and nitrogen CARS spectra at room temperature and in atmospheric pressure flames. The performance of the interline transfer CCD for these CARS measurements is compared directly with the performance of a back-illuminated unintensified CCD camera.
- 20 November 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (33) , 6005-6011
Interline Transfer CCD Camera for Gated Broadband Coherent Anti-Stokes Raman-Scattering Measurements.
Use of an interline transfer CCD camera for the acquisition of broadband coherent anti-Stokes Raman-scattering (CARS) spectra is demonstrated. The interline transfer CCD has alternating columns of imaging and storage pixels that allow one to acquire two successive images by shifting the first image in the storage pixels and immediately acquiring the second image. We have used this dual-image mode for gated CARS measurements by acquiring a CARS spectral image and shifting it rapidly from the imaging pixel columns to the storage pixel columns. We have demonstrated the use of this dual-image mode for gated single-laser-shot measurement of hydrogen and nitrogen CARS spectra at room temperature and in atmospheric pressure flames. The performance of the interline transfer CCD for these CARS measurements is compared directly with the performance of a back-illuminated unintensified CCD camera.
- 20 November 1999
- Published by Optica Publishing Group in Applied Optics
- Vol. 38 (33) , 6951-6961
Experimental investigation of saturated degenerate four-wave mixing for quantitative concentration measurements
Degenerate four-wave mixing (DFWM) line shapes and signal intensities are measured experimentally in well-characterized hydrogen–air flames operated over a wide range of equivalence ratios. We use both low (perturbative) and high (saturating) beam intensities in the phase-conjugate geometry. Resonances in the A 2Σ+–X 2Π (0,0) band of OH are probed with multiaxial-mode laser radiation. The effects of saturation on the line-center signal intensity and the resonance linewidth are investigated. The DFWM signal intensities are used to measure OH number densities in a series of near-adiabatic flames at equivalence ratios ranging from 0.5 to 1.5. Use of saturating pump intensities minimizes the effects of beam absorption, providing more-accurate number density measurements. The saturated DFWM results are in excellent agreement with OH absorption measurements and equilibrium calculations of OH number density. The polarization dependence of the P 1(2) and R 2(1) resonances is investigated in both laser intensity regimes. There is a significant change in relative reflectivities for different polarization configurations when saturated.
- 20 November 1999
- Published by Optica Publishing Group in Applied Optics
- Vol. 38 (33) , 6951-6961
Experimental investigation of saturated degenerate four-wave mixing for quantitative concentration measurements
Degenerate four-wave mixing (DFWM) line shapes and signal intensities are measured experimentally in well-characterized hydrogen–air flames operated over a wide range of equivalence ratios. We use both low (perturbative) and high (saturating) beam intensities in the phase-conjugate geometry. Resonances in the A 2Σ+–X 2Π (0,0) band of OH are probed with multiaxial-mode laser radiation. The effects of saturation on the line-center signal intensity and the resonance linewidth are investigated. The DFWM signal intensities are used to measure OH number densities in a series of near-adiabatic flames at equivalence ratios ranging from 0.5 to 1.5. Use of saturating pump intensities minimizes the effects of beam absorption, providing more-accurate number density measurements. The saturated DFWM results are in excellent agreement with OH absorption measurements and equilibrium calculations of OH number density. The polarization dependence of the P 1(2) and R 2(1) resonances is investigated in both laser intensity regimes. There is a significant change in relative reflectivities for different polarization configurations when saturated.