SSSteven C. Schallhorn

Steven C. Schallhorn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Steven C. Schallhorn has a total of 46 co-authors. Here are the top co-authors by number of shared publications:

  • David Teenan

    Optical Express, Glasgow, Lanark, Scotland

    9 shared publications
  • David Teenan

    Optical Express, Glasgow, United Kingdom

    8 shared publications
  • Keith A. Hettinger

    Department of Ophthalmology, University of California, San Francisco, California Optical Express, Glasgow, United Kingdom, Carl Zeiss Meditec, Inc., Dublin, California

    8 shared publications
  • Jan A. Venter

    Optical Express, Glasgow, Lanark, Scotland

    7 shared publications
  • Jan Venter

    Optical Express, Glasgow, UK

    6 shared publications
  • Stephen J Hannan

    =0.99), indicating a very predictable refractive correction. The reported AEs were those typically expected after cataract surgery. There were no AEs related to intraoperative manipulation with the IOL/injector or to postoperative stability of the IOL in the capsular bag. No eye lost ≥ 2 lines of CDVA

    6 shared publications

Latest Publications

  • Primary calcification of hydrophilic acrylic lenses in a large population: incidence and outcomes of lens exchange procedures

    by Dimitris Kazakos, Jan A. Venter, Stephen J. Hannan, David Teenan, David R. Cooper, Steven C. Schallhorn, Colin W. Berry, Noelle C. Hannan, Dasi Raju, Julie M. Schallhorn

    Purpose: To assess the incidence of primary opacification and analyze the outcomes of intraocular lens (IOL) exchange procedures. Setting: Private clinics, United Kingdom. Design: Retrospective study. Methods: Electronic charts of all patients implanted with LENTIS lenses between 2010 and 2015 were reviewed, and the incidence of opacification was calculated. The data of patients who developed opacification were compared with those who did not. In eyes requiring IOL exchange due to opacification, visual and refractive outcomes of the last available postexchange visit were analyzed. The analysis was performed separately for eyes with multifocal and monofocal secondary IOLs. Results: 47 171 LENTIS IOLs were implanted of which 2426 (5.1%) opacified. Of the opacified lenses, 1568 (3.3% of the whole cohort) required an IOL exchange. The mean time from primary treatment to opacification diagnosis was 6.9 ± 2.2 years. Patients who developed opacification had a higher prevalence of preoperative myopia. Of all eyes requiring an IOL exchange, the secondary IOL was monofocal in 43.0% and multifocal in 57.0% of eyes. Postexchange corrected visual acuity was 0.00 ± 0.13 logMAR (20/20) in eyes with monofocal secondary IOLs and −0.02 ± 0.08 logMAR (20/20 +1 ) in eyes with multifocal secondary IOLs. The final anatomical position of the secondary IOL was as follows: in-the-bag fixation 67.9%, ciliary sulcus fixation 30.1%, iris-claw fixation 0.6%, and iris suturing or scleral fixation 1.4%. Conclusions: Exchange of opacified IOL was performed safely in most of the patients who developed opacification, including those with prior Nd:YAG capsulotomy, with good visual and refractive outcomes.

  • The incidence and outcomes of intraocular lens exchanges in patients dissatisfied with multifocal lenses: a 15-year retrospective dataset analysis

    by Dimitris Kazakos, Stephen J. Hannan, Jan A. Venter, David Teenan, Huba J. Kiss, Noelle C. Hannan, Colin W. Berry, David R. Cooper, Dasi Raju, Steven C. Schallhorn, et al.

    Purpose: To assess the incidence, clinical outcomes, and adverse event rates of intraocular lens exchange in patients dissatisfied with presbyopia-correcting multifocal IOLs. Setting: Private clinics, United Kingdom Design: Retrospective study Methods: Data of patients who underwent multifocal IOL implantation between 2007 and 2021 and required the exchange of intraocular lenses due to quality of vision issues or insufficient near vision were reviewed. IOL exchanges for other reasons (dislocation, opacification, or other adverse events) were not included in the analysis. Visual and refractive outcomes of the lens exchange procedure were analyzed for the last available follow-up. Results: The mean time from the primary procedure to the IOL exchange was 13.6±8.3 months. The total IOL exchange rate was 0.63% (688 of 109,274 lenses). Of these, 637 exchanges (0.58%) were performed due to quality of vision issues, and 51 (0.05%) were exchanged primarily due to insufficient near vision (e.g., IOL with lower near addition exchanged for an IOL with stronger near addition). Post IOL exchange, 71.7% (493/688) and 91.3% (628/688) were within 0.50D and 1.00D of emmetropia, respectively. The mean post-exchange uncorrected distance visual acuity was 0.11±0.21 logMAR (20/25 -0.5 ). The anatomical position of the secondary IOL was as follows: in-the-bag fixation 86.8% (597/688), ciliary sulcus fixation 12.5% (86/688), and alternative fixation (iris claw, scleral fixation, or IOL suturing) was used in 0.7% of cases (5/688). Conclusion: Patients requiring an IOL exchange due to dissatisfaction with multifocal lenses achieved favorable refractive and visual outcomes. In-the-bag implantation of secondary IOL was possible in most cases.


  • Open Access

    Preliminary Evaluation of Clinical and Non-Clinical Outcome Metrics in Patient Satisfaction After Implantation of a Non-Constant Aberration-Correcting Monofocal IOL

    by Steven C Schallhorn, David Teenan, Jan Venter, Julie M Schallhorn, Stephen J Hannan

    Purpose: To evaluate patient-reported outcomes after implantation of a non-constant aberration-correcting monofocal IOL and explore factors affecting postoperative satisfaction with vision. Methods: This retrospective study comprised patients who underwent cataract surgery with bilateral implantation of CT LUCIA 621P IOL (Carl Zeiss Meditec AG, Jena, Germany). Factors affecting postoperative satisfaction with vision were evaluated, including patient demographics, clinical and non-clinical variables (visual acuities, adverse events, ocular comorbidities, general health, depression scores, personality types), and other patient-reported outcomes (visual phenomena, dry eye). Questionnaires were used to assess patient-reported visual outcomes, depression, and personality types. The outcomes of the last available clinical visit were evaluated. Results: A total of 97 patients were included, of whom 63.9% reported to be very satisfied and 30.9% were satisfied with postoperative vision. Only three patients were dissatisfied, and the reasons were mostly related to their postoperative clinical findings. In a multivariate logistic regression analysis, the patient’s age and postoperative uncorrected visual acuity were significant predictors of postoperative satisfaction. Some non-clinical and clinical variables were signaling potential trends in satisfaction, but a larger cohort of patients would be required to explore them. Conclusion: Satisfaction of cataract patients implanted with a monofocal IOL remains high. When evaluating postoperative satisfaction, non-clinical factors and interactions with other patient-reported outcomes (visual phenomena or dry eye) should not be underestimated.


  • Prediction of visual outcomes using virtual implantation of a trifocal intraocular lens in presbyopic lens exchange patients

    by Steven C. Schallhorn, Joaquín Fernández, Hakan Kaymak, Mario Dipl.-Ing. (Fh) Gerlach, Friedrich O. Kirchner

    Purpose: To assess the reliability of a new virtual intraocular lens (IOL) implantation device to predict the outcomes of a trifocal IOL. Setting: Clinical sites in Spain and Germany. Design: Prospective multicenter study. Methods: Preoperative measurements obtained by the virtual implantation of AT LISA tri 839MP IOL with Virtual IOL (VirtIOL) device were compared with postoperative (month 3) outcomes after the IOL implantation. The evaluated metrics were defocus curve, contrast sensitivity (CS) (both in photopic conditions), and visual phenomena (visual angle size of burst and annular pattern) in mesopic conditions. Results: 45 presbyopic noncataract patients (mean age 56.16 ± 5.03 years) were included in this study. The VirtIOL device reasonably predicted the shape of the defocus curve, especially in the intermediate vision range, but underestimated postoperative visual acuities (VAs) mainly at the defocus range between +1.0 diopters (D) and −3.5 D. The difference between predicted and achieved VA was −0.11 ± 0.13 logMAR (P < .001) for 0.0 D defocus and −0.16 ± 0.15 D logMAR (P < .001) for −2.50 D defocus. The shape of the CS curve was almost identical for predicted and achieved measurements, but the device underestimated the values by ≈0.3 logCS units for each spatial frequency. Visual phenomena were similar between the predicted and achieved outcome (predicted vs achieved: burst pattern 2.65 ± 0.97 degrees vs 2.74 ± 0.95 degrees, P = .63; annular pattern: 0.88 ± 0.42 degrees vs 0.93 ± 0.49 degrees, P = .59). Conclusions: The device reasonably predicted the pattern of measured variables. VA/CS reduction might be attributed to viewing the objects through a more complex optical system and would need to be accounted for in clinical studies.


  • Effect of residual sphere on uncorrected visual acuity and satisfaction in patients with monofocal and multifocal intraocular lenses

    by Steven C. Schallhorn, Keith A. Hettinger, Stephen J. Od Hannan, Jan A. Venter, David Teenan, Julie M. Schallhorn

    Purpose: To assess the effect of residual sphere on vision and satisfaction in pseudophakic patients. Setting: Private clinics, United Kingdom. Design: Retrospective case series. Methods: A multivariate model evaluated the effect of 1-month residual sphere on outcomes of pseudophakic patients. Odds ratios (ORs) were calculated to assess the relative risk of not achieving ≥20/20 monocular uncorrected distance visual acuity (UDVA), ≥20/50 uncorrected near visual acuity (UNVA), and not being satisfied with vision. ORs were assessed for residual sphere −1.00 to +1.00 diopter (D) in quarter-diopter steps, using 0.00 D as a reference. Results: The analysis included 38 828 multifocal and 11 571 monofocal intraocular lenses (IOLs). The residual myopic sphere ≤−0.25 D and hyperopic sphere ≥+0.50 D had a clinically meaningful effect on UDVA. Although monofocal IOLs had an improvement in UNVA with every additional 0.25 D of myopia, the change in ORs with increasing myopia was not significant for multifocal IOLs. The mean improvement in UNVA comparing eyes with 0.00 D and −1.00 D sphere was 0.26 logMAR for monofocal and 0.03 logMAR for multifocal IOLs. Low near-addition IOLs had a slightly higher gain in UNVA with increasing myopia, but the gain was not as substantial as with monofocal IOLs. The effect of ametropia on satisfaction was more pronounced for multifocal IOLs. For every 0.25 D of residual myopia, there was >25% increase in dissatisfied patients. Conclusions: Although myopia improved UNVA in eyes with monofocal IOL, multifocal IOLs did not benefit from residual myopia. Multifocal IOL patients desiring distance vision should be targeted closest to emmetropia, even if it means targeting slight hyperopia.


  • Photorefractive Keratectomy in Student Naval Aviators: Outcomes of the U.S. Navy Accessioning Study

    by Steven C. Schallhorn, Mitchell C. Brown, David J. Tanzer

    PURPOSE: To present the outcomes of the U.S. Navy pho- torefractive keratectomy (PRK) accessioning study conducted between 2000 and 2005 that helped lead to the acceptance of laser vision correction within the U.S. aviation industry. METHODS: In this prospective masked study, a total of 301 students who had PRK and underwent naval flight training were compared to 4,368 untreated peers. Three training pipe- lines were compared: propeller/jet transport, jet fighters, and helicopters. The evaluated metrics were flight and academic performance (assessed for the primary and advanced stage of the training as normalized Navy Standard Score [NSS]), as well as the student attrition rate from training. RESULTS: The attrition rate was lower in the PRK group compared to controls (15.9% vs 23.2%; P = .004). In the primary stage of training, students who had PRK outperformed controls in flight training performance in the propeller/jet transport pipeline (average NSS after PRK: 52.4 +/- 7.5 vs con- trols: 50.7 +/- 6.4, P = .02), but the flight performance in the jet fighter and helicopter pipelines was comparable between the two groups. Academic performance in the primary stage of training was approximately 7% to 13% higher in students who had PRK for all training pipelines. During the advanced training stage, there was no difference in the flight perfor- mance between the groups in any of the presented pipelines. Academic performance was significantly better for students who had PRK in the helicopter pipeline (51.2 +/- 11.0 vs 46.7 +/- 11.7 P < .001) but comparable between the two groups in the remaining pipelines. CONCLUSIONS: Refractive surgery did not have adverse effects on flight performance metrics. Pilots who had PRK had comparable or better outcomes than their untreated peers.


  • Open Access

    Early Clinical Experience with a New Hydrophobic Acrylic Single-Piece Monofocal Intraocular Lens

    by Steven C Schallhorn, David Teenan, Jan Venter, Julie M Schallhorn, Stephen J Hannan

    Purpose: To evaluate early clinical outcomes and adverse events (AEs) in cataract patients following implantation of a monofocal hydrophobic acrylic IOL with a new optimized non-constant aberration-correcting design (CT LUCIA 621P). Methods: This retrospective study included patients with visually significant cataracts who underwent implantation of the CT LUCIA 621P IOL. Refraction, corrected (CDVA) and uncorrected (UDVA) visual acuity of the last available visit were used in the analysis. Intraoperative and postoperative AEs of the cohort were reviewed. Results: A total of 191 eyes of 133 patients with the mean age of 70.2± 11.2 years were included in this study. The mean follow-up time of the last available visit was 1.7± 1.3 months. The mean postoperative monocular UDVA was 0.09± 0.16 logMAR (≈20/25), and 74.9% (143/191) eyes achieved ≥ 20/25 UDVA. The percentage of eyes with manifest spherical equivalent (MSE) within ± 0.50D and ± 1.00D of emmetropia was 84.8% (162/191) and 98.4% (188/191), respectively. Linear regression of attempted vs achieved MSE showed a tight relationship, with the coefficient of determination close to 1 (R2=0.99), indicating a very predictable refractive correction. The reported AEs were those typically expected after cataract surgery. There were no AEs related to intraoperative manipulation with the IOL/injector or to postoperative stability of the IOL in the capsular bag. No eye lost ≥ 2 lines of CDVA. Conclusion: The implantation of CT LUCIA 621P resulted in good refractive predictability and visual outcomes. No IOL-related adverse events were reported.


  • Open Access

    Outcomes of a multicenter U.S. clinical trial of a new monofocal single-piece hydrophobic acrylic IOL

    by Steven C. Schallhorn, Michael Bonilla, Seth M. Pantanelli

    Purpose: To evaluate the safety and effectiveness of the CT LUCIA 611P intraocular lens (IOL) in patients with cataracts. Setting: 23 surgeons at 15 different clinical sites. Design: Prospective single-arm clinical trial. Methods: The study was conducted under an Investigational Device Exemption for premarket approval of a new hydrophobic acrylic IOL in the United States. Patients were followed for 12 months, and the main measured variables included uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, and adverse events. Results: In total, 339 eyes of 339 patients were implanted with the study device, of which 310 (91.4%) reached the 12-month visit. The percentage of eyes within ±0.50 diopter (D) and ±1.00 D of emmetropia was 85.8% (266/310) and 96.8% (300/310), respectively. Manifest refraction spherical equivalent (MRSE) remained stable over the first year with the mean 12-month MRSE of −0.03 ± 0.45 D. The mean 12-month UDVA and CDVA were 0.09 ± 0.15 (≈20/25) and −0.02 ± 0.09 (≈20/19) logMAR, respectively. Of all patients, 99.4% (308/310) achieved postoperative CDVA ≥20/40. The incidence of Nd:YAG capsulotomy within the first year was 3.5% (11/310). Only 2 eyes had IOL tilt present at the 12-month postoperative visit with no associated visual symptoms. There were 2 cases of IOL decentration; one required removal of the IOL, whereas the other had no visual side effects related to decentration. There were no findings of glistening at any visit. Conclusions: The CT LUCIA 611P IOL demonstrated excellent safety, efficacy, and stability of refractive outcomes. No significant issues related to the biocompatibility of the IOL material were observed.


  • Open Access

    Reply: Effect of residual astigmatism on uncorrected visual acuity and patient satisfaction in pseudophakic patients.

    by Steven C. Schallhorn, Keith A. Hettinger, Martina Msc Pelouskova, David Teenan, Jan A. Venter, Stephen J. Od Hannan, Julie M. Schallhorn