Jeffrey Parks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jeffrey Parks has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Marc A. Edwards
Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
4 shared publications Marc Edwards
Department of Civil and Environmental Engineering, 1145 Perry Street, Virginia Tech, Durham Hall 418, Blacksburg, VA 24061
3 shared publications- Adrienne Katner
Louisiana State University Health Sciences Center New Orleans
2 shared publications Laurie McNeill
Utah State University, USA
2 shared publications- Abhijeet Dudi
Research Scientist, Dept. of Civil and Environmental Engineering, Virginia Tech, 418 Durham Hall, Blacksburg, VA 24061
1 shared publication Ali Haghani
1 shared publication
Latest Publications
- Open Access
- 20 July 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (7) , 1537
Effectiveness of Prevailing Flush Guidelines to Prevent Exposure to Lead in Tap Water
Flushing tap water is promoted as a low cost approach to reducing water lead exposures. This study evaluated lead reduction when prevailing flush guidelines (30 s–2 min) are implemented in a city compliant with lead-associated water regulations (New Orleans, LA, USA). Water samples (n = 1497) collected from a convenience sample of 376 residential sites (2015–2017) were analyzed for lead. Samples were collected at (1) first draw (n = 375) and after incremental flushes of (2) 30–45 s (n = 375); (3) 2.5–3 min (n = 373), and (4) 5.5–6 min (n = 218). There was a small but significant increase in water lead after the 30 s flush (vs. first draw lead). There was no significant lead reduction until the 6 min flush (p < 0.05); but of these samples, 52% still had detectable lead (≥1 ppb). Older homes (pre-1950) and low occupancy sites had significantly higher water lead (p < 0.05). Each sample type had health-based standard exceedances in over 50% of sites sampled (max: 58 ppb). While flushing may be an effective short-term approach to remediate high lead, prevailing flush recommendations are an inconsistently effective exposure prevention measure that may inadvertently increase exposures. Public health messages should be modified to ensure appropriate application of flushing, while acknowledging its short-comings and practical limitations.
- 20 July 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (7) , 1537
Open AccessEffectiveness of Prevailing Flush Guidelines to Prevent Exposure to Lead in Tap Water
Flushing tap water is promoted as a low cost approach to reducing water lead exposures. This study evaluated lead reduction when prevailing flush guidelines (30 s–2 min) are implemented in a city compliant with lead-associated water regulations (New Orleans, LA, USA). Water samples (n = 1497) collected from a convenience sample of 376 residential sites (2015–2017) were analyzed for lead. Samples were collected at (1) first draw (n = 375) and after incremental flushes of (2) 30–45 s (n = 375); (3) 2.5–3 min (n = 373), and (4) 5.5–6 min (n = 218). There was a small but significant increase in water lead after the 30 s flush (vs. first draw lead). There was no significant lead reduction until the 6 min flush (p < 0.05); but of these samples, 52% still had detectable lead (≥1 ppb). Older homes (pre-1950) and low occupancy sites had significantly higher water lead (p < 0.05). Each sample type had health-based standard exceedances in over 50% of sites sampled (max: 58 ppb). While flushing may be an effective short-term approach to remediate high lead, prevailing flush recommendations are an inconsistently effective exposure prevention measure that may inadvertently increase exposures. Public health messages should be modified to ensure appropriate application of flushing, while acknowledging its short-comings and practical limitations.
- 2 June 2018
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 74 (8) , 914-917
Potential Challenges Meeting the American Academy of Pediatrics’ Lead in School Drinking Water Goal of 1 μg/L
Concern about lead in drinking water has heightened since the Flint water crisis. Moreover, recent medical evidence increasingly shows damage to children’s health at levels of lead exposure once considered low. In order to better protect children from these hazards, the American Academy of Pediatrics (AAP) recommends that drinking water in public schools does not exceed 1 μg/L lead. Meeting this goal with current plumbing and fixtures will be challenging, because current “lead-free” standards did not anticipate targets this low. Three styles of recently manufactured “lead-free” faucets were tested and average lead leaching ranged from 1.5 μg/L to 3.0 μg/L after 19 d. Given that the NSF/ANSI 61 test water is less aggressive than some potable waters, even newly manufactured “lead-free” faucets may not meet the standards recommended by AAP.
- 2 June 2018
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 74 (8) , 914-917
Potential Challenges Meeting the American Academy of Pediatrics’ Lead in School Drinking Water Goal of 1 μg/L
Concern about lead in drinking water has heightened since the Flint water crisis. Moreover, recent medical evidence increasingly shows damage to children’s health at levels of lead exposure once considered low. In order to better protect children from these hazards, the American Academy of Pediatrics (AAP) recommends that drinking water in public schools does not exceed 1 μg/L lead. Meeting this goal with current plumbing and fixtures will be challenging, because current “lead-free” standards did not anticipate targets this low. Three styles of recently manufactured “lead-free” faucets were tested and average lead leaching ranged from 1.5 μg/L to 3.0 μg/L after 19 d. Given that the NSF/ANSI 61 test water is less aggressive than some potable waters, even newly manufactured “lead-free” faucets may not meet the standards recommended by AAP.
- 13 May 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 114-120
Evaluating Leachability of Residual Solids from Hydraulic Fracturing in the Marcellus Shale
The purpose of this research is to characterize residual solids from hydraulic fracturing in the Marcellus Shale to predict leaching behavior in the natural environment for elements of concern. Solid samples were subjected to strong acid digestion to determine: (1) the total environmentally available concentration of elements and to weak acid digestions with various extraction fluids (reagent water, inorganic acid, organic acid, and synthetic municipal landfill leachate) , and (2) worst-case leaching potential in various disposal environments. Comparing these results, it is possible to determine the effect of extraction fluid and sample characteristics on the leaching potential of select elements. This may be further developed to determine best management practices for the disposal of hydraulic fracturing residual solids.
- 13 May 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 114-120
Evaluating Leachability of Residual Solids from Hydraulic Fracturing in the Marcellus Shale
The purpose of this research is to characterize residual solids from hydraulic fracturing in the Marcellus Shale to predict leaching behavior in the natural environment for elements of concern. Solid samples were subjected to strong acid digestion to determine: (1) the total environmentally available concentration of elements and to weak acid digestions with various extraction fluids (reagent water, inorganic acid, organic acid, and synthetic municipal landfill leachate) , and (2) worst-case leaching potential in various disposal environments. Comparing these results, it is possible to determine the effect of extraction fluid and sample characteristics on the leaching potential of select elements. This may be further developed to determine best management practices for the disposal of hydraulic fracturing residual solids.
- 1 May 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 22 (5) , 515-524
Effects of Bulk Water Chemistry on Autogenous Healing of Concrete
Autogenous healing can occur when hairline cracks in concrete repair themselves through reactions with water and/or constituents in water. The chemistry of water contacting the cement affects whether the crack heals autogenously or propagates until leaks occur. The strength testing on concrete specimens demonstrates that appreciable healing can occur at a pH of 9.5 when there is sufficient magnesium and silicon in the water. Scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS) analyses indicate that a magnesium silicate material is present within the crack surfaces when higher strength healing has occurred. Calcium does not appear to promote the sealing of cracks. A carbonation of internal concrete surfaces was not detected when cracks were sealed via autogenous healing. Chloride diffusion rates do not return to levels seen in virgin concrete when cracks are autogenously healed. However, the water permeability and chloride diffusion are impeded by any filling of cracks regardless of ...
- 1 May 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 22 (5) , 515-524
Effects of Bulk Water Chemistry on Autogenous Healing of Concrete
Autogenous healing can occur when hairline cracks in concrete repair themselves through reactions with water and/or constituents in water. The chemistry of water contacting the cement affects whether the crack heals autogenously or propagates until leaks occur. The strength testing on concrete specimens demonstrates that appreciable healing can occur at a pH of 9.5 when there is sufficient magnesium and silicon in the water. Scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS) analyses indicate that a magnesium silicate material is present within the crack surfaces when higher strength healing has occurred. Calcium does not appear to promote the sealing of cracks. A carbonation of internal concrete surfaces was not detected when cracks were sealed via autogenous healing. Chloride diffusion rates do not return to levels seen in virgin concrete when cracks are autogenously healed. However, the water permeability and chloride diffusion are impeded by any filling of cracks regardless of ...
- 1 February 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 133 (2) , 149-156
Boron Removal via Formation of Magnesium Silicate Solids during Precipitative Softening
Precipitative softening is an option to remove silicon and boron from natural waters. Silicon was removed from hard waters by precipitative softening when the molar ratio of Mg:Si was less than 6:1 by the formation of an amorphous magnesium silicate. This solid had an apparent solubility product constant of 10−25.66 and was stoichiometrically similar to the mineral forsterite, Mg2 Si O4 . Boron removal was consistent with sorption to this amorphous magnesium silicate and could be roughly described by a Freundlich isotherm: Bsorb ∕ Mg2 Si O4 (s) =21× Bsol0.51 .
- 1 February 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 133 (2) , 149-156
Boron Removal via Formation of Magnesium Silicate Solids during Precipitative Softening
Precipitative softening is an option to remove silicon and boron from natural waters. Silicon was removed from hard waters by precipitative softening when the molar ratio of Mg:Si was less than 6:1 by the formation of an amorphous magnesium silicate. This solid had an apparent solubility product constant of 10−25.66 and was stoichiometrically similar to the mineral forsterite, Mg2 Si O4 . Boron removal was consistent with sorption to this amorphous magnesium silicate and could be roughly described by a Freundlich isotherm: Bsorb ∕ Mg2 Si O4 (s) =21× Bsol0.51 .
- 1 May 2006
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 132 (5) , 489-496
Precipitative Removal of As, Ba, B, Cr, Sr, and V Using Sodium Carbonate
Sodium carbonate softening at pH 10.3 is a viable method of removing the inorganic contaminants arsenic, barium, chromium, strontium, and vanadium from drinking water sources. A broad survey revealed that removals varied widely and were dependent on solution composition. Median removals of As, Ba, Cr, Sr, and V were 24, 100, 92, 99, and 60%, respectively. Linear and nonlinear empirical models were fit for crudely estimating the removal of these contaminants in the presence of other elements that are typically removed in the softening process (i.e., calcium, magnesium, silicon, iron, and aluminum). Boron was removed to a much lesser extent (median removal 2%) indicating soda ash softening is not a promising treatment option for this purpose.
- 1 May 2006
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 132 (5) , 489-496
Precipitative Removal of As, Ba, B, Cr, Sr, and V Using Sodium Carbonate
Sodium carbonate softening at pH 10.3 is a viable method of removing the inorganic contaminants arsenic, barium, chromium, strontium, and vanadium from drinking water sources. A broad survey revealed that removals varied widely and were dependent on solution composition. Median removals of As, Ba, Cr, Sr, and V were 24, 100, 92, 99, and 60%, respectively. Linear and nonlinear empirical models were fit for crudely estimating the removal of these contaminants in the presence of other elements that are typically removed in the softening process (i.e., calcium, magnesium, silicon, iron, and aluminum). Boron was removed to a much lesser extent (median removal 2%) indicating soda ash softening is not a promising treatment option for this purpose.
- 1 July 2004
- Published by Elsevier in Water Research
- Vol. 38 (12) , 2827-2838
Determination of total chromium in environmental water samples
- 1 July 2004
- Published by Elsevier in Water Research
- Vol. 38 (12) , 2827-2838
Determination of total chromium in environmental water samples