Neil Gelman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Neil Gelman has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Anat Kornecki
St. Joseph’s Health Care London, Western University, ON, Canada
4 shared publications - Brian Yaremko
Department of Oncology, Western University, London, Ontario, Canada
4 shared publications - Frank S. Prato
Imaging Program, Lawson Health Research Institute, London, ON N6A 4V2, Canada
4 shared publications - Michael Lock
London Health Sciences Centre, Schulich School of Medicine & Dentistry, University of Western Ontario, London, ON N6A 5W9, Canada
4 shared publications - Muriel Brackstone
Department of Surgery, Western University, London, ON N6A 4V2, Canada
4 shared publications - Robert Terry Thompson
Medical Biophysics, Western University, London, Canada; Lawson Health Research Institute, London, Canada
4 shared publications
Latest Publications
- Open Access
Determining Optimal Fractionation of Neoadjuvant Radiation in Low-Risk, Early-Stage Breast Cancer—Randomized SIGNAL Clinical Trial
Background: Neoadjuvant partial breast irradiation using stereotactic body radiotherapy (SBRT) has emerged as a strategy to induce tumor and immune responses in early-stage, low-risk breast cancer. While prior studies have demonstrated encouraging response rates and evidence of immune modulation, the optimal radiotherapy regimen for immune priming remains unclear. SIGNAL 2.0 is a randomized phase II trial designed to compare the biological and immunological impact of a single-fraction versus three-fraction neoadjuvant SBRT. Materials and Methods: Sixty-one postmenopausal patients ≥ 50 years with unifocal, hormone positive, node-negative invasive ductal carcinoma < 3 cm were randomized 1:1 to receive either 21 Gy in one fraction or 30 Gy in three fractions, delivered to the tumor in the prone position. Core biopsies were collected pre-SBRT and 14–20 days post-SBRT at the time of surgery. Immune markers were assessed using tumor-infiltrating lymphocyte (TIL) scoring, NanoString nCounter PanCancer Immune Profiling, and NanoString GeoMx Digital Spatial Profiling (DSP). Results: Available tumor samples from 47 patients underwent paired tissue analysis. Three-fraction SBRT induced 200 differentially expressed genes, including enrichment of pathways related to adaptive immune activation, with significant increases in expression levels of macrophages, dendritic cells, neutrophils and CD8 T-cells. Proteomic profiling also identified a significant increase in the expression levels of neutrophils, Treg cells, macrophages, and NK cells in the tumor microenvironment of the samples from patients receiving the three-fraction regimen. Conclusions: Neoadjuvant SBRT induces measurable immune activation, with three-fraction regimens generating more extensive transcriptional, proteomic, and cellular immune changes than a single fraction. Three-fraction neoadjuvant SBRT may provide superior immune priming, providing a foundation for future trials integrating neoadjuvant radiotherapy with immunomodulatory therapies.
Open AccessDetermining Optimal Fractionation of Neoadjuvant Radiation in Low-Risk, Early-Stage Breast Cancer—Randomized SIGNAL Clinical Trial
Background: Neoadjuvant partial breast irradiation using stereotactic body radiotherapy (SBRT) has emerged as a strategy to induce tumor and immune responses in early-stage, low-risk breast cancer. While prior studies have demonstrated encouraging response rates and evidence of immune modulation, the optimal radiotherapy regimen for immune priming remains unclear. SIGNAL 2.0 is a randomized phase II trial designed to compare the biological and immunological impact of a single-fraction versus three-fraction neoadjuvant SBRT. Materials and Methods: Sixty-one postmenopausal patients ≥ 50 years with unifocal, hormone positive, node-negative invasive ductal carcinoma < 3 cm were randomized 1:1 to receive either 21 Gy in one fraction or 30 Gy in three fractions, delivered to the tumor in the prone position. Core biopsies were collected pre-SBRT and 14–20 days post-SBRT at the time of surgery. Immune markers were assessed using tumor-infiltrating lymphocyte (TIL) scoring, NanoString nCounter PanCancer Immune Profiling, and NanoString GeoMx Digital Spatial Profiling (DSP). Results: Available tumor samples from 47 patients underwent paired tissue analysis. Three-fraction SBRT induced 200 differentially expressed genes, including enrichment of pathways related to adaptive immune activation, with significant increases in expression levels of macrophages, dendritic cells, neutrophils and CD8 T-cells. Proteomic profiling also identified a significant increase in the expression levels of neutrophils, Treg cells, macrophages, and NK cells in the tumor microenvironment of the samples from patients receiving the three-fraction regimen. Conclusions: Neoadjuvant SBRT induces measurable immune activation, with three-fraction regimens generating more extensive transcriptional, proteomic, and cellular immune changes than a single fraction. Three-fraction neoadjuvant SBRT may provide superior immune priming, providing a foundation for future trials integrating neoadjuvant radiotherapy with immunomodulatory therapies.
- Open Access
- 17 February 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (4) , 4036
Monocyte MRI Relaxation Rates Are Regulated by Extracellular Iron and Hepcidin
Many chronic inflammatory conditions are mediated by an increase in the number of monocytes in peripheral circulation, differentiation of monocytes to macrophages, and different macrophage subpopulations during pro- and anti-inflammatory stages of tissue injury. When hepcidin secretion is stimulated during inflammation, the iron export protein ferroportin is targeted for degradation on a limited number of cell types, including monocytes and macrophages. Such changes in monocyte iron metabolism raise the possibility of non-invasively tracking the activity of these immune cells using magnetic resonance imaging (MRI). We hypothesized that hepcidin-mediated changes in monocyte iron regulation influence both cellular iron content and MRI relaxation rates. In response to varying conditions of extracellular iron supplementation, ferroportin protein levels in human THP-1 monocytes decreased two- to eightfold, consistent with paracrine/autocrine regulation of iron export. Following hepcidin treatment, ferroportin protein levels further decreased two- to fourfold. This was accompanied by an approximately twofold increase in total transverse relaxation rate, R2*, compared to non-supplemented cells. A positive correlation between total cellular iron content and R2* improved from moderate to strong in the presence of hepcidin. These findings suggest that hepcidin-mediated changes detected in monocytes using MRI could be valuable for in vivo cell tracking of inflammatory responses.
- 17 February 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (4) , 4036
Open AccessMonocyte MRI Relaxation Rates Are Regulated by Extracellular Iron and Hepcidin
Many chronic inflammatory conditions are mediated by an increase in the number of monocytes in peripheral circulation, differentiation of monocytes to macrophages, and different macrophage subpopulations during pro- and anti-inflammatory stages of tissue injury. When hepcidin secretion is stimulated during inflammation, the iron export protein ferroportin is targeted for degradation on a limited number of cell types, including monocytes and macrophages. Such changes in monocyte iron metabolism raise the possibility of non-invasively tracking the activity of these immune cells using magnetic resonance imaging (MRI). We hypothesized that hepcidin-mediated changes in monocyte iron regulation influence both cellular iron content and MRI relaxation rates. In response to varying conditions of extracellular iron supplementation, ferroportin protein levels in human THP-1 monocytes decreased two- to eightfold, consistent with paracrine/autocrine regulation of iron export. Following hepcidin treatment, ferroportin protein levels further decreased two- to fourfold. This was accompanied by an approximately twofold increase in total transverse relaxation rate, R2*, compared to non-supplemented cells. A positive correlation between total cellular iron content and R2* improved from moderate to strong in the presence of hepcidin. These findings suggest that hepcidin-mediated changes detected in monocytes using MRI could be valuable for in vivo cell tracking of inflammatory responses.
- 19 November 2015
- Published by Springer Nature in Journal of Radiation Oncology
- Vol. 4 (4) , 423-430
A phase II trial to evaluate single-dose stereotactic body radiation therapy (SBRT) prior to surgery for early-stage breast carcinoma: SIGNAL (stereotactic image-guided neoadjuvant ablative radiation then lumpectomy) trial
- 19 November 2015
- Published by Springer Nature in Journal of Radiation Oncology
- Vol. 4 (4) , 423-430
A phase II trial to evaluate single-dose stereotactic body radiation therapy (SBRT) prior to surgery for early-stage breast carcinoma: SIGNAL (stereotactic image-guided neoadjuvant ablative radiation then lumpectomy) trial
- 1 June 2014
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 32 (5) , 590-593
A hybrid strategy for correcting geometric distortion in echo-planar images
- 1 June 2014
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 32 (5) , 590-593
A hybrid strategy for correcting geometric distortion in echo-planar images
- Open Access
- 5 February 2014
- Published by Frontiers Media SA in Frontiers in Microbiology
- Vol. 5, 29
Biophysical features of MagA expression in mammalian cells: implications for MRI contrast
We compared overexpression of the magnetotactic bacterial gene MagA with the modified mammalian ferritin genes HF+LF, in which both heavy and light subunits lack iron response elements. Whereas both expression systems have been proposed for use in non-invasive, magnetic resonance (MR) reporter gene expression, limited information is available regarding their relative potential for providing gene-based contrast. Measurements of MR relaxation rates in these expression systems are important for optimizing cell detection and specificity, for developing quantification methods, and for refinement of gene-based iron contrast using magnetosome associated genes. We measured the total transverse relaxation rate (R2*), its irreversible and reversible components (R2 and R2′, respectively) and the longitudinal relaxation rate (R1) in MDA-MB-435 tumor cells. Clonal lines overexpressing MagA and HF+LF were cultured in the presence and absence of iron supplementation, and mounted in a spherical phantom for relaxation mapping at 3 Tesla. In addition to MR measures, cellular changes in iron and zinc were evaluated by inductively-coupled plasma mass spectrometry, in ATP by luciferase bioluminescence and in transferrin receptor by Western blot. Only transverse relaxation rates were significantly higher in iron-supplemented, MagA- and HF+LF-expressing cells compared to non-supplemented cells and the parental control. R2* provided the greatest absolute difference and R2′ showed the greatest relative difference, consistent with the notion that R2′ may be a more specific indicator of iron-based contrast than R2, as observed in brain tissue. Iron supplementation of MagA- and HF+LF-expressing cells increased the iron/zinc ratio approximately 20-fold, while transferrin receptor expression decreased approx. 10-fold. Level of ATP was similar across all cell types and culture conditions. These results highlight the potential of magnetotactic bacterial gene expression for improving MR contrast.
- 5 February 2014
- Published by Frontiers Media SA in Frontiers in Microbiology
- Vol. 5, 29
Open AccessBiophysical features of MagA expression in mammalian cells: implications for MRI contrast
We compared overexpression of the magnetotactic bacterial gene MagA with the modified mammalian ferritin genes HF+LF, in which both heavy and light subunits lack iron response elements. Whereas both expression systems have been proposed for use in non-invasive, magnetic resonance (MR) reporter gene expression, limited information is available regarding their relative potential for providing gene-based contrast. Measurements of MR relaxation rates in these expression systems are important for optimizing cell detection and specificity, for developing quantification methods, and for refinement of gene-based iron contrast using magnetosome associated genes. We measured the total transverse relaxation rate (R2*), its irreversible and reversible components (R2 and R2′, respectively) and the longitudinal relaxation rate (R1) in MDA-MB-435 tumor cells. Clonal lines overexpressing MagA and HF+LF were cultured in the presence and absence of iron supplementation, and mounted in a spherical phantom for relaxation mapping at 3 Tesla. In addition to MR measures, cellular changes in iron and zinc were evaluated by inductively-coupled plasma mass spectrometry, in ATP by luciferase bioluminescence and in transferrin receptor by Western blot. Only transverse relaxation rates were significantly higher in iron-supplemented, MagA- and HF+LF-expressing cells compared to non-supplemented cells and the parental control. R2* provided the greatest absolute difference and R2′ showed the greatest relative difference, consistent with the notion that R2′ may be a more specific indicator of iron-based contrast than R2, as observed in brain tissue. Iron supplementation of MagA- and HF+LF-expressing cells increased the iron/zinc ratio approximately 20-fold, while transferrin receptor expression decreased approx. 10-fold. Level of ATP was similar across all cell types and culture conditions. These results highlight the potential of magnetotactic bacterial gene expression for improving MR contrast.
- 30 June 2011
- Published by Elsevier in Academic Radiology
- Vol. 18 (6) , 694-704
Optimization of Time-to-peak Analysis for Differentiating Malignant and Benign Breast Lesions with Dynamic Contrast-Enhanced MRI
- 30 June 2011
- Published by Elsevier in Academic Radiology
- Vol. 18 (6) , 694-704
Optimization of Time-to-peak Analysis for Differentiating Malignant and Benign Breast Lesions with Dynamic Contrast-Enhanced MRI
- Open Access
- 21 April 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 59 (5) , 1190-1196
High‐contrast 3D neonatal brain imaging with combined T1‐ and T2‐weighted MP‐RAGE
Optimization of magnetization-prepared rapid gradient-echo (MP-RAGE) sequence variations for maximum white matter (WM) versus gray matter (GM) contrast in neonates at 3T was investigated. Numerical simulations were applied to optimize and compare three contrast preparation modules and to assess the effect of phase encoding (PE) order on contrast between WM and thin cortical GM layers. Simulations predict that a new sequence, which combines both T1- and T2-weighting into the contrast preparation and utilizes an interleaved elliptical-spiral PE order, should provide the strongest contrast between neonatal WM and cortical GM. This sequence was compared to a conventional MP-RAGE acquisition (i.e., T1-weighted preparation, centric PE order) for in vivo imaging of seven preterm newborn infants. Regional measurements of the contrast-to-noise ratio (CNR) between WM and GM demonstrated an increase of 50–70% (depending on GM region) using the new sequence, in good agreement with theoretical predictions. This improved contrast resulted in superior WM versus GM discrimination in intensity-based brain tissue segmentations. Magn Reson Med 59:1190–1196, 2008.
- 21 April 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 59 (5) , 1190-1196
Open AccessHigh‐contrast 3D neonatal brain imaging with combined T1‐ and T2‐weighted MP‐RAGE
Optimization of magnetization-prepared rapid gradient-echo (MP-RAGE) sequence variations for maximum white matter (WM) versus gray matter (GM) contrast in neonates at 3T was investigated. Numerical simulations were applied to optimize and compare three contrast preparation modules and to assess the effect of phase encoding (PE) order on contrast between WM and thin cortical GM layers. Simulations predict that a new sequence, which combines both T1- and T2-weighting into the contrast preparation and utilizes an interleaved elliptical-spiral PE order, should provide the strongest contrast between neonatal WM and cortical GM. This sequence was compared to a conventional MP-RAGE acquisition (i.e., T1-weighted preparation, centric PE order) for in vivo imaging of seven preterm newborn infants. Regional measurements of the contrast-to-noise ratio (CNR) between WM and GM demonstrated an increase of 50–70% (depending on GM region) using the new sequence, in good agreement with theoretical predictions. This improved contrast resulted in superior WM versus GM discrimination in intensity-based brain tissue segmentations. Magn Reson Med 59:1190–1196, 2008.