Nasr Y. Khalil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nasr Y. Khalil has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Ibrahim Ali Darwish
Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia
8 shared publications - Muzaffar Iqbal
Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
3 shared publications - Essam Ezzeldin
Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, Riyadh P.O. Box 2457, Saudi Arabia
2 shared publications - Abdul-Aziz Al-Shaikh
Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia
1 shared publication - Abdullah M. Al-Hossaini
Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia
1 shared publication - Abdulrahman A. Al Majed
Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 17 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (20) , 10460
Development and Validation of a Novel Microwell-Based Fluorimetric Method Assisted with Fluorescence Plate Reader for High-Throughput Determination of Duvelisib: Application to the Analysis of Capsules and Plasma Samples
Duvelisib (DUV) is a novel drug with a small molecular weight and characterized by dual phosphoinositide-3-kinase (PI3K)- and PI3K-inhibitory activity. The Food and Drug Administration (FDA) recently approved DUV for the management of small lymphocytic lymphoma (SLL) and relapsed or refractory chronic lymphocytic leukemia (CLL) in adult patients. In the current study, a microwell-based fluorimetric (MW-FLR) method was established for the quantitation of DUV in copiktra® capsules as well as plasma samples. The proposed MW-FLR method was carried out in a 96-microwell plate and involved measuring the native fluorescence of DUV by using a fluorescence plate reader at 405 nm after excitation at 340 nm. The preparation of plasma samples involved simple one-step protein precipitation prior to the analysis. The optimum conditions for the proposed method were established. Under these conditions, the fluorescence signals showed an excellent linear relationship with DUV concentrations in the sample solutions (r = 0.9995) in a concentration range of 25–800 ng/mL. The detection and quantification limits were 20.5 and 62.1 ng/mL, respectively. The method's accuracy and precision were acceptable as the recovery values were not less than 98.5% with low relative standard deviations (less than 6%). The presented MW-FLR method was adopted with truly good accuracy and precision to analyze copiktra capsules and DUV-spiked plasma samples. The method's results were found to be superior to those of reference methods. The MW-FLR method combined the advantages of the inherent high sensitivity of the fluorimetric measurement and the high analytical throughput of microwell-based methods. In addition, the method is characterized by the simplicity of the procedures and the green chemistry approach as it uses water as a solvent and low volumes of sample solutions. These advantages gave the method great value for the determination of DUV in quality control and/or clinical laboratories.
- 17 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (20) , 10460
Open AccessDevelopment and Validation of a Novel Microwell-Based Fluorimetric Method Assisted with Fluorescence Plate Reader for High-Throughput Determination of Duvelisib: Application to the Analysis of Capsules and Plasma Samples
Duvelisib (DUV) is a novel drug with a small molecular weight and characterized by dual phosphoinositide-3-kinase (PI3K)- and PI3K-inhibitory activity. The Food and Drug Administration (FDA) recently approved DUV for the management of small lymphocytic lymphoma (SLL) and relapsed or refractory chronic lymphocytic leukemia (CLL) in adult patients. In the current study, a microwell-based fluorimetric (MW-FLR) method was established for the quantitation of DUV in copiktra® capsules as well as plasma samples. The proposed MW-FLR method was carried out in a 96-microwell plate and involved measuring the native fluorescence of DUV by using a fluorescence plate reader at 405 nm after excitation at 340 nm. The preparation of plasma samples involved simple one-step protein precipitation prior to the analysis. The optimum conditions for the proposed method were established. Under these conditions, the fluorescence signals showed an excellent linear relationship with DUV concentrations in the sample solutions (r = 0.9995) in a concentration range of 25–800 ng/mL. The detection and quantification limits were 20.5 and 62.1 ng/mL, respectively. The method's accuracy and precision were acceptable as the recovery values were not less than 98.5% with low relative standard deviations (less than 6%). The presented MW-FLR method was adopted with truly good accuracy and precision to analyze copiktra capsules and DUV-spiked plasma samples. The method's results were found to be superior to those of reference methods. The MW-FLR method combined the advantages of the inherent high sensitivity of the fluorimetric measurement and the high analytical throughput of microwell-based methods. In addition, the method is characterized by the simplicity of the procedures and the green chemistry approach as it uses water as a solvent and low volumes of sample solutions. These advantages gave the method great value for the determination of DUV in quality control and/or clinical laboratories.
- Open Access
- 26 April 2021
- Published by MDPI AG in Pharmaceuticals
- Vol. 14 (5) , 411
Improving the Solubilization and Bioavailability of Arbidol Hydrochloride by the Preparation of Binary and Ternary β-Cyclodextrin Complexes with Poloxamer 188
In the current study, the effect of poloxamer 188 on the complexation efficiency and dissolution of arbidol hydrochloride (ADL), a broad-spectrum antiviral agent, with β-cyclodextrin (β-CD) was investigated. Phase solubility studies confirmed a stoichiometry of a 1:1 ratio for both ADL:β-CD and ADL/β-CD with a 1% poloxamer 188 system with an AL type of phase solubility curve. The stability constants (K1:1) calculated from the AL type diagram were 550 M-1 and 2134 M-1 for AD:β-CD and ADL/β-CD with 1% poloxamer 188, respectively. The binary ADL/β-CD and ternary ADL/β-CD with 1% poloxamer 188 complexes were prepared by kneading and a solvent evaporation method and were characterized by aqueous solubility, FTIR, PXRD, DSC and SEM in vitro studies. The solubility (13.1 fold) and release of ADL were markedly improved in kneaded ternary ADL/β-CD with 1% poloxamer 188 (KDB). The binding affinity of ADL and β-CD was confirmed by 1H NMR and 2D ROSEY studies. The ternary complex (KDB) was further subjected for in vivo pharmacokinetic studies in rats and a significant improvement in the bioavailability (2.17 fold) was observed in comparison with pure ADL. Therefore, it can be concluded that the solubilization and bioavailability of ADL can be remarkably increased by ADL/β-CD complexation in the presence of a third component, poloxamer 188.
- 26 April 2021
- Published by MDPI AG in Pharmaceuticals
- Vol. 14 (5) , 411
Open AccessImproving the Solubilization and Bioavailability of Arbidol Hydrochloride by the Preparation of Binary and Ternary β-Cyclodextrin Complexes with Poloxamer 188
In the current study, the effect of poloxamer 188 on the complexation efficiency and dissolution of arbidol hydrochloride (ADL), a broad-spectrum antiviral agent, with β-cyclodextrin (β-CD) was investigated. Phase solubility studies confirmed a stoichiometry of a 1:1 ratio for both ADL:β-CD and ADL/β-CD with a 1% poloxamer 188 system with an AL type of phase solubility curve. The stability constants (K1:1) calculated from the AL type diagram were 550 M-1 and 2134 M-1 for AD:β-CD and ADL/β-CD with 1% poloxamer 188, respectively. The binary ADL/β-CD and ternary ADL/β-CD with 1% poloxamer 188 complexes were prepared by kneading and a solvent evaporation method and were characterized by aqueous solubility, FTIR, PXRD, DSC and SEM in vitro studies. The solubility (13.1 fold) and release of ADL were markedly improved in kneaded ternary ADL/β-CD with 1% poloxamer 188 (KDB). The binding affinity of ADL and β-CD was confirmed by 1H NMR and 2D ROSEY studies. The ternary complex (KDB) was further subjected for in vivo pharmacokinetic studies in rats and a significant improvement in the bioavailability (2.17 fold) was observed in comparison with pure ADL. Therefore, it can be concluded that the solubilization and bioavailability of ADL can be remarkably increased by ADL/β-CD complexation in the presence of a third component, poloxamer 188.
- Open Access
- 17 February 2014
- Published by Springer Nature in BMC Chemistry
- Vol. 8 (1) , 13
Simple, sensitive and rapid determination of linifanib (ABT-869), a novel tyrosine kinase inhibitor in rat plasma by UHPLC-MS/MS
Linifanib (ABT-869) is an orally active receptor tyrosine kinase inhibitor, which simultaneously inhibits vascular endothelial and platelet derived growth factor receptor. The aim of the present study was to develop an UHPLC-MS/MS method for the quantification of linifanib in rat plasma to support the pharmacokinetic and toxicokinetic studies.
- 17 February 2014
- Published by Springer Nature in BMC Chemistry
- Vol. 8 (1) , 13
Open AccessSimple, sensitive and rapid determination of linifanib (ABT-869), a novel tyrosine kinase inhibitor in rat plasma by UHPLC-MS/MS
Linifanib (ABT-869) is an orally active receptor tyrosine kinase inhibitor, which simultaneously inhibits vascular endothelial and platelet derived growth factor receptor. The aim of the present study was to develop an UHPLC-MS/MS method for the quantification of linifanib in rat plasma to support the pharmacokinetic and toxicokinetic studies.
- Open Access
- 14 March 2013
- Published by Springer Nature in BMC Chemistry
- Vol. 7 (1) , 52
Trace determination of lenalidomide in plasma by non-extractive HPLC procedures with fluorescence detection after pre-column derivatization with fluorescamine
Lenalidomide (LND) is a new potent drug used for treatment of multiple myeloma. For its pharmacokinetic studies and therapeutic monitoring, a proper analytical method was required.
- 14 March 2013
- Published by Springer Nature in BMC Chemistry
- Vol. 7 (1) , 52
Open AccessTrace determination of lenalidomide in plasma by non-extractive HPLC procedures with fluorescence detection after pre-column derivatization with fluorescamine
Lenalidomide (LND) is a new potent drug used for treatment of multiple myeloma. For its pharmacokinetic studies and therapeutic monitoring, a proper analytical method was required.
- Open Access
- 14 January 2013
- Published by Springer Nature in BMC Chemistry
- Vol. 7 (1) , 7
Development and validation of ultra-performance liquid chromatographic method with tandem mass spectrometry for determination of lenalidomide in rabbit and human plasma
Background: Lenalidomide (LND) is a potent novel thalidomide analog which demonstrated remarkable clinical activity in treatment of multiple myeloma disease via a multiple-pathways mechanism. Validated sensitive method with high throughput is required for the determination of lenalidomide for pharmacokinetics and toxicokinetic studies. Ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) is a preeminent analytical tool for rapid biomedical analysis.Results: A simple, highly sensitive UPLC-MS/MS method was developed and validated for the determination of LND in rabbit and human plasma. After a simple protein precipitation using methanol, LND and carbamazepine (IS) were separated on Acquity UPLC BEH™ C18column (50 × 2.1 mm, i.d. 1.7 μm, Waters, USA) using a mobile phase consisted of acetonitrile:water:formic acid (65:35:0.1%, v/v/v) pumped at a flow rate of 0.2 mL/min. LND and IS were eluted at 0.71 and 1.92 min, respectively. The mass spectrometric determination was carried out using an electrospray interface operated in the positive mode with multiple reaction monitoring (MRM) mode. The precursor to product ion transitions ofm/z260.1 > 149.0 andm/z237.0 > 179.0 were used to quantify LND and IS, respectively. The method was linear in the concentration range of 0.23–1000 ng/mL with a limit of quantitation of 0.23 ng/mL. All the validation parameters were in the ranges acceptable by the guidelines of analytical method validation.Conclusion: The proposed UPLC-MS/MS method is simple, rapid and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans.
- 14 January 2013
- Published by Springer Nature in BMC Chemistry
- Vol. 7 (1) , 7
Open AccessDevelopment and validation of ultra-performance liquid chromatographic method with tandem mass spectrometry for determination of lenalidomide in rabbit and human plasma
Background: Lenalidomide (LND) is a potent novel thalidomide analog which demonstrated remarkable clinical activity in treatment of multiple myeloma disease via a multiple-pathways mechanism. Validated sensitive method with high throughput is required for the determination of lenalidomide for pharmacokinetics and toxicokinetic studies. Ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) is a preeminent analytical tool for rapid biomedical analysis.Results: A simple, highly sensitive UPLC-MS/MS method was developed and validated for the determination of LND in rabbit and human plasma. After a simple protein precipitation using methanol, LND and carbamazepine (IS) were separated on Acquity UPLC BEH™ C18column (50 × 2.1 mm, i.d. 1.7 μm, Waters, USA) using a mobile phase consisted of acetonitrile:water:formic acid (65:35:0.1%, v/v/v) pumped at a flow rate of 0.2 mL/min. LND and IS were eluted at 0.71 and 1.92 min, respectively. The mass spectrometric determination was carried out using an electrospray interface operated in the positive mode with multiple reaction monitoring (MRM) mode. The precursor to product ion transitions ofm/z260.1 > 149.0 andm/z237.0 > 179.0 were used to quantify LND and IS, respectively. The method was linear in the concentration range of 0.23–1000 ng/mL with a limit of quantitation of 0.23 ng/mL. All the validation parameters were in the ranges acceptable by the guidelines of analytical method validation.Conclusion: The proposed UPLC-MS/MS method is simple, rapid and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans.
- Open Access
- 12 November 2012
- Published by Springer Nature in BMC Chemistry
- Vol. 6 (1) , 134
Use of response surface methodology for development of new microwell-based spectrophotometric method for determination of atrovastatin calcium in tablets
Background: Response surface methodology by Box–Behnken design employing the multivariate approach enables substantial improvement in the method development using fewer experiments, without wastage of large volumes of organic solvents, which leads to high analysis cost. This methodology has not been employed for development of a method for analysis of atorvastatin calcium (ATR-Ca). Results: The present research study describes the use of in optimization and validation of a new microwell-based UV-Visible spectrophotometric method of for determination of ATR-Ca in its tablets. By the use of quadratic regression analysis, equations were developed to describe the behavior of the response as simultaneous functions of the selected independent variables. Accordingly, the optimum conditions were determined which included concentration of 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ), time of reaction and temperature. The absorbance of the colored-CT complex was measured at 460 nm by microwell-plate absorbance reader. The method was validated, in accordance with ICH guidelines for accuracy, precision, selectivity and linearity (r² = 0.9993) over the concentration range of 20–200 μg/ml. The assay was successfully applied to the analysis of ATR-Ca in its pharmaceutical dosage forms with good accuracy and precision. Conclusion: The assay described herein has great practical value in the routine analysis of ATR-Ca in quality control laboratories, as it has high throughput property, consumes minimum volume of organic solvent thus it offers the reduction in the exposures of the analysts to the toxic effects of organic solvents, environmentally friendly "Green" approach) and reduction in the analysis cost by 50-fold.
- 12 November 2012
- Published by Springer Nature in BMC Chemistry
- Vol. 6 (1) , 134
Open AccessUse of response surface methodology for development of new microwell-based spectrophotometric method for determination of atrovastatin calcium in tablets
Background: Response surface methodology by Box–Behnken design employing the multivariate approach enables substantial improvement in the method development using fewer experiments, without wastage of large volumes of organic solvents, which leads to high analysis cost. This methodology has not been employed for development of a method for analysis of atorvastatin calcium (ATR-Ca). Results: The present research study describes the use of in optimization and validation of a new microwell-based UV-Visible spectrophotometric method of for determination of ATR-Ca in its tablets. By the use of quadratic regression analysis, equations were developed to describe the behavior of the response as simultaneous functions of the selected independent variables. Accordingly, the optimum conditions were determined which included concentration of 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ), time of reaction and temperature. The absorbance of the colored-CT complex was measured at 460 nm by microwell-plate absorbance reader. The method was validated, in accordance with ICH guidelines for accuracy, precision, selectivity and linearity (r² = 0.9993) over the concentration range of 20–200 μg/ml. The assay was successfully applied to the analysis of ATR-Ca in its pharmaceutical dosage forms with good accuracy and precision. Conclusion: The assay described herein has great practical value in the routine analysis of ATR-Ca in quality control laboratories, as it has high throughput property, consumes minimum volume of organic solvent thus it offers the reduction in the exposures of the analysts to the toxic effects of organic solvents, environmentally friendly "Green" approach) and reduction in the analysis cost by 50-fold.
- Open Access
- 16 October 2012
- Published by Springer Nature in BMC Chemistry
- Vol. 6 (1) , 118
A highly sensitive fluorimetric method for determination of lenalidomide in its bulk form and capsules via derivatization with fluorescamine
Lenalidomide (LND) is a potent novel thalidomide analog which demonstrated remarkable clinical activity in treatment of multiple myeloma disease via a multiple-pathways mechanism. The strong evidences-based clinical success of LND in patients has led to its recent approval by US-FDA under the trade name of Revlimid® capsules by Celgene Corporation. Fluorimetry is a convenient technique for pharmaceutical quality control, however there was a fluorimetric method for determination of LND in its bulk and capsules. A novel highly sensitive and simple fluorimetric method has been developed and validated for the determination of lenalidmide (LND) in its bulk and dosage forms (capsules). The method was based on nucleophilic substitution reaction of LND with fluorescamine (FLC) in aqueous medium to form a highly fluorescent derivative that was measured at 494 nm after excitation at 381 nm. The factors affecting the reaction were carefully studied and optimized. The kinetics of the reaction was investigated, and the reaction mechanism was postulated. Under the optimized conditions, linear relationship with good correlation coefficient (0.9999) was found between the fluorescence intensity and LND concentration in the range of 25-300 ng/mL. The limits of detection and quantitation for the method were 2.9 and 8.7 ng/mL, respectively. The precision of the method was satisfactory; the values of relative standard deviations did not exceed 1.4%. The proposed method was successfully applied to the determination of LND in its bulk form and pharmaceutical capsules with good accuracy; the recovery values were 97.8-101.4 ± 1.08-2.75%. The proposed method is selective and involved simple procedures. In conclusion, the method is practical and valuable for routine application in quality control laboratories for determination of LND.
- 16 October 2012
- Published by Springer Nature in BMC Chemistry
- Vol. 6 (1) , 118
Open AccessA highly sensitive fluorimetric method for determination of lenalidomide in its bulk form and capsules via derivatization with fluorescamine
Lenalidomide (LND) is a potent novel thalidomide analog which demonstrated remarkable clinical activity in treatment of multiple myeloma disease via a multiple-pathways mechanism. The strong evidences-based clinical success of LND in patients has led to its recent approval by US-FDA under the trade name of Revlimid® capsules by Celgene Corporation. Fluorimetry is a convenient technique for pharmaceutical quality control, however there was a fluorimetric method for determination of LND in its bulk and capsules. A novel highly sensitive and simple fluorimetric method has been developed and validated for the determination of lenalidmide (LND) in its bulk and dosage forms (capsules). The method was based on nucleophilic substitution reaction of LND with fluorescamine (FLC) in aqueous medium to form a highly fluorescent derivative that was measured at 494 nm after excitation at 381 nm. The factors affecting the reaction were carefully studied and optimized. The kinetics of the reaction was investigated, and the reaction mechanism was postulated. Under the optimized conditions, linear relationship with good correlation coefficient (0.9999) was found between the fluorescence intensity and LND concentration in the range of 25-300 ng/mL. The limits of detection and quantitation for the method were 2.9 and 8.7 ng/mL, respectively. The precision of the method was satisfactory; the values of relative standard deviations did not exceed 1.4%. The proposed method was successfully applied to the determination of LND in its bulk form and pharmaceutical capsules with good accuracy; the recovery values were 97.8-101.4 ± 1.08-2.75%. The proposed method is selective and involved simple procedures. In conclusion, the method is practical and valuable for routine application in quality control laboratories for determination of LND.
- Top Cited PapersOpen Access
- 3 January 2012
- Published by Springer Nature in BMC Chemistry
- Vol. 6 (1) , 1
Development of a novel 96-microwell assay with high throughput for determination of olmesartan medoxomil in its tablets
A novel 96-microwell-based spectrophotometric assay has been developed and validated for determination of olmesartan medoxomil (OLM) in tablets. The formation of a colored charge-transfer (CT) complex between OLM as a n-electron donor and 2, 5-dichloro-3, 6-dihydroxy-1, 4-benzoquinone (p-chloranilic acid, pCA) as a π-electron acceptor was investigated, for the first time, and employed as a basis in the development of the proposed assay. The proposed assay was carried out in 96-microwell plates. The absorbance of the colored-CT complex was measured at 490 nm by microwell-plate absorbance reader. The optimum conditions of the reaction and the analytical procedures of the assay were established. Under the optimum conditions, linear relationship with good correlation coefficient was found between the absorbance and the concentration of OLM in the range of 1-200 μg ml-1. The limits of detection and quantitation were 0.3 and 1 μg ml-1, respectively. No interference was observed from the additives that are present in the pharmaceutical formulation or from hydrochlorothiazide and amlodipine that are co-formulated with OLM in some formulations. The assay was successfully applied to the analysis of OLM in tablets with good accuracy and precision. The assay described herein has great practical value in the routine analysis of OLM in quality control laboratories, as it has high throughput property, consumes minimum volume of organic solvent thus it offers the reduction in the exposures of the analysts to the toxic effects of organic solvents, and reduction in the analysis cost by 50-fold. Although the proposed assay was validated for OLM, however, the same methodology could be used for any electron-donating analyte for which a CT reaction can be performed.
- 3 January 2012
- Published by Springer Nature in BMC Chemistry
- Vol. 6 (1) , 1
Top Cited PapersOpen AccessDevelopment of a novel 96-microwell assay with high throughput for determination of olmesartan medoxomil in its tablets
A novel 96-microwell-based spectrophotometric assay has been developed and validated for determination of olmesartan medoxomil (OLM) in tablets. The formation of a colored charge-transfer (CT) complex between OLM as a n-electron donor and 2, 5-dichloro-3, 6-dihydroxy-1, 4-benzoquinone (p-chloranilic acid, pCA) as a π-electron acceptor was investigated, for the first time, and employed as a basis in the development of the proposed assay. The proposed assay was carried out in 96-microwell plates. The absorbance of the colored-CT complex was measured at 490 nm by microwell-plate absorbance reader. The optimum conditions of the reaction and the analytical procedures of the assay were established. Under the optimum conditions, linear relationship with good correlation coefficient was found between the absorbance and the concentration of OLM in the range of 1-200 μg ml-1. The limits of detection and quantitation were 0.3 and 1 μg ml-1, respectively. No interference was observed from the additives that are present in the pharmaceutical formulation or from hydrochlorothiazide and amlodipine that are co-formulated with OLM in some formulations. The assay was successfully applied to the analysis of OLM in tablets with good accuracy and precision. The assay described herein has great practical value in the routine analysis of OLM in quality control laboratories, as it has high throughput property, consumes minimum volume of organic solvent thus it offers the reduction in the exposures of the analysts to the toxic effects of organic solvents, and reduction in the analysis cost by 50-fold. Although the proposed assay was validated for OLM, however, the same methodology could be used for any electron-donating analyte for which a CT reaction can be performed.
- Open Access
- 7 October 2011
- Published by Springer Nature in BMC Chemistry
- Vol. 5 (1) , 57
Novel microwell-based spectrophotometric assay for determination of atorvastatin calcium in its pharmaceutical formulations
The formation of a colored charge-transfer (CT) complex between atorvastatin calcium (ATR-Ca) as a n-electron donor and 2, 3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) as a π-electron acceptor was investigated, for the first time. The spectral characteristics of the CT complex have been described, and the reaction mechanism has been proved by computational molecular modeling. The reaction was employed in the development of a novel microwell-based spectrophotometric assay for determination of ATR-Ca in its pharmaceutical formulations. The proposed assay was carried out in 96-microwell plates. The absorbance of the colored-CT complex was measured at 460 nm by microwell-plate absorbance reader. The optimum conditions of the reaction and the analytical procedures of the assay were established. Under the optimum conditions, linear relationship with good correlation coefficient (0.9995) was found between the absorbance and the concentration of ATR-Ca in the range of 10-150 μg/well. The limits of detection and quantitation were 5.3 and 15.8 μg/well, respectively. No interference was observed from the additives that are present in the pharmaceutical formulation or from the drugs that are co-formulated with ATR-Ca in its combined formulations. The assay was successfully applied to the analysis of ATR-Ca in its pharmaceutical dosage forms with good accuracy and precision. The assay described herein has great practical value in the routine analysis of ATR-Ca in quality control laboratories, as it has high throughput property, consumes minimum volume of organic solvent thus it offers the reduction in the exposures of the analysts to the toxic effects of organic solvents, and reduction in the analysis cost by 50-fold. Although the proposed assay was validated for ATR-Ca, however, the same methodology could be used for any electron-donating analyte for which a CT reaction can be performed.
- 7 October 2011
- Published by Springer Nature in BMC Chemistry
- Vol. 5 (1) , 57
Open AccessNovel microwell-based spectrophotometric assay for determination of atorvastatin calcium in its pharmaceutical formulations
The formation of a colored charge-transfer (CT) complex between atorvastatin calcium (ATR-Ca) as a n-electron donor and 2, 3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) as a π-electron acceptor was investigated, for the first time. The spectral characteristics of the CT complex have been described, and the reaction mechanism has been proved by computational molecular modeling. The reaction was employed in the development of a novel microwell-based spectrophotometric assay for determination of ATR-Ca in its pharmaceutical formulations. The proposed assay was carried out in 96-microwell plates. The absorbance of the colored-CT complex was measured at 460 nm by microwell-plate absorbance reader. The optimum conditions of the reaction and the analytical procedures of the assay were established. Under the optimum conditions, linear relationship with good correlation coefficient (0.9995) was found between the absorbance and the concentration of ATR-Ca in the range of 10-150 μg/well. The limits of detection and quantitation were 5.3 and 15.8 μg/well, respectively. No interference was observed from the additives that are present in the pharmaceutical formulation or from the drugs that are co-formulated with ATR-Ca in its combined formulations. The assay was successfully applied to the analysis of ATR-Ca in its pharmaceutical dosage forms with good accuracy and precision. The assay described herein has great practical value in the routine analysis of ATR-Ca in quality control laboratories, as it has high throughput property, consumes minimum volume of organic solvent thus it offers the reduction in the exposures of the analysts to the toxic effects of organic solvents, and reduction in the analysis cost by 50-fold. Although the proposed assay was validated for ATR-Ca, however, the same methodology could be used for any electron-donating analyte for which a CT reaction can be performed.