    Analytical considerations for the biochemical assessment of vitamin D status

    by Lewis Couchman, Cajetan F Moniz

    The most widely used and clinically accepted biochemical marker for assessing vitamin D status is the total serum 25-hydroxyvitamin D [25(OH)D] concentration. Despite the analysis of 25(OH)D dating back to the early 1970s, modern analytical techniques still exhibit significant interassay variability due to varying concentrations of other related vitamin D metabolites and sample-to-sample matrix differences. It is important for clinicians requesting 25(OH)D analyses to understand these issues and limitations, and where necessary to confront laboratories for details of analytical methods used. The availability of reference measurement procedures for 25(OH)D based on liquid chromatography and tandem mass spectrometry, whilst not intended for routine clinical sample analysis, should be utilized to improve assay harmonization and reduce interlaboratory variability. Laboratories should also be forthcoming with details of subscriptions to external quality assessment schemes and assay traceability. As well as discussing the reasons for ongoing assay variability for 25(OH)D, this short review will also briefly discuss other assays related to the assessment of vitamin D status, including parathyroid hormone, 24,25-dihydroxyvitamin D, 1,25-dihydroxyvitamin D and vitamin D binding proteins.


  • Open Access

    Sex differences in plasma clozapine and norclozapine concentrations in clinical practice and in relation to body mass index and plasma glucose concentrations: a retrospective survey

    by Simon G. Anderson, Mark Livingston, Lewis Couchman, Daniel J. Smith, Moira Connolly, Joan Miller, Robert J. Flanagan, A. H. Heald

    Clozapine is widely prescribed and, although effective, can cause weight gain and dysglycemia. The dysmetabolic effects of clozapine are thought to be more prevalent in women with this gender on average attaining 17 % higher plasma clozapine concentrations than men. We investigated the relationship between dose, body mass index (BMI), plasma glucose concentration, and plasma clozapine and N-desmethylclozapine (norclozapine) concentrations in 100 individuals with a severe enduring mental illness. Mean (10th/90th percentile) plasma clozapine concentrations were higher for women [0.49 (0.27–0.79) mg/L] compared with men [0.44 (0.26–0.70) mg/L] (F = 2.2; p = 0.035). There was no significant gender difference in the prescribed clozapine dose. BMI was significantly higher in women [mean (95 % CI) = 34.5 (26.0–45.3)] for females compared with 32.5 (25.2–41.0) for males. Overall, BMI increased by 0.7 kg/m2 over a mean follow-up period of 210 days. A lower proportion, 41 % of women had a fasting blood glucose ≤6.0 mmol/L (<6.0 mmol/L is defined by the International Diabetes Federation as normal glucose handling), compared with 88 % of men (χ 2 = 18.6, p < 0.0001). We have shown that mean BMI and blood glucose concentrations are higher in women prescribed clozapine than in men. Women also tended to attain higher plasma clozapine concentrations than men. The higher BMI and blood glucose in women may relate to higher tissue exposure to clozapine, as a consequence of sex differences in drug metabolism.


  • The use of turbulent flow chromatography for rapid, on‐line analysis of tryptic digests

    by L. Couchman, D. J. L. Jones, C. F. Moniz

    Rationale: Following digestion of proteins with trypsin, digests are typically subjected to further 'clean‐up' prior to liquid chromatography/mass spectometry (LC/MS) analysis, in order to reduce the complexity of the digested matrix, as well as helping to remove residual denaturants and reduction/alkylation reagents prior to injection onto the analytical HPLC column. Often, this is carried out using off‐line techniques, and is not ideally suited to high‐throughput workloads, for example in clinical laboratories. Methods: Bovine serum albumin (BSA) was used as a model protein. Following denaturation with urea, reduction/alkylation, and digestion with trypsin, the analytical recovery of a selection of proteotypic BSA peptides was assessed using a two‐dimensional, turbulent flow chromatography method. Peptides were identified using a Q Exactive™ mass spectometer operating in full‐scan mode. Results: Total analysis time (including the on‐line sample clean‐up) was 15 min per injection. Aside from the most hydrophilic peptide selected, ATEEQLK, recovery using the turbulent flow chromatography systems was greater than 30% for all remaining peptides (N = 17), and exceeded 50% for 12 of the 18 peptides studied. There was a broad correlation between the hydrophobicity factor and the observed recovery. Conclusions: This study suggests that turbulent flow chromatography offers a rapid, on‐line alternative to solid‐phase extraction for the analysis of peptide digests by LC/MS. A wide range of column chemistries are available, and the technique can be further optimised for analyses which are targetted to specific peptides. As with turbulent flow chromatography for small‐molecule workflows, this approach may be ideally suited to high‐throughput applications, such as those which are emerging from within clinical laboratories. Copyright © 2015 John Wiley & Sons, Ltd.

  • Open Access

    LC-MS candidate reference methods for the harmonisation of parathyroid hormone (PTH) measurement: a review of recent developments and future considerations

    by Lewis Couchman, David R. Taylor, Bryan Krastins, Mary F. Lopez, Cajetan F. Moniz

    The analysis of intact parathyroid hormone (PTH) (PTH1-84) is useful in the diagnosis of hyper- and hypocalcaemia, hyperparathyroidism, and in the prevention of bone mineral disorders in renal patients. The analysis is complicated by the presence of PTH fragments, which may accumulate in renal failure and cross-react in immunoassays, including the most recent third-generation immunoassays. Large variability exists between different commercially available assays. This article reviews the current literature on PTH testing, with emphasis on the use of mass spectrometry-based methods, and considers the important sources of variation which still need to be addressed prior to the development of much needed candidate reference methods for PTH analysis. Recently, mass spectrometric methods have been developed for the quantitation of PTH1-84 using surrogate tryptic peptides, but even these methods are subject to significant interferences due to the presence of newly observed modified PTH species, such as oxidised and phosphorylated PTH variants, which can accumulate in patient samples. Further work, including: 1) the use of high-resolution mass spectrometry; and 2) the analysis of PTH without prior protease digestion, is required before these approaches can be considered as reference methods against which other methods should be harmonised.


  • A novel approach to quantitative LC-MS/MS: therapeutic drug monitoring of clozapine and norclozapine using isotopic internal calibration

    by Lewis Couchman, Sarah L. Belsey, Simon A. Handley, Robert J. Flanagan

    Therapeutic drug monitoring (TDM) requires timely results in order to be clinically helpful. Such assays, when carried out using mass spectrometry-based methods, typically involve a batched sample approach with multipoint calibration. Isotopic internal calibration offers the possibility of open-access mass spectrometric analysis with consequent shortening of turnaround times. We measured plasma clozapine and N-desmethylclozapine (norclozapine) concentrations in (1) external quality assessment (EQA) samples (N = 22) and (2) patient samples (N = 100) using liquid chromatography-tandem mass spectrometry with isotopic internal calibration (ICAL-LC-MS/MS). Analyte concentrations were calculated from graphs of the response of three internal calibrators (clozapine-D4, norclozapine-D8, and clozapine-D8) against concentration. Precision (% RSD) and accuracy (% nominal concentrations) for the ICAL-LC-MS/MS method were R 2 = 0.98 and 0.97, respectively, inclusive of clozapine and norclozapine results). In the patient samples, comparison against traditionally calibrated HPLC-UV and LC-MS/MS methods showed excellent agreement (R 2 = 0.97 or better) with small albeit significant mean differences (Figure


  • Mass spectrometric immunoassay for intact parathyroid hormone: correlation with immunoassay and application to clinical samples

    by L Couchman, D Taylor, B Krystans, M Lopez, A Prakash, D Sarracino, A Garces, M Vogelsang, S Peterman, G Vadali, et al.

    Introduction: Parathyroid hormone (PTH) measurement is of use in i) differential diagnosis of hypercalcaemia and ii) patients with renal impairment at risk of bone disease. PTH immunoassays are complicated by cross-reactivity with truncated (inactive) variant forms, which accumulate in patients with renal impairment. PTH assay variability is a critical governance issue in renal medicine, suggesting an MS-based reference method is required. Aim: To develop a mass spectrometric immunoassay (MSIA) for intact PTH quantification, and to compare results with a PTH immunoassay. Methods: Plasma PTH was immunocaptured onto MSIA pipette tips pre-bound with anti-PTH antibody, using an automated liquid handler (Versette). Captured analytes were eluted from the tips, digested and specific tryptic peptides analysed by LC–MS/MS, using labelled peptides and recombinant PTH standards for assay calibration. Samples (n=357) analysed by immunoassay (Advia Centaur) then re-analysed by MSIA for comparison. Results: The MSIA assay demonstrated excellent linearity (R2=0.90–0.99), sensitivity (LOQ, 16 pg/ml), specificity and precision (CV R2=0.67) between the immunoassay and the surrogate N-terminal tryptic peptide (aa 1–13) for intact PTH, ii) better correlation (R2=0.86) of ‘mean PTH’ by MSIA (i.e. the mean concentration of all tryptic peptides, including variant forms), iii) identification of novel variant forms in samples from patients with renal disease, and iv) the commonly-cited variant form PTH 7–84 was not detected. Conclusions: This approach allows rapid, automated immunoenrichment achieving high sensitivity and selectivity. MSIA allows the simultaneous monitoring of intact and variant PTH forms. Correlation of the PTH MSIA assay using only the N-terminal tryptic peptide (aa 1–13) with immunoassay demonstrated that the immunoassay overestimates the amount of active PTH. This difference was greater in patients with renal impairment, in whom PTH concentrations direct clinical decisions.

  • Open Access

    False-Positive Buprenorphine by CEDIA in Patients Prescribed Amisulpride or Sulpiride

    by M. A. Birch, L. Couchman, S. Pietromartire, T. Karna, C. Paton, R. McAllister, A. Marsh, R. J. Flanagan

    Buprenorphine is a potent partial opioid agonist that is analyzed in urine to (i) monitor adherence to maintenance or detoxification therapy and (ii) detect illicit use. Buprenorphine analysis is commonly conducted on urine by immunoassay, but is subject to cross-reactivity from other drugs/drug metabolites, including morphine, codeine and dihydrocodeine. This study reports false-positive buprenorphine analysis [Thermo Fisher Scientific cloned enzyme donor immunoassay (CEDIA)] in patients who denied unauthorized buprenorphine use prior to sampling, but who had been prescribed amisulpride. In two cases, confirmatory analysis by liquid chromatography–tandem mass spectrometry was negative (<0.5 µg/L) for buprenorphine and metabolites and positive for amisulpride. Although the cross-reactivity of amisulpride and sulpiride in the CEDIA buprenorphine assay is low (estimated at 0.003 and 0.002%, respectively), it remains a significant consideration given the likely high concentrations of these compounds in urine relative to the low cutoff of the buprenorphine assay. Neither amisulpride nor sulpiride was listed as potential sources of interference on the CEDIA data sheet when this work was performed. These findings highlight the importance of confirming immunoassay-positive buprenorphine results using a more selective analytical technique.


  • Conference Report: Advances in Clinical Analysis 2012

    by Lewis Couchman, Graham A Mills

    A report on the meeting organized by The Chromatographic Society and the Separation Science Group, Analytical Division of the Royal Society of Chemistry. Over 60 delegates and commercial exhibitors attended this event, held to celebrate the careers of Robert Flanagan and David Perrett, and acknowledge their extensive contributions in the field of clinical analysis.