RVRodolfo Ventura

Rodolfo Ventura

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rodolfo Ventura has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Stable and Unstable Ventricular Tachycardias in Patients with Previous Myocardial Infarction: A Clinically Oriented Strategy for Catheter Ablation

    by Rodolfo Ventura, Hanno U. Klemm, Thomas Rostock, Boris Lutomsky, Tim Risius, Daniel Steven, Christian Weiss, Thomas Meinertz, Stephan Willems

    Objective: Catheter ablation of ventricular tachycardia (VT) after myocardial infarction (MI) can be complex and time-consuming. We only targeted the previously documented VTs and those with similar or longer cycle lengths. Methods: 30 patients with VTs after MI were included in the study. Voltage mapping was performed using an electro-anatomic mapping system (CARTOT). Stable VTs were mapped during tachycardia and unstable VTs during sinus rhythm. Results: Clinical VTs were stable in 16 (53%) and unstable in 14 (47%) patients, and ablation was successful in 11 (69%) and 9 patients (64%), respectively (p = 0.42). During follow-up (14 ± 6 months), 4 patients (25%) treated for stable and 6 (43%) for unstable VTs had recurrences (p = 0.82); ablation was successful in none and 2 (33%) of them, respectively. Non-target VTs were inducible in 11 (55%) of 20 patients after successful ablation and non-inducible in 9 (45%). During follow-up, inducibility of non-target VTs did not predict recurrences (9 vs. 11%, p = 0.88). Conclusions: Catheter ablation of VTs after MI can be successfully performed. Acute success rates seem to be similar for stable and unstable VTs. VTs faster than those documented clinically exert a minor effect on VT recurrences during follow-up.


  • Decennial follow-up in patients with recurrent tachycardia originating from the right ventricular outflow tract: electrophysiologic characteristics and response to treatment

    by Rodolfo Ventura, Daniel Steven, Hanno U. Klemm, Boris Lutomsky, Kai Müllerleile, Thomas Rostock, Helge Servatius, Tim Risius, Thomas Meinertz, Karl-Heinz Kuck, et al.

    Aims In the setting of right ventricular outflow tract-tachycardia (RVOT-T), data about long-term follow-up (FU) with respect to the therapeutic strategies are missing. All patients (pts) referred to our institution during the last 20 years for the treatment of RVOT-T were studied in a retrospective analysis to assess mortality and efficacy of treatment.


  • Pattern of Isthmus Conduction Recovery Using Open Cooled and Solid Large‐Tip Catheters for Radiofrequency Ablation of Typical Atrial Flutter

    by Rodolfo Ventura, Hanno Klemm, Boris Lutomsky, Cagri Demir, Thomas Rostock, Christian Weiss, Thomas Meinertz, Stephan Willems

    Open cooled-tip and solid 8-mm-tip catheters have demonstrated safety and effectiveness for radiofrequency current (RFC) ablation of typical atrial flutter (AFL). However, data from prospective and randomized studies in this setting are lacking. One hundred thirty consecutive patients (104 men; 61 +/- 11 years) with AFL were randomized to undergo RFC catheter ablation either using a solid 8-mm-tip catheter (group A, 65 degrees C, 70 W, 60 s) or an open irrigated-tip catheter (group B, 65 degrees C, 50 W, 60 s, 17 mL/min flow). Endpoint was bidirectional conduction isthmus block. In cases of repeated (two times) transient isthmus block, the catheter was changed (crossed over) to the catheter used in the other randomization arm, but patients remained in the original group following intention-to-treat analysis. The selected endpoint could be achieved in all patients after 12 +/- 6 RFC pulses in group A and 10 +/- 7 RFC pulses in group B (P = 0.11). Procedure times were longer (159 +/- 38 min vs 138 +/- 37 min, P = 0.002) and x-ray exposures higher in group A (fluoroscopy time 25 +/- 17 min vs 21 +/- 10 min, P = 0.08; x-ray dosage 3,133 +/- 2,576 cGy.cm2 vs 2,326 +/- 1,405 cGy.cm2, P = 0.03). Transient isthmus block was observed in 23 group A patients and 12 group B patients (P = 0.03). Onset time of transient isthmus block ranged from 0.5 to 27 minutes. Repeated transient isthmus block occurred in 8 of the 23 patients in group A after 19 +/- 3 RFC applications. After crossover to the cooled-tip catheter, the endpoint was reached another 5 +/- 1 RFC pulses. In group B, all patients could be treated without change of ablation catheter. After a follow-up of 14 +/- 2 months, 2 patients (3%) in group A and 1 patient (1.5%) in group B presented with AFL recurrence. Open cooled-tip catheters are more effective than solid large-tip catheters for AFL ablation. The greater effectiveness is evident in cases showing repeated conduction recovery within the cavotricuspid isthmus. Primary use of open irrigated-tip catheters should be considered for AFL ablation.


  • Catheter Ablation of Common‐Type Atrial Flutter Guided by Three‐Dimensional Right Atrial Geometry Reconstruction and Catheter Tracking Using Cutaneous Patches:

    by Rodolfo Ventura, Thomas Rostock, Hanno U. Klemm, Boris Lutomsky, Cagri Demir, Christian Weiss, Thomas Meinertz, Stephan Willems

    EnSite NavX (NavX) is a novel mapping and navigation system that allows visualization of conventional catheters for diagnostic and ablative purposes and uses them to create a three-dimensional (3D) geometry of the heart. NavX is particularly suitable for ablation procedures utilizing an anatomic approach, as in the setting of common-type atrial flutter (AFL). The aim of this study was to compare NavX-guided and conventional ablation procedures for AFL. Forty consecutive patients (32 male, 59 +/- 12 years) with documented AFL were randomized to undergo fluoroscopy-guided (group I, 20 patients) or NavX-guided (group II, 20 patients) ablation, including 3D isthmus reconstruction. The same catheter setup was used in both groups. The endpoint of bidirectional isthmus block was obtained in all patients. Compared to conventional approaches, NavX-guided procedures significantly reduced fluoroscopy time (5.1 +/- 1.4 min vs 20 +/- 11 min, P < 0.01) and total x-ray exposure (5.1 +/- 3.1 Gycm2 vs 24.9 +/- 1.6 Gycm2, P < 0.01). Isthmus geometry reconstruction could be performed in all patients of group II. In 4 patients (20%) of group II, anatomic isthmus variations were detected by NavX. No significant differences in radiofrequency current applications and procedural times were found between the two groups. NavX technology allows geometry reconstruction of the cavotricuspid isthmus. NavX-guided ablation of AFL reduces total x-ray exposure compared to the fluoroscopy-guided approach but does not prolong procedure time.


  • Radiofrequency Catheter Ablation of a Macroreentrant Ventricular Tachycardia Late After Surgical Repair of Tetralogy of Fallot Using the Electroanatomic Mapping (CARTO)

    by Thomas Rostock, Stephan Willems, Rodolfo Ventura, Christian Weiss, Tim Risius, Thomas Meinertz

    This case report describes a patient with a sustained monomorphic VT after surgical repair of a tetralogy of Fallot (TOF). In combination with the three-dimensional electroanatomic mapping system, CARTO, and conventional mapping techniques the VT was identified as a macro-reentrant tachycardia circling around the border between pulmonary graft and right ventricular outflow tract (RVOT). A y-shaped ablation line crossing this zone was created. The VT terminated during RF application and was not inducible again. This case underlines the use of a combined conventional and three-dimensional electroanatomic mapping technique can be helpful for catheter ablation of ventricular arrhythmias in TOF patients.


  • Large Tip Electrodes for Successful Elimination of Atrial Flutter Resistant to Conventional Catheter Ablation

    by Rodolfo Ventura, Stephan Willems, Christian Weiss, Joerg Flecke, Tim Risius, Thomas Rostock, Matthias Hoffmann, Thomas Meinertz

    The most widely accepted criterion for successful radiofrequency catheter (RFC) ablation of typical atrial flutter is the development of bi-directional isthmus block. In a subset of patients,...


  • Atrial Premature Beats in Patients with Focal Atrial Fibrillation: Incidence at Baseline and Impact of Provocative Maneuvers

    by Rodolfo Ventura, Christian Weiss, Stephan Willems, Nina Sturm, Hanno Klemm, Thomas Meinertz

    VENTURA, R., et al.: Atrial Premature Beats in Patients with Focal Atrial Fibrillation: Incidence at Baseline and Impact of Provocative Maneuvers. This study evaluated the incidence of atrial premature beats (APBs) and the impact of various provocative maneuvers in patients with focally initiated AF. Fifty patients (39 men, 57 ± 0.4 years) with focally initiated, paroxysmal AF underwent Holter recording and a standardized protocol of provocative maneuvers: vagomechanical stimulation, adenosine 12 mg IV, esmolol 500 ng/kg IV, orciprenaline IV 5 mg/50 mL saline 0.9%, and atropine 0.01 mg/kg IV A surface ECG was recorded for 20 minutes at baseline and following each part of the protocol. High focal activity was defined as ≥ 1 APB/minute. During Holter ECG, 29 (58%) patients had an amount of < 200 APBs, 12 (24%) patients < 700 ≥ 200, and 9 (18%) patients ≥ 700 APBs. Less than 1 hour of high focal activity was observed in 34 (68%) of the 50 patients. Before starting provocative maneuvers 15 (30%) patients had high focal activity whereas 35 (70%) presented < 1 APB/minute. In 29 (58%) patients APBs increased by ≥ 1/min during provocative maneuvers: by vagomechanical stimulation in 11 patients, after adenosine in 15, esmolol in 12, orciprenaline in 15, and after atropine in 9 patients. In all patients with ≥ 1 APB/min at baseline, focal activity decreased or disappeared during some single provocative maneuvers. AF occurred in eight patients under provocative maneuvers. No predictive factors of a successful provocative maneuver were detected with regard to the baseline patients characteristics and Holter results. In conclusion, patients with focally initiated AF have a low incidence of spontaneous APBs. Various provocative maneuvers successfully increase APBs in more than half of the patients; orciprenaline had the highest efficacy. Some provocative maneuvers may suppress APBs in the setting of high focal activity at baseline.


  • A Randomized and Controlled Pilot Trial of β‐blockers for the Treatment of Recurrent Syncope in Patients with a Positive or Negative Response to Head‐Up Tilt Test

    by Rodolfo Ventura, Renke Maas, Daniel Zeidler, Volker Schoder, Cristhoph A. Nienaber, Andreas Schuchert, Thomas Meinertz

    VENTURA, R., et al.: A Randomized and Controlled Pilot Trial of b‐Blockers for the Treatment of Recurrent Syncope in Patients with a Positive or Negative Response to Head‐Up Tilt Test. The aim of this study was to assess the efficacy of lipophilic β‐blockers in preventing recurrent neurocardiogenic syncope and the value of head‐up tilt test (HUT) in predicting response to therapy. The efficacy of β‐blockers in recurrent syncope is controversial. The value of HUT in predicting efficacy of therapy has not been investigated. Fifty‐six patients (44 ± 18 years, 36 women) with recurrent syncope (> 1 event in the last 6 months) of suspected neurocardiogenic origin were included in the study. Independent of the response to HUT, patients were randomized to receive metoprolol or propanolol at the maximal tolerated dose (28 patients, group A, 86 ± 23 vs 98 ± 29 mg/d) or no pharmacological therapy (28 patients, group B). The primary endpoint was the first recurrence of syncope. During the 1‐year of follow‐up, 20 patients of group A and 8 of group B had no recurrence. In group A, of 20 patients without recurrences 12 had a positive and 8 a negative HUT result while of 8 patients with recurrences 5 had a positive and 3 a negative response to HUT. In the group B, of 20 patients with recurrences 10 had a positive and 10 a negative HUT result while of 8 patients without recurrences 4 had a positive and 4 a negative response to HUT. In a multivariate Cox‐regression analysis, medical therapy was the only independent factor for predicting recurrence of syncope (P = 0.004); HUT had no influence in this regard (P = 0.773). In conclusion, lipophilic β‐blockers appear efficacious in preventing recurrent syncope of suspected neurocardiogenic origin. The efficacy of therapy seems to be not predicted by HUT.


  • Open Access

    Psychiatric conditions in patients with recurrent unexplained syncope

    by R. Ventura, R. Maas, R. RÜPpel, U. Stuhr, A. Schuchert, T. Meinertz, C. A. Nienaber

    The relationship between syncope and psychiatric disorders is little investigated. This study evaluated the prevalence of psychiatric diseases and prognostic outcome in patients with recurrent unexplained syncope. After an inconclusive standard diagnostic work-up for syncope, including head-up tilt testing, a psychiatric evaluation was offered to 50 consecutive patients with recurrent syncope. The evaluation was accepted by 26 patients (77% females, 36±16 years) and refused by 24 (63% females, 50±19 years). A psychiatric disorder was diagnosed in 21 (81%) patients: 12 had depression, four panic attacks, two general anxiety, and three a somatization disorder. Only five patients showed normal psychosocial function. Of the patients with psychiatric disorders four accepted psychiatric care, such as psychotherapy and/or pharmacotherapy; 17 patients refused treatment. During 6 months of follow-up no patient under psychiatric care had syncope, while all patients without psycho- or pharmacotherapy had recurrent syncopal events. In these patients the median of syncopal episodes was three in a 6 months interval before and after clinical assessment. Patients who refused both psychiatric evaluation and therapy continued to experience syncope as before. In patients with recurrent unexplained syncope psychiatric alteration is common. However, patients seldom accepted a psychiatric evaluation and treatment.


    • 1 April 2001
      • Vol. 2  (4) , 306-11

    Intravenous coronary angiography using synchrotron radiation: technical description and preliminary results.

    by R Ventura, T Dill, W R Dix, M Lohmann, H Job, W Kupper, R Fattori, C A Nienaber, C W Hamm, T Meinertz

    Standard coronary angiography requires an arterial access and catheters; intravenous coronary angiography may image coronary arteries noninvasively and without catheters. The aim of this study was the assessment of the diagnostic accuracy of intravenous coronary angiography validated by selective coronary angiography. Seventy outpatients (80% males, mean age 62 +/- 8 years) underwent both standard and intravenous coronary angiography after a previous coronary intervention. Intravenous coronary angiography was performed within 6 weeks before or after selective coronary angiography. Two different projections were used to obtain 6-8 sequences per patient. Images were taken after injection of the contrast agent into the brachial vein or into the superior vena cava. During image acquisition, patients were moved through the scanning beam on a special chair. Thereafter, images were evaluated and compared to selective coronary angiograms for the following criteria: no stenosis, subsignificant stenosis (< 70%), significant stenosis (> or = 70%), and occlusion. One hundred eighty-seven target vessels were analyzed. In 50 target vessels one or more stents had been implanted. Seventeen target vessels were not analyzable due to inadequate image quality. The sensitivity of intravenous coronary angiography for the detection of lesions was 80% and the specificity was 95%. The sensitivity for the detection of significant lesions in the left anterior descending coronary artery was 84% (specificity 93%), in the left circumflex coronary artery 67% (specificity 90%), in the right coronary artery 85% (specificity 97%), and in bypass grafts 85% (specificity 97%). No complications were observed. Intravenous coronary angiography is efficacious and safe and allows quantification of lesions of the coronary arteries and of bypass vessels. Further advances in image processing are needed to improve sensitivity especially in the left circumflex coronary artery.