Helmut Wiedemayer
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Helmut Wiedemayer has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Dietmar Stolke
5 shared publicationsIbrahim Erol Sandalcioglu
3 shared publicationsD. Stolke
2 shared publicationsHeike Schaefer
2 shared publicationsHeike Schäfer
2 shared publicationsI. E. Sandalcioglu
2 shared publications
Latest Publications
- 1 August 2004
- Published by Wolters Kluwer Health in Spine
- Vol. 29 (16) , E333-E342
Reconstruction of the Laminar Roof With Miniplates for a Posterior Approach in Intraspinal Surgery: Technical Considerations and Critical Evaluation of Follow-up Results
A retrospective clinical follow-up study of patients who underwent intraspinal surgery with reconstruction of the laminar roof using titanium miniplates. To evaluate the surgical technique of laminar roof reconstruction and to analyze follow-up results with regard to bony healing of the laminae and the development of spinal deformities. The reconstruction of the laminar roof was initially proposed to overcome adverse effects associated with extensive cervical laminectomy in children. Because technical evolutions such as the use of an air drill and miniplates have facilitated the procedure, it has gained more widespread use as a posterior approach for intraspinal surgery. Thus, with a sufficient number of patients treated and a longer period of follow up, it seems reasonable to critically evaluate the technique and its suitability as a standard approach for intraspinal surgery. The surgical procedures of 79 patient who underwent intraspinal surgery with osteotomy and reconstruction of a total of 323 spinal laminae using an air drill and miniplates were analyzed. In 59 patients, data of a complete clinical and radiologic follow-up examination were evaluated. Plain radiographs and computed tomography scans were analyzed for bony healing of the laminae and spinal alignment. Minor complications such as cerebrospinal fluid collections and disturbed wound healing occurred within normal ranges. The was no case of dural, nerve root, or spinal cord injury attributable to laminotomy or laminar reconstruction. Eight (14.3%) patients complained of moderate to severe local pain at the time of follow-up examination and 8 patients stated impaired mobility of their spine at the surgical site. Bony healing was confirmed radiologically in 86.1% of the laminae. In 12 patients, a preexisting spinal deformity worsened after surgery and five patients demonstrated a new spinal malalignment. No patient required additional surgery because of progressive spinal deformity. Intramedullary location of the lesion and cervical location of surgery were significantly associated with the development of spinal malalignment, whereas incomplete bony healing of the laminae was not. The reconstruction of the laminar roof using the technique described is safe, well suitable to serve as a standard posterior approach to intraspinal pathologies, and offers distinct advantages over laminectomy. However, some patients, particularly those with intramedullary cervical lesions, could develop spinal malalignment after surgery despite reconstruction of the laminar roof and sufficient bony healing of the laminae.
- 1 August 2004
- Published by Wolters Kluwer Health in Spine
- Vol. 29 (16) , E333-E342
Reconstruction of the Laminar Roof With Miniplates for a Posterior Approach in Intraspinal Surgery: Technical Considerations and Critical Evaluation of Follow-up Results
A retrospective clinical follow-up study of patients who underwent intraspinal surgery with reconstruction of the laminar roof using titanium miniplates. To evaluate the surgical technique of laminar roof reconstruction and to analyze follow-up results with regard to bony healing of the laminae and the development of spinal deformities. The reconstruction of the laminar roof was initially proposed to overcome adverse effects associated with extensive cervical laminectomy in children. Because technical evolutions such as the use of an air drill and miniplates have facilitated the procedure, it has gained more widespread use as a posterior approach for intraspinal surgery. Thus, with a sufficient number of patients treated and a longer period of follow up, it seems reasonable to critically evaluate the technique and its suitability as a standard approach for intraspinal surgery. The surgical procedures of 79 patient who underwent intraspinal surgery with osteotomy and reconstruction of a total of 323 spinal laminae using an air drill and miniplates were analyzed. In 59 patients, data of a complete clinical and radiologic follow-up examination were evaluated. Plain radiographs and computed tomography scans were analyzed for bony healing of the laminae and spinal alignment. Minor complications such as cerebrospinal fluid collections and disturbed wound healing occurred within normal ranges. The was no case of dural, nerve root, or spinal cord injury attributable to laminotomy or laminar reconstruction. Eight (14.3%) patients complained of moderate to severe local pain at the time of follow-up examination and 8 patients stated impaired mobility of their spine at the surgical site. Bony healing was confirmed radiologically in 86.1% of the laminae. In 12 patients, a preexisting spinal deformity worsened after surgery and five patients demonstrated a new spinal malalignment. No patient required additional surgery because of progressive spinal deformity. Intramedullary location of the lesion and cervical location of surgery were significantly associated with the development of spinal malalignment, whereas incomplete bony healing of the laminae was not. The reconstruction of the laminar roof using the technique described is safe, well suitable to serve as a standard posterior approach to intraspinal pathologies, and offers distinct advantages over laminectomy. However, some patients, particularly those with intramedullary cervical lesions, could develop spinal malalignment after surgery despite reconstruction of the laminar roof and sufficient bony healing of the laminae.
- 1 August 2004
- Published by Georg Thieme Verlag KG in min - Minimally Invasive Neurosurgery
- Vol. 47 (4) , 221-225
The Supraorbital Keyhole Approach via an Eyebrow Incision for Resection of Tumors around the Sella and the Anterior Skull Base
Objective: This study evaluates the technique, indications, advantages and limitations of the minimal invasive supraorbital keyhole approach via an eyebrow skin incision for resection of tumors around the sella and the anterior skull base. Methods and Results: In 9 patients (5 males, 4 females) different tumors (6 meningiomas, 1 craniopharyngioma, 1 Rathke's cleft cyst and 1 hypophysitis) with a maximum diameter of 30 millimeters were resected via a small eyebrow incision and a supraorbital keyhole craniotomy. Details of the operative procedure include the use of a high-speed drill, a microsaw, bayonet-shaped instruments, careful microsurgical dissection, the use of a neuroendoscope and miniplates for closure. In all patients complete tumor removal was achieved. Mean duration of surgery was 01 h 51 min and mean hospital stay was 8.9 days. There were no significant postoperative complications. Clinical examination and MR imaging after a mean follow-up of 313 days revealed no tumor recurrence and a very satisfying overall functional and cosmetic result in all patients. Conclusion: The eyebrow incision supraorbital keyhole approach proved to be safe, effective and time-sparing. The authors recommend this approach for resection of small tumors around the sella and the anterior skull base in selected cases as a valuable alternative to standard skull base approaches.
- 1 August 2004
- Published by Georg Thieme Verlag KG in min - Minimally Invasive Neurosurgery
- Vol. 47 (4) , 221-225
The Supraorbital Keyhole Approach via an Eyebrow Incision for Resection of Tumors around the Sella and the Anterior Skull Base
Objective: This study evaluates the technique, indications, advantages and limitations of the minimal invasive supraorbital keyhole approach via an eyebrow skin incision for resection of tumors around the sella and the anterior skull base. Methods and Results: In 9 patients (5 males, 4 females) different tumors (6 meningiomas, 1 craniopharyngioma, 1 Rathke's cleft cyst and 1 hypophysitis) with a maximum diameter of 30 millimeters were resected via a small eyebrow incision and a supraorbital keyhole craniotomy. Details of the operative procedure include the use of a high-speed drill, a microsaw, bayonet-shaped instruments, careful microsurgical dissection, the use of a neuroendoscope and miniplates for closure. In all patients complete tumor removal was achieved. Mean duration of surgery was 01 h 51 min and mean hospital stay was 8.9 days. There were no significant postoperative complications. Clinical examination and MR imaging after a mean follow-up of 313 days revealed no tumor recurrence and a very satisfying overall functional and cosmetic result in all patients. Conclusion: The eyebrow incision supraorbital keyhole approach proved to be safe, effective and time-sparing. The authors recommend this approach for resection of small tumors around the sella and the anterior skull base in selected cases as a valuable alternative to standard skull base approaches.
- 1 February 2004
- Vol. 75 (2) , 280-6
False negative findings in intraoperative SEP monitoring: analysis of 658 consecutive neurosurgical cases and review of published reports.
To determine the sensitivity of intraoperative monitoring in neurosurgical operations using somatosensory evoked potentials and to identify reasons for false negative findings and possible settings with an increased risk for monitoring failure. SEP monitoring of 658 neurosurgical operations was analysed. The target of monitoring was the function of a hemisphere in 251 cases, the brain stem in 198 cases, and the spinal cord in 209 cases. In 27 cases (4.1%), monitoring was classified as false negative. Further analysis showed that five of these patients had experienced delayed neurological damage. Among the remaining 22 false negative cases, 14 had a minor neurological deficit and eight had severe neurological damage. Overall sensitivity and negative predictive value of SEP monitoring was 79% and 96%, respectively. For the detection of severe neurological damage the corresponding figures were 91% and 98%. Sensitivity of monitoring varied depending on the target of monitoring and the type of lesion. Monitoring was less likely to detect neurological damage in surgery for infratentorial tumours with brain stem compression, small lesions of the motor cortex, and small vessel damage during aneurysm surgery. SEP monitoring has acceptable sensitivity for detecting neurological damage during different neurosurgical procedures. Distinct settings with an increased risk of monitoring failure can be identified. In these cases measures to enhance the sensitivity of monitoring should be considered.
- 1 February 2004
- Vol. 75 (2) , 280-6
False negative findings in intraoperative SEP monitoring: analysis of 658 consecutive neurosurgical cases and review of published reports.
To determine the sensitivity of intraoperative monitoring in neurosurgical operations using somatosensory evoked potentials and to identify reasons for false negative findings and possible settings with an increased risk for monitoring failure. SEP monitoring of 658 neurosurgical operations was analysed. The target of monitoring was the function of a hemisphere in 251 cases, the brain stem in 198 cases, and the spinal cord in 209 cases. In 27 cases (4.1%), monitoring was classified as false negative. Further analysis showed that five of these patients had experienced delayed neurological damage. Among the remaining 22 false negative cases, 14 had a minor neurological deficit and eight had severe neurological damage. Overall sensitivity and negative predictive value of SEP monitoring was 79% and 96%, respectively. For the detection of severe neurological damage the corresponding figures were 91% and 98%. Sensitivity of monitoring varied depending on the target of monitoring and the type of lesion. Monitoring was less likely to detect neurological damage in surgery for infratentorial tumours with brain stem compression, small lesions of the motor cortex, and small vessel damage during aneurysm surgery. SEP monitoring has acceptable sensitivity for detecting neurological damage during different neurosurgical procedures. Distinct settings with an increased risk of monitoring failure can be identified. In these cases measures to enhance the sensitivity of monitoring should be considered.
- 1 December 2003
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 99 (6) , 986-990
Enhanced stability of somatosensory evoked potentials attained in the median nerve by using temporal electrodes for intraoperative recording in patients in the semisitting position
Findings published in case reports indicate that monitoring of median nerve somatosensory evoked potentials (MN-SSEPs) is unreliable in patients who undergo surgery while in the semisitting position due to the occurrence of changes in the potentials that are unrelated to neurological damage. The present study was designed to test the hypothesis that in these patients MN-SSEPs are more stable when recording electrodes are placed over the temporal region. In 30 patients who underwent surgery in the semisitting position, MN-SSEPs were recorded intraoperatively by using electrodes placed over the temporal region as well as those placed at conventional recording sites. The authors analyzed MN-SSEP amplitudes and latencies at different recording sites and at distinct steps of the monitoring procedure. In 10 of the 30 patients a clinically significant attenuation (> 50%) of MN-SSEP amplitude was observed at conventional recording sites and this was obviously not related to neurological damage. In contrast, no significant changes were observed in MN-SSEPs recorded from electrodes located over the temporal region. In patients who undergo surgery in the semisitting position, the use of additional recording electrodes placed over the temporal region makes intraoperative MN-SSEP monitoring less prone to false-positive alarms and thus enhances the reliability of intraoperative MN-SSEP monitoring.
- 1 December 2003
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 99 (6) , 986-990
Enhanced stability of somatosensory evoked potentials attained in the median nerve by using temporal electrodes for intraoperative recording in patients in the semisitting position
Findings published in case reports indicate that monitoring of median nerve somatosensory evoked potentials (MN-SSEPs) is unreliable in patients who undergo surgery while in the semisitting position due to the occurrence of changes in the potentials that are unrelated to neurological damage. The present study was designed to test the hypothesis that in these patients MN-SSEPs are more stable when recording electrodes are placed over the temporal region. In 30 patients who underwent surgery in the semisitting position, MN-SSEPs were recorded intraoperatively by using electrodes placed over the temporal region as well as those placed at conventional recording sites. The authors analyzed MN-SSEP amplitudes and latencies at different recording sites and at distinct steps of the monitoring procedure. In 10 of the 30 patients a clinically significant attenuation (> 50%) of MN-SSEP amplitude was observed at conventional recording sites and this was obviously not related to neurological damage. In contrast, no significant changes were observed in MN-SSEPs recorded from electrodes located over the temporal region. In patients who undergo surgery in the semisitting position, the use of additional recording electrodes placed over the temporal region makes intraoperative MN-SSEP monitoring less prone to false-positive alarms and thus enhances the reliability of intraoperative MN-SSEP monitoring.
- 1 December 2002
- Published by Elsevier in Clinical Neurophysiology
- Vol. 113 (12) , 1993-1997
Observations on intraoperative somatosensory evoked potential (SEP) monitoring in the semi-sitting position
- 1 December 2002
- Published by Elsevier in Clinical Neurophysiology
- Vol. 113 (12) , 1993-1997
Observations on intraoperative somatosensory evoked potential (SEP) monitoring in the semi-sitting position
- 1 February 2002
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 96 (2) , 255-262
The impact of neurophysiological intraoperative monitoring on surgical decisions: a critical analysis of 423 cases
Object. The aim of this observational clinical study was to analyze the impact of neurophysiological intraoperative monitoring (IOM) on the surgical procedure and to assess the benefits of such monitoring. Methods. Data for 423 patients who underwent neurophysiological IOM with somatosensory evoked potentials and brainstem auditory evoked potentials during neurosurgical procedures were collected prospectively. The patients were classified into one of five groups according to the findings of IOM, the intervention following a monitoring alarm, and the patient's postoperative neurological condition. These groups were as follows: patients with true-positive findings with intervention (42 cases, 9.9%), those with true-positive findings without intervention (42 cases, 9.9%), those with false-positive findings (nine cases, 2.1%), those with false-negative findings (16 cases, 3.8%), and those with true-negative findings (314 cases, 74.2%). Different interventions followed an event identified with monitoring. These interventions were related to dissection in 17 cases, to perfusion pressure in 11, to a limitation of the surgical procedure in five, to vessel clipping in four, to vasospasm in three, and to retraction in one case. In one case the surgical procedure was abandoned. A critical analysis and cautious estimation of the interventions revealed that IOM was helpful in preventing a postoperative deficit in 5.2% of the monitored cases. Conclusions. For critical analysis of the benefits of IOM one must evaluate not only the findings of IOM and the patient's postoperative neurological condition but also the intraoperative findings and surgical interventions following a monitoring alarm. Evidence is presented that IOM is helpful in preventing a postoperative deficit.
- 1 February 2002
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 96 (2) , 255-262
The impact of neurophysiological intraoperative monitoring on surgical decisions: a critical analysis of 423 cases
Object. The aim of this observational clinical study was to analyze the impact of neurophysiological intraoperative monitoring (IOM) on the surgical procedure and to assess the benefits of such monitoring. Methods. Data for 423 patients who underwent neurophysiological IOM with somatosensory evoked potentials and brainstem auditory evoked potentials during neurosurgical procedures were collected prospectively. The patients were classified into one of five groups according to the findings of IOM, the intervention following a monitoring alarm, and the patient's postoperative neurological condition. These groups were as follows: patients with true-positive findings with intervention (42 cases, 9.9%), those with true-positive findings without intervention (42 cases, 9.9%), those with false-positive findings (nine cases, 2.1%), those with false-negative findings (16 cases, 3.8%), and those with true-negative findings (314 cases, 74.2%). Different interventions followed an event identified with monitoring. These interventions were related to dissection in 17 cases, to perfusion pressure in 11, to a limitation of the surgical procedure in five, to vessel clipping in four, to vasospasm in three, and to retraction in one case. In one case the surgical procedure was abandoned. A critical analysis and cautious estimation of the interventions revealed that IOM was helpful in preventing a postoperative deficit in 5.2% of the monitored cases. Conclusions. For critical analysis of the benefits of IOM one must evaluate not only the findings of IOM and the patient's postoperative neurological condition but also the intraoperative findings and surgical interventions following a monitoring alarm. Evidence is presented that IOM is helpful in preventing a postoperative deficit.
- 1 January 2002
- Published by Taylor & Francis in Brain Injury
- Vol. 16 (4) , 323-330
Early seizures following non-penetrating traumatic brain injury in adults: risk factors and clinical significance
In the literature dissenting data are obtained about risk factors for early post-traumatic seizures and their impact on outcome. This study was conducted to obtain more information about the clinical significance of early seizures and their possible impact on the treatment of traumatic brain injury. A consecutive series of 1868 adult patients with head injury were analysed retrospectively. Demographic data of the patients, characteristics of the injury, and findings on CT scan were recorded. Risk factors for early post-traumatic seizures were identified using univariate statistics. A multivariate logistic regression was performed to look for interaction of different variables. The impact of early post-traumatic seizures on outcome was examined in an analogous way. Chronic alcohol abuse, subdural haematoma and brain contusion were identified as independent risk factors for early post-traumatic seizures. A significant association of early post-traumatic seizures with an unfavourable outcome was observed, but this effect was small compared to other variables. Early post-traumatic seizures appear to be an acute reaction of the brain to cortical damage with little independent impact on the management of head injury.
- 1 January 2002
- Published by Taylor & Francis in Brain Injury
- Vol. 16 (4) , 323-330
Early seizures following non-penetrating traumatic brain injury in adults: risk factors and clinical significance
In the literature dissenting data are obtained about risk factors for early post-traumatic seizures and their impact on outcome. This study was conducted to obtain more information about the clinical significance of early seizures and their possible impact on the treatment of traumatic brain injury. A consecutive series of 1868 adult patients with head injury were analysed retrospectively. Demographic data of the patients, characteristics of the injury, and findings on CT scan were recorded. Risk factors for early post-traumatic seizures were identified using univariate statistics. A multivariate logistic regression was performed to look for interaction of different variables. The impact of early post-traumatic seizures on outcome was examined in an analogous way. Chronic alcohol abuse, subdural haematoma and brain contusion were identified as independent risk factors for early post-traumatic seizures. A significant association of early post-traumatic seizures with an unfavourable outcome was observed, but this effect was small compared to other variables. Early post-traumatic seizures appear to be an acute reaction of the brain to cortical damage with little independent impact on the management of head injury.
- 1 January 1999
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 21 (6) , 429-433
Observations on intraoperative monitoring of visual pathways using steady-state visual evoked potentials
Ng the modality of steady-state visual evoked potentials. Methods: In 30 cases with non-cranial surgery steady-state visual evoked potentials were recorded in the awake and surgically anaesthetized patient using total intravenous anaesthesia. For stimulation, goggles with red light-emitting diodes at a frequency of 8.5 Hz were used. A two-channel recording with silver cup electrodes at Oz to Fz and Oz to earlobe was used. All traces were analysed for the presence of the characteristically sinusoidal waveform and amplitudes and latencies of the main peaks were measured. Results: Recordings during surgery demonstrated a minor latency prolongation of 16% and a more pronounced amplitude attenuation of 67% compared to the recordings in the awake patients. These differences were statistically significant (paired t-test, P < 0.001). In surgically anaesthetized patients steady-state visual evoked potentials showed a relatively high intra- and interindividual variability. In four of 30 patients completely stable recordings were obtained, whereas in 14 patients identifiable waves were recordable in only less than 50% of the intraoperative traces. Of the total 1360 traces recorded intraoperatively clearly identifiable steady-state visual evoked potentials patterns were present in 56% of the traces. There was no correlation between the magnitude of the evoked potential amplitude and its stability in intraoperative recordings. Conclusions: We conclude from this study, that steady-state visual evoked potential recordings in the surgically anaesthetized patient appeared to be more stable compared to our earlier findings using transient visual evoked potentials. However, further efforts are necessary to improve the stability of the recordings during surgery and thus allow for a more reliable intraoperative monitoring of visual pathways in routine clinical practice....
- 1 January 1999
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 21 (6) , 429-433
Observations on intraoperative monitoring of visual pathways using steady-state visual evoked potentials
Ng the modality of steady-state visual evoked potentials. Methods: In 30 cases with non-cranial surgery steady-state visual evoked potentials were recorded in the awake and surgically anaesthetized patient using total intravenous anaesthesia. For stimulation, goggles with red light-emitting diodes at a frequency of 8.5 Hz were used. A two-channel recording with silver cup electrodes at Oz to Fz and Oz to earlobe was used. All traces were analysed for the presence of the characteristically sinusoidal waveform and amplitudes and latencies of the main peaks were measured. Results: Recordings during surgery demonstrated a minor latency prolongation of 16% and a more pronounced amplitude attenuation of 67% compared to the recordings in the awake patients. These differences were statistically significant (paired t-test, P < 0.001). In surgically anaesthetized patients steady-state visual evoked potentials showed a relatively high intra- and interindividual variability. In four of 30 patients completely stable recordings were obtained, whereas in 14 patients identifiable waves were recordable in only less than 50% of the intraoperative traces. Of the total 1360 traces recorded intraoperatively clearly identifiable steady-state visual evoked potentials patterns were present in 56% of the traces. There was no correlation between the magnitude of the evoked potential amplitude and its stability in intraoperative recordings. Conclusions: We conclude from this study, that steady-state visual evoked potential recordings in the surgically anaesthetized patient appeared to be more stable compared to our earlier findings using transient visual evoked potentials. However, further efforts are necessary to improve the stability of the recordings during surgery and thus allow for a more reliable intraoperative monitoring of visual pathways in routine clinical practice....