Lothar R. Schad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lothar R. Schad has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Edgar Müller
2 shared publications- Marco Essig
Department of Radiology, University of Manitoba, Winnipeg, Canada
2 shared publications - Michael Bock
Division of Medical Physics, Department of Diagnostic and Interventional Radiology Medical Center – University of Freiburg, Faculty of Medicine – University of Freiburg Freiburg Germany
2 shared publications Walter J. Lorenz
2 shared publicationsAndreas W. Hartlep
Forschungsschwerpunkt Radiologische Diagnostik und Therapie, Deutsches Krebsforschungszentrum (DKFZ), 69120 Heidelberg, Germany
1 shared publicationChristian M. Wacker
Forschungsschwerpunkt Radiologische Diagnostik und Therapie, Deutsches Krebsforschungszentrum (DKFZ), Heidelberg, Germany
1 shared publication
Latest Publications
- 2 August 2007
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 17 (3) , 205-211
Ein experimentelles Organmodell für die MR-Bildgebung
- 2 August 2007
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 17 (3) , 205-211
Ein experimentelles Organmodell für die MR-Bildgebung
- Open Access
- 30 June 2004
- Published by Taylor & Francis in Dialogues in clinical neuroscience
- Vol. 6 (2) , 235-242
Problems in texture analysis with magnetic resonance imaging
Since its introduction in the 1930s, magnetic resonance imaging (MRI) has become recognized as a powerful in vivo diagnostic tool. The objective of this article is to discuss developments in quantitative MRI - and particularly texture analysis - that maximize diagnostic information, A fundamental pa …
- 30 June 2004
- Published by Taylor & Francis in Dialogues in clinical neuroscience
- Vol. 6 (2) , 235-242
Open AccessProblems in texture analysis with magnetic resonance imaging
Since its introduction in the 1930s, magnetic resonance imaging (MRI) has become recognized as a powerful in vivo diagnostic tool. The objective of this article is to discuss developments in quantitative MRI - and particularly texture analysis - that maximize diagnostic information, A fundamental pa …
- 1 September 2002
- Published by Springer Nature in Der Radiologe
- Vol. 42 (9) , 756-764
Funktionelle Magnetresonanztomographie (fMRT)
- 1 September 2002
- Published by Springer Nature in Der Radiologe
- Vol. 42 (9) , 756-764
Funktionelle Magnetresonanztomographie (fMRT)
- 1 June 2002
- Published by Wiley in Drug Development Research
- Vol. 56 (2) , 51-56
Progressive medial temporal lobe changes in Alzheimer's disease revealed by quantitative MRI: potential use for monitoring of drug-related changes
- 1 June 2002
- Published by Wiley in Drug Development Research
- Vol. 56 (2) , 51-56
Progressive medial temporal lobe changes in Alzheimer's disease revealed by quantitative MRI: potential use for monitoring of drug-related changes
- Open Access
- 27 November 2001
- Published by Wiley in NMR in Biomedicine
- Vol. 14 (7-8) , 478-483
Improved target volume characterization in stereotactic treatment planning of brain lesions by using high‐resolution BOLD MR‐venography
In this methodological paper I report the stereotactic correlation of different magnetic resonance imaging (MRI) techniques [MR angiography (MRA), MRI, blood bolus tagging (STAR), functional MRI, and high‐resolution BOLD venography (HRBV)] in patients with cerebral arterio‐venous malformations (AVM) and brain tumors. The patient's head was fixed in a stereotactic localization system which is usable in both MR‐systems and linear accelerator installations. Using phantom measurements global geometric MR image distortions can be ‘corrected’ (reducing displacements to the size of a pixel) by calculations based on modeling the distortion as a fourth‐order two‐dimensional polynomial. Further object‐induced local distortions can be corrected by additionally measured field maps. Using this method multimodality matching could be performed automatically as long as all images are acquired in the same examination and the patient is sufficiently immobilized to allow precise definition of the target volume. Information about the hemodynamics of the AVM was provided by a dynamic MRA with the STAR technique, leading to an improved definition of the size of the nidus, the origin of the feeding arteries, whereas HRBV imaging yielded detailed and improved information about the venous pattern and drainage. In addition, functional MRI was performed in patients with lesions close to the primary motor cortex area, leading to an improved definition of structures at risk for the high‐dose application in radiosurgery. In patients with brain tumors the potential of HRBV to probe tumor angiogenesis and its use in intensity‐modulated treatment planning is still hampered by the open question of how to translate a BOLD signal pattern measured in the tumor to a dose distribution, which should be addressed in future studies. Copyright © 2001 John Wiley & Sons, Ltd.
- 27 November 2001
- Published by Wiley in NMR in Biomedicine
- Vol. 14 (7-8) , 478-483
Open AccessImproved target volume characterization in stereotactic treatment planning of brain lesions by using high‐resolution BOLD MR‐venography
In this methodological paper I report the stereotactic correlation of different magnetic resonance imaging (MRI) techniques [MR angiography (MRA), MRI, blood bolus tagging (STAR), functional MRI, and high‐resolution BOLD venography (HRBV)] in patients with cerebral arterio‐venous malformations (AVM) and brain tumors. The patient's head was fixed in a stereotactic localization system which is usable in both MR‐systems and linear accelerator installations. Using phantom measurements global geometric MR image distortions can be ‘corrected’ (reducing displacements to the size of a pixel) by calculations based on modeling the distortion as a fourth‐order two‐dimensional polynomial. Further object‐induced local distortions can be corrected by additionally measured field maps. Using this method multimodality matching could be performed automatically as long as all images are acquired in the same examination and the patient is sufficiently immobilized to allow precise definition of the target volume. Information about the hemodynamics of the AVM was provided by a dynamic MRA with the STAR technique, leading to an improved definition of the size of the nidus, the origin of the feeding arteries, whereas HRBV imaging yielded detailed and improved information about the venous pattern and drainage. In addition, functional MRI was performed in patients with lesions close to the primary motor cortex area, leading to an improved definition of structures at risk for the high‐dose application in radiosurgery. In patients with brain tumors the potential of HRBV to probe tumor angiogenesis and its use in intensity‐modulated treatment planning is still hampered by the open question of how to translate a BOLD signal pattern measured in the tumor to a dose distribution, which should be addressed in future studies. Copyright © 2001 John Wiley & Sons, Ltd.
- 1 March 1999
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 8 (1) , 48-54
BOLD-MRI in ten patients with coronary artery disease: evidence for imaging of capillary recruitment in myocardium supplied by the stenotic artery
Changes of myocardial oxygenation can be studied by measurements of the apparent transverse relaxation time T2*, which is correlated with the oxygenation state of hemoglobin. In this study, ten patients with coronary artery disease (CAD) underwent blood oxygenation level dependent (BOLD) T2* measurements using a segmented gradient echo pulse sequence with ten echoes. T2* measurements were performed in a single short-axis slice of the heart at rest and under pharmacological stress with dipyridamole (DIP), which increases myocardial blood flow. For comparison, all patients underwent X-ray angiography and stress-echocardiography within 4 days after the MR exam. In one patient, MR examination was repeated 10 weeks after percutaneous transluminal coronary angioplasty (PTA). In the differential T2* maps, expected ischemic areas of myocardium were identified in six patients. In these regions, T2* values (30±8 ms) were significantly reduced when compared to the remaining myocardium (48±9 ms, PT2* within the ischemic myocardium (from 26±1 to 29±1 ms before PTA versus 26±1 to 31±4 ms after PTA, P<0.001).
- 1 March 1999
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 8 (1) , 48-54
BOLD-MRI in ten patients with coronary artery disease: evidence for imaging of capillary recruitment in myocardium supplied by the stenotic artery
Changes of myocardial oxygenation can be studied by measurements of the apparent transverse relaxation time T2*, which is correlated with the oxygenation state of hemoglobin. In this study, ten patients with coronary artery disease (CAD) underwent blood oxygenation level dependent (BOLD) T2* measurements using a segmented gradient echo pulse sequence with ten echoes. T2* measurements were performed in a single short-axis slice of the heart at rest and under pharmacological stress with dipyridamole (DIP), which increases myocardial blood flow. For comparison, all patients underwent X-ray angiography and stress-echocardiography within 4 days after the MR exam. In one patient, MR examination was repeated 10 weeks after percutaneous transluminal coronary angioplasty (PTA). In the differential T2* maps, expected ischemic areas of myocardium were identified in six patients. In these regions, T2* values (30±8 ms) were significantly reduced when compared to the remaining myocardium (48±9 ms, PT2* within the ischemic myocardium (from 26±1 to 29±1 ms before PTA versus 26±1 to 31±4 ms after PTA, P<0.001).
- 1 October 1998
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 16 (8) , 989-991
Comparison of functional MR-venography and EPI-BOLD fMRI at 1.5 t
- 1 October 1998
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 16 (8) , 989-991
Comparison of functional MR-venography and EPI-BOLD fMRI at 1.5 t
- 1 January 1997
- Vol. 412, 43-6
Hyperpolarized gases--a new type of MR contrast agents?
The nuclear spin polarization of noble gases can be strongly enhanced by laser optical pumping followed by electron-nuclear polarization transfer. Direct optical pumping of metastable 3He atoms has been shown to produce enormous polarization in the order of 0.4-0.6. This is about 10(5) times greater than the polarization of water protons at thermal equilibrium used at conventional MR imaging. We demonstrate that hyperpolarized 3He gas can be applied to nuclear MR imaging of human organs with air-filled spaces. In vivo 3He MR experiments were performed in a whole-body MR scanner with a superconducting magnet ramped down to 0.8 T and at 1.5 T using a double resonant Helmholtz coil operating at 63.6 and 48.6 MHz for 1H and 3He, respectively. Anatomical details of the lungs of a volunteer were visualized with the FLASH technique demonstrating the potential of the method for fast imaging of airways in the human body and for pulmonary ventilation studies.
- 1 January 1997
- Vol. 412, 43-6
Hyperpolarized gases--a new type of MR contrast agents?
The nuclear spin polarization of noble gases can be strongly enhanced by laser optical pumping followed by electron-nuclear polarization transfer. Direct optical pumping of metastable 3He atoms has been shown to produce enormous polarization in the order of 0.4-0.6. This is about 10(5) times greater than the polarization of water protons at thermal equilibrium used at conventional MR imaging. We demonstrate that hyperpolarized 3He gas can be applied to nuclear MR imaging of human organs with air-filled spaces. In vivo 3He MR experiments were performed in a whole-body MR scanner with a superconducting magnet ramped down to 0.8 T and at 1.5 T using a double resonant Helmholtz coil operating at 63.6 and 48.6 MHz for 1H and 3He, respectively. Anatomical details of the lungs of a volunteer were visualized with the FLASH technique demonstrating the potential of the method for fast imaging of airways in the human body and for pulmonary ventilation studies.
- 1 January 1995
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 5 (4) , 205-207
Echo Planar Imaging on a Standard 1.5 Tesla Imager
- 1 January 1995
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 5 (4) , 205-207
Echo Planar Imaging on a Standard 1.5 Tesla Imager
- 1 January 1993
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 3 (2) , 88-91
Functional Magnetic Resonance Imaging of Motoric Stimulation Measured at 1.5 Tesla
- 1 January 1993
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 3 (2) , 88-91
Functional Magnetic Resonance Imaging of Motoric Stimulation Measured at 1.5 Tesla