BPBertrand Prunet

Bertrand Prunet

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bertrand Prunet has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Management of septic shock in intermediate care unit

    by Eric Meaudre, Cédric Nguyen, Claire Contargyris, Ambroise Montcriol, Erwan D’aRanda, Pierre Esnault, Mourad Bensalah, Bertrand Prunet, Julien Bordes, Philippe Goutorbe


  • Vittel criteria for severe trauma triage: Characteristics of over-triage

    by Jean Cotte, Fredrik Courjon, Sébastien Beaume, Bertrand Prunet, Julien Bordes, Cédric N’Guyen, Claire Contargyris, Guillaume Lacroix, Ambroise Montcriol, Eric Kaiser, et al.


  • Open Access

    Leaks can dramatically decrease FiO2 on home ventilators: a bench study

    by Philippe Goutorbe, Erwan Daranda, Yves Asencio, Pierre Esnault, Bertrand Prunet, Julien Bordes, Bruno Palmier, Eric Meaudre

    Long term oxygen therapy improves survival in hypoxemic patients with chronic obstructive pulmonary disease (COPD). Because pressure support ventilation with a home care ventilator is largely unsupervised, there is considerable risk of leakage occurring, which could affect delivered FiO2. We have therefore conducted a bench study in order to measure the effect of different levels of O2 supply and degrees of leakage on delivered FiO2. Ventilator tested: Legendair® (Airox™, Pau, France). Thirty-six measures were performed in each four ventilators with zero, 5 and 10 l.min-1 leakage and 1,2,4 and 8 l O2 flow.


  • Open Access

    Evaluation of early mini-bronchoalveolar lavage in the diagnosis of health care-associated pneumonia: a prospective study

    by Guillaume Lacroix, Bertrand Prunet, Julien Bordes, Nathalie Cabon-Asencio, Yves Asencio, Tiphaine Gaillard, Sandrine Pons, Erwan D'ARanda, Delphine Kerebel, Eric Meaudre, et al.

    Introduction Health care-associated pneumonia (HCAP) has been proposed as a new category of respiratory infection to identify patients at risk of multidrug-resistant (MDR) pathogens. The American Thoracic Society's recommendation for HCAP treatment is to use broad-spectrum and multiple antibiotics. However, this strategy may be economically expensive and promote antimicrobial resistance when a multisensitive pathogen is not identified. Methods We prospectively included all patients presenting with HCAP in the emergency department. Blood cultures and fiberoptic bronchoscope-guided distal protected small volume bronchoalveolar lavage (FODP mini-BAL) were performed in each patient. Empirical antibiotic therapy was adapted when microbiological findings were available. The primary objective was to assess whether FODP mini-BAL is more efficient than blood cultures in identifying pathogens with the ratio of identification between both techniques as principal criteria. Results We included 54 patients with HCAP. Pathogens were identified in 46.3% of cases using mini-BAL and in 11.1% of cases using blood cultures (P P Conclusions FODP mini-BAL was more efficient than blood cultures for identifying pathogens in patients presenting with HCAP. When bacteriological identification was obtained, antibiotic therapy was adapted in 100% of cases. See related letter by Sircar et al.,http://ccforum.com/content/17/2/428


  • Open Access

    Protective ventilation in ARDS: as soon as possible. An immediate use of HFOV

    by Philippe Ph Goutorbe, Yves Y Asencio, Julien J Bordes, Ambroise A Montcriol, Bertrand B Prunet, Eric E Meaudre

    To report the immediate use of High-Frequency Oscillatory ventilation in an adult acute respiratory distress syndrome. Case report. Intensive care unit at the Military Teaching Hospital of Toulon. A 64-yr-old Caucasian male who developed acute respiratory distress syndrome in the course of severe falciparum malaria. Initial use of HFO to minimise ventilator-induced lung injury. Rapid improvement of PaO2/fraction of inspired oxygen from 172 mmHg (NIV) to 310 mmHg with HFO. No ventilator-induced injury on CT scan after 5 days of invasive ventilation. In contrast with previous studies, we successfully used lung protective ventilation with HFO immediately. Further studies, with immediate, rather than rescue use of HFO ventilation, are needed.


  • A Prospective Randomized Trial of Two Safety Peripheral Intravenous Catheters

    by Bertrand Prunet, Eric Meaudre, Ambroise Montcriol, Yves Asencio, Julien Bordes, Guillaume Lacroix, Eric Kaiser

    To reduce the risk of accidental needlestick injuries, first active then passive safety devices were developed on IV catheters. However, whether these catheters are easy to implement and really protect personnel from accidental needlestick is untested. In this prospective randomized survey, we compared a passive safety catheter with an active safety catheter and a nonsafety classic catheter. The main objective was to evaluate the difficulty of inserting the catheters in terms of the number of insertion failures, difficulties introducing the catheter and withdrawing the needle, and the normality of the blood reflux in the delivery system. The second objective was to determine the degree of exposure to patients' blood evaluated as the number of exposures of the staff and blood splashes of the environment, and the staff's sense of protection. Seven hundred fifty-nine assessment cards were collected. The number of failures for the three catheter groups was similar and not statistically different. Introduction of the catheter was more difficult with the active safety catheter. Needle withdrawal was more difficult with the passive safety catheter. The blood reflux was abnormal more often with the safety catheters. The staff's exposure was more frequent with the active safety catheter. The number of blood splashes was more common with the safety catheters. Safety catheters are not superior with regard to failure rate in the catheter's placement. Users feel better protected, but find the use of safety catheters more difficult, and their handling generates more splashing of blood into the environment. The passive safety catheter is more efficient than the active safety catheter with regard to ease of introduction of the catheter into the vein and the staff's exposure to the patient's blood.