David Sonnenfroh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David Sonnenfroh has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
M. Allen
Physical Sciences Inc. (United States)
6 shared publicationsMark G. Allen
The authors are with Physical Sciences Inc., 20 New England Business Center, Andover, Massachusetts 01810-0000
3 shared publicationsT. Parker
Physical Sciences, Inc., Andover, MA
3 shared publicationsB. Upschulte
Physical Sciences, Inc., Andover, MA
2 shared publicationsP. Mulhall
Physical Sciences, Inc., Andover, MA
2 shared publicationsR. Foutter
Physical Sciences, Inc., Andover, MA
2 shared publications
Latest Publications
- Open Access
Field Test of a Remote Multi-Path CLaDS Methane Sensor
Existing technologies for quantifying methane emissions are often limited to single point sensors, making large area environmental observations challenging. We demonstrate the operation of a remote, multi-path system using Chirped Laser Dispersion Spectroscopy (CLaDS) for quantification of atmospheric methane concentrations over extended areas, a technology that shows potential for monitoring emissions from wetlands.
Open AccessField Test of a Remote Multi-Path CLaDS Methane Sensor
Existing technologies for quantifying methane emissions are often limited to single point sensors, making large area environmental observations challenging. We demonstrate the operation of a remote, multi-path system using Chirped Laser Dispersion Spectroscopy (CLaDS) for quantification of atmospheric methane concentrations over extended areas, a technology that shows potential for monitoring emissions from wetlands.
- 6 November 2010
- Published by Springer Nature in Applied Physics B
- Vol. 102 (2) , 407-416
Diode laser-based sensor for high precision measurements of ambient CO2 in network applications
- 6 November 2010
- Published by Springer Nature in Applied Physics B
- Vol. 102 (2) , 407-416
Diode laser-based sensor for high precision measurements of ambient CO2 in network applications
- 18 October 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6386, 63860Q-63860
A mid-IR ICL-based sensor for field measurements of ambient CH 4
We are developing a mid-IR ICL-based sensor for field measurements of ambient CH4. We describe some of the design considerations for this sensor. Our sensor uses a Type II Quantum Cascade Laser (or Interband Cascade Laser, ICL) operating near 3.3 μm to monitor a well-isolated line in the υ3 fundamental band of CH4. The ICL operates in cw mode at cryogenic temperature. The sensor consists of two major components, an optical breadboard containing the laser, transfer optics, sample cell, and detectors, and an instrumentation module containing power supplies and system control computer. Light from the laser is collimated using a reflective microscope objective and transported to a multipass cell via a simple optics train. The multipass cell provides an optical path of ~7 meters in an 0.25 m base path. The spectrometer uses TE-cooled InAs detectors along with our Balanced Ratiometric Detection. Our measured precision for CH4 is 15 ppbv for a 60 sec integration time. We report on additional sensor characterization and data from recent field trials at two facilities maintained by the University of New Hampshire.
- 18 October 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6386, 63860Q-63860
A mid-IR ICL-based sensor for field measurements of ambient CH 4
We are developing a mid-IR ICL-based sensor for field measurements of ambient CH4. We describe some of the design considerations for this sensor. Our sensor uses a Type II Quantum Cascade Laser (or Interband Cascade Laser, ICL) operating near 3.3 μm to monitor a well-isolated line in the υ3 fundamental band of CH4. The ICL operates in cw mode at cryogenic temperature. The sensor consists of two major components, an optical breadboard containing the laser, transfer optics, sample cell, and detectors, and an instrumentation module containing power supplies and system control computer. Light from the laser is collimated using a reflective microscope objective and transported to a multipass cell via a simple optics train. The multipass cell provides an optical path of ~7 meters in an 0.25 m base path. The spectrometer uses TE-cooled InAs detectors along with our Balanced Ratiometric Detection. Our measured precision for CH4 is 15 ppbv for a 60 sec integration time. We report on additional sensor characterization and data from recent field trials at two facilities maintained by the University of New Hampshire.
- 1 November 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (31) , 6635-6643
Quantum cascade laser sensor for SO_2 and SO_3 for application to combustor exhaust streams
We have demonstrated a high-sensitivity, room-temperature quantum-cascade (QC) laser sensor for detection of SO2 and SO3 under conditions relevant to aircraft test combustor exhaust. Two QC lasers probe infrared absorption features at 7.50 and 7.16 μm for SO2 and SO3, respectively, with a common dual-beam detection system. We inferred a noise-equivalent absorbance of ~1 × 10−4 Hz−1/2. We have demonstrated detection limits for both SO2 and SO3 of 1–2 ppmv m/Hz1/2 (where ppmv is parts in 106 by volume) for 300 torr, elevated temperature, and path lengths near 1 m. This level of sensitivity permits measurement of 2 and SO3 at these conditions with modest signal averaging.
- 1 November 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (31) , 6635-6643
Quantum cascade laser sensor for SO_2 and SO_3 for application to combustor exhaust streams
We have demonstrated a high-sensitivity, room-temperature quantum-cascade (QC) laser sensor for detection of SO2 and SO3 under conditions relevant to aircraft test combustor exhaust. Two QC lasers probe infrared absorption features at 7.50 and 7.16 μm for SO2 and SO3, respectively, with a common dual-beam detection system. We inferred a noise-equivalent absorbance of ~1 × 10−4 Hz−1/2. We have demonstrated detection limits for both SO2 and SO3 of 1–2 ppmv m/Hz1/2 (where ppmv is parts in 106 by volume) for 300 torr, elevated temperature, and path lengths near 1 m. This level of sensitivity permits measurement of 2 and SO3 at these conditions with modest signal averaging.
- 20 February 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (6) , 812-820
Application of balanced detection to absorption measurements of trace gases with room-temperature, quasi-cw quantum-cascade lasers
Distributed-feedback quantum-cascade (QC) lasers are expected to form the heart of the next-generation mid-IR laser absorption spectrometers, especially as they are applied to measurements of trace gases in a variety of environments. The incorporation of room-temperature-operable, single-mode QC lasers should result in highly compact and rugged sensors for real-world applications. We report preliminary results on the performance of a laser absorption spectrometer that uses a QC laser operating at room temperature in a quasi-cw mode in conjunction with balanced ratiometric detection. We have demonstrated sensitivities for N2O [10 parts in 106 volume-mixing ratio for a 1-m path (ppmv-m)] and NO [520 parts in 109 volume-mixing ratio for a 1-m path (ppbv-m)] at 5.4 µm. System improvements are described that are expected to result in a 2 orders of magnitude increase in sensitivity.
- 20 February 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (6) , 812-820
Application of balanced detection to absorption measurements of trace gases with room-temperature, quasi-cw quantum-cascade lasers
Distributed-feedback quantum-cascade (QC) lasers are expected to form the heart of the next-generation mid-IR laser absorption spectrometers, especially as they are applied to measurements of trace gases in a variety of environments. The incorporation of room-temperature-operable, single-mode QC lasers should result in highly compact and rugged sensors for real-world applications. We report preliminary results on the performance of a laser absorption spectrometer that uses a QC laser operating at room temperature in a quasi-cw mode in conjunction with balanced ratiometric detection. We have demonstrated sensitivities for N2O [10 parts in 106 volume-mixing ratio for a 1-m path (ppmv-m)] and NO [520 parts in 109 volume-mixing ratio for a 1-m path (ppbv-m)] at 5.4 µm. System improvements are described that are expected to result in a 2 orders of magnitude increase in sensitivity.
- 1 September 1998
- Published by Springer Nature in Applied Physics B
- Vol. 67 (3) , 275-282
In-situ sensing of tropospheric water vapor using an airborne near-IR diode laser hygrometer
- 1 September 1998
- Published by Springer Nature in Applied Physics B
- Vol. 67 (3) , 275-282
In-situ sensing of tropospheric water vapor using an airborne near-IR diode laser hygrometer
- 1 January 1998
- Published by Optica Publishing Group
- p. LTuD.5
In situ Sensing of Atmospheric Trace Gases Using Airborne Near-IR Diode Laser Sensors
Over the last few years, there has been considerable effort at Physical Sciences Inc. (PSI) and elsewhere to develop ultrasensitive trace gas sensors for in situ monitoring of several important atmospheric species including H2O, CO2 and CH4. At PSI, high performance field sensors have been created by combining near-IR diode laser absorption with balanced ratiometric detection. One such sensor is a laser hygrometer developed for NASA which is capable of monitoring water vapor from ground level to the tropopause. The laser hygrometer monitors water vapor through absorption via a strong, isolated line at 7181.172 cm−1 in the ν1 + ν3 combination band. Through a series of laboratory measurements, we have demonstrated a sensitivity of 2 × 1012 molecules cm−3 which corresponds to ~0.3 ppmv water vapor at typical mid-latitude tropopause conditions (12 km or 40 kft) using a 50 cm absorption pathlength. We have also demonstrated a dynamic range of 4 orders of magnitude and a measurement rate of 10 Hz. The hygrometer uses a unique, compact, external air probe for true in situ sampling, thereby obviating well-known limitations in time-response and sensitivity imposed by extractive air sampling systems.
- 1 January 1998
- Published by Optica Publishing Group
- p. LTuD.5
In situ Sensing of Atmospheric Trace Gases Using Airborne Near-IR Diode Laser Sensors
Over the last few years, there has been considerable effort at Physical Sciences Inc. (PSI) and elsewhere to develop ultrasensitive trace gas sensors for in situ monitoring of several important atmospheric species including H2O, CO2 and CH4. At PSI, high performance field sensors have been created by combining near-IR diode laser absorption with balanced ratiometric detection. One such sensor is a laser hygrometer developed for NASA which is capable of monitoring water vapor from ground level to the tropopause. The laser hygrometer monitors water vapor through absorption via a strong, isolated line at 7181.172 cm−1 in the ν1 + ν3 combination band. Through a series of laboratory measurements, we have demonstrated a sensitivity of 2 × 1012 molecules cm−3 which corresponds to ~0.3 ppmv water vapor at typical mid-latitude tropopause conditions (12 km or 40 kft) using a 50 cm absorption pathlength. We have also demonstrated a dynamic range of 4 orders of magnitude and a measurement rate of 10 Hz. The hygrometer uses a unique, compact, external air probe for true in situ sampling, thereby obviating well-known limitations in time-response and sensitivity imposed by extractive air sampling systems.