Juergen H. Massig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Juergen H. Massig has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Alexander Stadelmaier
Theodor-Storm-Strasse 4, D 73529 Schwäbisch Gmünd, Germany
1 shared publicationBernd Lingelbach
J. Massig, E. Lingelbach, and B. Lingelbach are with the Fachbereich Optik und Mechatronik, Aalen University of Applied Science, Beethovenstrasse 1, Aalen D73430, Germany
1 shared publicationElke Lingelbach
J. Massig, E. Lingelbach, and B. Lingelbach are with the Fachbereich Optik und Mechatronik, Aalen University of Applied Science, Beethovenstrasse 1, Aalen D73430, Germany
1 shared publicationJoachim Heppner
J. H. Massigis with Aalen University of Applied Science, Beethovenstrasse 1, D-73430 Aalen, Germany.J. Heppner is with Carl Zeiss, Postfach, D-73446 Oberkochen, Germany
1 shared publication
Latest Publications
- 20 April 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (12) , 2281-2287
Videokeratoscope for accurate and detailed measurement of the cornea surface
A videokeratoscope based on the imaging of a gridlike pattern is introduced. Unlike conventional video-keratoscopes that rely on Placido disks, the new measurement principle allows an exact reconstruction of the surface and the display of fine details. The experimental instrument was tested on precision glass spheres; the maximum error of the height data was less than 3 µm. The sensitivity and the potential to resolve fine details were demonstrated with irregular surfaces of specially prepared contact lenses. Structures with height deviations of 0.1 µm are well identifiable. The eyes of 18 individuals were investigated, and fine structures were found on these cornea surfaces. Conventional videokeratoscopes do not resolve such detail.
- 20 April 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (12) , 2281-2287
Videokeratoscope for accurate and detailed measurement of the cornea surface
A videokeratoscope based on the imaging of a gridlike pattern is introduced. Unlike conventional video-keratoscopes that rely on Placido disks, the new measurement principle allows an exact reconstruction of the surface and the display of fine details. The experimental instrument was tested on precision glass spheres; the maximum error of the height data was less than 3 µm. The sensitivity and the potential to resolve fine details were demonstrated with irregular surfaces of specially prepared contact lenses. Structures with height deviations of 0.1 µm are well identifiable. The eyes of 18 individuals were investigated, and fine structures were found on these cornea surfaces. Conventional videokeratoscopes do not resolve such detail.
- 15 December 2002
- Published by Optica Publishing Group in Optics Letters
- Vol. 27 (24) , 2179-2181
Digital off-axis holography with a synthetic aperture
The use of a synthetic aperture is demonstrated as part of an off-axis setup for digital holography. The aperture was constructed from camera recordings at nine different positions. An algorithm to reconstruct object sections, which requires only moderate computer memory, was used. The result shows strongly improved resolution.
- 15 December 2002
- Published by Optica Publishing Group in Optics Letters
- Vol. 27 (24) , 2179-2181
Digital off-axis holography with a synthetic aperture
The use of a synthetic aperture is demonstrated as part of an off-axis setup for digital holography. The aperture was constructed from camera recordings at nine different positions. An algorithm to reconstruct object sections, which requires only moderate computer memory, was used. The result shows strongly improved resolution.
- 1 May 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (13) , 2081-2088
Fringe-pattern analysis with high accuracy by use of the Fourier-transform method: theory and experimental tests
The Fourier-transform method is often used to evaluate fringe patterns. The fundamental limitations of its accuracy are examined. Special filter functions leading to an improved spatial definition and a fringe-extrapolation algorithm that reduces the errors at the border of the pattern are presented. Numerical simulations predict an accuracy of the phase evaluation of less than 6 mrad under certain conditions. We investigated the reproducibility by experiments with a Michelson interferometer. Deviations of approximately 10 mrad were found. In a second test a Ronchi ruling was imaged, and a well-defined phase change was introduced. We deduce an accuracy of less than 5 mrad rms.
- 1 May 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (13) , 2081-2088
Fringe-pattern analysis with high accuracy by use of the Fourier-transform method: theory and experimental tests
The Fourier-transform method is often used to evaluate fringe patterns. The fundamental limitations of its accuracy are examined. Special filter functions leading to an improved spatial definition and a fringe-extrapolation algorithm that reduces the errors at the border of the pattern are presented. Numerical simulations predict an accuracy of the phase evaluation of less than 6 mrad under certain conditions. We investigated the reproducibility by experiments with a Michelson interferometer. Deviations of approximately 10 mrad were found. In a second test a Ronchi ruling was imaged, and a well-defined phase change was introduced. We deduce an accuracy of less than 5 mrad rms.
- 15 November 2000
- Published by Optica Publishing Group in Optics Letters
- Vol. 25 (22) , 1630-1632
Compensation of lens aberrations in digital holography
The possibility of compensating for the aberrations of an imaging lens in digital holography is outlined theoretically. The principle is demonstrated with a Mach–Zehnder arrangement and transilluminated objects. Diffraction-limited resolution can be obtained with a plano–convex lens. Amplitude and phase objects were imaged.
- 15 November 2000
- Published by Optica Publishing Group in Optics Letters
- Vol. 25 (22) , 1630-1632
Compensation of lens aberrations in digital holography
The possibility of compensating for the aberrations of an imaging lens in digital holography is outlined theoretically. The principle is demonstrated with a Mach–Zehnder arrangement and transilluminated objects. Diffraction-limited resolution can be obtained with a plano–convex lens. Amplitude and phase objects were imaged.
- 1 July 1999
- Published by Optica Publishing Group in Applied Optics
- Vol. 38 (19) , 4103-4105
Measurement of phase objects by simple means
A printed fringe pattern is imaged by a CCD camera, whereas a phase object is placed in the ray path for imaging. The ray deflections distort the image of the pattern and are measured by evaluation of the image with the Fourier transform method.
- 1 July 1999
- Published by Optica Publishing Group in Applied Optics
- Vol. 38 (19) , 4103-4105
Measurement of phase objects by simple means
A printed fringe pattern is imaged by a CCD camera, whereas a phase object is placed in the ray path for imaging. The ray deflections distort the image of the pattern and are measured by evaluation of the image with the Fourier transform method.