Dennis W. Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dennis W. Kim has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
Robert N. Vincent
Children’s Healthcare of Atlanta/Emory University School of Medicine
3 shared publicationsB. Tainter
Division of Cardiology, Department of Pediatrics, University of Minnesota, Masonic Children's Hospital, Minneapolis, MN, USA
2 shared publications- Brian A. Scansen
College of Veterinary Medicine and Biomedical Sciences, Colorado State University Department of Clinical Sciences Fort Collins, Colorado
2 shared publications C. Calkins
Division of Cardiology, Children's Healthcare of Atlanta, GA, USA
2 shared publications- E. Cahill
Department of Clinical Sciences, Colorado State University, Fort Collins, CO, 80523, USA
2 shared publications - Gurumurthy Hiremath
Medical School, University of Minnesota, Minneapolis, Minnesota, USA
2 shared publications
Latest Publications
- Open Access
Impact of Structured Surveillance and Intervention on Long-Term Vein Outcomes in Pediatric Pulmonary Vein Stenosis
Background: Pediatric pulmonary vein stenosis (PVS) is a progressive and recurrent condition associated with high morbidity and mortality. Long-term outcomes of individual pulmonary veins remain poorly described. Methods: All pediatric (p < 0.01) while maintaining continued patency. Conclusions: In pediatric PVS, the first 3 years after diagnosis represent a critical period of active disease with high rates of vein attrition. Veins maintaining patency beyond this period demonstrate a reduced reintervention rate, suggesting stabilization of disease progression. Aggressive surveillance and intervention during this therapeutic window may improve long-term vein and patient outcomes.
Open AccessImpact of Structured Surveillance and Intervention on Long-Term Vein Outcomes in Pediatric Pulmonary Vein Stenosis
Background: Pediatric pulmonary vein stenosis (PVS) is a progressive and recurrent condition associated with high morbidity and mortality. Long-term outcomes of individual pulmonary veins remain poorly described. Methods: All pediatric (p < 0.01) while maintaining continued patency. Conclusions: In pediatric PVS, the first 3 years after diagnosis represent a critical period of active disease with high rates of vein attrition. Veins maintaining patency beyond this period demonstrate a reduced reintervention rate, suggesting stabilization of disease progression. Aggressive surveillance and intervention during this therapeutic window may improve long-term vein and patient outcomes.
- Open Access
- 1 October 2025
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 4 (10)
Different Hearts, Different Standards
- 1 October 2025
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 4 (10)
Open AccessDifferent Hearts, Different Standards
- Open Access
- 11 January 2025
- Published by Elsevier in Journal of Veterinary Cardiology
- Vol. 58, 26-37
Comparative transcatheter intervention for pulmonary valve stenosis: multicenter collaborative study across pediatric and veterinary cardiology centers
- 11 January 2025
- Published by Elsevier in Journal of Veterinary Cardiology
- Vol. 58, 26-37
Open AccessComparative transcatheter intervention for pulmonary valve stenosis: multicenter collaborative study across pediatric and veterinary cardiology centers
- Open Access
- 30 August 2024
- Published by Elsevier in Journal of Veterinary Cardiology
- Vol. 56, 72-83
Comparative transcatheter occlusion of patent ductus arteriosus: multicenter collaborative study across pediatric and veterinary cardiology centers
- 30 August 2024
- Published by Elsevier in Journal of Veterinary Cardiology
- Vol. 56, 72-83
Open AccessComparative transcatheter occlusion of patent ductus arteriosus: multicenter collaborative study across pediatric and veterinary cardiology centers
- 1 December 2020
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 13 (23) , 2755-2765
Single-Barrel, Double-Barrel, and Fenestrated Endografts to Facilitate Transcatheter Pulmonary Valve Replacement in Large RVOT
- 1 December 2020
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 13 (23) , 2755-2765
Single-Barrel, Double-Barrel, and Fenestrated Endografts to Facilitate Transcatheter Pulmonary Valve Replacement in Large RVOT
- 1 September 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (17) , 1785-1787
When Opportunity Knocks on the Front Door
- 1 September 2017
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 10 (17) , 1785-1787
When Opportunity Knocks on the Front Door
- 1 June 2016
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 9 (11) , 1150-1151
Breaking From the Past
- 1 June 2016
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 9 (11) , 1150-1151
Breaking From the Past
- 1 December 2015
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 8 (14) , 1828-1830
Off-Label, On-Target
- 1 December 2015
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 8 (14) , 1828-1830
Off-Label, On-Target
- 11 August 2015
- Published by Springer Nature in Pediatric Cardiology
- Vol. 37 (1) , 62-67
Safety of Magnetic Resonance Imaging After Implantation of Stainless Steel Embolization Coils
Stainless steel embolization coils (SSEC) have been used for over four decades for vascular occlusion. Recently, the safety of these coils in a magnetic resonance environment has been called into question, with important ramifications for thousands of patients with existing coils in place. We performed a retrospective chart review at five tertiary care pediatric centers evaluating all children and young adults with implanted SSEC who underwent magnetic resonance imaging (MRI). Data reviewed included demographics, coil implantation, MRI studies, and follow-up evaluations. Complications such as heating, discomfort, or device migration were specifically sought. Two hundred and ninety-seven patients with implanted SSEC underwent 539 MRI examinations. The median age at SSEC implantation was 2.3 years (1 week–23.2 years). The MRI studies were performed a median of 7.4 years (4 days–23.1 years) after implantation. No patients experienced any reported complications associated with their MRI examinations during the study or at median follow-up post-MRI of 4.8 years (1 day–23 years). In this large, retrospective review of patients with implanted SSEC undergoing MRI, there were no reported adverse events. These findings support the recent change by Cook Medical Inc. of their standard embolization coils from a designation of magnetic resonance unsafe to conditional.
- 11 August 2015
- Published by Springer Nature in Pediatric Cardiology
- Vol. 37 (1) , 62-67
Safety of Magnetic Resonance Imaging After Implantation of Stainless Steel Embolization Coils
Stainless steel embolization coils (SSEC) have been used for over four decades for vascular occlusion. Recently, the safety of these coils in a magnetic resonance environment has been called into question, with important ramifications for thousands of patients with existing coils in place. We performed a retrospective chart review at five tertiary care pediatric centers evaluating all children and young adults with implanted SSEC who underwent magnetic resonance imaging (MRI). Data reviewed included demographics, coil implantation, MRI studies, and follow-up evaluations. Complications such as heating, discomfort, or device migration were specifically sought. Two hundred and ninety-seven patients with implanted SSEC underwent 539 MRI examinations. The median age at SSEC implantation was 2.3 years (1 week–23.2 years). The MRI studies were performed a median of 7.4 years (4 days–23.1 years) after implantation. No patients experienced any reported complications associated with their MRI examinations during the study or at median follow-up post-MRI of 4.8 years (1 day–23 years). In this large, retrospective review of patients with implanted SSEC undergoing MRI, there were no reported adverse events. These findings support the recent change by Cook Medical Inc. of their standard embolization coils from a designation of magnetic resonance unsafe to conditional.
- 20 March 2015
- Published by Springer Nature in Pediatric Cardiology
- Vol. 36 (6) , 1153-1158
Validation of a Prescreening Program for Transcatheter Atrial Septal Defect Closure
Prior to initiation of a formal screening program, 30 % of patients referred for device closure of an atrial septal defect (ASD) at our institution had atrial septal anatomy which precluded ASD device closure. This resulted in inefficiencies in workflow, staff utilization, and inconvenience for families. Our objective was to report our experience with an ASD prescreening evaluation/protocol and family consultation process. This is a retrospective study of pediatric patients who underwent a comprehensive ASD prescreening evaluation at Children’s Healthcare of Atlanta between January 2011 and June 2013. The comprehensive prescreening process included a detailed transthoracic echocardiogram and family consultation. Upon establishing a formal prescreening process for patients with secundum ASDs, 138 patients were screened for appropriateness of ASD device closure. At time of prescreening, 40 patients (29 %) were deemed not to be suitable candidates for device ASD closure. In 9 patients (6.5 %), after discussion with the interventionalist, parents elected to pursue surgical ASD closure. A total of 78 patients (56.5 %) underwent successful transcutaneous ASD device closure. In addition, there was a significant discrepancy in the reported size of the ASD between the outside evaluation and the ASD size discovered during the prescreening process. The addition of a prescreening program for transcatheter ASD closure has decreased the incidence of unsuccessful ASD closure from 30 to 10.3 %. The use of a comprehensive evaluation process for ASD device closure improves the likelihood of successful device implantation and permits adequate preprocedural counseling for the patient and family.
- 20 March 2015
- Published by Springer Nature in Pediatric Cardiology
- Vol. 36 (6) , 1153-1158
Validation of a Prescreening Program for Transcatheter Atrial Septal Defect Closure
Prior to initiation of a formal screening program, 30 % of patients referred for device closure of an atrial septal defect (ASD) at our institution had atrial septal anatomy which precluded ASD device closure. This resulted in inefficiencies in workflow, staff utilization, and inconvenience for families. Our objective was to report our experience with an ASD prescreening evaluation/protocol and family consultation process. This is a retrospective study of pediatric patients who underwent a comprehensive ASD prescreening evaluation at Children’s Healthcare of Atlanta between January 2011 and June 2013. The comprehensive prescreening process included a detailed transthoracic echocardiogram and family consultation. Upon establishing a formal prescreening process for patients with secundum ASDs, 138 patients were screened for appropriateness of ASD device closure. At time of prescreening, 40 patients (29 %) were deemed not to be suitable candidates for device ASD closure. In 9 patients (6.5 %), after discussion with the interventionalist, parents elected to pursue surgical ASD closure. A total of 78 patients (56.5 %) underwent successful transcutaneous ASD device closure. In addition, there was a significant discrepancy in the reported size of the ASD between the outside evaluation and the ASD size discovered during the prescreening process. The addition of a prescreening program for transcatheter ASD closure has decreased the incidence of unsuccessful ASD closure from 30 to 10.3 %. The use of a comprehensive evaluation process for ASD device closure improves the likelihood of successful device implantation and permits adequate preprocedural counseling for the patient and family.