JBJ. Bajorat

J. Bajorat

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


J. Bajorat has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Onset properties of mivacurium measured by mechanomyography depend on the twitch height of the adductor pollicis muscle

    by R. Hofmockel, B. Pohl, J. Bajorat, M. Blobner

    SummaryIntroduction: The influence of the twitch height of the adductor pollicis muscle during baseline measurements on the pharmacodynamic parameters of mivacurium was prospectively evaluated. Patients and methods: Fifty adult patients were anaesthetized with propofol and alfentanil. Neuromuscular function was monitored mechanomyographically by measuring the force of the adductor pollicis muscle following stimulation of the ulnar nerve. Following a stabilization period of 20 min, the individual twitch height of the adductor pollicis muscle was determined before a single bolus of mivacurium (75 μg kg−1) was administered. Patients were divided into two groups. The data of patients whose thumb adduction force was below the median value of all patients were the ‘low force’ group (9.1 ± 1.4 N) and the data of all other patients were the ‘high force’ group (13.7 ± 1.8 N). Results: In the ‘high force’ group, maximum neuromuscular blockade of mivacurium was deeper (0.97 ± 0.05 vs. 0.93 ± 0.06; P < 0.05) and onset faster (2.9 ± 1.1 min vs. 4.0 ± 1.2 min; P < 0.05). Neuromuscular recovery did not differ between the groups. Conclusion: The different onset speeds reflect either different sensitivity to neuromuscular blocking agents with respect to patients' muscle power or a problem of the mechanomyographic measuring technique.

  • Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model

    by J. Bajorat, R. Hofmockel, D. A. Vagts, M. Janda, B. Pohl, C. Beck, G. Noeldge-Schomburg

    Despite the introduction of various less-invasive concepts of cardiac output measurement, pulmonary arterial thermodilution is still the most common measurement technique. This prospective controlled study was designed to compare different methods of cardiac output measurement simultaneously. Pulmonary arterial thermodilution, transpulmonary thermodilution (PiCCO), trans-oesophageal echo-Doppler probe (HemoSonic) and partial carbon dioxide rebreathing technique (NICO monitor) were evaluated against a peri-aortic transit-time flow-probe as reference method in a clinically relevant animal model. After approval from the Local Ethics Committee on Animal Research, the investigations were conducted in nine anesthetized domestic pigs. Systemic haemodynamics were modulated systematically by the application of catecholamines, caval occlusion and exsanguination. Statistical analysis was performed with Bland-Altman and linear regression. A total of 366 paired cardiac output measurements were carried out at a reference cardiac output between 0.5 and 7 L min(-1). The correlation coefficients for pulmonary arterial and transpulmonary thermodilution against reference were 0.93 and 0.95, for trans-oesophageal Doppler and partial rebreathing technique 0.84 and 0.77. Pulmonary arterial thermodilution and transpulmonary thermodilution showed comparable bias and limits of agreement. Where HemoSonic showed an overestimation of cardiac output at a higher precision, NICO overestimated low and underestimated higher cardiac output values. Our data suggest that pulmonary arterial thermodilution and PiCCO may be interchangeably used for cardiac output measurement even under acute haemodynamic changes. The method described by Bland and Altman demonstrated an overestimation of cardiac output for both thermodilution methods. HemoSonic and NICO offer non-invasive alternatives and complementary monitoring tools in numerous clinical situations. Trend monitoring and haemodynamic optimizing can be applied sufficiently, when absolute measures are judged critically in a clinical context. The use of the NICO system seems to be limited during acute circulatory changes.


    • 1 January 2003
      • Vol. 28  (5) , 131-7

    [Acceleromyography registration of the course of neuromuscular blockade of the adductor pollicis muscle using monoaxial and biaxial sensors].

    by R Hofmockel, J Bajorat, O Simanski, Ch Beck, R Kähler, M Janda, B Pohl