Karin Macfelda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Karin Macfelda has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Barbara Kapeller
Department for Biomedical Research Medical University Vienna Vienna Austria
3 shared publications - Johannes Müller
Berlin Heals, 59-61 Knesebeck Str, 10719 Berlin, Germany
3 shared publications Alexander Holly
Department of Biomedical Research (Cell Biology) Medical University of Vienna Waehringer Guertel 18‐20 1090 Vienna Austria
2 shared publicationsBarbara Kapeller
Department of Biomedical Research (Cell Biology) Medical University of Vienna Waehringer Guertel 18‐20 1090 Vienna Austria
2 shared publicationsUdo M. Losert
Medical University Vienna
2 shared publications- Agnes Haider
Department of Cranio-, Maxillofacial and Oral Surgery, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
1 shared publication
Latest Publications
- Open Access
- 30 June 2017
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 4 (3) , 291-300
Bioelectrical Signals Improve Cardiac Function and Modify Gene Expression of Extracellular Matrix Components
Beyond the influence of stimulating devices on cardiac excitation, their use in treating patients with heart failure has positive effects on the myocardium at the molecular level. Electrical signals can induce a wide spectrum of effects in living tissue. Therefore, we sought to determine whether applying electrical microcurrent directly to failing hearts leads to functional improvement. Sixteen male spontaneously hypertensive rats (SHRs) with heart failure underwent application of a patch electrode to the left ventricular epicardium and placement of a subcutaneous counter electrode. The electrode delivered a 0.35 μA microcurrent to nine of the SHRs for 45 ± 3 days; the other seven SHRs were used as controls. At baseline and before the SHRs were humanely put to death, we measured the left ventricular ejection fraction (LVEF) and the thickness of the LV posterior wall during systole and diastole (LVPWs/d). We used quantitative PCR to determine extracellular matrix parameters [collagen I–III, matrix metalloproteinase (MMP)-2, MMP-9, tissue inhibitor of metalloproteinases 3 (TIMP3), TIMP4, connexins (Cxs) 40/43/45, transforming growth factor (TGF)-β, and interleukin (IL)-6]. Among SHRs undergoing microcurrent application, LVEF normalized (mean decrease, 22.8%; P = 0.009), and LVPWs decreased (mean, 35.3%; P = 0.001). Compared with the control group, the SHRs receiving microcurrent exhibited a mean decrease in the gene expression of collagen I (10.6%, P = 0.003), TIMP3 (18.5%, P = 0.005), Cx43 (14.3%, P = 0.003), Cx45 (12.7%, P = 0.020), TGF-β (13.0%, P = 0.005), and IL-6 (53.7%, P = 0.000). Microcurrent application induced no changes in the expression of collagen III, MMP-2, MMP-9, TIMP4, or Cx40. Applying microcurrent to the LV epicardium of SHRs leads to statistically significant functional improvement and alterations in the levels of inflammatory and extracellular matrix components.
- 30 June 2017
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 4 (3) , 291-300
Open AccessBioelectrical Signals Improve Cardiac Function and Modify Gene Expression of Extracellular Matrix Components
Beyond the influence of stimulating devices on cardiac excitation, their use in treating patients with heart failure has positive effects on the myocardium at the molecular level. Electrical signals can induce a wide spectrum of effects in living tissue. Therefore, we sought to determine whether applying electrical microcurrent directly to failing hearts leads to functional improvement. Sixteen male spontaneously hypertensive rats (SHRs) with heart failure underwent application of a patch electrode to the left ventricular epicardium and placement of a subcutaneous counter electrode. The electrode delivered a 0.35 μA microcurrent to nine of the SHRs for 45 ± 3 days; the other seven SHRs were used as controls. At baseline and before the SHRs were humanely put to death, we measured the left ventricular ejection fraction (LVEF) and the thickness of the LV posterior wall during systole and diastole (LVPWs/d). We used quantitative PCR to determine extracellular matrix parameters [collagen I–III, matrix metalloproteinase (MMP)-2, MMP-9, tissue inhibitor of metalloproteinases 3 (TIMP3), TIMP4, connexins (Cxs) 40/43/45, transforming growth factor (TGF)-β, and interleukin (IL)-6]. Among SHRs undergoing microcurrent application, LVEF normalized (mean decrease, 22.8%; P = 0.009), and LVPWs decreased (mean, 35.3%; P = 0.001). Compared with the control group, the SHRs receiving microcurrent exhibited a mean decrease in the gene expression of collagen I (10.6%, P = 0.003), TIMP3 (18.5%, P = 0.005), Cx43 (14.3%, P = 0.003), Cx45 (12.7%, P = 0.020), TGF-β (13.0%, P = 0.005), and IL-6 (53.7%, P = 0.000). Microcurrent application induced no changes in the expression of collagen III, MMP-2, MMP-9, TIMP4, or Cx40. Applying microcurrent to the LV epicardium of SHRs leads to statistically significant functional improvement and alterations in the levels of inflammatory and extracellular matrix components.
- 1 August 2015
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 21 (8) , S19
Significant Enhancement of ATP-Synthesis in Cardiomyocytes By Electric Microcurrent
- 1 August 2015
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 21 (8) , S19
Significant Enhancement of ATP-Synthesis in Cardiomyocytes By Electric Microcurrent
- Open Access
3D Printable Biophotopolymers for in Vivo Bone Regeneration
The present study investigated two novel biophotopolymer classes that are chemically based on non-toxic poly (vinyl alcohol). These vinylesters and vinylcarbonates were compared to standard acrylates in vitro on MC3T3-E1 cells and in vivo in a small animal model. In vitro, both vinylester and vinylcarbonate monomers showed about tenfold less cytotoxicity when compared to acrylates (IC50: 2.922 mM and 2.392 mM vs. 0.201 mM) and at least threefold higher alkaline phosphatase activity (17.038 and 18.836 vs. 5.795, measured at [10 mM]). In vivo, polymerized 3D cellular structures were implanted into the distal femoral condyle of 16 New Zealand White Rabbits and were observed for periods from 4 to 12 weeks. New bone formation and bone to implant contact was evaluated by histomorphometry at end of observation. Vinylesters showed similar rates of new bone formation but significantly less (p = 0.002) bone to implant contact, when compared to acrylates. In contrast, the implantation of vinylcarbonate based biophotopolymers led to significantly higher rates of newly formed bone (p < 0.001) and bone to implant contact (p < 0.001). Additionally, distinct signs of polymer degradation could be observed in vinylesters and vinylcarbonates by histology. We conclude, that vinylesters and vinylcarbonates are promising new biophotopolymers, that outmatch available poly(lactic acid) and (meth)acrylate based materials.
Open Access3D Printable Biophotopolymers for in Vivo Bone Regeneration
The present study investigated two novel biophotopolymer classes that are chemically based on non-toxic poly (vinyl alcohol). These vinylesters and vinylcarbonates were compared to standard acrylates in vitro on MC3T3-E1 cells and in vivo in a small animal model. In vitro, both vinylester and vinylcarbonate monomers showed about tenfold less cytotoxicity when compared to acrylates (IC50: 2.922 mM and 2.392 mM vs. 0.201 mM) and at least threefold higher alkaline phosphatase activity (17.038 and 18.836 vs. 5.795, measured at [10 mM]). In vivo, polymerized 3D cellular structures were implanted into the distal femoral condyle of 16 New Zealand White Rabbits and were observed for periods from 4 to 12 weeks. New bone formation and bone to implant contact was evaluated by histomorphometry at end of observation. Vinylesters showed similar rates of new bone formation but significantly less (p = 0.002) bone to implant contact, when compared to acrylates. In contrast, the implantation of vinylcarbonate based biophotopolymers led to significantly higher rates of newly formed bone (p < 0.001) and bone to implant contact (p < 0.001). Additionally, distinct signs of polymer degradation could be observed in vinylesters and vinylcarbonates by histology. We conclude, that vinylesters and vinylcarbonates are promising new biophotopolymers, that outmatch available poly(lactic acid) and (meth)acrylate based materials.
- 31 August 2007
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 13 (6) , S119-119
Myocardial Extracellular Matrix Normalization by Electrical Microcurrent Application In Vivo. Basics for a Novel Heart Failure Treatment
- 31 August 2007
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 13 (6) , S119-119
Myocardial Extracellular Matrix Normalization by Electrical Microcurrent Application In Vivo. Basics for a Novel Heart Failure Treatment
- 21 December 2006
- Published by Wiley in Artificial Organs
- Vol. 31 (1) , 4-12
Behavior of Cardiomyocytes and Skeletal Muscle Cells on Different Extracellular Matrix Components—Relevance for Cardiac Tissue Engineering
Abstract: Myocardial cell transplantation in patients with heart failure is emerging as a potential therapeutic option to augment the function of remaining myocytes. Nevertheless, further investigations on basic issues such as ideal cell type continue to be evaluated. Therefore, the aim of our studies was to compare the performance of skeletal muscle cells and cardiomyocytes with respect to their proliferation rate and viability on different extracellular matrix components (EMCs). Rat cardiomyocytes (RCM) and rat skeletal muscle cells (RSMC) were cultured on EMCs such as collagen type I, type IV, laminin, and fibronectin. The components were used as “single coating” as well as “double coating.” Proliferation rates were determined by proliferation assays on days 1, 2, 4, and 8 after inoculation of the cells. The most essential result is that collagen type I enhances the proliferation rate of RSMC but decreases the proliferation of RCM significantly. This effect is independent of the second EMC used for the double‐coating studies. Other EMCs also influence cellular behavior, whereas the sequence of the EMCs is essential. Results obtained in our studies reveal the significant different proliferation behavior of RCM and RSMC under identical conditions. As skeletal muscle cells are also used in heart tissue engineering models, these results are essential and should be investigated in further studies to prove the applicability of skeletal muscle cells for heart tissue engineering purposes.
- 21 December 2006
- Published by Wiley in Artificial Organs
- Vol. 31 (1) , 4-12
Behavior of Cardiomyocytes and Skeletal Muscle Cells on Different Extracellular Matrix Components—Relevance for Cardiac Tissue Engineering
Abstract: Myocardial cell transplantation in patients with heart failure is emerging as a potential therapeutic option to augment the function of remaining myocytes. Nevertheless, further investigations on basic issues such as ideal cell type continue to be evaluated. Therefore, the aim of our studies was to compare the performance of skeletal muscle cells and cardiomyocytes with respect to their proliferation rate and viability on different extracellular matrix components (EMCs). Rat cardiomyocytes (RCM) and rat skeletal muscle cells (RSMC) were cultured on EMCs such as collagen type I, type IV, laminin, and fibronectin. The components were used as “single coating” as well as “double coating.” Proliferation rates were determined by proliferation assays on days 1, 2, 4, and 8 after inoculation of the cells. The most essential result is that collagen type I enhances the proliferation rate of RSMC but decreases the proliferation of RCM significantly. This effect is independent of the second EMC used for the double‐coating studies. Other EMCs also influence cellular behavior, whereas the sequence of the EMCs is essential. Results obtained in our studies reveal the significant different proliferation behavior of RCM and RSMC under identical conditions. As skeletal muscle cells are also used in heart tissue engineering models, these results are essential and should be investigated in further studies to prove the applicability of skeletal muscle cells for heart tissue engineering purposes.
- 1 January 2002
- Vol. 19 (1) , 21-6
[Good cell culture practice--implementation of a relational cell culture database].
The claim for cell culture to provide validable in vitro models for biomedical research postulates evasion of possible fatal record keeping errors. A prototype of a relational computer database for IBM-compatible personal computers using Microsoft(r) Windows 95/98/2000 and NT for administration of cell culture data has been developed using Microsoft(r) Access 98 (Microsoft Corporation, Redmond, USA), -Access Basic, -Visual Basic and Structured Query Language (SQL) (IBM Corporation, Armonk, USA), and was tested successfully. The modular software application manages the many aspects of cell culture laboratory record keeping like detailed information on tissue donor, primary cell isolation/cell line origin, immunohistochemical/molecular biological characterisation, cell countings at passaging/subcultivation/cell aliquotation and cryopreservation. One main feature is a collection of all methods performed at our cell culture laboratory, where linked tables and files store specific informations. Entries into the database are checked via validation rules for correctness to avoid mistakes. The developed prototype has been demonstrated to be an adaptable, reliable tool for improving quality of information storage according to Good Scientific Practice (GSP), Good Cell Culture Practice (GCCP) and general ISO certification trends.
- 1 January 2002
- Vol. 19 (1) , 21-6
[Good cell culture practice--implementation of a relational cell culture database].
The claim for cell culture to provide validable in vitro models for biomedical research postulates evasion of possible fatal record keeping errors. A prototype of a relational computer database for IBM-compatible personal computers using Microsoft(r) Windows 95/98/2000 and NT for administration of cell culture data has been developed using Microsoft(r) Access 98 (Microsoft Corporation, Redmond, USA), -Access Basic, -Visual Basic and Structured Query Language (SQL) (IBM Corporation, Armonk, USA), and was tested successfully. The modular software application manages the many aspects of cell culture laboratory record keeping like detailed information on tissue donor, primary cell isolation/cell line origin, immunohistochemical/molecular biological characterisation, cell countings at passaging/subcultivation/cell aliquotation and cryopreservation. One main feature is a collection of all methods performed at our cell culture laboratory, where linked tables and files store specific informations. Entries into the database are checked via validation rules for correctness to avoid mistakes. The developed prototype has been demonstrated to be an adaptable, reliable tool for improving quality of information storage according to Good Scientific Practice (GSP), Good Cell Culture Practice (GCCP) and general ISO certification trends.