Ivan Kolev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ivan Kolev has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Annemie Bogaerts
Research Group PLASMANT and Center of Excellence PLASMA, Department of Chemistry, University of Antwerp, Antwerp, Belgium
3 shared publications Renaat Gijbels
Department of Chemistry, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk, Belgium
1 shared publication
Latest Publications
- 2 February 2006
- Published by Wiley in Plasma Processes and Polymers
- Vol. 3 (2) , 127-134
PIC – MCC Numerical Simulation of a DC Planar Magnetron
Summary: A 2d3v numerical model of a DC sputter magnetron is presented. The model is fully self‐consistent and kinetic. Based on the Particle‐in‐Cell/Monte Carlo Collisions technique it includes modules for the gas heating and the diffusion transport of the sputtered atoms. An external electric circuit is incorporated to achieve the calculation of the cathode voltage in a self‐consistent manner, as well as the simulation of the constant current regime. The model is applied to a laboratory magnetron operated in argon. Calculated distribution of the electric potential, V, at p = 10 mTorr. The white line corresponds to V = 0 V. image Calculated distribution of the electric potential, V, at p = 10 mTorr. The white line corresponds to V = 0 V.
- 2 February 2006
- Published by Wiley in Plasma Processes and Polymers
- Vol. 3 (2) , 127-134
PIC – MCC Numerical Simulation of a DC Planar Magnetron
Summary: A 2d3v numerical model of a DC sputter magnetron is presented. The model is fully self‐consistent and kinetic. Based on the Particle‐in‐Cell/Monte Carlo Collisions technique it includes modules for the gas heating and the diffusion transport of the sputtered atoms. An external electric circuit is incorporated to achieve the calculation of the cathode voltage in a self‐consistent manner, as well as the simulation of the constant current regime. The model is applied to a laboratory magnetron operated in argon. Calculated distribution of the electric potential, V, at p = 10 mTorr. The white line corresponds to V = 0 V. image Calculated distribution of the electric potential, V, at p = 10 mTorr. The white line corresponds to V = 0 V.
- 18 November 2005
- Published by American Physical Society (APS) in Physical Review E
- Vol. 72 (5) , 056402
Influence of electron recapture by the cathode upon the discharge characteristics in dc planar magnetrons
In dc magnetrons the electrons emitted from the cathode may return there due to the applied magnetic field. When that happens, they can be recaptured or reflected back into the discharge, depending on the value of the reflection coefficient (RC). A 2d3v (two-dimensional in coordinate and three-dimensional in velocity space) particle-in-cell–Monte Carlo model, including an external circuit, is developed to determine the role of the electron recapture in the discharge processes. The detailed discharge structure as a function of RC for two pressures (4 and ) is studied. The importance of electron recapture is clearly manifested, especially at low pressures. The results indicate that the discharge characteristics are dramatically changed with varying RC between 0 and 1. Thus, the electron recapture at the cathode appears to be a significant mechanism in magnetron discharges and RC a very important parameter in their correct quantitative description that should be dealt with cautiously.- 18 November 2005
- Published by American Physical Society (APS) in Physical Review E
- Vol. 72 (5) , 056402
Influence of electron recapture by the cathode upon the discharge characteristics in dc planar magnetrons
In dc magnetrons the electrons emitted from the cathode may return there due to the applied magnetic field. When that happens, they can be recaptured or reflected back into the discharge, depending on the value of the reflection coefficient (RC). A 2d3v (two-dimensional in coordinate and three-dimensional in velocity space) particle-in-cell–Monte Carlo model, including an external circuit, is developed to determine the role of the electron recapture in the discharge processes. The detailed discharge structure as a function of RC for two pressures (4 and ) is studied. The importance of electron recapture is clearly manifested, especially at low pressures. The results indicate that the discharge characteristics are dramatically changed with varying RC between 0 and 1. Thus, the electron recapture at the cathode appears to be a significant mechanism in magnetron discharges and RC a very important parameter in their correct quantitative description that should be dealt with cautiously.- 3 November 2004
- Published by Wiley in Contributions to Plasma Physics
- Vol. 44 (7-8) , 582-588
Numerical Models of the Planar Magnetron Glow Discharges
- 3 November 2004
- Published by Wiley in Contributions to Plasma Physics
- Vol. 44 (7-8) , 582-588
Numerical Models of the Planar Magnetron Glow Discharges