Shigeto Koyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shigeto Koyama has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Keiichi Sasaki
Professor, Division of Advanced Prosthodontics, Graduate School of Dentistry, Tohoku University, Sendai, Japan
4 shared publicationsNaoko Sato
Assistant Professor, Maxillofacial Prosthetics Clinic, Tohoku University Hospital, Sendai, Japan
3 shared publicationsHiroaki Kato
Dental Technician Chief, Dental Laboratory, Tohoku University Hospital, Sendai, Japan
2 shared publicationsSoshi Hanawa
Division of Advanced Prosthodontics, Tohoku University Graduate School of Dentistry
2 shared publicationsTakayuki Harata
Dental Technician, Dental Laboratory, Tohoku University Hospital, Sendai, Japan
2 shared publications- Ai Hirano-Kawamoto
Department of Otolaryngology-Head and Neck Surgery, Tohoku University Graduate School of Medicine, Sendai, Japan
1 shared publication
Latest Publications
- 1 August 2021
- Published by Elsevier in Auris Nasus Larynx
- Vol. 48 (4) , 666-671
Questionnaire survey on pharyngolaryngeal sensation evaluation regarding dysphagia in Japan
- 1 August 2021
- Published by Elsevier in Auris Nasus Larynx
- Vol. 48 (4) , 666-671
Questionnaire survey on pharyngolaryngeal sensation evaluation regarding dysphagia in Japan
- 1 July 2020
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 124 (1) , 123-127
Hermeticity of a hollow obturator model using CAD and rapid prototyping technologies
- 1 July 2020
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 124 (1) , 123-127
Hermeticity of a hollow obturator model using CAD and rapid prototyping technologies
- 1 April 2020
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 123 (4) , 648-652
A workflow for fabricating a hollow obturator by using 3D digital technologies
- 1 April 2020
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 123 (4) , 648-652
A workflow for fabricating a hollow obturator by using 3D digital technologies
- Open Access
- 26 July 2018
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 37 (4) , 521-525
Evaluation of water absorption properties and fabrication of hollow obturator model using 3D digital dentistry
Fluid accumulation in the hollow spaces of obturator is a continuing problem when fabricating hollow obturator prostheses using the conventional method. To address this problem, the three-dimensional (3D) digital technology was used to evaluate water absorption in the inner hollow obturator spaces. Solid and hollow obturator specimens were fabricated using a 3D printer with photocurable resin. Then, the hermeticity was examined by leak testing. These specimens were immersed in distilled water at 37°C. Each specimen was weighed every 24 h for 120 days, and weight changes between each group were compared. Water accumulation in the hollow obturator was not visually observed. Although water absorption was significantly higher in solid specimens, the weight increase rate was also significantly higher in hollow specimens. Applying a laminating 3D photo fabrication made the fabrication of a completely unified hollow obturator model possible.
- 26 July 2018
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 37 (4) , 521-525
Open AccessEvaluation of water absorption properties and fabrication of hollow obturator model using 3D digital dentistry
Fluid accumulation in the hollow spaces of obturator is a continuing problem when fabricating hollow obturator prostheses using the conventional method. To address this problem, the three-dimensional (3D) digital technology was used to evaluate water absorption in the inner hollow obturator spaces. Solid and hollow obturator specimens were fabricated using a 3D printer with photocurable resin. Then, the hermeticity was examined by leak testing. These specimens were immersed in distilled water at 37°C. Each specimen was weighed every 24 h for 120 days, and weight changes between each group were compared. Water accumulation in the hollow obturator was not visually observed. Although water absorption was significantly higher in solid specimens, the weight increase rate was also significantly higher in hollow specimens. Applying a laminating 3D photo fabrication made the fabrication of a completely unified hollow obturator model possible.
- 25 April 2011
- Published by Wiley in Journal of Prosthodontics
- Vol. 20 (4) , 299-304
The Potential of Cohesive Silicone for Facial Prosthetic Use: A Material Property Study and a Clinical Report
Purpose: Prosthetic reconstruction of a facial defect can help to reduce disfigurement and restore the social functioning of the patient. Several methods for holding a prosthesis in place exist, including the use of osseointegrated implants and medical adhesive agents; however, since the treatment options for some patients may be restricted by various health conditions and other limitations, including allergies to adhesive agents, a history of radiation therapy, and financial issues, other options that suit individual demands are required. The objectives of this study were to test the hypothesis that adhesive characteristics could be bestowed on silicone elastomers by altering their catalyst/base silicone ratios (CBR) and to examine the effect of the thickness of the cohesive silicone layer of a prosthesis on its initial adhesive strength. Materials and Methods: The adhesive strengths of specimens with CBRs ranking from 1/10 to 1/70 were examined by the rolling ball tack test. A tensile test was used to evaluate the tensile adhesive strengths of specimens made of layers of cohesive silicone (CBR 1/60) and normal silicone (CBR 1/10) with different thicknesses. Auricular prostheses containing cohesive silicone on the skin side were applied to a 50‐year‐old man with defects in both auricular regions and with reduced manual dexterity due to serious burns. Results: The rolling distance was reduced with a decrease in CBR, and a thinner cohesive silicone (CBR 1/60) layer demonstrated a higher peak load. On clinical application, the adhesion of the auricular prosthesis containing cohesive silicone was improved by expanding the adhesive area and altering the thickness of the cohesive silicone layer, resulting in sufficient adhesion and easier handling than that achieved using an adhesive agent 1 year post delivery. Conclusion: These results suggest that cohesive silicone can be used as a glueless retentive material for facial prostheses.
- 25 April 2011
- Published by Wiley in Journal of Prosthodontics
- Vol. 20 (4) , 299-304
The Potential of Cohesive Silicone for Facial Prosthetic Use: A Material Property Study and a Clinical Report
Purpose: Prosthetic reconstruction of a facial defect can help to reduce disfigurement and restore the social functioning of the patient. Several methods for holding a prosthesis in place exist, including the use of osseointegrated implants and medical adhesive agents; however, since the treatment options for some patients may be restricted by various health conditions and other limitations, including allergies to adhesive agents, a history of radiation therapy, and financial issues, other options that suit individual demands are required. The objectives of this study were to test the hypothesis that adhesive characteristics could be bestowed on silicone elastomers by altering their catalyst/base silicone ratios (CBR) and to examine the effect of the thickness of the cohesive silicone layer of a prosthesis on its initial adhesive strength. Materials and Methods: The adhesive strengths of specimens with CBRs ranking from 1/10 to 1/70 were examined by the rolling ball tack test. A tensile test was used to evaluate the tensile adhesive strengths of specimens made of layers of cohesive silicone (CBR 1/60) and normal silicone (CBR 1/10) with different thicknesses. Auricular prostheses containing cohesive silicone on the skin side were applied to a 50‐year‐old man with defects in both auricular regions and with reduced manual dexterity due to serious burns. Results: The rolling distance was reduced with a decrease in CBR, and a thinner cohesive silicone (CBR 1/60) layer demonstrated a higher peak load. On clinical application, the adhesion of the auricular prosthesis containing cohesive silicone was improved by expanding the adhesive area and altering the thickness of the cohesive silicone layer, resulting in sufficient adhesion and easier handling than that achieved using an adhesive agent 1 year post delivery. Conclusion: These results suggest that cohesive silicone can be used as a glueless retentive material for facial prostheses.